Skip to main content
Erschienen in: Clinical Rheumatology 3/2018

19.01.2018 | Review Article

Role of dual-energy CT in the diagnosis and follow-up of gout: systematic analysis of the literature

verfasst von: André Ramon, Amélie Bohm-Sigrand, Pierre Pottecher, Pascal Richette, Jean-Francis Maillefert, Herve Devilliers, Paul Ornetti

Erschienen in: Clinical Rheumatology | Ausgabe 3/2018

Einloggen, um Zugang zu erhalten

Abstract

The aim of this systematic review was to determine the potential role of dual-energy CT in the diagnosis and follow-up of gout with regard to the Outcome Measures in Rheumatology (OMERACT) filter. A systematic analysis of the literature was conducted using the MEDLINE and Cochrane databases and published abstracts of international congresses, according to the criteria of the OMERACT filter: feasibility, reproducibility, validity versus laboratory (serum urate, MSU synovial fluid aspirate) and other imaging modalities for gout, and its sensitivity to change in patients on urate lowering therapy (ULT). Thirty-two articles were found representing a total of 1502 patients. The data on feasibility showed that the examination took little time and involved low levels of radiation but had current limited availability. Intra- and inter-observer reproducibility was excellent, with intra-class correlation coefficients > 0.9. Validity in comparison with polarized-light microscopy showed good sensitivity and specificity (> 80%). The diagnostic performance was better than that of radiography and conventional CT-scan and at least equivalent to that of ultrasonography. The sensitivity to change varied with effect sizes from 0.05 (low) to 1.24 (high) for decrease in the tophus volume following different ULT in gout patients. Dual-energy CT-scan is a reproducible and accurate imaging modality for the diagnosis of gout, particularly for tophaceous gout (intra- or extra-articular). It can become a second-line imaging modality of choice in cases of diagnostic doubt, such as ultrasonography. Its role remains uncertain in the follow-up of gout patients treated with ULT and needs further clarification.
Literatur
2.
Zurück zum Zitat Mccarty DJ, Hollander JL (1961) Identification of urate crystals in gouty synovial fluid. Ann Intern Med 54:452–460CrossRefPubMed Mccarty DJ, Hollander JL (1961) Identification of urate crystals in gouty synovial fluid. Ann Intern Med 54:452–460CrossRefPubMed
3.
Zurück zum Zitat Richette P, Doherty M, Pascual E, Barskova V, Becce F, Castañeda-Sanabria J, Coyfish M, Guillo S, Jansen TL, Janssens H, Lioté F, Mallen C, Nuki G, Perez-Ruiz F, Pimentao J, Punzi L, Pywell T, So A, Tausche AK, Uhlig T, Zavada J, Zhang W, Tubach F, Bardin T (2017) 2016 updated EULAR evidence-based recommendations for the management of gout. Ann Rheum Dis 76(1):29–42. https://doi.org/10.1136/annrheumdis-2016-209707 CrossRefPubMed Richette P, Doherty M, Pascual E, Barskova V, Becce F, Castañeda-Sanabria J, Coyfish M, Guillo S, Jansen TL, Janssens H, Lioté F, Mallen C, Nuki G, Perez-Ruiz F, Pimentao J, Punzi L, Pywell T, So A, Tausche AK, Uhlig T, Zavada J, Zhang W, Tubach F, Bardin T (2017) 2016 updated EULAR evidence-based recommendations for the management of gout. Ann Rheum Dis 76(1):29–42. https://​doi.​org/​10.​1136/​annrheumdis-2016-209707 CrossRefPubMed
4.
Zurück zum Zitat Owens D, Whelan B, McCarthy G (2008) A survey of the management of gout in primary care. Ir Med J 101(5):147–149PubMed Owens D, Whelan B, McCarthy G (2008) A survey of the management of gout in primary care. Ir Med J 101(5):147–149PubMed
7.
Zurück zum Zitat Terslev L, Gutierrez M, Schmidt WA, Keen HI, Filippucci E, Kane D, Thiele R, Kaeley G, Balint P, Mandl P, Delle Sedie A, Hammer HB, Christensen R, Möller I, Pineda C, Kissin E, Bruyn GA, Iagnocco A, Naredo E, D'Agostino MA, OMERACT Ultrasound Working Group (2015) Ultrasound as an outcome measure in gout. A validation process by the OMERACT ultrasound working group. J Rheumatol 42(11):2177–2181. https://doi.org/10.3899/jrheum.141294 CrossRefPubMed Terslev L, Gutierrez M, Schmidt WA, Keen HI, Filippucci E, Kane D, Thiele R, Kaeley G, Balint P, Mandl P, Delle Sedie A, Hammer HB, Christensen R, Möller I, Pineda C, Kissin E, Bruyn GA, Iagnocco A, Naredo E, D'Agostino MA, OMERACT Ultrasound Working Group (2015) Ultrasound as an outcome measure in gout. A validation process by the OMERACT ultrasound working group. J Rheumatol 42(11):2177–2181. https://​doi.​org/​10.​3899/​jrheum.​141294 CrossRefPubMed
8.
Zurück zum Zitat Neogi T, Jansen TL, Dalbeth N, Fransen J, Schumacher HR, Berendsen D, Brown M, Choi H, Edwards NL, Janssens HJ, Lioté F, Naden RP, Nuki G, Ogdie A, Perez-Ruiz F, Saag K, Singh JA, Sundy JS, Tausche AK, Vazquez-Mellado J, Yarows SA, Taylor WJ (2015) 2015 gout classification criteria: an American College of Rheumatology/European league against rheumatism collaborative initiative. Arthritis Rheumatol 67(10):2557–2568. https://doi.org/10.1002/art.39254 CrossRefPubMedPubMedCentral Neogi T, Jansen TL, Dalbeth N, Fransen J, Schumacher HR, Berendsen D, Brown M, Choi H, Edwards NL, Janssens HJ, Lioté F, Naden RP, Nuki G, Ogdie A, Perez-Ruiz F, Saag K, Singh JA, Sundy JS, Tausche AK, Vazquez-Mellado J, Yarows SA, Taylor WJ (2015) 2015 gout classification criteria: an American College of Rheumatology/European league against rheumatism collaborative initiative. Arthritis Rheumatol 67(10):2557–2568. https://​doi.​org/​10.​1002/​art.​39254 CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Boers M, Brooks P, Strand CV, Tugwell P (1998) The OMERACT filter for outcome measures in rheumatology. J Rheumatol 25(2):198–199PubMed Boers M, Brooks P, Strand CV, Tugwell P (1998) The OMERACT filter for outcome measures in rheumatology. J Rheumatol 25(2):198–199PubMed
15.
18.
19.
Zurück zum Zitat Bongartz T, Glazebrook KN, Kavros SJ, Murthy NS, Merry SP, Franz WB 3rd, Michet CJ, Veetil BM, Davis JM 3rd, Mason TG 2nd, Warrington KJ, Ytterberg SR, Matteson EL, Crowson CS, Leng S, McCollough CH (2015) Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. Ann Rheum Dis 74(6):1072–1077. https://doi.org/10.1136/annrheumdis-2013-205095 CrossRefPubMed Bongartz T, Glazebrook KN, Kavros SJ, Murthy NS, Merry SP, Franz WB 3rd, Michet CJ, Veetil BM, Davis JM 3rd, Mason TG 2nd, Warrington KJ, Ytterberg SR, Matteson EL, Crowson CS, Leng S, McCollough CH (2015) Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. Ann Rheum Dis 74(6):1072–1077. https://​doi.​org/​10.​1136/​annrheumdis-2013-205095 CrossRefPubMed
25.
Zurück zum Zitat Bayat S, Aati O, Rech J, Sapsford M, Cavallaro A, Lell M, Araujo E, Petsch C, Stamp LK, Schett G, Manger B, Dalbeth N (2016) Development of a dual-energy computed tomography scoring system for measurement of urate deposition in gout. Arthritis Care Res 68(6):769–775. https://doi.org/10.1002/acr.22754 CrossRef Bayat S, Aati O, Rech J, Sapsford M, Cavallaro A, Lell M, Araujo E, Petsch C, Stamp LK, Schett G, Manger B, Dalbeth N (2016) Development of a dual-energy computed tomography scoring system for measurement of urate deposition in gout. Arthritis Care Res 68(6):769–775. https://​doi.​org/​10.​1002/​acr.​22754 CrossRef
30.
41.
Zurück zum Zitat Terslev L, Gutierrez M, Christensen R, Balint PV, Bruyn GA, Delle Sedie A, Filippucci E, Garrido J, Hammer HB, Iagnocco A, Kane D, Kaeley GS, Keen H, Mandl P, Naredo E, Pineda C, Schicke B, Thiele R, D'Agostino MA, Schmidt WA, OMERACT US Gout Task Force (2015) Assessing elementary lesions in gout by ultrasound: results of an OMERACT patient-based agreement and reliability exercise. J Rheumatol 42(11):2149–2154. https://doi.org/10.3899/jrheum.150366 CrossRefPubMed Terslev L, Gutierrez M, Christensen R, Balint PV, Bruyn GA, Delle Sedie A, Filippucci E, Garrido J, Hammer HB, Iagnocco A, Kane D, Kaeley GS, Keen H, Mandl P, Naredo E, Pineda C, Schicke B, Thiele R, D'Agostino MA, Schmidt WA, OMERACT US Gout Task Force (2015) Assessing elementary lesions in gout by ultrasound: results of an OMERACT patient-based agreement and reliability exercise. J Rheumatol 42(11):2149–2154. https://​doi.​org/​10.​3899/​jrheum.​150366 CrossRefPubMed
Metadaten
Titel
Role of dual-energy CT in the diagnosis and follow-up of gout: systematic analysis of the literature
verfasst von
André Ramon
Amélie Bohm-Sigrand
Pierre Pottecher
Pascal Richette
Jean-Francis Maillefert
Herve Devilliers
Paul Ornetti
Publikationsdatum
19.01.2018
Verlag
Springer London
Erschienen in
Clinical Rheumatology / Ausgabe 3/2018
Print ISSN: 0770-3198
Elektronische ISSN: 1434-9949
DOI
https://doi.org/10.1007/s10067-017-3976-z

Weitere Artikel der Ausgabe 3/2018

Clinical Rheumatology 3/2018 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.