Skip to main content
Erschienen in: Odontology 4/2018

30.01.2018 | Original Article

Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals

verfasst von: Taha Özyürek, Mustafa Gündoğar, Gülşah Uslu, Koray Yılmaz, Simone Staffoli, Grande NM, Gianluca Plotino, Antonella Polimeni

Erschienen in: Odontology | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

The aim of the present study was to compare the cyclic fatigue resistances of HyFlex EDM (HEDM), WaveOne Gold (WOG), Reciproc Blue (RB), and 2Shape (TS) NiTi systems having different metallurgic properties. HEDM, WOG, RB, and TS instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, 45°, and 90° angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture (TTF) was recorded in seconds. Also, number of cycles to fracture was calculated (NCF). Data were statistically analyzed using Kruskal–Wallis and t test. The statistical significance level was set at P < 0.05. When comparing the TTF of all the instruments tested in the artificial canal with 45° curvature, RB had statistically the highest cyclic fatigue resistance followed by HEDM and TS (P < 0.05), while the WOG showed the lowest cyclic fatigue resistance (P < 0.05). In artificial canal with 90° curvature, RB showed a significantly higher cyclic fatigue resistance than the other tested files (P < 0.05), while there was no significant difference among the TS, WOG and HEDM groups (P > 0.05). When the NCF values were taken into consideration, HEDM reported a significantly higher cyclic fatigue resistance than TS in both canal curvatures analyzed (P < 0.05). Within the limitations of the present study, RB NiTi files showed statistically higher cyclic fatigue resistance in artificial canals with 45° and 90° than the other NiTi files tested.
Literatur
1.
Zurück zum Zitat Walia H, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod. 1988;14:346–51.CrossRef Walia H, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod. 1988;14:346–51.CrossRef
2.
Zurück zum Zitat Paqué F, Ganahl D, Peters OA. Effects of root canal preparation on apical geometry assessed by micro–computed tomography. J Endod. 2009;35:1056–9.CrossRef Paqué F, Ganahl D, Peters OA. Effects of root canal preparation on apical geometry assessed by micro–computed tomography. J Endod. 2009;35:1056–9.CrossRef
3.
Zurück zum Zitat Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod. 2009;35:1469–76.CrossRef Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endod. 2009;35:1469–76.CrossRef
4.
Zurück zum Zitat Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod. 2000;26:161–5.CrossRef Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod. 2000;26:161–5.CrossRef
5.
Zurück zum Zitat Testarelli L, Plotino G, Al-Sudani D, Vincenzi V, Giansiracusa A, Grande NM, et al. Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel. J Endod. 2011;37:1293–5.CrossRef Testarelli L, Plotino G, Al-Sudani D, Vincenzi V, Giansiracusa A, Grande NM, et al. Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel. J Endod. 2011;37:1293–5.CrossRef
6.
Zurück zum Zitat Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G. Blue treatment enhances cyclic fatigue resistance of vortex nickel-titanium rotary files. J Endod. 2014;40:1451–3.CrossRef Plotino G, Grande NM, Cotti E, Testarelli L, Gambarini G. Blue treatment enhances cyclic fatigue resistance of vortex nickel-titanium rotary files. J Endod. 2014;40:1451–3.CrossRef
7.
Zurück zum Zitat Peters O, Gluskin A, Weiss R, Han J. An in vitro assessment of the physical properties of novel Hyflex nickel–titanium rotary instruments. Int Endod J. 2012;45:1027–34.CrossRef Peters O, Gluskin A, Weiss R, Han J. An in vitro assessment of the physical properties of novel Hyflex nickel–titanium rotary instruments. Int Endod J. 2012;45:1027–34.CrossRef
8.
Zurück zum Zitat Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne gold nickel-titanium instruments. J Endod. 2016;42:1536–9.CrossRef Özyürek T. Cyclic fatigue resistance of Reciproc, WaveOne, and WaveOne gold nickel-titanium instruments. J Endod. 2016;42:1536–9.CrossRef
9.
Zurück zum Zitat Plotino G, Grande NM, Bellido MM, Testarelli L, Gambarini G. Influence of temperature on cyclic fatigue resistance of ProTaper gold and ProTaper Universal rotary files. J Endod. 2017;43:200–2.CrossRef Plotino G, Grande NM, Bellido MM, Testarelli L, Gambarini G. Influence of temperature on cyclic fatigue resistance of ProTaper gold and ProTaper Universal rotary files. J Endod. 2017;43:200–2.CrossRef
10.
Zurück zum Zitat De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files. J Endod. 2017;43:462–6.CrossRef De-Deus G, Silva EJNL, Vieira VTL, Belladonna FG, Elias CN, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files. J Endod. 2017;43:462–6.CrossRef
11.
Zurück zum Zitat Haapasalo M, Shen Y. Evolution of nickel–titanium instruments: from past to future. Endod Top. 2013;29:3–17.CrossRef Haapasalo M, Shen Y. Evolution of nickel–titanium instruments: from past to future. Endod Top. 2013;29:3–17.CrossRef
12.
Zurück zum Zitat Pedullà E, Savio FL, Boninelli S, Plotino G, Grande NM, La Rosa G, et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42:156–9.CrossRef Pedullà E, Savio FL, Boninelli S, Plotino G, Grande NM, La Rosa G, et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016;42:156–9.CrossRef
13.
Zurück zum Zitat Gündoğar M, Özyürek T. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne gold, and Reciproc blue nickel-titanium instruments. J Endod. 2017;43:1192–6.CrossRef Gündoğar M, Özyürek T. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne gold, and Reciproc blue nickel-titanium instruments. J Endod. 2017;43:1192–6.CrossRef
14.
Zurück zum Zitat Saleh AM, Gilani PV, Tavanafar S, Schäfer E. Shaping ability of 4 different single-file systems in simulated S-shaped canals. J Endod. 2015;41:548–52.CrossRef Saleh AM, Gilani PV, Tavanafar S, Schäfer E. Shaping ability of 4 different single-file systems in simulated S-shaped canals. J Endod. 2015;41:548–52.CrossRef
15.
Zurück zum Zitat Topçuoğlu H, Topçuoğlu G, Aktı A. Comparative evaluation of cyclic fatigue resistance of D-RaCe and ProTaper retreatment instruments in curved artificial canals. Int Endod J. 2016;49:604–9.CrossRef Topçuoğlu H, Topçuoğlu G, Aktı A. Comparative evaluation of cyclic fatigue resistance of D-RaCe and ProTaper retreatment instruments in curved artificial canals. Int Endod J. 2016;49:604–9.CrossRef
16.
Zurück zum Zitat Plotino G, Costanzo A, Grande NM, Petrovic R, Testarelli L, Gambarini G. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. J Endod. 2012;38:222–5.CrossRef Plotino G, Costanzo A, Grande NM, Petrovic R, Testarelli L, Gambarini G. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. J Endod. 2012;38:222–5.CrossRef
17.
Zurück zum Zitat Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod. 2013;39:258–61.CrossRef Pedullà E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod. 2013;39:258–61.CrossRef
18.
Zurück zum Zitat Plotino G, Ahmed HMA, Grande NM, Cohen S, Bukiet F. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part II: properties and effectiveness. J Endod. 2015;41:1939–50.CrossRef Plotino G, Ahmed HMA, Grande NM, Cohen S, Bukiet F. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part II: properties and effectiveness. J Endod. 2015;41:1939–50.CrossRef
19.
Zurück zum Zitat Grande NM, Ahmed HMA, Cohen S, Bukiet F, Plotino G. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part I: historical perspectives and current applications. J Endod. 2015;41:1778–83.CrossRef Grande NM, Ahmed HMA, Cohen S, Bukiet F, Plotino G. Current assessment of reciprocation in endodontic preparation: a comprehensive review—part I: historical perspectives and current applications. J Endod. 2015;41:1778–83.CrossRef
20.
Zurück zum Zitat Grande NM, Plotino G, Ahmed HMA, Cohen S, Bukiet F. The reciprocating movement in endodontics. Endod Prac. 2016;9:37–42. Grande NM, Plotino G, Ahmed HMA, Cohen S, Bukiet F. The reciprocating movement in endodontics. Endod Prac. 2016;9:37–42.
21.
Zurück zum Zitat Elnaghy A, Elsaka S. Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne gold and Reciproc reciprocating instruments. Int Endod J. 2017;50:991–8.CrossRef Elnaghy A, Elsaka S. Effect of sodium hypochlorite and saline on cyclic fatigue resistance of WaveOne gold and Reciproc reciprocating instruments. Int Endod J. 2017;50:991–8.CrossRef
22.
Zurück zum Zitat Topçuoğlu H, Düzgün S, Aktı A, Topçuoğlu G. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. Int Endod J. 2017;50:713–7.CrossRef Topçuoğlu H, Düzgün S, Aktı A, Topçuoğlu G. Laboratory comparison of cyclic fatigue resistance of WaveOne Gold, Reciproc and WaveOne files in canals with a double curvature. Int Endod J. 2017;50:713–7.CrossRef
23.
Zurück zum Zitat Cheung G, Zhang E, Zheng Y. A numerical method for predicting the bending fatigue life of NiTi and stainless steel root canal instruments. Int Endod J. 2011;44:357–61.CrossRef Cheung G, Zhang E, Zheng Y. A numerical method for predicting the bending fatigue life of NiTi and stainless steel root canal instruments. Int Endod J. 2011;44:357–61.CrossRef
24.
Zurück zum Zitat Grande NM, Plotino G, Pecci R, Bedini R, Somma F. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. Int Endod J. 2006;39:755–63.CrossRef Grande NM, Plotino G, Pecci R, Bedini R, Somma F. Cyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems. Int Endod J. 2006;39:755–63.CrossRef
25.
Zurück zum Zitat Plotino G, Grande NM, Melo MC, Bahia MG, Testarelli L, Gambarini G. Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature. Int Endod J. 2010;43:226–30.CrossRef Plotino G, Grande NM, Melo MC, Bahia MG, Testarelli L, Gambarini G. Cyclic fatigue of NiTi rotary instruments in a simulated apical abrupt curvature. Int Endod J. 2010;43:226–30.CrossRef
26.
Zurück zum Zitat Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. Int Endod J. 2012;45:614–8.CrossRef Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. Int Endod J. 2012;45:614–8.CrossRef
27.
Zurück zum Zitat Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997;23:77–85.CrossRef Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod. 1997;23:77–85.CrossRef
Metadaten
Titel
Cyclic fatigue resistances of Hyflex EDM, WaveOne gold, Reciproc blue and 2shape NiTi rotary files in different artificial canals
verfasst von
Taha Özyürek
Mustafa Gündoğar
Gülşah Uslu
Koray Yılmaz
Simone Staffoli
Grande NM
Gianluca Plotino
Antonella Polimeni
Publikationsdatum
30.01.2018
Verlag
Springer Japan
Erschienen in
Odontology / Ausgabe 4/2018
Print ISSN: 1618-1247
Elektronische ISSN: 1618-1255
DOI
https://doi.org/10.1007/s10266-018-0340-y

Weitere Artikel der Ausgabe 4/2018

Odontology 4/2018 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.