Skip to main content
Erschienen in: Clinical Oral Investigations 3/2019

21.06.2018 | Original Article

Reproduction accuracy of articulator mounting with an arbitrary face-bow vs. average values—a controlled, randomized, blinded patient simulator study

verfasst von: M. Oliver Ahlers, Daniel Edelhoff, Holger A. Jakstat

Erschienen in: Clinical Oral Investigations | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Objectives

The benefit from positioning the maxillary casts with the aid of face-bows has been questioned in the past. Therefore, the aim of this study was to investigate the reliability and validity of arbitrary face-bow transfers compared to a process solely based on the orientation by means of average values. For optimized validity, the study was conducted using a controlled, randomized, anonymized, and blinded patient simulator study design.

Material and methods

Thirty-eight undergraduate dental students were randomly divided into two groups; both groups were applied to both methods, in opposite sequences. Investigated methods were the transfer of casts using an arbitrary face-bow in comparison to the transfer using average values based on Bonwill’s triangle and the Balkwill angle. The “patient” used in this study was a patient simulator. All casts were transferred to the same individual articulator, and all the transferred casts were made using type IV special hard stone plaster; for the attachment into the articulator, type II plaster was used. A blinded evaluation was performed based on three-dimensional measurements of three reference points.

Results

The results are presented three-dimensionally in scatterplots. Statistical analysis indicated a significantly smaller variance (Student’s t test, p < 0.05) for the transfer using a face-bow, applicable for all three reference points.

Conclusions

The use of an arbitrary face-bow significantly improves the transfer reliability and hence the validity.

Clinical relevance

To simulate the patient situation in an individual articulator correctly, casts should be transferred at least by means of an arbitrary face-bow.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Ahlers MO (2000) Simulation of Occlusion. dentaConcept, Hamburg Ahlers MO (2000) Simulation of Occlusion. dentaConcept, Hamburg
3.
Zurück zum Zitat Teteruck WR, Lundeen HC (1966) The accuracy of an ear face-bow. J Prosthet Dent 16:1039–1046CrossRefPubMed Teteruck WR, Lundeen HC (1966) The accuracy of an ear face-bow. J Prosthet Dent 16:1039–1046CrossRefPubMed
4.
Zurück zum Zitat Whitsett LD, Shillingburg HT Jr, Keenan MP (1977) Modifications of a new semi-adjustable articulator for use with a caliper style ear face-bow. J Calif Dental Assoc 5:32–38 Whitsett LD, Shillingburg HT Jr, Keenan MP (1977) Modifications of a new semi-adjustable articulator for use with a caliper style ear face-bow. J Calif Dental Assoc 5:32–38
5.
Zurück zum Zitat Hugger A, Holtkamp C, Pröschel P, Drescher D, Stüttgen U (2001) Die Reproduzierbarkeit der elektronisch ermittelten individuellen Scharnierachsenposition. [The reproducibility of an electronic hinge axis localizing method]. Dtsch Zahnärztl Z 56:383–387 Hugger A, Holtkamp C, Pröschel P, Drescher D, Stüttgen U (2001) Die Reproduzierbarkeit der elektronisch ermittelten individuellen Scharnierachsenposition. [The reproducibility of an electronic hinge axis localizing method]. Dtsch Zahnärztl Z 56:383–387
6.
Zurück zum Zitat Palik JF, Nelson DR, White JT (1985) Accuracy of an earpiece face-bow. J Prosthet Dent 53:800–804CrossRefPubMed Palik JF, Nelson DR, White JT (1985) Accuracy of an earpiece face-bow. J Prosthet Dent 53:800–804CrossRefPubMed
7.
Zurück zum Zitat Piehslinger E, Bauer W, Schmiedmayer HB (1995) Computer simulation of occlusal discrepancies resulting from different mounting techniques. J Prosthet Dent 74:279–283CrossRefPubMed Piehslinger E, Bauer W, Schmiedmayer HB (1995) Computer simulation of occlusal discrepancies resulting from different mounting techniques. J Prosthet Dent 74:279–283CrossRefPubMed
8.
Zurück zum Zitat Bowley JF, Michaels GC, Lai TW, Lin PP (1992) Reliability of a facebow transfer procedure. J Prosthet Dent 67:491–498CrossRefPubMed Bowley JF, Michaels GC, Lai TW, Lin PP (1992) Reliability of a facebow transfer procedure. J Prosthet Dent 67:491–498CrossRefPubMed
9.
Zurück zum Zitat Choi DG, Bowley JF, Marx DB, Lee S (1999) Reliability of an ear-bow arbitrary face-bow transfer instrument. J Prosthet Dent 82:150–156CrossRefPubMed Choi DG, Bowley JF, Marx DB, Lee S (1999) Reliability of an ear-bow arbitrary face-bow transfer instrument. J Prosthet Dent 82:150–156CrossRefPubMed
10.
Zurück zum Zitat Adrien P, Schouver J (1997) Methods for minimizing the errors in mandibular model mounting on an articulator. J Oral Rehabil 24:929–935CrossRefPubMed Adrien P, Schouver J (1997) Methods for minimizing the errors in mandibular model mounting on an articulator. J Oral Rehabil 24:929–935CrossRefPubMed
11.
Zurück zum Zitat Castle AL, Anthony TH (1998) Comparing vertical dimension changes with and without a face-bow transfer. Journal of Dental Technology 15:23–25PubMed Castle AL, Anthony TH (1998) Comparing vertical dimension changes with and without a face-bow transfer. Journal of Dental Technology 15:23–25PubMed
13.
Zurück zum Zitat Shodadai SP, Türp JC, Gerds T, Strub JR (2001) Is there a benefit of using an arbitrary facebow for the fabrication of a stabilization appliance? Int J Prosthodont 14:517–522PubMed Shodadai SP, Türp JC, Gerds T, Strub JR (2001) Is there a benefit of using an arbitrary facebow for the fabrication of a stabilization appliance? Int J Prosthodont 14:517–522PubMed
14.
Zurück zum Zitat Hugger A, Türp J, Pröschel P, Strub J, Stüttgen U (2001) Die Anwendung von Gesichtsbögen in der restaurativen Therapie und Funktionsdiagnostik — welches Evidenzniveau liegt vor? [The application of arbitrary face bow registration and transfer - which level of evidence exists?]. Dtsch Zahnärztl Z 56:671–675 Hugger A, Türp J, Pröschel P, Strub J, Stüttgen U (2001) Die Anwendung von Gesichtsbögen in der restaurativen Therapie und Funktionsdiagnostik — welches Evidenzniveau liegt vor? [The application of arbitrary face bow registration and transfer - which level of evidence exists?]. Dtsch Zahnärztl Z 56:671–675
15.
Zurück zum Zitat Morneburg T, Hugger A, Türp J, Schmitter M, Utz K, Freesmeyer W, Rammelsberg P (2010) Wissenschaftliche Mitteilung der Deutschen Gesellschaft für Prothetische Zahnmedizin und Biomaterialien e. V. (DGPro) (vormals DGZPW): Anwendung des Gesichtsbogens beim funktionsgesunden Patienten im Rahmen restaurativer Maßnahmen [Application of face bows for restorative purposes in functionally healthy patients—scientific statement of the DGPro]. Dtsch Zahnärztl Z 65:690–694 Morneburg T, Hugger A, Türp J, Schmitter M, Utz K, Freesmeyer W, Rammelsberg P (2010) Wissenschaftliche Mitteilung der Deutschen Gesellschaft für Prothetische Zahnmedizin und Biomaterialien e. V. (DGPro) (vormals DGZPW): Anwendung des Gesichtsbogens beim funktionsgesunden Patienten im Rahmen restaurativer Maßnahmen [Application of face bows for restorative purposes in functionally healthy patients—scientific statement of the DGPro]. Dtsch Zahnärztl Z 65:690–694
16.
Zurück zum Zitat Egger M, Juni P, Bartlett C, Group C (2001) Value of flow diagrams in reports of randomized controlled trials. JAMA 285:1996–1999CrossRefPubMed Egger M, Juni P, Bartlett C, Group C (2001) Value of flow diagrams in reports of randomized controlled trials. JAMA 285:1996–1999CrossRefPubMed
18.
Zurück zum Zitat Sackett DL, Rosenberg WM (1995) On the need for evidence-based medicine. J Public Health Med 17:330–334PubMed Sackett DL, Rosenberg WM (1995) On the need for evidence-based medicine. J Public Health Med 17:330–334PubMed
19.
Zurück zum Zitat Guyatt GH, Sackett DL, Sinclair JC, Hayward R, Cook DJ, Cook RJ (1995) Users’ guides to the medical literature. IX. A method for grading health care recommendations. Evidence-Based Medicine Working Group [published erratum appears in JAMA 1996 Apr 24;275(16):1232]. JAMA 274:1800–1804CrossRefPubMed Guyatt GH, Sackett DL, Sinclair JC, Hayward R, Cook DJ, Cook RJ (1995) Users’ guides to the medical literature. IX. A method for grading health care recommendations. Evidence-Based Medicine Working Group [published erratum appears in JAMA 1996 Apr 24;275(16):1232]. JAMA 274:1800–1804CrossRefPubMed
20.
Zurück zum Zitat Kordaß B, Rückert B, Stüttgen U (1997) Zur Länge und Lage der Interkondylarachse [Length and position of the intercondylar axis]. Dtsch Zahnärztl Z 52:1–4 Kordaß B, Rückert B, Stüttgen U (1997) Zur Länge und Lage der Interkondylarachse [Length and position of the intercondylar axis]. Dtsch Zahnärztl Z 52:1–4
21.
Zurück zum Zitat Kordaß B, Stüttgen U (1997) Momentane Drehzentren der Unterkieferfunktion [Instantaneous centres of rotation in mandibular function]. Dtsch Zahnärztl Z 52:540–545 Kordaß B, Stüttgen U (1997) Momentane Drehzentren der Unterkieferfunktion [Instantaneous centres of rotation in mandibular function]. Dtsch Zahnärztl Z 52:540–545
22.
Zurück zum Zitat Fu AS, Mehta NR, Forgione AG, Al-Badawi EA, Zawawi KH (2003) Maxillomandibular relationship in TMD patients before and after short-term flat plane bite plate therapy. Cranio 21:172–179CrossRefPubMed Fu AS, Mehta NR, Forgione AG, Al-Badawi EA, Zawawi KH (2003) Maxillomandibular relationship in TMD patients before and after short-term flat plane bite plate therapy. Cranio 21:172–179CrossRefPubMed
Metadaten
Titel
Reproduction accuracy of articulator mounting with an arbitrary face-bow vs. average values—a controlled, randomized, blinded patient simulator study
verfasst von
M. Oliver Ahlers
Daniel Edelhoff
Holger A. Jakstat
Publikationsdatum
21.06.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 3/2019
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-018-2499-6

Weitere Artikel der Ausgabe 3/2019

Clinical Oral Investigations 3/2019 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.