Acoustic to Electric Pitch Comparisons in Cochlear Implant Subjects with Residual Hearing

verfasst von: Colette Boëx, Lionel Baud, Grégoire Cosendai, Alain Sigrist, Maria-Izabel Kós, Marco Pelizzone

Erschienen in: Journal of the Association for Research in Otolaryngology | Ausgabe 2/2006

Einloggen, um Zugang zu erhalten

Abstract

The aim of this study was to assess the frequency–position function resulting from electric stimulation of electrodes in cochlear implant subjects with significant residual hearing in their nonimplanted ear. Six cochlear implant users compared the pitch of the auditory sensation produced by stimulation of an intracochlear electrode to the pitch of acoustic pure tones presented to their contralateral nonimplanted ear. Subjects were implanted with different Clarion® electrode arrays, designed to lie close to the inner wall of the cochlea. High-resolution radiographs were used to determine the electrode positions in the cochlea. Four out of six subjects presented electrode insertions deeper than 450°. We used a two-interval (one acoustic, one electric), two-alternative forced choice protocol (2I-2AFC), asking the subject to indicate which stimulus sounded the highest in pitch. Pure tones were used as acoustic stimuli. Electric stimuli consisted of trains of biphasic pulses presented at relatively high rates [higher than 700 pulses per second (pps)]. First, all electric stimuli were balanced in loudness across electrodes. Second, acoustic pure tones, chosen to approximate roughly the pitch sensation produced by each electrode, were balanced in loudness to electric stimuli. When electrode insertion lengths were used to describe electrode positions, the pitch sensations produced by electric stimulation were found to be more than two octaves lower than predicted by Greenwood's frequency–position function. When insertion angles were used to describe electrode positions, the pitch sensations were found about one octave lower than the frequency–position function of a normal ear. The difference found between both descriptions is because of the fact that these electrode arrays were designed to lie close to the modiolus. As a consequence, the site of excitation produced at the level of the organ of Corti corresponds to a longer length than the electrode insertion length, which is used in Greenwood's function. Although exact measurements of the round window position as well as the length of the cochlea could explain the remaining one octave difference found when insertion angles were used, physiological phenomena (e.g., stimulation of the spiral ganglion cells) could also create this difference. From these data, analysis filters could be determined in sound coding strategies to match the pitch percepts elicited by electrode stimulation. This step might be of main importance for music perception and for the fitting of bilateral cochlear implants.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
Zurück zum Zitat Bilger RC. Psychoacoustic evaluation of present prostheses. Ann. Otol. Rhinol. Laryngol. 86(Suppl. 38):92–140, 1977. Bilger RC. Psychoacoustic evaluation of present prostheses. Ann. Otol. Rhinol. Laryngol. 86(Suppl. 38):92–140, 1977.
Zurück zum Zitat Blamey PJ, Dooley GJ, Parisi ES, Clark GM. Pitch comparisons of acoustically and electrically evoked auditory sensations. Hear. Res. 99:139–150, 1996.CrossRefPubMed Blamey PJ, Dooley GJ, Parisi ES, Clark GM. Pitch comparisons of acoustically and electrically evoked auditory sensations. Hear. Res. 99:139–150, 1996.CrossRefPubMed
Zurück zum Zitat Boëx C, de Balthasar C, Kós M-I, Pelizzone M. Electrical field interactions in different cochlear implant systems. J. Acoust. Soc. Am. 114(4):2049–2057, 2003a.CrossRefPubMed Boëx C, de Balthasar C, Kós M-I, Pelizzone M. Electrical field interactions in different cochlear implant systems. J. Acoust. Soc. Am. 114(4):2049–2057, 2003a.CrossRefPubMed
Zurück zum Zitat Busby PA, Clark GM. Pitch and loudness estimation for single andmultiple pulse per period electric pulse rates by cochlearimplant patients. J. Acoust. Soc. Am. 101(3):1687–1695, 1997.CrossRefPubMed Busby PA, Clark GM. Pitch and loudness estimation for single andmultiple pulse per period electric pulse rates by cochlearimplant patients. J. Acoust. Soc. Am. 101(3):1687–1695, 1997.CrossRefPubMed
Zurück zum Zitat Busby PA, Whitford LA, Blamey PJ, Richardson LM, Clark GM. Pitch perception for different modes of stimulation using the cochlear multiple-electrode prosthesis. J. Acoust. Soc. Am. 95:2658–2669, 1994.CrossRefPubMed Busby PA, Whitford LA, Blamey PJ, Richardson LM, Clark GM. Pitch perception for different modes of stimulation using the cochlear multiple-electrode prosthesis. J. Acoust. Soc. Am. 95:2658–2669, 1994.CrossRefPubMed
Zurück zum Zitat Clark GM, Shepherd RK, Franz BK-H, Dowell RC et al. The histopathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient. Correlation with psychophysics and speech perception results. Acta Oto-laryngol. (Stockh.). 448:1–65, 1988.CrossRef Clark GM, Shepherd RK, Franz BK-H, Dowell RC et al. The histopathology of the human temporal bone and auditory central nervous system following cochlear implantation in a patient. Correlation with psychophysics and speech perception results. Acta Oto-laryngol. (Stockh.). 448:1–65, 1988.CrossRef
Zurück zum Zitat Cohen LT, Busby PA, Whitford LA, Clark GM. Cochlear implant place psychophysics. 1. Pitch estimation with deeply inserted electrodes. Audiol. Neuro-Otol. 1:265–277, 1996a. Cohen LT, Busby PA, Whitford LA, Clark GM. Cochlear implant place psychophysics. 1. Pitch estimation with deeply inserted electrodes. Audiol. Neuro-Otol. 1:265–277, 1996a.
Zurück zum Zitat Cohen LT, Xu J, Xu SA, Clark GM. Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array. Am. J. Otol. 17:859–865, 1996b.PubMed Cohen LT, Xu J, Xu SA, Clark GM. Improved and simplified methods for specifying positions of the electrode bands of a cochlear implant array. Am. J. Otol. 17:859–865, 1996b.PubMed
Zurück zum Zitat Collins LM, Throckmorton CS. Investigating perceptual features of electrode stimulation via a multidimensional scaling paradigm. J. Acoust. Soc. Am. 108(5):2353–2365, 2000.PubMedCrossRef Collins LM, Throckmorton CS. Investigating perceptual features of electrode stimulation via a multidimensional scaling paradigm. J. Acoust. Soc. Am. 108(5):2353–2365, 2000.PubMedCrossRef
Zurück zum Zitat Collins LM, Zwolan TA, Wakefield GH. Comparison of electrode discrimination, pitch ranking, and pitch scaling data in postlingually deafened adult cochlear implant subjects. J. Acoust. Soc. Am. 101(1):440–455, 1997.CrossRefPubMed Collins LM, Zwolan TA, Wakefield GH. Comparison of electrode discrimination, pitch ranking, and pitch scaling data in postlingually deafened adult cochlear implant subjects. J. Acoust. Soc. Am. 101(1):440–455, 1997.CrossRefPubMed
Zurück zum Zitat Dorman MF, Smith L, McCandless G, Dunnavant G, Parkin J, Dankowski K. Pitch scaling and speech understanding by patients who use the Ineraid cochlear implant. Ear Hear. 11:310–315, 1990.PubMed Dorman MF, Smith L, McCandless G, Dunnavant G, Parkin J, Dankowski K. Pitch scaling and speech understanding by patients who use the Ineraid cochlear implant. Ear Hear. 11:310–315, 1990.PubMed
Zurück zum Zitat Dorman MF, Smith M, Smith L, Parkin JL. The pitch of electrically presented sinusoids. J. Acoust. Soc. Am. 95(3):1677–1679, 1994.CrossRefPubMed Dorman MF, Smith M, Smith L, Parkin JL. The pitch of electrically presented sinusoids. J. Acoust. Soc. Am. 95(3):1677–1679, 1994.CrossRefPubMed
Zurück zum Zitat Eddington DK. Speech discrimination in deaf subjects with cochlear implants. J. Acoust. Soc. Am. 68:885–891, 1980.CrossRefPubMed Eddington DK. Speech discrimination in deaf subjects with cochlear implants. J. Acoust. Soc. Am. 68:885–891, 1980.CrossRefPubMed
Zurück zum Zitat Eddington DK, Dobelle WH, Brackmann DE, Mladejovsky MG, Parkin JL. Place and periodicity pitch by stimulation of multiple scala tympani electrodes in deaf volunteers. Trans. – Am. Soc. Artif. Intern. Organs XXIV:1–5, 1978a. Eddington DK, Dobelle WH, Brackmann DE, Mladejovsky MG, Parkin JL. Place and periodicity pitch by stimulation of multiple scala tympani electrodes in deaf volunteers. Trans. – Am. Soc. Artif. Intern. Organs XXIV:1–5, 1978a.
Zurück zum Zitat Eddington DK, Dobelle WH, Brackmann DE, Mladejovsky MG, Parkin JL. Auditory prostheses research with multiple channel intracochlear stimulation in man. Ann. Otol. Rhinol. Laryngol. 87(6, part 2, Suppl. 53):1–39, 1978b.PubMed Eddington DK, Dobelle WH, Brackmann DE, Mladejovsky MG, Parkin JL. Auditory prostheses research with multiple channel intracochlear stimulation in man. Ann. Otol. Rhinol. Laryngol. 87(6, part 2, Suppl. 53):1–39, 1978b.PubMed
Zurück zum Zitat Fayad JN, Luxford W, Linthicum FH. The Clarion electrode positioner: temporal bone studies. Am. J. Otol. 21:226–229, 2000.CrossRefPubMed Fayad JN, Luxford W, Linthicum FH. The Clarion electrode positioner: temporal bone studies. Am. J. Otol. 21:226–229, 2000.CrossRefPubMed
Zurück zum Zitat Fayad J, Linthicium FH Jr, Galey FR, Otto SR, House WF. Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann. Otol. Rhinol. Laryngol. 100:807–811, 1991.PubMed Fayad J, Linthicium FH Jr, Galey FR, Otto SR, House WF. Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann. Otol. Rhinol. Laryngol. 100:807–811, 1991.PubMed
Zurück zum Zitat Frinjs JHM, Briaire JJ, Grote JJ. The importance of human cochlear anatomy for the results of the modiolus-hugging multichannel cochlear implants. Otol. Neurotol. 22:340–349, 2001.PubMedCrossRef Frinjs JHM, Briaire JJ, Grote JJ. The importance of human cochlear anatomy for the results of the modiolus-hugging multichannel cochlear implants. Otol. Neurotol. 22:340–349, 2001.PubMedCrossRef
Zurück zum Zitat Galey FR. Initial observations of a human temporal bone with a multi-channel implant. Acta Otol. (Stockh). 411(Suppl.):38–44, 1984. Galey FR. Initial observations of a human temporal bone with a multi-channel implant. Acta Otol. (Stockh). 411(Suppl.):38–44, 1984.
Zurück zum Zitat Greenwood DD. Critical bandwidth and frequency coordinates ofthe basilar membrane. J. Acoust. Soc. Am. 33:1344–1356, 1961.CrossRef Greenwood DD. Critical bandwidth and frequency coordinates ofthe basilar membrane. J. Acoust. Soc. Am. 33:1344–1356, 1961.CrossRef
Zurück zum Zitat Greenwood DD. A cochlear frequency–position function for several species—29 years later. J. Acoust. Soc. Am. 87(6):2592–2605, 1990.CrossRefPubMed Greenwood DD. A cochlear frequency–position function for several species—29 years later. J. Acoust. Soc. Am. 87(6):2592–2605, 1990.CrossRefPubMed
Zurück zum Zitat James C, Blamey P, Shallop JK, Incerti PV, Nicholas AM. Contralateral masking in cochlear implant users with residual hearing in the non-implanted ear. Audiol. Neuro-otol. 6:87–97, 2001.CrossRef James C, Blamey P, Shallop JK, Incerti PV, Nicholas AM. Contralateral masking in cochlear implant users with residual hearing in the non-implanted ear. Audiol. Neuro-otol. 6:87–97, 2001.CrossRef
Zurück zum Zitat Johnson LG, House WF, Linthicium FH Jr. Otopathological findings in a patient with bilateral cochlear implants. Ann. Otol. Rhinol. Laryngol., Suppl. 91(2, Part 3):74–89, 1982. Johnson LG, House WF, Linthicium FH Jr. Otopathological findings in a patient with bilateral cochlear implants. Ann. Otol. Rhinol. Laryngol., Suppl. 91(2, Part 3):74–89, 1982.
Zurück zum Zitat Kawano A, Seldon HL, Clark GM. Computer-aided three-dimensional reconstruction in human cochlear maps: measurement of the lengths of organ of Corti, outer wall, inner wall and Rosenthal's canal. Ann. Otol. Rhinol. Laryngol. 105:701–709, 1996.PubMed Kawano A, Seldon HL, Clark GM. Computer-aided three-dimensional reconstruction in human cochlear maps: measurement of the lengths of organ of Corti, outer wall, inner wall and Rosenthal's canal. Ann. Otol. Rhinol. Laryngol. 105:701–709, 1996.PubMed
Zurück zum Zitat Kawano A, Seldon HL, Clark GM, Ramsden RT, Raine CH. Intracochlear factors contributing to psychophysical percepts following cochlear implantation. Acta Otolaryngol. (Stockh.). 118:313–326, 1998.CrossRef Kawano A, Seldon HL, Clark GM, Ramsden RT, Raine CH. Intracochlear factors contributing to psychophysical percepts following cochlear implantation. Acta Otolaryngol. (Stockh.). 118:313–326, 1998.CrossRef
Zurück zum Zitat Kessler DK. The Clarion® Multi-Strategy™ cochlear implant. Ann. Otol. Rhinol. Laryngol. 108:8–16, 1999. Kessler DK. The Clarion® Multi-Strategy™ cochlear implant. Ann. Otol. Rhinol. Laryngol. 108:8–16, 1999.
Zurück zum Zitat Kós M-I, Boëx C, Sigrist A, Guyot J-P, Pelizzone M. Measurements of electrode position inside the cochlea across different cochlear implant systems. Acta Oto-Laryngol. (Stockh.) 125:474–480, 2005. Kós M-I, Boëx C, Sigrist A, Guyot J-P, Pelizzone M. Measurements of electrode position inside the cochlea across different cochlear implant systems. Acta Oto-Laryngol. (Stockh.) 125:474–480, 2005.
Zurück zum Zitat Liberman CM, Dodds LW, Learson DA. Structure–function correlation in noise-damaged ears: a light and electron-microscopic study. In: Salvi RJ, Henderson D, Hamernick RP, Colletti V (eds) Basic and Applied Aspects of Noise-induced Hearing Loss. Plenum Press, New York, 1986. Liberman CM, Dodds LW, Learson DA. Structure–function correlation in noise-damaged ears: a light and electron-microscopic study. In: Salvi RJ, Henderson D, Hamernick RP, Colletti V (eds) Basic and Applied Aspects of Noise-induced Hearing Loss. Plenum Press, New York, 1986.
Zurück zum Zitat Linthicum FH Jr, Fayad J, Otto SR, Galey FR, House WF. Cochlear implant histopathology. Am. J. Otol. 12(4):245–311, 1991.PubMed Linthicum FH Jr, Fayad J, Otto SR, Galey FR, House WF. Cochlear implant histopathology. Am. J. Otol. 12(4):245–311, 1991.PubMed
Zurück zum Zitat Marsh MA, Coker NJ, Jenkins HA. Temporal bone histopathology of a patient with a Nucleus 22-channel cochlear implant. Am. J. Otol. 13(3):241–248, 1992.PubMed Marsh MA, Coker NJ, Jenkins HA. Temporal bone histopathology of a patient with a Nucleus 22-channel cochlear implant. Am. J. Otol. 13(3):241–248, 1992.PubMed
Zurück zum Zitat Marsh MA, Xu J, Blamey PJ, Whitford LA, Xu SA, Silverman JM, Clark GM. Radiologic evaluation of multichannel intracochlear implant insertion depth. Am. J. Otol. 14(4):386–391, 1993.PubMed Marsh MA, Xu J, Blamey PJ, Whitford LA, Xu SA, Silverman JM, Clark GM. Radiologic evaluation of multichannel intracochlear implant insertion depth. Am. J. Otol. 14(4):386–391, 1993.PubMed
Zurück zum Zitat McKay CM, McDermott HJ, Clark GM. The perceptual dimensions of single-electrode and nonsimultaneous dual-electrode stimuli in cochlear implantees. J. Acoust. Soc. Am. 99:1079–1090, 1996.CrossRefPubMed McKay CM, McDermott HJ, Clark GM. The perceptual dimensions of single-electrode and nonsimultaneous dual-electrode stimuli in cochlear implantees. J. Acoust. Soc. Am. 99:1079–1090, 1996.CrossRefPubMed
Zurück zum Zitat Nadol JB Jr, Ketten DR, Burgess BJ. Otopathology in a case of multichannel cochlear implantation. Laryngoscope 104:299–303, 1994.PubMedCrossRef Nadol JB Jr, Ketten DR, Burgess BJ. Otopathology in a case of multichannel cochlear implantation. Laryngoscope 104:299–303, 1994.PubMedCrossRef
Zurück zum Zitat Nadol JB Jr, Shia JY, Burgess BJ, Ketten DR, Eddington DK, Gantz BJ, Kos I, Montandon P, Coker NJ, Roland JT, Shallop JK. Histopathology of cochlear implants in the human. Ann. Otol. Rhinol. Laryngol. 110(9):883–891, 2001.PubMed Nadol JB Jr, Shia JY, Burgess BJ, Ketten DR, Eddington DK, Gantz BJ, Kos I, Montandon P, Coker NJ, Roland JT, Shallop JK. Histopathology of cochlear implants in the human. Ann. Otol. Rhinol. Laryngol. 110(9):883–891, 2001.PubMed
Zurück zum Zitat Nelson DA, Van Tasell DJ, Schroder AC, Soli S, Levine S. Electrode ranking of “place pitch” and speech recognition in electrical hearing. J. Acoust. Soc. Am. 98(4):1987–1999, 1995.CrossRefPubMed Nelson DA, Van Tasell DJ, Schroder AC, Soli S, Levine S. Electrode ranking of “place pitch” and speech recognition in electrical hearing. J. Acoust. Soc. Am. 98(4):1987–1999, 1995.CrossRefPubMed
Zurück zum Zitat O'Leary MJ, House WF, Fayad J, Linthicium FH Jr. Electrode insertion trauma in cochlear implantation. Ann. Otol. Rhinol. Laryngol. 100:695–699, 1991.PubMed O'Leary MJ, House WF, Fayad J, Linthicium FH Jr. Electrode insertion trauma in cochlear implantation. Ann. Otol. Rhinol. Laryngol. 100:695–699, 1991.PubMed
Zurück zum Zitat Pelizzone M, Boëx C, Montandon P. Vowel and consonant identification tests can be used to compare performances in a multilingual group of cochlear implant patients. ORL 55:341–346, 1993.PubMed Pelizzone M, Boëx C, Montandon P. Vowel and consonant identification tests can be used to compare performances in a multilingual group of cochlear implant patients. ORL 55:341–346, 1993.PubMed
Zurück zum Zitat Sellick PM, Patuzzi R, Johnston BM. Measurement of basilar membrane motion in the guinea pig using the Mossbauer technique. J. Acoust. Soc. Am. 33:1381–1385, 1982. Sellick PM, Patuzzi R, Johnston BM. Measurement of basilar membrane motion in the guinea pig using the Mossbauer technique. J. Acoust. Soc. Am. 33:1381–1385, 1982.
Zurück zum Zitat Shannon RV. Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics. Hear. Res. 11:157–189, 1983.CrossRefPubMed Shannon RV. Multichannel electrical stimulation of the auditory nerve in man. I. Basic psychophysics. Hear. Res. 11:157–189, 1983.CrossRefPubMed
Zurück zum Zitat Shannon RV. Psychophysics. In: Tyler RS (eds) Cochlear Implants: Audiological Foundations. Singular Publishing Inc., San Diego, 1993. Shannon RV. Psychophysics. In: Tyler RS (eds) Cochlear Implants: Audiological Foundations. Singular Publishing Inc., San Diego, 1993.
Zurück zum Zitat Simmons FB, Mathews RW, Walker MG, White RL. A functional multichannel auditory nerve stimulator. Acta Otolaryngol. 87:170–175, 1979.PubMedCrossRef Simmons FB, Mathews RW, Walker MG, White RL. A functional multichannel auditory nerve stimulator. Acta Otolaryngol. 87:170–175, 1979.PubMedCrossRef
Zurück zum Zitat Sridhar D, Stakhovskaya O, Leake PA. A frequency–position function for the human spiral ganglion. Assoc. Res. Otolaryngol. Abs. 28(909):318, 2005. Sridhar D, Stakhovskaya O, Leake PA. A frequency–position function for the human spiral ganglion. Assoc. Res. Otolaryngol. Abs. 28(909):318, 2005.
Zurück zum Zitat Terr LI, Sfogliano GA, Riley SL Jr. Effects of stimulation by cochlear implant of the cochlear nerve. Laryngoscope 99:1171–1174, 1989.PubMedCrossRef Terr LI, Sfogliano GA, Riley SL Jr. Effects of stimulation by cochlear implant of the cochlear nerve. Laryngoscope 99:1171–1174, 1989.PubMedCrossRef
Zurück zum Zitat Tong YC, Blamey PJ, Dowell RC, Clark M. Psychophysical studies evaluating the feasibility of a speech processing strategy for amultiple-channel implant. J. Acoust. Soc. Am. 74:73–80, 1983.CrossRefPubMed Tong YC, Blamey PJ, Dowell RC, Clark M. Psychophysical studies evaluating the feasibility of a speech processing strategy for amultiple-channel implant. J. Acoust. Soc. Am. 74:73–80, 1983.CrossRefPubMed
Zurück zum Zitat Tong YC, Clark M. Absolute identification of electric pulse rates and electrode positions by cochlear implant patients. J. Acoust. Soc. Am. 77(5):1881–1888, 1985.CrossRefPubMed Tong YC, Clark M. Absolute identification of electric pulse rates and electrode positions by cochlear implant patients. J. Acoust. Soc. Am. 77(5):1881–1888, 1985.CrossRefPubMed
Zurück zum Zitat Townshend B, Cotter N, Van Compernolle D, White RL. Pitch perception by cochlear implant subjects. J. Acoust. Soc. Am. 82:106–115, 1987.CrossRefPubMed Townshend B, Cotter N, Van Compernolle D, White RL. Pitch perception by cochlear implant subjects. J. Acoust. Soc. Am. 82:106–115, 1987.CrossRefPubMed
Zurück zum Zitat Verbist BM, Frijns JHM, Geleijns J, van Buchem MA. Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients. AJNR Am. J. Neuroradiol. 26(2):424–429, 2005.PubMed Verbist BM, Frijns JHM, Geleijns J, van Buchem MA. Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients. AJNR Am. J. Neuroradiol. 26(2):424–429, 2005.PubMed
Zurück zum Zitat von Békésy G. Experiments in Hearing. McGraw-Hill, New York, 1960. von Békésy G. Experiments in Hearing. McGraw-Hill, New York, 1960.
Zurück zum Zitat Xu J, Xu SA, Cohen LT, Clark GM. Cochlear view: postoperative radiography for cochlear implantation. Am. J. Otol. 21:49–56, 2000.PubMed Xu J, Xu SA, Cohen LT, Clark GM. Cochlear view: postoperative radiography for cochlear implantation. Am. J. Otol. 21:49–56, 2000.PubMed
Zurück zum Zitat Zappia JJ, Niparko JK, Kemink JL, Oviatt DL, Altschuler RA. Evaluation of the temporal bones of a multichannel cochlear implant patient. Ann. Otol. Rhinol. Laryngol. 100:914–921, 1991.PubMed Zappia JJ, Niparko JK, Kemink JL, Oviatt DL, Altschuler RA. Evaluation of the temporal bones of a multichannel cochlear implant patient. Ann. Otol. Rhinol. Laryngol. 100:914–921, 1991.PubMed
Zurück zum Zitat Zwislokci JJ, Nguyen M. Place code for pitch: a necessary revision. Acta Otolaryngol. 19:140–145, 1999. Zwislokci JJ, Nguyen M. Place code for pitch: a necessary revision. Acta Otolaryngol. 19:140–145, 1999.
Metadaten
Titel
Acoustic to Electric Pitch Comparisons in Cochlear Implant Subjects with Residual Hearing
verfasst von
Colette Boëx
Lionel Baud
Grégoire Cosendai
Alain Sigrist
Maria-Izabel Kós
Marco Pelizzone
Publikationsdatum
01.06.2006
Verlag
Springer-Verlag
Erschienen in
Journal of the Association for Research in Otolaryngology / Ausgabe 2/2006
Print ISSN: 1525-3961
Elektronische ISSN: 1438-7573
DOI
https://doi.org/10.1007/s10162-005-0027-2

Weitere Artikel der Ausgabe 2/2006

Journal of the Association for Research in Otolaryngology 2/2006 Zur Ausgabe

Update HNO

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.