Influence of dentin thickness on intrapulpal temperature under simulated pulpal pressure during Nd:YAG laser irradiation

verfasst von: L. R. Santis, T. M. Silva, B. A. Haddad, L. L. Gonçalves, S. E. P. Gonçalves

Erschienen in: Lasers in Medical Science | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to evaluate the effects of dentin thickness and pulpal pressure simulation (PPS) on the variation of intrapulpal temperature (T) when submitted to an adhesive technique using laser irradiation. Sixty sound human molars were sectioned and randomly divided into two groups (n = 30): group 1—1 mm of dentin thickness; group 2—2 mm of dentin thickness. Each group was divided into two subgroups (n = 15): subgroup A—absence of PPS; subgroup P—presence of PPS (15 cm H2O), sequentially treated with the following: 37 % phosphoric acid, adhesive system (Adper Single Bond), irradiation with Nd:YAG laser (1064 nm, 10 Hz, 60 s) using 60, 80, and 100 mJ/pulse energy parameters and light-curing (10 s). The T was evaluated during the laser irradiation with a digital thermometer. Data were analyzed by three-way ANOVA and Tukey tests (p < 0.05). Three-way ANOVA revealed no significant differences for dentin thickness (p = 0.6512) on T. PPS significantly reduced T (p = 0.0001). The laser energy parameters (p = 0.0027) indicated that 100 mJ presented with significantly greater T when compared to the groups irradiated with 80 and 60 mJ. Dentin thickness did not affect T. The presence of PPS reduced the mean temperature values. The Nd:YAG laser energy parameters had a negative influence on the variation of temperature in the absence of PPS. In the presence of PPS, there was no risk to the pulp, since this study obtained temperature increases below 5.5 °C for all energy parameters, showing the technical viability for in vivo conditions.
Literatur
1.
Zurück zum Zitat Goncalves SE, de Araujo MA, Damiao AJ (1999) Dentin bond strength: influence of laser irradiation, acid etching, and hypermineralization. J Clin Laser Med Surg 17:77–85PubMed Goncalves SE, de Araujo MA, Damiao AJ (1999) Dentin bond strength: influence of laser irradiation, acid etching, and hypermineralization. J Clin Laser Med Surg 17:77–85PubMed
2.
Zurück zum Zitat Matos AB, Oliveira DC, Navarro RS, de Eduardo CP, Matson E (2000) Nd:YAG laser influence on tensile bond strength of self-etching adhesive systems. J Clin Laser Med Surg 18:253–257PubMed Matos AB, Oliveira DC, Navarro RS, de Eduardo CP, Matson E (2000) Nd:YAG laser influence on tensile bond strength of self-etching adhesive systems. J Clin Laser Med Surg 18:253–257PubMed
3.
Zurück zum Zitat Franke M, Taylor AW, Lago A, Fredel MC (2006) Influence of Nd:YAG laser irradiation on an adhesive restorative procedure. Oper Dent 31:604–609CrossRefPubMed Franke M, Taylor AW, Lago A, Fredel MC (2006) Influence of Nd:YAG laser irradiation on an adhesive restorative procedure. Oper Dent 31:604–609CrossRefPubMed
4.
Zurück zum Zitat Steiner-Oliveira C, Ramalho KM, Bello-Silva MS, Aranha ACC, Eduardo CP (2012) The use of lasers in restorative dentistry: truths and myths. Braz Dent Sci 15:3–15 Steiner-Oliveira C, Ramalho KM, Bello-Silva MS, Aranha ACC, Eduardo CP (2012) The use of lasers in restorative dentistry: truths and myths. Braz Dent Sci 15:3–15
5.
Zurück zum Zitat White JM, Goodis HE, Rose CL (1991) Use of the pulsed Nd:YAG laser for intraoral soft tissue surgery. Lasers Surg Med 11:455–461CrossRefPubMed White JM, Goodis HE, Rose CL (1991) Use of the pulsed Nd:YAG laser for intraoral soft tissue surgery. Lasers Surg Med 11:455–461CrossRefPubMed
6.
Zurück zum Zitat Goodis HE, White JM, Marshall GW Jr, Yee K, Fuller N, Gee L, Marshall SJ (1997) Effects of Nd: and Ho:yttrium-aluminium-garnet lasers on human dentine fluid flow and dental pulp-chamber temperature in vitro. Arch Oral Biol 42:845–854CrossRefPubMed Goodis HE, White JM, Marshall GW Jr, Yee K, Fuller N, Gee L, Marshall SJ (1997) Effects of Nd: and Ho:yttrium-aluminium-garnet lasers on human dentine fluid flow and dental pulp-chamber temperature in vitro. Arch Oral Biol 42:845–854CrossRefPubMed
7.
Zurück zum Zitat Schaller HG, Weihing T, Strub JR (1997) Permeability of dentine after Nd:YAG laser treatment: an in vitro study. J Oral Rehabil 24:274–281CrossRefPubMed Schaller HG, Weihing T, Strub JR (1997) Permeability of dentine after Nd:YAG laser treatment: an in vitro study. J Oral Rehabil 24:274–281CrossRefPubMed
8.
Zurück zum Zitat Matos AB, Oliveira DC, Kuramoto M Jr, Eduardo CP, Matson E (1999) Nd:YAG laser influence on sound dentin bond strength. J Clin Laser Med Surg 17:165–169PubMed Matos AB, Oliveira DC, Kuramoto M Jr, Eduardo CP, Matson E (1999) Nd:YAG laser influence on sound dentin bond strength. J Clin Laser Med Surg 17:165–169PubMed
9.
Zurück zum Zitat Oda M, Oliveira DC, Liberti EA (2001) Morphologic evaluation of the bonding between adhesive/composite resin and dentin irradiated with Er:YAG and Nd:YAG lasers: comparative study using scanning microscopy. Pesqui Odontol Bras 15:283–289CrossRefPubMed Oda M, Oliveira DC, Liberti EA (2001) Morphologic evaluation of the bonding between adhesive/composite resin and dentin irradiated with Er:YAG and Nd:YAG lasers: comparative study using scanning microscopy. Pesqui Odontol Bras 15:283–289CrossRefPubMed
10.
Zurück zum Zitat Araujo RM, Eduardo CP, Duarte Junior SL, Araujo MA, Loffredo LC (2001) Microleakage and nanoleakage: influence of laser in cavity preparation and dentin pretreatment. J Clin Laser Med Surg 19:325–332CrossRefPubMed Araujo RM, Eduardo CP, Duarte Junior SL, Araujo MA, Loffredo LC (2001) Microleakage and nanoleakage: influence of laser in cavity preparation and dentin pretreatment. J Clin Laser Med Surg 19:325–332CrossRefPubMed
11.
Zurück zum Zitat Marimoto AK, Cunha LA, Yui KC, Huhtala MF, Barcellos DC, Prakki A, Gonçalves SE (2013) Influence of Nd:YAG laser on the bond strength of self-etching and conventional adhesive systems to dental hard tissues. Oper Dent 38:447–455CrossRefPubMed Marimoto AK, Cunha LA, Yui KC, Huhtala MF, Barcellos DC, Prakki A, Gonçalves SE (2013) Influence of Nd:YAG laser on the bond strength of self-etching and conventional adhesive systems to dental hard tissues. Oper Dent 38:447–455CrossRefPubMed
12.
Zurück zum Zitat Silva TM, Gonçalves LL, Fonseca BM, Esteves SR, Barcellos DC, Damiao AJ, Gonçalves SE (2016) Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure. Lasers Med Sci 31:49–56CrossRefPubMed Silva TM, Gonçalves LL, Fonseca BM, Esteves SR, Barcellos DC, Damiao AJ, Gonçalves SE (2016) Influence of Nd:YAG laser on intrapulpal temperature and bond strength of human dentin under simulated pulpal pressure. Lasers Med Sci 31:49–56CrossRefPubMed
13.
Zurück zum Zitat Perdigao J, Swift EJ Jr, Denehy GE, Wefel JS, Donly KJ (1994) In vitro bond strengths and SEM evaluation of dentin bonding systems to different dentin substrates. J Dent Res 73:44–55CrossRefPubMed Perdigao J, Swift EJ Jr, Denehy GE, Wefel JS, Donly KJ (1994) In vitro bond strengths and SEM evaluation of dentin bonding systems to different dentin substrates. J Dent Res 73:44–55CrossRefPubMed
14.
Zurück zum Zitat Garberoglio R, Brännström M (1976) Scanning electron microscopic investigation of human dentinal tubules. Arch Oral Biol 21:355–362CrossRefPubMed Garberoglio R, Brännström M (1976) Scanning electron microscopic investigation of human dentinal tubules. Arch Oral Biol 21:355–362CrossRefPubMed
15.
Zurück zum Zitat Marshall GW Jr (1993) Dentin: microstructure and characterization. Quintessence Int 24:606–617PubMed Marshall GW Jr (1993) Dentin: microstructure and characterization. Quintessence Int 24:606–617PubMed
16.
Zurück zum Zitat Brännström M, Lindén LA, Aström A (1967) The hydrodynamics of the dental tubule and of pulp fluid. A discussion of its significance in relation to dentinal sensitivity. Caries Res 1:310–317CrossRefPubMed Brännström M, Lindén LA, Aström A (1967) The hydrodynamics of the dental tubule and of pulp fluid. A discussion of its significance in relation to dentinal sensitivity. Caries Res 1:310–317CrossRefPubMed
17.
Zurück zum Zitat Sauro S, Pashley DH, Montanari M, Chersoni S, Carvalho RM, Toledano M, Osorio R, Tay FR, Prati C (2007) Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives. Dent Mater 23:705–713CrossRefPubMed Sauro S, Pashley DH, Montanari M, Chersoni S, Carvalho RM, Toledano M, Osorio R, Tay FR, Prati C (2007) Effect of simulated pulpal pressure on dentin permeability and adhesion of self-etch adhesives. Dent Mater 23:705–713CrossRefPubMed
18.
Zurück zum Zitat White JM, Fagan MC, Goodis HE (1994) Intrapulpal temperatures during pulsed Nd:YAG laser treatment of dentin, in vitro. J Periodontol 65:255–259CrossRefPubMed White JM, Fagan MC, Goodis HE (1994) Intrapulpal temperatures during pulsed Nd:YAG laser treatment of dentin, in vitro. J Periodontol 65:255–259CrossRefPubMed
19.
Zurück zum Zitat Lizarelli RF, Moriyama LT, Bagnato VS (2006) Temperature response in the pulpal chamber of primary human teeth exposed to Nd:YAG laser using a picosecond pulsed regime. Photomed Laser Surg 24:610–615CrossRefPubMed Lizarelli RF, Moriyama LT, Bagnato VS (2006) Temperature response in the pulpal chamber of primary human teeth exposed to Nd:YAG laser using a picosecond pulsed regime. Photomed Laser Surg 24:610–615CrossRefPubMed
20.
Zurück zum Zitat Ozök AR, Wu MK, De Gee AJ, Wesselink PR (2004) Effect of dentin perfusion on the sealing ability and microtensile bond strengths of a total-etch versus an all-in-one adhesive. Dent Mater 20:479–486CrossRefPubMed Ozök AR, Wu MK, De Gee AJ, Wesselink PR (2004) Effect of dentin perfusion on the sealing ability and microtensile bond strengths of a total-etch versus an all-in-one adhesive. Dent Mater 20:479–486CrossRefPubMed
21.
Zurück zum Zitat Michida SM, Passos SP, Marimoto AR, Garakis MC, de Araújo MA (2009) Intrapulpal temperature variation during bleaching with various activation mechanisms. J Appl Oral Sci 17:436–439CrossRefPubMedPubMedCentral Michida SM, Passos SP, Marimoto AR, Garakis MC, de Araújo MA (2009) Intrapulpal temperature variation during bleaching with various activation mechanisms. J Appl Oral Sci 17:436–439CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Belli R, Sartori N, Peruchi LD, Guimarães JC, Araújo E, Monteiro S Jr, Baratieri LN, Lohbauer U (2010) Slow progression of dentin bond degradation during one-year water storage under simulated pulpal pressure. J Dent 38:802–810CrossRefPubMed Belli R, Sartori N, Peruchi LD, Guimarães JC, Araújo E, Monteiro S Jr, Baratieri LN, Lohbauer U (2010) Slow progression of dentin bond degradation during one-year water storage under simulated pulpal pressure. J Dent 38:802–810CrossRefPubMed
23.
Zurück zum Zitat Schmalz G, Hiller KA, Nunez LJ, Stoll J, Weis K (2001) Permeability characteristics of bovine and human dentin under different pretreatment conditions. J Endod 27:23–30CrossRefPubMed Schmalz G, Hiller KA, Nunez LJ, Stoll J, Weis K (2001) Permeability characteristics of bovine and human dentin under different pretreatment conditions. J Endod 27:23–30CrossRefPubMed
24.
Zurück zum Zitat Zach L, Cohen G (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530CrossRefPubMed Zach L, Cohen G (1965) Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 19:515–530CrossRefPubMed
25.
Zurück zum Zitat Secilmis A, Bulbul M, Sari T, Usumez A (2013) Effects of different dentin thicknesses and air cooling on pulpal temperature rise during laser welding. Lasers Med Sci 28:167–170CrossRefPubMed Secilmis A, Bulbul M, Sari T, Usumez A (2013) Effects of different dentin thicknesses and air cooling on pulpal temperature rise during laser welding. Lasers Med Sci 28:167–170CrossRefPubMed
26.
Zurück zum Zitat Cardoso MV, Moretto SG, Carvalho RC, Russo EM (2008) Influence of intrapulpal pressure simulation on the bond strength of adhesive systems to dentin. Braz Oral Res 22:170–175CrossRefPubMed Cardoso MV, Moretto SG, Carvalho RC, Russo EM (2008) Influence of intrapulpal pressure simulation on the bond strength of adhesive systems to dentin. Braz Oral Res 22:170–175CrossRefPubMed
27.
Zurück zum Zitat Pashley DH, Carvalho RM (1997) Dentine permeability and dentine adhesion. J Dent 25:355–372CrossRefPubMed Pashley DH, Carvalho RM (1997) Dentine permeability and dentine adhesion. J Dent 25:355–372CrossRefPubMed
28.
Zurück zum Zitat Türkmen C, Günday M, Karaçorlu M, Basaran B (2000) Effect of CO2, Nd:YAG, and ArF excimer lasers on dentin morphology and pulp chamber temperature: an in vitro study. J Endod 26:644–648CrossRefPubMed Türkmen C, Günday M, Karaçorlu M, Basaran B (2000) Effect of CO2, Nd:YAG, and ArF excimer lasers on dentin morphology and pulp chamber temperature: an in vitro study. J Endod 26:644–648CrossRefPubMed
29.
Zurück zum Zitat Cox CJ, Pearson GJ, Palmer G (1994) Preliminary in vitro investigation of the effects of pulsed Nd:YAG laser radiation on enamel and dentine. Biomaterials 15:1145–1151CrossRefPubMed Cox CJ, Pearson GJ, Palmer G (1994) Preliminary in vitro investigation of the effects of pulsed Nd:YAG laser radiation on enamel and dentine. Biomaterials 15:1145–1151CrossRefPubMed
30.
Zurück zum Zitat Yu D, Powell GL, Higuchi WI, Fox JL (1993) Comparison of three lasers on dental pulp chamber temperature change. J Clin Laser Med Surg 11:119–122PubMed Yu D, Powell GL, Higuchi WI, Fox JL (1993) Comparison of three lasers on dental pulp chamber temperature change. J Clin Laser Med Surg 11:119–122PubMed
31.
Zurück zum Zitat Srimaneepong V, Palamara JE, Wilson PR (2002) Pulpal space pressure and temperature changes from Nd:YAG laser irradiation of dentin. J Dent 30:291–296CrossRefPubMed Srimaneepong V, Palamara JE, Wilson PR (2002) Pulpal space pressure and temperature changes from Nd:YAG laser irradiation of dentin. J Dent 30:291–296CrossRefPubMed
Metadaten
Titel
Influence of dentin thickness on intrapulpal temperature under simulated pulpal pressure during Nd:YAG laser irradiation
verfasst von
L. R. Santis
T. M. Silva
B. A. Haddad
L. L. Gonçalves
S. E. P. Gonçalves
Publikationsdatum
24.10.2016
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 1/2017
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-016-2098-1

Weitere Artikel der Ausgabe 1/2017

Lasers in Medical Science 1/2017 Zur Ausgabe