Skip to main content
Erschienen in: Lasers in Medical Science 5/2017

12.04.2017 | Original Article

Calculus migration characterization during Ho:YAG laser lithotripsy by high-speed camera using suspended pendulum method

verfasst von: Jian James Zhang, Danop Rajabhandharaks, Jason Rongwei Xuan, Ray W. J. Chia, Thomas Hasenberg

Erschienen in: Lasers in Medical Science | Ausgabe 5/2017

Einloggen, um Zugang zu erhalten

Abstract

Calculus migration is a common problem during ureteroscopic laser lithotripsy procedure to treat urolithiasis. A conventional experimental method to characterize calculus migration utilized a hosting container (e.g., a “V” grove or a test tube). These methods, however, demonstrated large variation and poor detectability, possibly attributed to the friction between the calculus and the container on which the calculus was situated. In this study, calculus migration was investigated using a pendulum model suspended underwater to eliminate the aforementioned friction. A high-speed camera was used to study the movement of the calculus which covered zero order (displacement), first order (speed), and second order (acceleration). A commercialized, pulsed Ho:YAG laser at 2.1 μm, a 365-μm core diameter fiber, and a calculus phantom (Plaster of Paris, 10 × 10 × 10 mm3) was utilized to mimic laser lithotripsy procedure. The phantom was hung on a stainless steel bar and irradiated by the laser at 0.5, 1.0, and 1.5 J energy per pulse at 10 Hz for 1 s (i.e., 5, 10, and 15 W). Movement of the phantom was recorded by a high-speed camera with a frame rate of 10,000 FPS. The video data files are analyzed by MATLAB program by processing each image frame and obtaining position data of the calculus. With a sample size of 10, the maximum displacement was 1.25 ± 0.10, 3.01 ± 0.52, and 4.37 ± 0.58 mm for 0.5, 1, and 1.5 J energy per pulse, respectively. Using the same laser power, the conventional method showed <0.5 mm total displacement. When reducing the phantom size to 5 × 5 × 5 mm3 (one eighth in volume), the displacement was very inconsistent. The results suggested that using the pendulum model to eliminate the friction improved sensitivity and repeatability of the experiment. A detailed investigation on calculus movement and other causes of experimental variation will be conducted as a future study.
Literatur
1.
Zurück zum Zitat Kang HW, Lee H, Teichman JM, Oh J, Kim J, Welch AJ (2006) Dependence of calculus retropulsion on pulse duration during Ho: YAG laser lithotripsy. Lasers Surg Med 38:762–772CrossRefPubMed Kang HW, Lee H, Teichman JM, Oh J, Kim J, Welch AJ (2006) Dependence of calculus retropulsion on pulse duration during Ho: YAG laser lithotripsy. Lasers Surg Med 38:762–772CrossRefPubMed
2.
Zurück zum Zitat Kuznetsov LI (1993) Recoil momentum at a solid surface during developed laser ablation. Quantum Electron 23:1035–1038CrossRef Kuznetsov LI (1993) Recoil momentum at a solid surface during developed laser ablation. Quantum Electron 23:1035–1038CrossRef
3.
Zurück zum Zitat Foth HJ, Meyer D, Stockel T (2000) Side effects of laser tissue interaction studied by laser Doppler vibrometry. Proc SPIE 4072:392–400CrossRef Foth HJ, Meyer D, Stockel T (2000) Side effects of laser tissue interaction studied by laser Doppler vibrometry. Proc SPIE 4072:392–400CrossRef
4.
Zurück zum Zitat White MD, Moran ME, Calvano CJ, Borhan-Manesh A, Mehlhaff BA (1998) Evaluation of retropulsion caused by holmium:YAG laser with various power settings and fibers. J Endourol 12:183–186CrossRefPubMed White MD, Moran ME, Calvano CJ, Borhan-Manesh A, Mehlhaff BA (1998) Evaluation of retropulsion caused by holmium:YAG laser with various power settings and fibers. J Endourol 12:183–186CrossRefPubMed
5.
Zurück zum Zitat Lee H, Ryan RT, Kim JH, Choi B, Arakeri NV, Teichman JMH, Welch AJ (2004) Dependence of calculus retropulsion dynamics on fiber size and radiant exposure during Ho:YAG lithotripsy. J Biomed Eng 126:507–515 Lee H, Ryan RT, Kim JH, Choi B, Arakeri NV, Teichman JMH, Welch AJ (2004) Dependence of calculus retropulsion dynamics on fiber size and radiant exposure during Ho:YAG lithotripsy. J Biomed Eng 126:507–515
6.
Zurück zum Zitat Eisner BH, Pengune W, Stoller ML (2009) Use of an antiretropulsion device to prevent stone retropulsion significantly increases the efficiency of pneumatic lithotripsy: an in vitro study. BM Int 104:858–861 Eisner BH, Pengune W, Stoller ML (2009) Use of an antiretropulsion device to prevent stone retropulsion significantly increases the efficiency of pneumatic lithotripsy: an in vitro study. BM Int 104:858–861
7.
Zurück zum Zitat Robinson M, Teichman JMH (2013) Laser lithotripsy retropulsion varies with stone mass. Eur Urol Supp 12:e1063CrossRef Robinson M, Teichman JMH (2013) Laser lithotripsy retropulsion varies with stone mass. Eur Urol Supp 12:e1063CrossRef
8.
Zurück zum Zitat Finley DS, Petersen J, Abdelshehid C, Ahlering M, Chou D, Borin J, Eichel L, McDougall E, Clayman RV (2005) Effect of holmium:YAG laser pulse width on lithotripsy retropulsion in vitro. J Endourol 19:1041–1044CrossRefPubMed Finley DS, Petersen J, Abdelshehid C, Ahlering M, Chou D, Borin J, Eichel L, McDougall E, Clayman RV (2005) Effect of holmium:YAG laser pulse width on lithotripsy retropulsion in vitro. J Endourol 19:1041–1044CrossRefPubMed
9.
Zurück zum Zitat Lee HJ, Box GN, Abraham JB, Deane LA, Elchico ER, Eisner BH, McDougall EM, Clayman RV (2008) In vitro evaluation of nitinol urological retrieval coil and ureteral occlusion device: retropulsion and holmium laser fragmentation efficiency. J Urol 180:969–973CrossRefPubMed Lee HJ, Box GN, Abraham JB, Deane LA, Elchico ER, Eisner BH, McDougall EM, Clayman RV (2008) In vitro evaluation of nitinol urological retrieval coil and ureteral occlusion device: retropulsion and holmium laser fragmentation efficiency. J Urol 180:969–973CrossRefPubMed
10.
Zurück zum Zitat Marguet CG, Sung IC, Springhart WP, L'Esperance JO, Zhou S, Zhong P, Albala DM, Preminger GM (2005) In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse Nd:YAG laser and the holmium:YAG laser. J Urol 173:1797–1800CrossRefPubMed Marguet CG, Sung IC, Springhart WP, L'Esperance JO, Zhou S, Zhong P, Albala DM, Preminger GM (2005) In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse Nd:YAG laser and the holmium:YAG laser. J Urol 173:1797–1800CrossRefPubMed
11.
Zurück zum Zitat Sofer M, Watterson JD, Wollin TA, Nott L, Razvi H, Denstedt JD (2002) Holmium: YAG laser lithotripsy for upper urinary tract calculi in 598 patients. J Urol 167:31–34CrossRefPubMed Sofer M, Watterson JD, Wollin TA, Nott L, Razvi H, Denstedt JD (2002) Holmium: YAG laser lithotripsy for upper urinary tract calculi in 598 patients. J Urol 167:31–34CrossRefPubMed
12.
Zurück zum Zitat Cheung MC, Lee F, Yip SK, Tam PC (2001) Outpatient holmium laser lithotripsy using semirigid ureteroscope. Is the treatment outcome affected by stone load? Eur Urol 39:702–708CrossRefPubMed Cheung MC, Lee F, Yip SK, Tam PC (2001) Outpatient holmium laser lithotripsy using semirigid ureteroscope. Is the treatment outcome affected by stone load? Eur Urol 39:702–708CrossRefPubMed
13.
Zurück zum Zitat Lee H, Ryan RT, Teichman JM, Kim J, Choi B, Arakeri NV, Welch AJ (2003) Stone retropulsion during holmium:YAG lithotripsy. J Urol 169:881–885CrossRefPubMed Lee H, Ryan RT, Teichman JM, Kim J, Choi B, Arakeri NV, Welch AJ (2003) Stone retropulsion during holmium:YAG lithotripsy. J Urol 169:881–885CrossRefPubMed
14.
Zurück zum Zitat Rajabhandharaks D, Kang HW (2012) Short-pulsed Tm:YAG laser lithotripsy: comparative study on ablation performance with conventional Ho:YAG laser. SPIE Photonics West BIOS Conference 8207B-47, Session 4: Therapeutics and Diagnostics in Urology: Lasers, Robotics, Minimally Invasive, and Advanced Biomedical Devices Rajabhandharaks D, Kang HW (2012) Short-pulsed Tm:YAG laser lithotripsy: comparative study on ablation performance with conventional Ho:YAG laser. SPIE Photonics West BIOS Conference 8207B-47, Session 4: Therapeutics and Diagnostics in Urology: Lasers, Robotics, Minimally Invasive, and Advanced Biomedical Devices
15.
Zurück zum Zitat Sroka R, Haseke N, Pongratz T, Hecht V, Tilld D, Stief CG, Bader MJ (2012) In vitro investigations of repulsion during laser lithotripsy using a pendulum set-up. Lasers Med Sci 27:637–643CrossRefPubMed Sroka R, Haseke N, Pongratz T, Hecht V, Tilld D, Stief CG, Bader MJ (2012) In vitro investigations of repulsion during laser lithotripsy using a pendulum set-up. Lasers Med Sci 27:637–643CrossRefPubMed
16.
Zurück zum Zitat Carey RI, Kyle CC, Carey DL, Leveillee RJ (2008) Preparation of artificial kidney stones of reproducible size, shape, and mass by precision injection molding. J Endourol 22:127–131CrossRefPubMed Carey RI, Kyle CC, Carey DL, Leveillee RJ (2008) Preparation of artificial kidney stones of reproducible size, shape, and mass by precision injection molding. J Endourol 22:127–131CrossRefPubMed
17.
Zurück zum Zitat Delvecchio FC, Auge BK, Brizuela RM, Weizer AZ, Zhong P, Preminger GM (2004) In vitro analysis of stone fragmentation ability of the FREDDY laser. J Endourol 17:177–179CrossRef Delvecchio FC, Auge BK, Brizuela RM, Weizer AZ, Zhong P, Preminger GM (2004) In vitro analysis of stone fragmentation ability of the FREDDY laser. J Endourol 17:177–179CrossRef
18.
Zurück zum Zitat Vassar GJ, Chan KF, Teichman JMH, Glickman RD, Weintraub ST, Pfefer TJ, Welch AJ (1999) Holmium:YAG lithotripsy: photothermal mechanism. J Endourol 13:181–190CrossRefPubMed Vassar GJ, Chan KF, Teichman JMH, Glickman RD, Weintraub ST, Pfefer TJ, Welch AJ (1999) Holmium:YAG lithotripsy: photothermal mechanism. J Endourol 13:181–190CrossRefPubMed
19.
Zurück zum Zitat Blackmon RL, Irby PB, Fried NM (2011) Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects. J Biomed Opt 16:071403CrossRefPubMed Blackmon RL, Irby PB, Fried NM (2011) Comparison of holmium:YAG and thulium fiber laser lithotripsy: ablation thresholds, ablation rates, and retropulsion effects. J Biomed Opt 16:071403CrossRefPubMed
Metadaten
Titel
Calculus migration characterization during Ho:YAG laser lithotripsy by high-speed camera using suspended pendulum method
verfasst von
Jian James Zhang
Danop Rajabhandharaks
Jason Rongwei Xuan
Ray W. J. Chia
Thomas Hasenberg
Publikationsdatum
12.04.2017
Verlag
Springer London
Erschienen in
Lasers in Medical Science / Ausgabe 5/2017
Print ISSN: 0268-8921
Elektronische ISSN: 1435-604X
DOI
https://doi.org/10.1007/s10103-017-2202-1

Weitere Artikel der Ausgabe 5/2017

Lasers in Medical Science 5/2017 Zur Ausgabe