The conventional method of bone mineral density (BMD) report production by dictation and transcription is time consuming and prone to error. We developed an automated BMD reporting system based on the raw data from a dual energy X-ray absorptiometry (DXA) scanner for facilitating the report generation. The automated BMD reporting system, a web application, digests the DXA’s raw data and automatically generates preliminary reports. In Jan. 2014, 500 examinations were randomized into an automatic group (AG) and a manual group (MG), and the speed of report generation was compared. For evaluation of the accuracy and analysis of errors, 5120 examinations during Jan. 2013 and Dec. 2013 were enrolled retrospectively, and the context of automatically generated reports (AR) was compared with the formal manual reports (MR). The average time spent for report generation in AG and in MG was 264 and 1452 s, respectively (p < 0.001). The accuracy of calculation of T and Z scores in AR is 100 %. The overall accuracy of AR and MR is 98.8 and 93.7 %, respectively (p < 0.001). The mis-categorization rate in AR and MR is 0.039 and 0.273 %, respectively (p = 0.0013). Errors occurred in AR and can be grouped into key-in errors by technicians and need for additional judgements. We constructed an efficient and reliable automated BMD reporting system. It facilitates current clinical service and potentially prevents human errors from technicians, transcriptionists, and radiologists.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Consensus development conference: diagnosis, prophylaxis, and treatment of osteoporosis. Am J Med 94:646–650, 1993 Consensus development conference: diagnosis, prophylaxis, and treatment of osteoporosis. Am J Med 94:646–650, 1993
2.
Zurück zum Zitat Schousboe JT, Shepherd JA, Bilezikian JP, Baim S: Executive summary of the 2013 international society for clinical densitometry position development conference on bone densitometry. J Clin Densitom Off J Int Soc Clin Densitom 16:455–466, 2013CrossRef Schousboe JT, Shepherd JA, Bilezikian JP, Baim S: Executive summary of the 2013 international society for clinical densitometry position development conference on bone densitometry. J Clin Densitom Off J Int Soc Clin Densitom 16:455–466, 2013CrossRef
6.
Zurück zum Zitat Iv M, Patel MR, Santos A, Kang YS: Informatics in radiology: use of a macro scripting editor to facilitate transfer of dual-energy X-ray absorptiometry reports into an existing departmental voice recognition dictation system. Radiographics Rev Publ Radiol Soc N Am Inc 31:1181–1189, 2011 Iv M, Patel MR, Santos A, Kang YS: Informatics in radiology: use of a macro scripting editor to facilitate transfer of dual-energy X-ray absorptiometry reports into an existing departmental voice recognition dictation system. Radiographics Rev Publ Radiol Soc N Am Inc 31:1181–1189, 2011
7.
Zurück zum Zitat Lee YH, Song H-T, Suh J-S: Quantitative computed tomography (QCT) as a radiology reporting tool by using optical character recognition (OCR) and macro program. J Digit Imaging 25:815–818, 2012CrossRefPubMedPubMedCentral Lee YH, Song H-T, Suh J-S: Quantitative computed tomography (QCT) as a radiology reporting tool by using optical character recognition (OCR) and macro program. J Digit Imaging 25:815–818, 2012CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Goddard P, Leslie A, Jones A, Wakeley C, Kabala J: Error in radiology. Br J Radiol 74:949–951, 2001CrossRefPubMed Goddard P, Leslie A, Jones A, Wakeley C, Kabala J: Error in radiology. Br J Radiol 74:949–951, 2001CrossRefPubMed
9.
Zurück zum Zitat McGurk S, Brauer K, Macfarlane TV, Duncan KA: The effect of voice recognition software on comparative error rates in radiology reports. Br J Radiol 81:767–770, 2008CrossRefPubMed McGurk S, Brauer K, Macfarlane TV, Duncan KA: The effect of voice recognition software on comparative error rates in radiology reports. Br J Radiol 81:767–770, 2008CrossRefPubMed
Metadaten
Titel
Development of an Automated Bone Mineral Density Software Application: Facilitation Radiologic Reporting and Improvement of Accuracy
verfasst von
I-Ta Tsai
Meng-Yuan Tsai
Ming-Ting Wu
Clement Kuen-Huang Chen
Publikationsdatum
07.12.2015
Verlag
Springer International Publishing
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 3/2016
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-015-9848-7

Weitere Artikel der Ausgabe 3/2016

Journal of Digital Imaging 3/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.