Skip to main content
Erschienen in: Emergency Radiology 2/2017

01.04.2017 | Original Article

Utility of contemporaneous dual read in the setting of emergency teleradiology reporting

verfasst von: Anjali Agrawal, D B Koundinya, Jayadeepa Srinivas Raju, Anurag Agrawal, Arjun Kalyanpur

Erschienen in: Emergency Radiology | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Emergency radiology requires rapid and accurate interpretation of imaging examinations. Missed findings may lead to adverse outcomes. Double reporting may be used to minimize errors. Limited contemporaneous double reporting may be most efficient and cost-effective, but no data exists. This study is intended to examine the benefits of double reading and identify examinations where this would be most useful.

Methods

In this study, dual reporting was conducted in a parallel reading environment in a teleradiology practice for 3779 radiological procedures performed at two radiology centers in the USA over a period of 4 months. Discrepancies between reads were scored using the ACR peer review scoring system and grouped by modality and body part. Errors were tabulated across the study types, followed by identification of statistically significant differences. The interaction between image number and odds of an error was ascertained.

Results

In 145 instances (3.8%; 95 % CI, 3.2–4.4%), double reporting identified errors, leading to report modification. Study type was significantly related to error frequency (p = 0.0001), with higher than average frequencies of error seen for CT abdomen and pelvis and MRI head or spine, but lower than average for CT head, CT spine, and ultrasound. Image number was positively associated with error odds, but was not independently significant in a joint logistic regression model that included study type.

Conclusion

Dual reporting identifies missed findings in about 1 of 25 emergency studies. This benefit varies substantially across study types and limited double reporting, merits further investigation as a cost-effective practice improvement strategy.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
5.
7.
Zurück zum Zitat Markus JB, Somers S, O’Malley BP, Stevenson GW (1990) Double-contrast barium enema studies: effect of multiple reading on perception error. Radiology 175:155–156CrossRefPubMed Markus JB, Somers S, O’Malley BP, Stevenson GW (1990) Double-contrast barium enema studies: effect of multiple reading on perception error. Radiology 175:155–156CrossRefPubMed
8.
13.
Zurück zum Zitat Agrawal A, Kalyanpur A (2012) Synchronizing computer clocks: the challenge of multiple time zones in teleradiology. Indian J Radiol Imaging 22:240 Agrawal A, Kalyanpur A (2012) Synchronizing computer clocks: the challenge of multiple time zones in teleradiology. Indian J Radiol Imaging 22:240
16.
Zurück zum Zitat Halsted MJ, Donnelly LF, Strife JL (2005) Radiologist recruitment and retention:how can we improve? J Am Coll Radiol 2(4):p369–p375CrossRef Halsted MJ, Donnelly LF, Strife JL (2005) Radiologist recruitment and retention:how can we improve? J Am Coll Radiol 2(4):p369–p375CrossRef
17.
Zurück zum Zitat Arl VM, Allen B, Campbell SC, Carlson RA, Dunnick NR, Fletcher TB, Hanks JD, Hauser JB, Moorefield JM, Taxin RN, Thrall JH (2005) Report of the ACR task force on international teleradiology. J Am Coll Radiol 2:121–125. doi:10.1016/j.jacr.2004.08.003 CrossRef Arl VM, Allen B, Campbell SC, Carlson RA, Dunnick NR, Fletcher TB, Hanks JD, Hauser JB, Moorefield JM, Taxin RN, Thrall JH (2005) Report of the ACR task force on international teleradiology. J Am Coll Radiol 2:121–125. doi:10.​1016/​j.​jacr.​2004.​08.​003 CrossRef
19.
Zurück zum Zitat Silva E, Breslau J, Barr RM, Liebscher LA, Bohl M, Hoffman T, Boland GWL, Sherry C, Kim W, Shah SS, Tilkin M (2013) ACR white paper on teleradiology practice: a report from the Task Force on Teleradiology Practice. Journal of the American College of Radiology: JACR 10:575–585. doi:10.1016/j.jacr.2013.03.018 CrossRefPubMed Silva E, Breslau J, Barr RM, Liebscher LA, Bohl M, Hoffman T, Boland GWL, Sherry C, Kim W, Shah SS, Tilkin M (2013) ACR white paper on teleradiology practice: a report from the Task Force on Teleradiology Practice. Journal of the American College of Radiology: JACR 10:575–585. doi:10.​1016/​j.​jacr.​2013.​03.​018 CrossRefPubMed
20.
21.
Zurück zum Zitat Johnson CD, Harmsen WS, Wilson LA, Maccarty RL, Welch TJ, Ilstrup DM, Ahlquist DA (2003) Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps. Gastroenterology 125:311–319. doi:10.1016/S0016-5085(03)00894-1 CrossRefPubMed Johnson CD, Harmsen WS, Wilson LA, Maccarty RL, Welch TJ, Ilstrup DM, Ahlquist DA (2003) Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polyps. Gastroenterology 125:311–319. doi:10.​1016/​S0016-5085(03)00894-1 CrossRefPubMed
23.
Zurück zum Zitat Borgstede JP, Lewis RS, Bhargavan M, Sunshine JH (2004) RADPEER quality assurance program: a multifacility study of interpretive disagreement rates. J Am Coll Radiol. doi:10.1016/S1546-1440(03)00002-4 Borgstede JP, Lewis RS, Bhargavan M, Sunshine JH (2004) RADPEER quality assurance program: a multifacility study of interpretive disagreement rates. J Am Coll Radiol. doi:10.​1016/​S1546-1440(03)00002-4
24.
Metadaten
Titel
Utility of contemporaneous dual read in the setting of emergency teleradiology reporting
verfasst von
Anjali Agrawal
D B Koundinya
Jayadeepa Srinivas Raju
Anurag Agrawal
Arjun Kalyanpur
Publikationsdatum
01.04.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Emergency Radiology / Ausgabe 2/2017
Print ISSN: 1070-3004
Elektronische ISSN: 1438-1435
DOI
https://doi.org/10.1007/s10140-016-1465-3

Weitere Artikel der Ausgabe 2/2017

Emergency Radiology 2/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.