Objective

The objective of the study was to investigate the clinical outcome for electroplated telescopic removable dental prostheses (E-RDPs) with zirconia primary crowns.

Materials and methods

Sixty E-RDPs, with primary crowns manufactured from either cobalt–chromium alloy or zirconia, were fabricated for 56 participants. Electroplating was used to produce gold copings directly on the telescopic primary crowns. These copings were bonded intra-orally to the prosthesis framework. After 36 months, prosthesis survival and number of complications were assessed. Statistical analysis was performed by the use of Kaplan–Meier modeling and the log-rank test.

Results

Survival of the E-RDPs, 96.4% after 3 years, was identical in both groups. The need for aftercare was high but not significantly different: technical complications were observed for 37% and 42.9% of the prostheses for the zirconia and cobalt–chromium alloy primary crowns, respectively. Fracture of composite veneer was the most frequent complication (59.1%). The incidence of fractured abutment teeth, decementation, and endodontic problems was 7.9% in the zirconia group and 14% in the control group. The majority of abutment-level complications were treated restoratively. A significant difference was found for maximum probing depth at the abutment teeth: In the zirconia group, it decreased by 0.2 mm, whereas it increased by 0.8 mm in the control group (p = 0.04).

Conclusions

After 3 years of observation, survival of zirconia E-RDPs was favorable and comparable with that of established double-crown-retained prostheses. Further studies must clarify whether there are benefits of zirconia primary crowns for periodontal health.

Clinical relevance

Although these results encourage the use of zirconia primary crowns, more research is necessary to reduce the number of complications observed for secondary telescopic crowns, for example, failure of the veneer.
Literatur
4.
Zurück zum Zitat Isaacson GO (1969) Telescope crown retainers for removable partial dentures. J Prosthet Dent 22:436–448CrossRefPubMed Isaacson GO (1969) Telescope crown retainers for removable partial dentures. J Prosthet Dent 22:436–448CrossRefPubMed
5.
Zurück zum Zitat Diedrichs G, Rosenhain P (1991) Galvano-outer telescope by direct technique. Quintessenz 42:49–56PubMed Diedrichs G, Rosenhain P (1991) Galvano-outer telescope by direct technique. Quintessenz 42:49–56PubMed
6.
Zurück zum Zitat Stober T, Bermejo JL, Beck-Mussotter J, Seche AC, Lehmann F, Koob J, Rammelsberg P (2012) Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study. Int J Prosthodont 25:209–216PubMed Stober T, Bermejo JL, Beck-Mussotter J, Seche AC, Lehmann F, Koob J, Rammelsberg P (2012) Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study. Int J Prosthodont 25:209–216PubMed
8.
Zurück zum Zitat Zahn T, Zahn B, Janko S, Weigl P, Gerhardt-Szep S, Lauer HC (2016) Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris((c)) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years. Clin Oral Investig 20:1087–1100. doi:10.1007/s00784-015-1597-y CrossRefPubMed Zahn T, Zahn B, Janko S, Weigl P, Gerhardt-Szep S, Lauer HC (2016) Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris((c)) on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years. Clin Oral Investig 20:1087–1100. doi:10.​1007/​s00784-015-1597-y CrossRefPubMed
9.
Zurück zum Zitat Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27:577–585PubMed Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27:577–585PubMed
10.
Zurück zum Zitat Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O (2010) Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases. J Oral Implantol 36:455–465. doi:10.1563/AAID-JOI-D-09-00065 CrossRefPubMed Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O (2010) Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases. J Oral Implantol 36:455–465. doi:10.​1563/​AAID-JOI-D-09-00065 CrossRefPubMed
11.
Zurück zum Zitat Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:337–347CrossRefPubMed Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:337–347CrossRefPubMed
12.
Zurück zum Zitat Schwindling FS, Deisenhofer UK, Seche AC, Lehmann F, Rammelsberg P, Stober T (2016) Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes. Clin Oral Investig. doi:10.1007/s00784-016-1869-1 PubMed Schwindling FS, Deisenhofer UK, Seche AC, Lehmann F, Rammelsberg P, Stober T (2016) Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes. Clin Oral Investig. doi:10.​1007/​s00784-016-1869-1 PubMed
15.
Zurück zum Zitat Turp I, Bozdag E, Sunbuloglu E, Kahruman C, Yusufoglu I, Bayraktar G (2014) Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig 18:2023-2035. doi:10.1007/s00784-013-1183-0 Turp I, Bozdag E, Sunbuloglu E, Kahruman C, Yusufoglu I, Bayraktar G (2014) Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig 18:2023-2035. doi:10.​1007/​s00784-013-1183-0
18.
Zurück zum Zitat Hagiwara Y, Nakajima K (2016) Use of ceria-stabilized zirconia/alumina nanocomposite for fabricating the frameworks of removable dental prostheses: a clinical report. J Prosthet Dent 116:166–171. doi:10.1016/j.prosdent.2016.01.020 Hagiwara Y, Nakajima K (2016) Use of ceria-stabilized zirconia/alumina nanocomposite for fabricating the frameworks of removable dental prostheses: a clinical report. J Prosthet Dent 116:166–171. doi:10.​1016/​j.​prosdent.​2016.​01.​020
22.
Zurück zum Zitat Inukai M, Baba K, John MT, Igarashi Y (2008) Does removable partial denture quality affect individuals’ oral health? J Dent Res 87:736–739CrossRefPubMed Inukai M, Baba K, John MT, Igarashi Y (2008) Does removable partial denture quality affect individuals’ oral health? J Dent Res 87:736–739CrossRefPubMed
23.
Zurück zum Zitat Manicone PF, Rossi Iommetti P, Raffaelli L, Paolantonio M, Rossi G, Berardi D, Perfetti G (2007) Biological considerations on the use of zirconia for dental devices. Int J Immunopathol Pharmacol 20:9–12CrossRefPubMed Manicone PF, Rossi Iommetti P, Raffaelli L, Paolantonio M, Rossi G, Berardi D, Perfetti G (2007) Biological considerations on the use of zirconia for dental devices. Int J Immunopathol Pharmacol 20:9–12CrossRefPubMed
24.
Zurück zum Zitat Bremer F, Grade S, Kohorst P, Stiesch M (2011) In vivo biofilm formation on different dental ceramics. Quintessence Int 42:565–574PubMed Bremer F, Grade S, Kohorst P, Stiesch M (2011) In vivo biofilm formation on different dental ceramics. Quintessence Int 42:565–574PubMed
26.
Zurück zum Zitat Stober T, Bermejo JL, Séché AC, Lehmann F, Rammelsberg P, Bömicke W (2015) Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial. Clin Oral Investig 19:1129–1136. doi:10.1007/s00784-014-1335-x CrossRefPubMed Stober T, Bermejo JL, Séché AC, Lehmann F, Rammelsberg P, Bömicke W (2015) Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial. Clin Oral Investig 19:1129–1136. doi:10.​1007/​s00784-014-1335-x CrossRefPubMed
27.
Zurück zum Zitat Hofmann E, Behr M, Handel G (2002) Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures. Clin Oral Investig 6:104–108CrossRefPubMed Hofmann E, Behr M, Handel G (2002) Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures. Clin Oral Investig 6:104–108CrossRefPubMed
Metadaten
Titel
Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial
verfasst von
Franz Sebastian Schwindling
Franziska Lehmann
Sophia Terebesi
Nicoleta Corcodel
Andreas Zenthöfer
Peter Rammelsberg
Thomas Stober
Publikationsdatum
11.02.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 9/2017
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-017-2067-5

Weitere Artikel der Ausgabe 9/2017

Clinical Oral Investigations 9/2017 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.