Skip to main content
Erschienen in: Emergency Radiology 6/2013

01.12.2013 | Original Article

Radiation exposure among patients with the highest CT scan utilization in the emergency department

verfasst von: Kaushal H. Shah, Benjamin H. Slovis, Dan Runde, Brandon Godbout, David H. Newman, Jarone Lee

Erschienen in: Emergency Radiology | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

The risk of cancer from computed tomography (CT) scan radiation is a rising concern in the medical field. Our objectives were to determine how many patients received more than ten CT scans in an academic emergency department (ED) over the course of 7 years and to quantify their radiation exposure and lifetime attributable risk of cancer. An electronic chart review was performed at our urban academic institution with an annual census of 110,000 patients. All patients who underwent a CT scan performed during ED management between the dates of January 2001 and December 2007 were identified. Specific predetermined data elements (e.g., subject demographics, type of CT scan) were extracted by two researchers blinded to hypothesis, using a preformatted data form. After identifying patients with more than ten CTs performed during the study period, radiation exposure was calculated based on accepted and reported radiation doses for the respective anatomic CTs, and lifetime attributable cancer risk was calculated based on the seventh report of the Biological Effects of Ionizing Radiation (BEIR VII) projections. Over the 7-year study period, 24,393 patients received 34,671 CT scans. The vast majority of patients (17,909) received a single CT. Twenty-six (0.1 %) patients received more than ten CTs totaling 374 scans with an average radiation exposure of 83.4 mSv. The maximum lifetime attributable risk for any individual in this cohort was 1.7 % above the baseline cancer risk. Among those undergoing CT imaging in our ED, high-exposure patients (greater than ten scans) constituted a significant minority, while more than one in four patients underwent more than one CT scan during the study period. While the presumed overall risk of radiation-induced cancer continues to be low, it is important for the emergency physician to use clinical knowledge as well as concern for the patient when utilizing radiographic imaging. Increasing attributable cancer risk may have important public health implications in the future, regardless of the low individual risk.
Literatur
1.
Zurück zum Zitat Brenner DJ, Elliston CD (2004) Estimated radiation risks potentially associated with full-body CT screening. Radiology 232(3):735–738PubMedCrossRef Brenner DJ, Elliston CD (2004) Estimated radiation risks potentially associated with full-body CT screening. Radiology 232(3):735–738PubMedCrossRef
2.
Zurück zum Zitat Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284PubMedCrossRef Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284PubMedCrossRef
3.
Zurück zum Zitat Berrington de Gonzalez A, Mahesh M, Kim KP et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169(22):2071–2077PubMedCrossRef Berrington de Gonzalez A, Mahesh M, Kim KP et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169(22):2071–2077PubMedCrossRef
4.
Zurück zum Zitat Lee J, Kirschner J, Pawa S, Wiener DE, Newman DH, Shah K (2010) Computed tomography use in the adult emergency department of an academic urban hospital from 2001 to 2007. Ann Emerg Med 56(6):591–596PubMedCrossRef Lee J, Kirschner J, Pawa S, Wiener DE, Newman DH, Shah K (2010) Computed tomography use in the adult emergency department of an academic urban hospital from 2001 to 2007. Ann Emerg Med 56(6):591–596PubMedCrossRef
5.
Zurück zum Zitat Stern SH, Kaczmarek RV, Spelic DC, Suleiman OH (2001) Nationwide Evaluation of X-ray Trends (NEXT): 2000–2001 survey of patient radiation exposure from computed tomographic (CT) examinations in the United States. Radiology 221:161 Stern SH, Kaczmarek RV, Spelic DC, Suleiman OH (2001) Nationwide Evaluation of X-ray Trends (NEXT): 2000–2001 survey of patient radiation exposure from computed tomographic (CT) examinations in the United States. Radiology 221:161
6.
Zurück zum Zitat National Research Council (U.S.) and Committee to Assess Health Risks from Exposure to Low Level of Ionizing Radiation (2006) Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase 2. National Academies, Washington, D.C National Research Council (U.S.) and Committee to Assess Health Risks from Exposure to Low Level of Ionizing Radiation (2006) Health risks from exposure to low levels of ionizing radiation: BEIR VII Phase 2. National Academies, Washington, D.C
7.
Zurück zum Zitat Griffey RT, Sodickson A (2009) Cumulative radiation exposure and cancer risk estimates in emergency department patients undergoing repeat or multiple CT. AJR Am J Roentgenol 192(4):887–892PubMedCrossRef Griffey RT, Sodickson A (2009) Cumulative radiation exposure and cancer risk estimates in emergency department patients undergoing repeat or multiple CT. AJR Am J Roentgenol 192(4):887–892PubMedCrossRef
8.
Zurück zum Zitat Sodickson A, Baeyens PF, Andriole KP et al (2009) Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology 251(1):175–184PubMedCrossRef Sodickson A, Baeyens PF, Andriole KP et al (2009) Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology 251(1):175–184PubMedCrossRef
9.
Zurück zum Zitat Romano S, Romano L (2010) Utilization patterns of multidetector computed tomography in elective and emergency conditions: indications, exposure risk, and diagnostic gain. Semin Ultrasound CT MR 31(1):53–56PubMedCrossRef Romano S, Romano L (2010) Utilization patterns of multidetector computed tomography in elective and emergency conditions: indications, exposure risk, and diagnostic gain. Semin Ultrasound CT MR 31(1):53–56PubMedCrossRef
10.
Zurück zum Zitat Weiss CR, Scatarige JC, Diette GB, Haponik EF, Merriman B, Fishman EK (2006) CT pulmonary angiography is the first-line imaging test for acute pulmonary embolism: a survey of US clinicians. Acad Radiol 13(4):434–446PubMedCrossRef Weiss CR, Scatarige JC, Diette GB, Haponik EF, Merriman B, Fishman EK (2006) CT pulmonary angiography is the first-line imaging test for acute pulmonary embolism: a survey of US clinicians. Acad Radiol 13(4):434–446PubMedCrossRef
11.
Zurück zum Zitat Ahmed F, Zafar AM, Khan N, Haider Z, Ather MH (2010) A paradigm shift in imaging for renal colic—is it time to say good bye to an old trusted friend? Int J Surg 8(3):252–256PubMedCrossRef Ahmed F, Zafar AM, Khan N, Haider Z, Ather MH (2010) A paradigm shift in imaging for renal colic—is it time to say good bye to an old trusted friend? Int J Surg 8(3):252–256PubMedCrossRef
12.
Zurück zum Zitat Bailitz J, Starr F, Beecroft M et al (2009) CT should replace three-view radiographs as the initial screening test in patients at high, moderate, and low risk for blunt cervical spine injury: a prospective comparison. J Trauma 66(6):1605–1609PubMedCrossRef Bailitz J, Starr F, Beecroft M et al (2009) CT should replace three-view radiographs as the initial screening test in patients at high, moderate, and low risk for blunt cervical spine injury: a prospective comparison. J Trauma 66(6):1605–1609PubMedCrossRef
13.
Zurück zum Zitat Mathen R, Inaba K, Munera F et al (2007) Prospective evaluation of multislice computed tomography versus plain radiographic cervical spine clearance in trauma patients. J Trauma 62(6):1427–1431PubMedCrossRef Mathen R, Inaba K, Munera F et al (2007) Prospective evaluation of multislice computed tomography versus plain radiographic cervical spine clearance in trauma patients. J Trauma 62(6):1427–1431PubMedCrossRef
14.
Zurück zum Zitat Broder J, Warshauer DM (2006) Increasing utilization of computed tomography in the adult emergency department, 2000–2005. Emerg Radiol 13(1):25–30PubMedCrossRef Broder J, Warshauer DM (2006) Increasing utilization of computed tomography in the adult emergency department, 2000–2005. Emerg Radiol 13(1):25–30PubMedCrossRef
15.
Zurück zum Zitat Boone JM, Brunberg JA (2008) Computed tomography use in a tertiary care university hospital. J Am Coll Radiol JACR 5(2):132–138CrossRef Boone JM, Brunberg JA (2008) Computed tomography use in a tertiary care university hospital. J Am Coll Radiol JACR 5(2):132–138CrossRef
16.
Zurück zum Zitat Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248(1):254–263PubMedCrossRef Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248(1):254–263PubMedCrossRef
17.
Zurück zum Zitat Preston DL, Pierce DA, Shimizu Y, Ron E, Mabuchi K (2003) Dose response and temporal patterns of radiation-associated solid cancer risks. Heal Phys 85(1):43–46CrossRef Preston DL, Pierce DA, Shimizu Y, Ron E, Mabuchi K (2003) Dose response and temporal patterns of radiation-associated solid cancer risks. Heal Phys 85(1):43–46CrossRef
18.
Zurück zum Zitat Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154(2):178–186PubMedCrossRef Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154(2):178–186PubMedCrossRef
19.
Zurück zum Zitat Preston DL, Ron E, Tokuoka S et al (2007) Solid cancer incidence in atomic bomb survivors: 1958–1998. Radiat Res 168(1):1–64PubMedCrossRef Preston DL, Ron E, Tokuoka S et al (2007) Solid cancer incidence in atomic bomb survivors: 1958–1998. Radiat Res 168(1):1–64PubMedCrossRef
20.
Zurück zum Zitat Cardis E, Vrijheid M, Blettner M et al (2005) Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries. BMJ 331(7508):77PubMedCrossRef Cardis E, Vrijheid M, Blettner M et al (2005) Risk of cancer after low doses of ionising radiation: retrospective cohort study in 15 countries. BMJ 331(7508):77PubMedCrossRef
21.
Zurück zum Zitat Cardis E, Vrijheid M, Blettner M et al (2007) The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: estimates of radiation-related cancer risks. Radiat Res 167(4):396–416PubMedCrossRef Cardis E, Vrijheid M, Blettner M et al (2007) The 15-Country Collaborative Study of Cancer Risk among Radiation Workers in the Nuclear Industry: estimates of radiation-related cancer risks. Radiat Res 167(4):396–416PubMedCrossRef
22.
Zurück zum Zitat Hendee WR, O'Connor MK (2012) Radiation risks of medical imaging: separating fact from fantasy. Radiology 264(2):312–321PubMedCrossRef Hendee WR, O'Connor MK (2012) Radiation risks of medical imaging: separating fact from fantasy. Radiology 264(2):312–321PubMedCrossRef
23.
Zurück zum Zitat Tubiana M, Feinendegen LE, Yang C, Kaminski JM (2009) The linear no-threshold relationship is inconsistent with radiation biologic and experimental data. Radiology 251(1):13–22PubMedCrossRef Tubiana M, Feinendegen LE, Yang C, Kaminski JM (2009) The linear no-threshold relationship is inconsistent with radiation biologic and experimental data. Radiology 251(1):13–22PubMedCrossRef
24.
Zurück zum Zitat Scott BR (2008) Low-dose radiation risk extrapolation fallacy associated with the linear-no-threshold model. Hum Exp Toxicol 27(2):163–168PubMedCrossRef Scott BR (2008) Low-dose radiation risk extrapolation fallacy associated with the linear-no-threshold model. Hum Exp Toxicol 27(2):163–168PubMedCrossRef
25.
Zurück zum Zitat Smith-Bindman R, Lipson J, Marcus R et al (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169(22):2078–2086PubMedCrossRef Smith-Bindman R, Lipson J, Marcus R et al (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169(22):2078–2086PubMedCrossRef
26.
Zurück zum Zitat Motaganahalli R, Martin A, Feliciano B, Murphy MP, Slaven J, Dalsing MC (2012) Estimating the risk of solid organ malignancy in patients undergoing routine computed tomography scans after endovascular aneurysm repair. J Vasc Surg 56(4):929–937PubMedCrossRef Motaganahalli R, Martin A, Feliciano B, Murphy MP, Slaven J, Dalsing MC (2012) Estimating the risk of solid organ malignancy in patients undergoing routine computed tomography scans after endovascular aneurysm repair. J Vasc Surg 56(4):929–937PubMedCrossRef
27.
Zurück zum Zitat Howlader N NA, Krapcho M, Neyman N, Aminou R, Waldron W, Altekruse SF, Kosary CL, Ruhl J, Tatalovich Z, Cho H, Mariotto A, Eisner MP, Lewis DR, Chen HS, Feuer EJ, Cronin KA (eds) (2012) SEER Cancer Statistics Review, 1975–2009 (Vintage 2009 Populations), National Cancer Institute. Bethesda, MD. http://seer.cancer.gov/csr/1975_2009_pops09/, based on November 2011 SEER data submission, posted to the SEER web site. Accessed 19 Apr 2013 Howlader N NA, Krapcho M, Neyman N, Aminou R, Waldron W, Altekruse SF, Kosary CL, Ruhl J, Tatalovich Z, Cho H, Mariotto A, Eisner MP, Lewis DR, Chen HS, Feuer EJ, Cronin KA (eds) (2012) SEER Cancer Statistics Review, 1975–2009 (Vintage 2009 Populations), National Cancer Institute. Bethesda, MD. http://​seer.​cancer.​gov/​csr/​1975_​2009_​pops09/​, based on November 2011 SEER data submission, posted to the SEER web site. Accessed 19 Apr 2013
28.
Zurück zum Zitat Brenner DJ (2010) Slowing the increase in the population dose resulting from CT scans. Radiat Res 174(6):809–815PubMedCrossRef Brenner DJ (2010) Slowing the increase in the population dose resulting from CT scans. Radiat Res 174(6):809–815PubMedCrossRef
29.
Zurück zum Zitat United Nations (2010) Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation: United Nations Scientific Committee on the Effects of Atomic Radiation: UNSCEAR 2008 report to the General Assembly, with scientific annexes. United Nations, New York United Nations (2010) Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation: United Nations Scientific Committee on the Effects of Atomic Radiation: UNSCEAR 2008 report to the General Assembly, with scientific annexes. United Nations, New York
30.
Zurück zum Zitat ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 37(2–4):1–332 ICRP (2007) The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. Ann ICRP 37(2–4):1–332
31.
Zurück zum Zitat McNitt-Gray MF (2002) AAPM/RSNA Physics tutorial for residents: topics in CT. Radiation dose in CT. Radiographics RevPubl Radiol Soc N Am Inc 22(6):1541–1553 McNitt-Gray MF (2002) AAPM/RSNA Physics tutorial for residents: topics in CT. Radiation dose in CT. Radiographics RevPubl Radiol Soc N Am Inc 22(6):1541–1553
32.
Zurück zum Zitat Baker KS, Shaikh MB, Gould ES, Yang J, Chen J, Bonvento M (2012) Evaluation of radiation dose among patients admitted through a university hospital emergency department. Emerg Radiol 19(6):505–512PubMedCrossRef Baker KS, Shaikh MB, Gould ES, Yang J, Chen J, Bonvento M (2012) Evaluation of radiation dose among patients admitted through a university hospital emergency department. Emerg Radiol 19(6):505–512PubMedCrossRef
33.
Zurück zum Zitat Martin CJ (2007) Effective dose: how should it be applied to medical exposures? Br J Radiol 80(956):639–647PubMedCrossRef Martin CJ (2007) Effective dose: how should it be applied to medical exposures? Br J Radiol 80(956):639–647PubMedCrossRef
Metadaten
Titel
Radiation exposure among patients with the highest CT scan utilization in the emergency department
verfasst von
Kaushal H. Shah
Benjamin H. Slovis
Dan Runde
Brandon Godbout
David H. Newman
Jarone Lee
Publikationsdatum
01.12.2013
Verlag
Springer Berlin Heidelberg
Erschienen in
Emergency Radiology / Ausgabe 6/2013
Print ISSN: 1070-3004
Elektronische ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-013-1142-8

Weitere Artikel der Ausgabe 6/2013

Emergency Radiology 6/2013 Zur Ausgabe

ACKNOWLEDGEMENT TO REVIEWERS

Recognition of our outstanding reviewers

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.