Skip to main content
Erschienen in: Hernia 6/2021

Open Access 07.06.2021 | Original Article

Outcomes of mid-term and long-term degradable biosynthetic meshes in single-stage open complex abdominal wall reconstruction

verfasst von: J. J. M. Claessen, A. S. Timmer, J. J. Atema, M. A. Boermeester

Erschienen in: Hernia | Ausgabe 6/2021

Abstract

Objective

To assess clinical outcomes in patients that underwent open single-stage complex abdominal wall reconstruction (CAWR) with biosynthetic mesh.

Methods

Retrospective observational study of two prospectively registered series of consecutive patients undergoing CAWR with either long-term degradable (LTD) Phasix or mid-term degradable (MTD) BIO-A® biosynthetic mesh in a single institution between June 2016 and December 2019.

Results

From 169 patients with CAWR, 70 consecutive patients were identified who underwent CAWR with either LTD or MTD biosynthetic mesh. More than 85% of patients had an incisional hernia that could be classified as moderately complex to major complex due to a previous wound infection (67%), one or more complicating comorbidities (87.1%), one or more complicating hernia characteristics (75.7%) or contaminated or dirty defects (37.1%). Concomitant component separation was performed in 43 of 70 patients (61.4%). Overall surgical site infection (SSI) rate in these CAWR patients was 45.7%. Seventeen of 70 patients (24.3%) had computed tomography (CT) - and culture-confirmed SSI in direct contact of mesh, suspicious of mesh infection. Mesh removal for persistent local infection occurred in 10% (7 of 70) after a median of 229 days since surgery. Salvage rate of mesh after direct contact with infection was 58.8%. All removed meshes were in the LTD group. Seven patients (10%) had a recurrence; four patients in the LTD group (10%) had a recurrence at a median follow-up of 35 months and three patients in the MTD group (10%) at a median follow-up of 11 months. Three of the seven recurrences occurred in patients with SSI in persistent and direct contact with mesh.

Conclusions

Comorbid patients undergoing open complex abdominal wall reconstruction are at high risk of postoperative wound complications regardless of which type of biosynthetic mesh is used. When in persistent and direct contact with infection, long-term biodegradable biosynthetic meshes may need to be removed, whereas mid-term biodegradable biosynthetic meshes can be salvaged.
Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1007/​s10029-021-02415-7.
Jeroen J.M. Claessen and Allard S. Timmer shared first authorship as both have contributed equally to this manuscript.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Ventral hernia development is one of the most common complications following laparotomy [1]. Where suture repair is associated with unacceptably high recurrence rates, the use of synthetic mesh has acceptable results following abdominal wall reconstruction (AWR) [2]. Patient comorbidities and reconstructions in contaminated hernia sites are associated with postoperative wound complications [3]. The risk of surgical site infection (SSI) and (chronic) mesh infection with the possible need for mesh removal has resulted in surgeons’ reluctance to use permanent synthetic mesh in high-risk settings.
Biologic mesh serves as a temporary scaffold, facilitating revascularization and remodeling of the native abdominal wall [4]. It is proposed that these meshes can withstand or reduce bacterial contamination. Multiple studies investigating the use of biologic mesh in high-risk patients and/or contaminated hernia repair found that most postoperative wound complications can indeed be managed conservatively, and the number of patients that develop mesh infection requiring removal is as low as 0% in non-crosslinked biologic mesh [3, 57]. However, reported hernia recurrence rates could be as high as 30% after 3 years [7, 8]. These results combined with the high purchase costs of biologic meshes have led to a search in alternative meshed to be used in complex AWR (CAWR).
Biosynthetic mesh, also known as biodegradable or bioabsorbable mesh, is composed of absorbable synthetic material and aims to provide the same advantages as biologic mesh, providing a more durable repair but at lower cost. Currently, three biosynthetic meshes are available on the market: BIO-A® (Gore, Flagstaff, AZ, USA), Phasix mesh (CR Bard Inc., Murray Hill, NJ, USA), and TIGR Matrix (Novus Scientific, Uppsala, Sweden). All three are fully resorbable through hydrolyzation in 7, 18 and 36 months, respectively. Published data on biosynthetic meshes used in CAWR is limited [914], and it remains uncertain how these meshes perform when used in high-risk patients and contaminated fields or when in contact with a postoperative SSI. Whether native tissue ingrowth into the temporary scaffold provided by a biosynthetic mesh results in high-quality support to the reconstruction is also in need of more clinical data.
The aim of this study is to assess clinical outcomes in high-risk patients that underwent open single-stage CAWR with one of two types of biosynthetic mesh: a long-term degradable and a mid-term degradable biosynthetic mesh.

Methods

Study design

In this observational study, we retrospectively analyzed two prospectively registered series of consecutive patients in which a biosynthetic mesh, either a long-term degradable (LTD) (Phasix, CR Bard Inc.) or mid-term degradable (MTD) (BIo-A®, Gore) was used for single-stage open CAWR in the Amsterdam UMC, location AMC, The Netherlands, between June 2016 and December 2019. The study was approved by the Institutional Review Board, and is reported following the Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement [15].

Inclusion criteria

Patients were eligible for inclusion if they underwent an open single-stage CAWR using biosynthetic mesh and consented to the use of their data.

Data items

Baseline demographic data included age, gender, body mass index (BMI), smoking status, diabetes mellitus (DM), cardiac disease, chronic obstructive pulmonary disease (COPD), use of medication, number of previous abdominal surgeries and abdominal wall reconstructions, presence of stomata, intestinal fistulas and infected mesh, wound classification status according to the Centers for Disease and Control and Prevention [16], preoperative botulinum toxin A (BTA) injections, hernia width, and loss of domain measured as described by Sabbagh et al. [17]. The risk of postoperative complications and hernia recurrence were classified according to the modified Ventral Hernia Working Group grading system (mVHWG) and the hernia, patient, wound (HPW) classification [18, 19]. The mVHWG classification system does not incorporate important risk factors as hernia width and loss of domain. The HPW classification includes hernia width but not loss of domain. To better describe the complexity of patients and their abdominal wall defects, we, therefore, assigned them to one of three severity classes (minor, moderate and major complex) as described by an expert consensus group in 2014 [20].
Operative data included concomitant bowel surgery, use of a component separation technique (CST; anterior CST or transverse abdominis release (TAR)), specific mesh type, mesh location, full-thickness skin reconstruction, incisional negative pressure wound therapy (iNPWT), and posterior and anterior fascial closure. Anterior component separation (ACS) was defined as an open or endoscopic release of the aponeurosis of the external oblique muscle, 1.5 cm lateral to the linea semilunaris. TAR was defined as separation of the transversus abdominis muscle medial of the neurovascular bundles and the linea semilunaris (following a Rives–Stoppa approach) and further dissection over the transverse fascia. Preparation over the posterior rectus sheath with mesh placement in Rives–Stoppa was not scored as a CST.

Outcome variables

Clinical outcomes analyzed were incidence of (suspected) mesh infection and subsequent need for mesh removal for persistent infection during follow-up, salvage rate of mesh, surgical site occurrence (SSO), SSI, length of hospital stay, reoperations and hernia recurrence. Suspected mesh infection was defined as computed tomography (CT)- and culture- confirmed direct contact of mesh with SSI. Surgical site infection was divided into superficial, deep and organ space according to CDC criteria [16]. Recurrence was assessed during visits to the outpatient clinic and subsequently confirmed with CT. Furthermore, all patients were contacted by telephone and asked if they had visited any other hospital for diagnostics or treatment of their abdominal wall. Patients who did not perceive a recurrence, and declared absence of bulging and pain at the site of the repair, were defined as recurrence free, as a negative reply to these questions has a negative predictive value of 94% for hernia recurrence [21].
Due to the COVID-19 pandemic, we did not invite patients who reported symptoms in line with a possible recurrence for clinical assessment. For patients who deceased during the study period, follow-up extended to the last outpatient visit.

Analysis

All data items are summarized for the entire group, and in subgroups according to the specific type of biosynthetic mesh used. Numerical data are expressed as mean and standard deviation (SD) or median and range. Categorical data are summarized as count and percentage. Preoperative and operative data were compared using the unpaired t test and Chi square or Fisher exact test for numerical and categorical data respectively, with a significant level p < 0.05.
Due to differences in mesh choice based on patient and hernia characteristics over time (Fig. 1), the LTD and MTD mesh groups are two independent series of consecutive patients. In 2019, in more contaminated or major complex cases, we started to use Ovitex® reinforced tissue matrix, a hybrid biological mesh (TELA Bio, Malvern, PA, USA), and we used the MTD biosynthetic mesh BIO-A® for mild or moderately contaminated hernia repair and without risk of needing a bridging repair. Only further forward in time did we use MTD biosynthetic mesh for more complex cases. Therefore, the LTD and MTD biosynthetic mesh groups are a priori not comparable on hernia and surgery characteristics, and as such postoperative outcomes were not statistically compared between the two mesh groups. However, we did assess the cumulative recurrence rate during follow-up using Kaplan–Meier analysis (log rank). The incidence between both groups is compared at the time point at which one-third of patients from one cohort was still at risk of recurrence (censored analysis).

Treatment strategy

The tailored treatment differed between patients, but in general treatment strategy was as follows. All patients were preoperatively assessed and optimized by a multidisciplinary team. In short; patients with intestinal failure were optimized according our in-house protocol supervised by our intestinal failure team [22, 23]. Patients with a complex abdominal wall defect and identified risk factors (e.g., smoking, obesity, diabetes, malnutrition, COPD) were optimized during a prehabilitation period before surgery. As of October 2018, patients with defect widths over 10 cm and/or ≥ 20% loss of domain were treated with preoperative BTA injections bilateral in the lateral abdominal wall musculature.
Mesh choice depended on the complexity of the patients and the reconstruction, as well as the type of mesh available at that time period. A timeline of the developments in CAWR approach in our hospital is presented in Fig. 1. Two types of biosynthetic mesh were introduced in our center for more complex patients; since June 2016 a LTD biosynthetic mesh (Phasix) and since November 2018 a MTD biosynthetic mesh (BIO-A®).
In patients with clean defects, biosynthetic mesh was used as single mesh repair. In large and contaminated/dirty defects, a dual layer technique was used when the anterior fascia could not be closed despite a CST. This technique comprised an intra-abdominal (underlay) biologic mesh as a leverage with parachuting transfascial sutures to pull close the abdominal cavity and thereby protecting the intra-abdominal viscera; a biosynthetic mesh positioned as retro-rectus (sublay) reinforcement ventral to the biologic mesh creating a dual layer repair.
Superficial wound infections were treated conservatively. Deep and organ space SSIs were treated by radiological percutaneous drainage with or without antibiotics. Percutaneous drainage was also performed when a SSI was in direct contact with mesh, CT and culture confirmed, to salvage the suspected infected mesh. If the mesh location remained persistently infectious, operative placement of a negative pressure wound therapy with instillation (NPWT-I) (V.A.C. VERAFLO, KCI, San Antonio, TX, USA)) was performed. When, despite this treatment, the mesh could not be salvaged during the course of several months of follow-up it was surgically removed.

Surgical technique

All operative procedures were tailored to the patient; however, all operations were performed in consistence with international guidelines and consensus [24]. The abdomen was encountered through the previous laparotomy incision, transecting and dissecting but not removing the hernia sac, followed by extensive adhesiolysis. Bioburden was reduced by resection of previously placed mesh and non-viable tissue. Enterocutaneous or enteroatmospheric fistulas were resected by segmental bowel resection, and a hand-sewn anastomosis was constructed. Up-stream diverting stomas were used infrequently when necessary. Tension-free midline closure of both fascial layers was attempted with mesh reinforcement, preventing a bridged repair whenever possible. When indicated and feasible, component separation techniques were used. If the posterior fascia could not be brought together in the midline, one side of the hernia sac was used to close the abdominal cavity. If the anterior fascia could not be closed without midline tension, or when both fascial layers could not be closed at all, a double layer mesh technique was used (see “Treatment strategy”). Biosynthetic mesh was preferably placed in the retro-rectus (sublay) plane. Subcutaneous drains were placed to the surgeon’s discretion (predominantly on the mesh and when a CST was used). Prophylactic closed incision negative pressure wound therapy (NPWT; Prevena, KCI, San Antonio, TX, USA)] for 5–7 days at − 125 mmHg has been standard care in our practice since 2014. In the presence of significant loss of skin quality, large full-thickness skin defects and significant loss of domain, reconstruction was performed in collaboration with plastic and reconstructive surgeons.
Postoperatively all patients were instructed to wear an abdominal binder 24/7 during the first 2 weeks and subsequent for 3 months when mobilizing.

Results

Participant selection and preoperative data

A total of 169 CAWRs were performed during the study period (June 2016 and December 2019); Fig. 2 depicts the subgroups of different meshes used for CAWR. For types and combinations used during the study period (see Online Supplementary material). In 71 of the 169 reconstructions, biosynthetic mesh was used. One patient did not give informed consent. Therefore, a total of 70 patients were included; 40 patients with LTD biosynthetic mesh, and 30 with MTD biosynthetic mesh.
Baseline patient and hernia characteristics of all CAWRs performed with biosynthetic mesh in the study period are presented in Table 1. More than 85% of patients had an incisional hernia that could be classified as moderate to major complex due to a previous wound infection (67%), one or more complicating comorbidities (87.1%), one or more complicating hernia characteristics (75.7%) or contaminated or dirty defects (37.1%). Sixty-seven percent of patients had experienced a previous SSI prior to their indexed CAWR at our institute. Only three patients were had a mVHWG grade I hernias.
Table 1
Preoperative data
 
Total group (n = 70)
LTD (n = 40)
MTD (n = 30)
p value
Mean (± SD), n (%)
Mean (± SD), n (%)
Mean (± SD), n (%)
Patient demographics
 Number of complicating comorbidities presenta
0.301
  0
9 (12.9%)
3 (7.5%)
6 (20%)
 
  1–2
36 (51.4%)
22 (55%)
14 (46.7%)
   ≥ 3
25 (35.7%)
15 (37.5%)
10 (33.3%)
 Age (years)
60.4 (± 14.0)
64.4 (± 12.5)
55.1 (± 14.4)
0.005
 Male sex
35 (50%)
20 (50%)
15 (50%)
0.999
 BMI (kg/m2)
29.1 (± 5.1)
29.0 (± 4.4)
29.0 (± 5.9)
0.889
 Smoking status
0.563
  Active
13 (18.6%)
8 (20%)
5 (16.7%)
 
  Stopped
34 (48.6%)
21 (52.5%)
13 (43.4%)
  Non smoker
23 (32.9%)
11 (27.5%)
12 (40.0%)
 Diabetes mellitus
12 (17.1%)
7 (17.5%)
5 (16.7%)
0.927
 Cardiac disease
14 (20%)
7 (17.5%)
7 (23.2%)
0.764
 COPD
11 (15.7%)
10 (25%)
1 (3.3%)
0.019
 Anticoagulative medication
19 (27.1%)
12 (30%)
7 (23.3%)
0.535
 Immunosuppressive medication
4 (5.7%)
2 (5%)
2 (6.7%)
0.999
 Previous SSI
47 (67%)
27 (67.5%)
20 (66.7%)
0.941
Hernia and wound characteristics
 Number of complicating hernia characteristics presentb
0.048
  0
17 (24.3%)
10 (25%)
7 (23.3%)
 
  1–2
34 (48.6%)
15 (37.5%)
19 (63.3%)
   ≥ 3
19 (27.1%)
15 (37.5%)
4 (13.4%)
 Hernia severity class
0.733
  Minor complex
10 (14.3%)
5 (12.5%)
5 (16.7%)
 
  Moderate complex
26 (37.1%)
14 (35%)
12 (40%)
  Major complex
34 (48.6%)
21 (52.5%)
13 (43.3%)
 Modified VHWG classification, grade
0.190
  1
3 (4.3%)
2 (5%)
1 (3.3%)
 
  2
41 (58.6%)
21 (52.5%)
20 (66.7%)
  3
26 (37.1%)
17 (42.5%)
9 (30.0%)
 HPW classification, stage
0.442
  1 
8 (11.4%)
3 (7.5%)
5 (16.7%)
 
  2
35 (50%)
20 (50%)
15 (50%)
  3
27 (38.6)
17 (42.5%)
10 (33.3%)
 Stoma present
11 (15.7%)
9 (22.5%)
2 (6.7%)
0.072
 Intestinal fistula(s) present
12 (17.1%)
10 (25%)
2 (6.7%)
0.044
 Infected mesh present
6 (8.6%)
3 (7.5%)
3 (10.0%)
0.999
 Previous abdominal surgeries
0.573
  0–2
21 (30%)
14 (35%)
7 (23.3%)
 
  3–4
19 (27.2%)
10 (25%)
9 (30.0%)
   ≥ 5
30 (42.8%)
16 (40%)
14 (46.7%)
 Previous hernia repairs
0.427
  0
33 (47.1%)
21 (52%)
12 (40%)
 
  1
14 (20%)
6 (15%)
8 (26.7%)
   ≥ 2
23 (32.9%)
13 (32.5%)
10 (33.3%)
 CDC classification
0.134
  1
44 (62.9%)
23 (57.5%)
21 (70.0%)
 
  2
9 (12.9%)
4 (10%)
5 (16.7%)
  3
10 (14.3%)
9 (22.5%)
1 (3.3%)
  4
7 (10%)
4 (10%)
3 (10%)
 Preoperative botox injections
18 (25.7%)
18 (60.0%)
0.001
 Hernia width (cm), median (range)
10.0 (0–30)
10.0 (0–30)
10.0 (0–21)
0.728
 Hernia width ≥ 10 cm
30 (42.9%)
18 (45%)
12 (40%)
0.676
 Loss of domain (%), median (range)
10.0 (0–52)
11.0 (0–40)
10.0 (0–52)
0.651
 Loss of domain ≥ 20%
9 (12.9%)
7 (17.5%)
2 (6.7%)
0.180
aIncluding: active smoking, BMI > 30, COPD cardiac disease, DM anticoagulative medication, immunosuppressive medication, previous wound infection
bIncluding: presence of a stoma, intestinal fistula, infected mesh, transverse defect width ≥ 10 cm, loss of domain > 20%, previous hernia repair, concomitant bowel surgery
p-value in bold reflects significant level p<0.05

Surgical data

Surgical data are presented in Table 2. Concomitant bowel surgery was performed in 24.3% (17 patients). A CST was performed in 61.4% of patients (43 of 70 patients) with open ACS in 35.7% and TAR in 20% of patients. Biosynthetic mesh only was used 43 (61.4%) times, whereas in 23 (32.7%) an additional biologic mesh, and in four (5.8%) an additional synthetic or hybrid biologic mesh was used.
Table 2
Surgical data
 
Total group (n = 70)
LTD (n = 40)
MTD (n = 30)
p value
n (%)
n (%)
n (%)
Concomitant bowel surgery
17 (24.3%)
13 (32.5%)
4 (13.3%)
0.064
Component separation (CST)
0.058
 No CST
27 (38.6%)
15 (37.5%)
12 (40.0%)
 
 Open ACS
25 (35.7%)
18 (45%)
7 (23.3%)
 Endo ACS
4 (5.7%)
3 (7.5%)
1 (3.3%)
 Open TAR
14 (20%)
4 (10%)
10 (33.3%)
Mesh type
0.076
 Biosynthetic only
43 (61.4%)
21 (52.5%)
22 (73.3%)
 
 Additional strattice
18 (25.7%)
14 (35%)
4 (13.3%)
 Additional XenMatrix
5 (7.0%)
5 (12.5%)
 Additional OviTex
2 (2.9%)
2 (6.7%)
 Additional Vypro
2 (2.9%)
2 (6.7%)
Biosynthetic mesh location
0.003
 Retro-rectus (sublay)
52 (74.3%)
24 (60%)
28 (93.3%)
 
 Intra-abdominal (underlay)
3 (4.3%)
2 (5%)
1 (3.3%)
 Onlay reinforcement of biologic
9 (12.9%)
9 (22.5%)
 Inlay reinforcement of biologic
6 (8.6%)
5 (12.5%)
1 (3.3%)
Major full-thickness skin reconstruction
15 (21.4%)
10 (25%)
5 (16.7%)
0.400
Postoperative incisional NPWT
62 (88.6%)
36 (90%)
26 (86.7%)
0.717
Fascial closure
0.035
 Anterior + posterior fascia closed
53 (75.7%)
28 (70%)
25 (83.3%)
 
 Posterior fascia closed only
2 (2.9%)
2 (6.7%)
 Bridged repair (anterior nor posterior fascia closed)
15 (21.4%)
12 (30%)
3 (10%)
CST component separation technique, open ACS anterior component separation (Ramirez), endo ACS endoscopic anterior component separation technique, open TAR transversus abdominis release
p-value in bold reflects significant level p<0.05

Differences in preoperative and operative data between LTD and MTD biosynthetic mesh

Presence of COPD and intestinal fistula(s) was much higher in the LTD group (25.0% vs 3.3% p < 0.019 and 25.0% vs 6.7% p < 0.044, respectively), associated with a change in mesh indications over time in our practice. Injection of BTA was performed in 60.0% of patients in the MTD group, and in only 2.4% of the LTD group, associated with the change in practice over time (p < 0.001). Biosynthetic mesh positioning differed significantly between groups (p < 0.003), relating to differences in hernia complexity among the two groups. Biosynthetic mesh was mostly placed in retromuscular (sublay) position in 93.3% of the MTD group vs. 60% of LTD group. Biosynthetic mesh was used as onlay reinforcement after primary fascial closure in 9 patients (22.5%) of the LTD group versus none in the MTD group.

Clinical outcomes

Clinical outcomes are presented in Table 3. Overall SSI rate in these CAWR patients was 45.7%. Seventeen of 70 patients (24.3%) had a SSI in direct contact with mesh on CT, suspicious of mesh infection; of which 10 of 40 patients (25.0%) in the LTD group and 7 of 30 patients (23.3%) in the MTD group. Ten of those 17 patients with SSI in direct contact with mesh had the biosynthetic mesh in the retro-rectus position (4 of 10 in the LTD group and 6 of 7 in the MTD group). In 7 of 70 patients (10%) and 7 of 17 meshes (41.2%) with persistent local infection, the mesh had to be removed after a median of 229 days since surgery. All 7 mesh removals occurred in the LTD group and none in the MTD group. The mesh salvage rate after in direct contact with SSI was 58.8% (30% in the LTD group and 100% in the MTD group).
Table 3
Clinical outcomes
 
Total group (n = 70)
LTD (n = 40)
MTD (n = 30)
n (%)
n (%)
n (%)
Suspected mesh infection because of direct contact with SSI on CTa
17 (24.3%)
10 (25%)
7 (23.3%)
 After CDC 1 or 2 repair
12 (17.1%)
5 (12.5%)
7 (23.3%)
 After CDC 3 or 4 repair
5 (7.1%)
5 (12.5%)
Suspected mesh infection, mesh position
17 (24.3%)
10 (25%)
7 (23.3%)
 Retro-rectus (sublay)
10 (14.2%)
4 (10%)
6 (20%)
 Intra-abdominal (underlay)
2 (2.9%)
2 (5%)
 Onlay reinforcement of biologic
2 (2.9%)
2 (5%)
 Inlay reinforcement of biologic
3 (4.3%)
2 (5%)
1 (3.3%)
Removal of mesh
7 (10%)
7 (17.5%)
 After CDC 1 or 2 repair
4 (5.7%)
4 (10%)
 
 After CDC 3 or 4 repair
3 (4.3%)
3 (7.5%)
Removal of mesh according to position
7 (10%)
7 (17.5%)
 Retro-rectus (sublay)
3 (4.3%)
3 (7.5%)
 
 Intra-abdominal (underlay)
2 (2.9%)
2 (5%)
 Onlay reinforcement of biologic
1 (1.4%)
1 (2.3%)
 Inlay reinforcement of biologic
1 (1.4%)
1 (2.3%)
Days between surgery and mesh removal (median, range)
229 (77–895)
229 (77–895)
Salvage rate of suspected infected meh
10/17 (58.8%)
3/10 (30%)
7/7 (100%)
SSO
 No SSO
31 (44.3%)
14 (35%)
17 (56.7%)
 SSI only
25 (35.7%)
14 (35%)
11 (36.7%)
 Wound dehiscence only
3 (4.3%)
3 (7.5%)
 Seroma/hematoma only
4 (5.7%)
2 (5%)
2 (6.7%)
 Combination of different SSOs
7 (10%)
7 (17%)
SSI (according to CDC)
 No SSI
38 (54.3%)
19 (47.5%)
19 (63.3%)
 Superficial SSI
16 (22.9%)
11 (27.5%)
5 (16.7%)
 Deep SSI
2 (2.9%)
1 (2.3%)
1 (3.3%)
 Organ space SSI
9 (12.8%)
4 (10%)
5 (16.7%)
 Combination of SSIs
5 (7.1%)
5 (12.5%)
SSI according to mesh use
 Biosynthetic use only
19/43 (44.2%)
11/21 (52.4%)
8/22 (36.4%)
 Additional other mesh
13/27 (48.1%)
10/19 (52.6%)
3/8 (37.5%)
Non-mesh-related reoperations
 Surgical treatment of SSOb
9 (12.9%)
6 (15%)
3 (10.0%)
 Anastomotic leakage
1 (1.4%)
1 (3.3%)
 Bowel perforation
1 (1.4%)
1 (2.5%)
 Preexisting diaphragm paralysis
1 (1.4%)
1 (2.5%)
 Recurrent hernia repair
2 (2.9%)
2 (5%)
Hospital stay (days)
 Median, range
7 (4–72)
9 (4–72)
6 (5–40)
Follow-up (months)
 Median, range
20 (3–46)
35 (13–46)
11 (3–17)
Hernia recurrence
7 (10%)
4 (10%)
3 (10%)
 Suspected mesh infectiona prior to recurrence
3
2
1
 Mesh removal prior to recurrence
2
2
aSuspected mesh infection defined as biosynthetic mesh in direct contact with SSI on CT
bIncluding surgical treatment of deep SSI (n = 4), V.A.C. VeraFlo™ treatment of deep SSI (n = 2), evacuation of hematoma (n = 1), excision of infected mitek anchors/osteitis (n = 1), recurrent enterocutaneous fistula (n = 1)
At a median follow-up of 20 months (range 3–46), 7 of 70 patients (10%) had a CT-confirmed recurrent hernia. Median follow-up was 35 months for the LTD group and 11 months for the MTD group. Four of 40 patients (10%) had a recurrence in the LTD group and three of 30 patients (10%) in the MTD group. Two additional patients in the MTD reported symptoms that indicated a possible recurrence. Three of the seven recurrences occurred in patients with SSI in persistent and direct contact with mesh (two patients in the LTD group and one in the MTD group; in the two LTD patients, the mesh needed to be removed).
The cumulative recurrence rate at 13 months postoperative (time at which 1/3 of MTD cohort was still at risk for recurrence) was not statistically different between both groups (p = 0.792; see Online supplementary material).

Discussion

The importance of mesh reinforcement to decrease recurrence rates has been widely acknowledged. However, which mesh to use in which type of patients remains an ongoing subject of discussion [25]. Because patient and hernia characteristics greatly affect clinical outcome and the risk of postoperative wound complications, just as meshes can do, it is difficult to assess the influence of a specific mesh.
Mesh infection with the subsequent need of mesh removal is a feared complication of CAWR. It is, therefore, important to know how the mesh behaves in postoperative local infections; can it be salvaged or does it need to be removed?
Present study evaluates clinical outcomes of two independent series of 70 consecutive patients in total, with moderate to highly complex incisional hernias who underwent single-stage open CAWR using LTD (n = 40) or MTD (n = 30) biosynthetic mesh. With a postoperative SSI rate of 45.7% and mesh in direct contact with SSI, suspicious of mesh infection, occurring in 24.3% of patients, present study shows that when using biosynthetic meshes in complex patients, short-term outcomes remain challenging. Mesh was removed in 10% of patients because of persistent local infection, giving a salvage rate of nearly 60%. The hernia recurrence rate was 10% at a median follow-up of 20 months.
Comparison with other studies with respect to mesh infection is difficult as studies use various definitions for mesh infections. We were very strict in our evaluation of mesh behavior in infected environment and defined mesh infection as CT- and culture-confirmed direct contact of mesh with SSI. With comparable incidence in postoperative mesh infection in both biosynthetic mesh groups, it is interesting to see that the need for mesh removal for persistent infection occurred in 7 of 70 patients (10%), all in the LTD group (seven out of ten infected meshes). It seems that when LTD mesh comes into contact with an infection, few meshes can withstand this and can be salvaged.
The higher rate of SSI could be explained by the percentage of patients (67%) with previously experienced SSI, which compared to most studies was at least twice as high (if reported at all) [9, 10, 12, 14]. This line of reasoning was also confirmed by the fact that we found that suspected mesh infection also occurred in initially non-contaminated setting. The rate of SSIs in the present study is higher in comparison with other studies using just Phasix™ [911, 14, 2629] or just BIO-A® [12, 3032], in which the SSI rates ranged 0–17% and 6.2–18.3%, respectively. Sahoo et al. compare different biosynthetic meshes (i.e., Phasix, BIO-A®, and Tiger) with synthetic mesh, in clean-contaminated and contaminated wounds and report a SSI rate of 22.4%. [33] In the biosynthetic group, no mesh infection is reported and only one mesh removal (1.7%). Another retrospective study with multiple biosynthetic meshes reports 32.7% SSIs; mesh removal in 3.6% [34]. Another factor affecting SSI rate is the use of open ACS, which is with 35.7% considerably higher than the above-mentioned studies of biosynthetic mesh use (range 0–20%). Open component separation (ACS) with its larger wound beds is known to be highly associated with wound complications [35]. Figure 1 shows that endo-CST but in particular TAR was more frequently used after 2018. In addition, the introduction of preoperative botulinum toxin A in 2018 and its liberal use in our institute was able to prevent the need of CST to reach medial fascial closure. Second, for large defects, the simultaneous introduction of a hybrid biological mesh (Ovitex® reinforced tissue matrix) in our practice caused a shift from extended open anterior CST to prevent bridging repair to use of intra-abdominal underlay hybrid reinforced mesh. These two more recent advances in our practice of CAWR simplified the procedure and reduced the surgical wound surface needed for the repair. Furthermore, our vigorously complication registration and culture sampling could account for our high rate of SSIs in which we register even the smallest wound complication. We also investigated if the use of an additional biologic mesh could be an explanation since the use of biologic mesh is reported with high rates of SSI [36]. In the present series, however, SSI rate was comparable for the use of a single biosynthetic mesh or a biosynthetic combined with biologic mesh.
The recurrence rate was 10% with a median follow-up of 20 months. In the MTD group, two patients reported symptoms indicating a recurrence. Due to COVID-19, we did not invite these patients to the outpatient department and could not confirm a recurrence. The reported recurrence rate for MTD is, therefore, possibly underestimated, and may be 16.7% (5 of 30) instead of 10% (3 of 30). Recurrence rates were comparable with other studies (ranging from 0 to 17%), although not all previously published studies used CT for assessing recurrence so the true numbers could be higher than currently published [913, 2833]. For the LTD biosynthetic mesh group, the median follow-up of 35 months is one of the longest in the literature. For the MTD biosynthetic mesh group, the median follow-up of 11 months in present series is, in our opinion, too short to draw any long-term conclusions on recurrences. It is of note though that the MTD mesh is completely absorbed within 7 months [12], but recurrence rates may still increase as time passes. Three of the seven recurrences occurred in patients with SSI in persistent and direct contact with mesh as shown by CT (2 patients in the LTD group and 1 in the MTD group; in the 2 LTD patients the mesh needed to be removed). It seems that LTD biosynthetic mesh can provide an adequate durable repair, but when it comes into direct contact with a local postoperative infection, the mesh needs to be removed more often than it can be salvaged. Whether or not MTD biosynthetic mesh provides a durable repair needs to be awaited due to the relatively short follow-up period, but our results show that this mesh can be salvaged in direct presence of an infection.

Strengths and limitations

Although performing a retrospective analysis, which induces possible selection bias, we included all consecutive and prospectively registered patients treated with biosynthetic mesh without any exclusion criteria. Therefore, the results of our study reflect actual clinical outcomes of the use of these biosynthetic meshes in daily surgical practice of a CAWR tertiary referral center. Where more data are needed assessing long-term outcomes of biosynthetic mesh, the LTD cohort in our study has a median follow-up of 34 months, which is relatively long to earlier studies.
The biggest limitation of the present study is that data from both groups are not suitable for direct statistical comparison and should, therefore, be regarded as two independent series of consecutive patients.
Due to the heterogeneous nature of the referred CAWR population, a combination of meshes and techniques was sometimes needed for the CAWR. Exclusion of these patients would not reflect daily practice, and splitting the cohort would result in small and fragmented subgroups making it hard to draw any conclusions.

Conclusion

Comorbid patients undergoing open complex abdominal wall repair are at high risk of postoperative wound complications regardless of which type of biosynthetic mesh is used. When in persistent and direct contact with infection, LTD biosynthetic meshes may need to be removed, whereas MTD biosynthetic meshes can be salvaged. Present study was not set-up as comparative in nature or to determine which type of biosynthetic mesh should be used in which type of patient, but merely aims to show clinical outcomes of their use in daily practice. It also shows that patient factors are extremely important and that highly complex patients, and not just level of contamination, can equally affect outcomes.

Declarations

Conflict of interest

Jeroen J.M. Claessen, Allard S. Timmer and Jasper J. Atema declare no conflict of interest. Marja A. Boermeester reported receiving institutional grants from J&J/Ethicon, KCI/3 M, BD Bard and New Compliance; and being a speaker and/or instructor for KCI/3 M, J&J/Ethicon, Allergan/LifeCell, Bard, Gore, GD Medical, Medtronic, and Smith & Nephew. No other disclosures were reported.

Human and animal rights

No rights were violated.
All patients provided oral and written consent.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Anhänge

Supplementary Information

Below is the link to the electronic supplementary material.
Literatur
1.
Zurück zum Zitat Poulose BK, Shelton J, Phillips S, Moore D, Nealon W, Penson D et al (2012) Epidemiology and cost of ventral hernia repair: making the case for hernia research. Hernia 16(2):179–183CrossRef Poulose BK, Shelton J, Phillips S, Moore D, Nealon W, Penson D et al (2012) Epidemiology and cost of ventral hernia repair: making the case for hernia research. Hernia 16(2):179–183CrossRef
2.
Zurück zum Zitat Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg. 240(4):578–583 (discussion 83-5)CrossRef Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J (2004) Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg. 240(4):578–583 (discussion 83-5)CrossRef
3.
Zurück zum Zitat Huntington CR, Cox TC, Blair LJ, Schell S, Randolph D, Prasad T et al (2016) Biologic mesh in ventral hernia repair: outcomes, recurrence, and charge analysis. Surgery 160(6):1517–1527CrossRef Huntington CR, Cox TC, Blair LJ, Schell S, Randolph D, Prasad T et al (2016) Biologic mesh in ventral hernia repair: outcomes, recurrence, and charge analysis. Surgery 160(6):1517–1527CrossRef
4.
Zurück zum Zitat Nahabedian MY, Sosin M, Bhanot P (2018) A current review of biologic meshes in abdominal wall reconstruction. Plast Reconstr Surg 142(3 Suppl):74S-81SCrossRef Nahabedian MY, Sosin M, Bhanot P (2018) A current review of biologic meshes in abdominal wall reconstruction. Plast Reconstr Surg 142(3 Suppl):74S-81SCrossRef
5.
Zurück zum Zitat Atema JJ, Furnee EJ, Maeda Y, Warusavitarne J, Tanis PJ, Bemelman WA et al (2017) Major complex abdominal wall repair in contaminated fields with use of a non-cross-linked biologic mesh: a dual-institutional experience. World J Surg 41(8):1993–1999CrossRef Atema JJ, Furnee EJ, Maeda Y, Warusavitarne J, Tanis PJ, Bemelman WA et al (2017) Major complex abdominal wall repair in contaminated fields with use of a non-cross-linked biologic mesh: a dual-institutional experience. World J Surg 41(8):1993–1999CrossRef
6.
Zurück zum Zitat Itani KM, Rosen M, Vargo D, Awad SS, Denoto G 3rd, Butler CE et al (2012) Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH study. Surgery 152(3):498–505CrossRef Itani KM, Rosen M, Vargo D, Awad SS, Denoto G 3rd, Butler CE et al (2012) Prospective study of single-stage repair of contaminated hernias using a biologic porcine tissue matrix: the RICH study. Surgery 152(3):498–505CrossRef
7.
Zurück zum Zitat Rosen MJ, Krpata DM, Ermlich B, Blatnik JA (2013) A 5-year clinical experience with single-staged repairs of infected and contaminated abdominal wall defects utilizing biologic mesh. Ann Surg 257(6):991–996CrossRef Rosen MJ, Krpata DM, Ermlich B, Blatnik JA (2013) A 5-year clinical experience with single-staged repairs of infected and contaminated abdominal wall defects utilizing biologic mesh. Ann Surg 257(6):991–996CrossRef
8.
Zurück zum Zitat de Vries FEE, Hodgkinson JD, Claessen JJM, van Ruler O, Leo CA, Maeda Y et al (2020) Long-term outcomes after contaminated complex abdominal wall reconstruction. Hernia 24(3):459–468CrossRef de Vries FEE, Hodgkinson JD, Claessen JJM, van Ruler O, Leo CA, Maeda Y et al (2020) Long-term outcomes after contaminated complex abdominal wall reconstruction. Hernia 24(3):459–468CrossRef
9.
Zurück zum Zitat Levy AS, Bernstein JL, Premaratne ID, Rohde CH, Otterburn DM, Morrison KA et al (2020) Poly-4-hydroxybutyrate (Phasix) mesh onlay in complex abdominal wall repair. Surg Endosc 8:1 Levy AS, Bernstein JL, Premaratne ID, Rohde CH, Otterburn DM, Morrison KA et al (2020) Poly-4-hydroxybutyrate (Phasix) mesh onlay in complex abdominal wall repair. Surg Endosc 8:1
10.
Zurück zum Zitat Messa CAT, Kozak G, Broach RB, Fischer JP (2019) When the mesh goes away: an analysis of poly-4-hydroxybutyrate mesh for complex hernia repair. Plast Reconstr Surg Glob Open 7(11):e2576CrossRef Messa CAT, Kozak G, Broach RB, Fischer JP (2019) When the mesh goes away: an analysis of poly-4-hydroxybutyrate mesh for complex hernia repair. Plast Reconstr Surg Glob Open 7(11):e2576CrossRef
11.
Zurück zum Zitat Rognoni C, Cuccurullo D, Borsoi L, Bonavina L, Asti E, Crovella F et al (2020) Clinical outcomes and quality of life associated with the use of a biosynthetic mesh for complex ventral hernia repair: analysis of the “Italian Hernia Club” registry. Sci Rep 10(1):10706CrossRef Rognoni C, Cuccurullo D, Borsoi L, Bonavina L, Asti E, Crovella F et al (2020) Clinical outcomes and quality of life associated with the use of a biosynthetic mesh for complex ventral hernia repair: analysis of the “Italian Hernia Club” registry. Sci Rep 10(1):10706CrossRef
12.
Zurück zum Zitat Rosen MJ, Bauer JJ, Harmaty M, Carbonell AM, Cobb WS, Matthews B et al (2017) Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study. Ann Surg 265(1):205–211CrossRef Rosen MJ, Bauer JJ, Harmaty M, Carbonell AM, Cobb WS, Matthews B et al (2017) Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study. Ann Surg 265(1):205–211CrossRef
13.
Zurück zum Zitat Roth JS, Anthone GJ, Selzer DJ, Poulose BK, Bittner JG, Hope WW et al (2018) Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up. Surg Endosc 32(4):1929–1936CrossRef Roth JS, Anthone GJ, Selzer DJ, Poulose BK, Bittner JG, Hope WW et al (2018) Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up. Surg Endosc 32(4):1929–1936CrossRef
14.
Zurück zum Zitat van Rooijen MM, Jairam AP, Tollens T, Jorgensen LN, de Vries Reilingh TS, Piessen G et al (2020) Outcomes of a new slowly resorbable biosynthetic mesh (Phasix) in potentially contaminated incisional hernias: a prospective, multi-center, single-arm trial. Int J Surg 83:31–36CrossRef van Rooijen MM, Jairam AP, Tollens T, Jorgensen LN, de Vries Reilingh TS, Piessen G et al (2020) Outcomes of a new slowly resorbable biosynthetic mesh (Phasix) in potentially contaminated incisional hernias: a prospective, multi-center, single-arm trial. Int J Surg 83:31–36CrossRef
15.
Zurück zum Zitat von Elm E, Altman DG, Egger M, Pocock SJ, Gotzsche PC, Vandenbroucke JP et al (2008) The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol 61(4):344–349CrossRef von Elm E, Altman DG, Egger M, Pocock SJ, Gotzsche PC, Vandenbroucke JP et al (2008) The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. J Clin Epidemiol 61(4):344–349CrossRef
16.
Zurück zum Zitat Mangram AJ, Horan TC, Pearson ML, Silver LC, Jarvis WR (1999) Guideline for prevention of surgical site infection, 1999 centers for disease control and prevention (CDC) hospital infection control practices advisory committee. Am J Infect Control 27(2):97–132 (quiz 3-4; discussion 96)CrossRef Mangram AJ, Horan TC, Pearson ML, Silver LC, Jarvis WR (1999) Guideline for prevention of surgical site infection, 1999 centers for disease control and prevention (CDC) hospital infection control practices advisory committee. Am J Infect Control 27(2):97–132 (quiz 3-4; discussion 96)CrossRef
17.
Zurück zum Zitat Sabbagh C, Dumont F, Robert B, Badaoui R, Verhaeghe P, Regimbeau JM (2011) Peritoneal volume is predictive of tension-free fascia closure of large incisional hernias with loss of domain: a prospective study. Hernia 15(5):559–565CrossRef Sabbagh C, Dumont F, Robert B, Badaoui R, Verhaeghe P, Regimbeau JM (2011) Peritoneal volume is predictive of tension-free fascia closure of large incisional hernias with loss of domain: a prospective study. Hernia 15(5):559–565CrossRef
18.
Zurück zum Zitat Kanters AE, Krpata DM, Blatnik JA, Novitsky YM, Rosen MJ (2012) Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs. J Am Coll Surg 215(6):787–793CrossRef Kanters AE, Krpata DM, Blatnik JA, Novitsky YM, Rosen MJ (2012) Modified hernia grading scale to stratify surgical site occurrence after open ventral hernia repairs. J Am Coll Surg 215(6):787–793CrossRef
19.
Zurück zum Zitat Petro CC, O’Rourke CP, Posielski NM, Criss CN, Raigani S, Prabhu AS et al (2016) Designing a ventral hernia staging system. Hernia 20(1):111–117CrossRef Petro CC, O’Rourke CP, Posielski NM, Criss CN, Raigani S, Prabhu AS et al (2016) Designing a ventral hernia staging system. Hernia 20(1):111–117CrossRef
20.
Zurück zum Zitat Slater NJ, Montgomery A, Berrevoet F, Carbonell AM, Chang A, Franklin M et al (2014) Criteria for definition of a complex abdominal wall hernia. Hernia 18(1):7–17CrossRef Slater NJ, Montgomery A, Berrevoet F, Carbonell AM, Chang A, Franklin M et al (2014) Criteria for definition of a complex abdominal wall hernia. Hernia 18(1):7–17CrossRef
21.
Zurück zum Zitat Sneiders D, Jairam AP, de Smet GHJ, Dawson I, van Eeghem LHA, Vrijland WW et al (2020) incisional hernia cannot be diagnosed by a patient-reported diagnostic questionnaire. J Surg Res 245:656–662CrossRef Sneiders D, Jairam AP, de Smet GHJ, Dawson I, van Eeghem LHA, Vrijland WW et al (2020) incisional hernia cannot be diagnosed by a patient-reported diagnostic questionnaire. J Surg Res 245:656–662CrossRef
22.
Zurück zum Zitat Atema JJ, Mirck B, Van Arum I, Ten Dam SM, Serlie MJ, Boermeester MA (2016) Outcome of acute intestinal failure. Br J Surg 103(6):701–708CrossRef Atema JJ, Mirck B, Van Arum I, Ten Dam SM, Serlie MJ, Boermeester MA (2016) Outcome of acute intestinal failure. Br J Surg 103(6):701–708CrossRef
23.
Zurück zum Zitat de Vries FEE, Claessen JJM, van Hasselt-Gooijer EMS, van Ruler O, Jonkers C, Kuin W et al (2020) Bridging-to-surgery in patients with type 2 intestinal failure. J Gastrointest Surg. 22:1–1 de Vries FEE, Claessen JJM, van Hasselt-Gooijer EMS, van Ruler O, Jonkers C, Kuin W et al (2020) Bridging-to-surgery in patients with type 2 intestinal failure. J Gastrointest Surg. 22:1–1
24.
Zurück zum Zitat Group EF, Vaizey CJ, Maeda Y, Barbosa E, Bozzetti F, Calvo J et al (2016) European Society of Coloproctology consensus on the surgical management of intestinal failure in adults. Colorectal Dis 18(6):535–548CrossRef Group EF, Vaizey CJ, Maeda Y, Barbosa E, Bozzetti F, Calvo J et al (2016) European Society of Coloproctology consensus on the surgical management of intestinal failure in adults. Colorectal Dis 18(6):535–548CrossRef
25.
Zurück zum Zitat Montgomery A (2013) The battle between biological and synthetic meshes in ventral hernia repair. Hernia 17(1):3–11CrossRef Montgomery A (2013) The battle between biological and synthetic meshes in ventral hernia repair. Hernia 17(1):3–11CrossRef
26.
Zurück zum Zitat Buell JF, Sigmon D, Ducoin C, Shapiro M, Teja N, Wynter E et al (2017) Initial experience with biologic polymer scaffold (poly-4-hydroxybuturate) in complex abdominal wall reconstruction. Ann Surg 266(1):185–188CrossRef Buell JF, Sigmon D, Ducoin C, Shapiro M, Teja N, Wynter E et al (2017) Initial experience with biologic polymer scaffold (poly-4-hydroxybuturate) in complex abdominal wall reconstruction. Ann Surg 266(1):185–188CrossRef
27.
Zurück zum Zitat Bueno-Lledo J, Ceno M, Perez-Alonso C, Martinez-Hoed J, Torregrosa-Gallud A, Pous-Serrano S (2020) Biosynthetic resorbable prosthesis is useful in single-stage management of chronic mesh infection after abdominal wall hernia repair. World J Surg 45(2):443–450CrossRef Bueno-Lledo J, Ceno M, Perez-Alonso C, Martinez-Hoed J, Torregrosa-Gallud A, Pous-Serrano S (2020) Biosynthetic resorbable prosthesis is useful in single-stage management of chronic mesh infection after abdominal wall hernia repair. World J Surg 45(2):443–450CrossRef
28.
Zurück zum Zitat Pakula A, Skinner R (2020) Outcomes of open complex ventral hernia repairs with retromuscular placement of poly-4-hydroxybutyrate bioabsorbable mesh. Surg Innov 27(1):32–37CrossRef Pakula A, Skinner R (2020) Outcomes of open complex ventral hernia repairs with retromuscular placement of poly-4-hydroxybutyrate bioabsorbable mesh. Surg Innov 27(1):32–37CrossRef
29.
Zurück zum Zitat Plymale MA, Davenport DL, Dugan A, Zachem A, Roth JS (2018) Ventral hernia repair with poly-4-hydroxybutyrate mesh. Surg Endosc 32(4):1689–1694CrossRef Plymale MA, Davenport DL, Dugan A, Zachem A, Roth JS (2018) Ventral hernia repair with poly-4-hydroxybutyrate mesh. Surg Endosc 32(4):1689–1694CrossRef
30.
Zurück zum Zitat Cho JE, Helm MC, Helm JH, Mier N, Kastenmeier AS, Gould JC et al (2019) Retro-rectus placement of bio-absorbable mesh improves patient outcomes. Surg Endosc 33(8):2629–2634CrossRef Cho JE, Helm MC, Helm JH, Mier N, Kastenmeier AS, Gould JC et al (2019) Retro-rectus placement of bio-absorbable mesh improves patient outcomes. Surg Endosc 33(8):2629–2634CrossRef
31.
Zurück zum Zitat Garcia-Urena MA, Lopez-Monclus J, Cuccurullo D, Blazquez Hernando LA, Garcia-Pastor P, Reggio S et al (2019) Abdominal wall reconstruction utilizing the combination of absorbable and permanent mesh in a retromuscular position: a multicenter prospective study. World J Surg 43(1):149–158CrossRef Garcia-Urena MA, Lopez-Monclus J, Cuccurullo D, Blazquez Hernando LA, Garcia-Pastor P, Reggio S et al (2019) Abdominal wall reconstruction utilizing the combination of absorbable and permanent mesh in a retromuscular position: a multicenter prospective study. World J Surg 43(1):149–158CrossRef
32.
Zurück zum Zitat Munoz-Rodriguez JM, Lopez-Monclus J, San Miguel Mendez C, Perez-Flecha Gonzalez M, Robin-Valle de Lersundi A, Blazquez Hernando LA et al (2020) Outcomes of abdominal wall reconstruction in patients with the combination of complex midline and lateral incisional hernias. Surgery 168(3):532–542CrossRef Munoz-Rodriguez JM, Lopez-Monclus J, San Miguel Mendez C, Perez-Flecha Gonzalez M, Robin-Valle de Lersundi A, Blazquez Hernando LA et al (2020) Outcomes of abdominal wall reconstruction in patients with the combination of complex midline and lateral incisional hernias. Surgery 168(3):532–542CrossRef
33.
Zurück zum Zitat Sahoo S, Haskins IN, Huang LC, Krpata DM, Derwin KA, Poulose BK et al (2017) Early wound morbidity after open ventral hernia repair with biosynthetic or polypropylene mesh. J Am Coll Surg 225(4):472–80 e1CrossRef Sahoo S, Haskins IN, Huang LC, Krpata DM, Derwin KA, Poulose BK et al (2017) Early wound morbidity after open ventral hernia repair with biosynthetic or polypropylene mesh. J Am Coll Surg 225(4):472–80 e1CrossRef
34.
Zurück zum Zitat Warren J, Desai SS, Boswell ND, Hancock BH, Abbad H, Ewing JA et al (2020) Safety and efficacy of synthetic mesh for ventral hernia repair in a contaminated field. J Am Coll Surg 230(4):405–413CrossRef Warren J, Desai SS, Boswell ND, Hancock BH, Abbad H, Ewing JA et al (2020) Safety and efficacy of synthetic mesh for ventral hernia repair in a contaminated field. J Am Coll Surg 230(4):405–413CrossRef
35.
Zurück zum Zitat Reilingh TSD, van Goor H, Charbon JA, Rosman C, Hesselink EJ, van der Wilt GJ et al (2007) Repair of giant midline abdominal wall hernias: “components separation technique” versus prosthetic repair—interim analysis of a randomized controlled trial. World J Surg 31(4):756–763CrossRef Reilingh TSD, van Goor H, Charbon JA, Rosman C, Hesselink EJ, van der Wilt GJ et al (2007) Repair of giant midline abdominal wall hernias: “components separation technique” versus prosthetic repair—interim analysis of a randomized controlled trial. World J Surg 31(4):756–763CrossRef
36.
Zurück zum Zitat Atema JJ, de Vries FEE, Boermeester MA (2016) Systematic review and meta-analysis of the repair of potentially contaminated and contaminated abdominal wall defects. Am J Surg 212(5):982CrossRef Atema JJ, de Vries FEE, Boermeester MA (2016) Systematic review and meta-analysis of the repair of potentially contaminated and contaminated abdominal wall defects. Am J Surg 212(5):982CrossRef
Metadaten
Titel
Outcomes of mid-term and long-term degradable biosynthetic meshes in single-stage open complex abdominal wall reconstruction
verfasst von
J. J. M. Claessen
A. S. Timmer
J. J. Atema
M. A. Boermeester
Publikationsdatum
07.06.2021
Verlag
Springer Paris
Erschienen in
Hernia / Ausgabe 6/2021
Print ISSN: 1265-4906
Elektronische ISSN: 1248-9204
DOI
https://doi.org/10.1007/s10029-021-02415-7

Weitere Artikel der Ausgabe 6/2021

Hernia 6/2021 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.