Skip to main content
Erschienen in: Clinical Oral Investigations 3/2008

01.09.2008 | Short Communication

Temperature rise during polymerization of three different provisional materials

verfasst von: Subutay Han Altintas, Isa Yondem, Onjen Tak, Aslihan Usumez

Erschienen in: Clinical Oral Investigations | Ausgabe 3/2008

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to evaluate the temperature rise during polymerization of three different provisional materials by direct method on two different dentin disc thicknesses. Two autopolymerizing; bis-acrylic composite (Fill-in; Kerr), polymethyl methacrylate (Temdent; Weil Dental), and one light polymerizing composite (Revotek LC; GC) provisional restoration materials were used in this study. Sixty dentin discs were prepared from extracted molars (diameter, 5 mm; height, 1 or 2 mm). These dentin discs (1 or 2 mm) were placed on apparatus developed to measure temperature rise. The temperature rise during polymerization was measured under the dentin disc with a J-type thermocouple wire that was connected to a data logger. Statistical analysis was performed with two-way analysis of variance followed by Tukey HSD test (α = 0.05). Temperature rise values statistically varied according to the provisional restoration material used (light polymerized, auto polymerized; P< 0.001) and the dentin thickness (1 and 2 mm; P <0.001). The polymethyl methacrylate based provisional material induced significantly higher temperature rise than other provisional restoration materials at 2-mm dentin thickness (P < 0.01). At 1-mm dentin thickness, polymethyl methacrylate and composite induced significantly higher temperature increase than bis-acrylic composite provisional material (P < 0.05). The risk for heat-induced pulpal damage should be taken into consideration during polymerization of provisional materials in deep cavities in which dentin thickness is less than 1 mm.
Literatur
1.
Zurück zum Zitat Driscoll CF, Woolsey G, Ferguson WM (1991) Comparison of exothermic release during polymerization of four materials used to fabricate interim restorations. J Prosthet Dent 65:504–506PubMedCrossRef Driscoll CF, Woolsey G, Ferguson WM (1991) Comparison of exothermic release during polymerization of four materials used to fabricate interim restorations. J Prosthet Dent 65:504–506PubMedCrossRef
2.
Zurück zum Zitat Hensen EK, Asmussen E (1993) Correlation between dept of cure and temperature rise of a light-activated resin. Scand J Dent Res 101:176–179 Hensen EK, Asmussen E (1993) Correlation between dept of cure and temperature rise of a light-activated resin. Scand J Dent Res 101:176–179
3.
Zurück zum Zitat Hussey D, Biagioni P, Lamey P (1995) Thermographic measurement of temperature change during resin polymerization in vivo. J Dent 23:267–271PubMedCrossRef Hussey D, Biagioni P, Lamey P (1995) Thermographic measurement of temperature change during resin polymerization in vivo. J Dent 23:267–271PubMedCrossRef
4.
Zurück zum Zitat Kim S-H, Watts DC (2004) Exothermic behavior of the polymer-based provisional crown and fixed partial denture materials. Dent Mater 20:383–387PubMedCrossRef Kim S-H, Watts DC (2004) Exothermic behavior of the polymer-based provisional crown and fixed partial denture materials. Dent Mater 20:383–387PubMedCrossRef
5.
Zurück zum Zitat Moulding MB, Loney RW (1991) The effect of cooling techniques on intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 4:332–336PubMed Moulding MB, Loney RW (1991) The effect of cooling techniques on intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 4:332–336PubMed
6.
Zurück zum Zitat Moulding MB, Teplisky PE (1990) Intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 3:299–304PubMed Moulding MB, Teplisky PE (1990) Intrapulpal temperature during direct fabrication of provisional restorations. Int J Prosthodont 3:299–304PubMed
7.
Zurück zum Zitat Raab WHM (1992) Temperature changes in pulpal microcirculation. Proc Fin Dent Soc 88:469–479 Raab WHM (1992) Temperature changes in pulpal microcirculation. Proc Fin Dent Soc 88:469–479
8.
Zurück zum Zitat Young HM, Smith CT, Morton D (2001) Comparative in vitro evaluation of two provisional restorative materials. J Prosthet Dent 85:129–132PubMedCrossRef Young HM, Smith CT, Morton D (2001) Comparative in vitro evaluation of two provisional restorative materials. J Prosthet Dent 85:129–132PubMedCrossRef
9.
Zurück zum Zitat Zach L, Cohen C (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Path 19:515–530PubMedCrossRef Zach L, Cohen C (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Path 19:515–530PubMedCrossRef
Metadaten
Titel
Temperature rise during polymerization of three different provisional materials
verfasst von
Subutay Han Altintas
Isa Yondem
Onjen Tak
Aslihan Usumez
Publikationsdatum
01.09.2008
Verlag
Springer-Verlag
Erschienen in
Clinical Oral Investigations / Ausgabe 3/2008
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-007-0163-7

Weitere Artikel der Ausgabe 3/2008

Clinical Oral Investigations 3/2008 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.