A comparative brief on conducted electrical weapon safety

verfasst von: PD. Dr. Sebastian N. Kunz, PD. Dr. Jiri Adamec

Erschienen in: Wiener Medizinische Wochenschrift | Ausgabe 7-8/2019

Einloggen, um Zugang zu erhalten

Summary

The variety and high number of published research articles on conducted electrical weapons (CEW) provides a detailed, yet in some parts inconclusive overview of medical aspects of CEW. Due to different research approaches and the use of dissimilar test subjects, an assessment of possible health risks of CEW is limited. The present work provides a brief on CEW safety based on currently available animal, computer and human research data. Using the medical database PubMed, articles published on this topic are critically evaluated and compared with each other. Special focuses are the differences and similarities of human and animal research as well as computer simulation programs. The authors explain why some studies are more reliable than others and give their expert opinion on the safety of CEW. The body of data that have been reviewed provides reasonable support for the safety of CEW.
Literatur
1.
Zurück zum Zitat Pasquier M, Carron PN, Vallotton L, Yersin B. Electronic control device exposure: a review of morbidity and mortality. Ann Emerg Med. 2011;58:177–88. Pasquier M, Carron PN, Vallotton L, Yersin B. Electronic control device exposure: a review of morbidity and mortality. Ann Emerg Med. 2011;58:177–88.
2.
Zurück zum Zitat Ho J, Dawes D, Miner J, Kunz SN, Nelson R, Williamson C, Sweeney J. Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread. Forensic Sci Med Pathol. 2012;8:358–66.PubMed Ho J, Dawes D, Miner J, Kunz SN, Nelson R, Williamson C, Sweeney J. Conducted electrical weapon incapacitation during a goal-directed task as a function of probe spread. Forensic Sci Med Pathol. 2012;8:358–66.PubMed
3.
Zurück zum Zitat Kroll MW. Physiology and pathology of TASER electronic control devices. J Forensic Leg Med. 2009;16:173–7.PubMed Kroll MW. Physiology and pathology of TASER electronic control devices. J Forensic Leg Med. 2009;16:173–7.PubMed
4.
Zurück zum Zitat Stopyra JP, Ritter SI, Beatty J, Johnson JC, Kleiner DM, Winslow JE 3rd, Gardner AR, Bozeman WP. A TASER conducted electrical weapon with cardiac biomonitoring capability: proof of concept and initial human trial. J Forensic Leg Med. 2016;43:48–52.PubMed Stopyra JP, Ritter SI, Beatty J, Johnson JC, Kleiner DM, Winslow JE 3rd, Gardner AR, Bozeman WP. A TASER conducted electrical weapon with cardiac biomonitoring capability: proof of concept and initial human trial. J Forensic Leg Med. 2016;43:48–52.PubMed
5.
Zurück zum Zitat Clarke C, Andrews SP. The ignitability of petrol vapours and potential for vapour phase explosion by use of TASER law enforcement electronic control device. Sci Justice. 2014;54:412–20.PubMed Clarke C, Andrews SP. The ignitability of petrol vapours and potential for vapour phase explosion by use of TASER law enforcement electronic control device. Sci Justice. 2014;54:412–20.PubMed
6.
Zurück zum Zitat Kunz SN, Adamec J, Zinka B, Münzel D, Noel PB, Eichner S, Manthei A, Grove N, Graw M, Peschel O. Wound ballistic evaluation of the TASER XREP ammunition. Int J Legal Med. 2013;127:119–26.PubMed Kunz SN, Adamec J, Zinka B, Münzel D, Noel PB, Eichner S, Manthei A, Grove N, Graw M, Peschel O. Wound ballistic evaluation of the TASER XREP ammunition. Int J Legal Med. 2013;127:119–26.PubMed
7.
Zurück zum Zitat Koscove EM. The taser weapon: a new emergency medicine problem. Ann Emerg Med. 1985;14:1205–8.PubMed Koscove EM. The taser weapon: a new emergency medicine problem. Ann Emerg Med. 1985;14:1205–8.PubMed
8.
Zurück zum Zitat Stopyra JP, Winslow JE, Fitzgerald DM, Bozeman WP. Intracardiac electrocardiographic assessment of precordial TASER shocks in human subjects: a pilot study. J Forensic Leg Med. 2017;52:70–4.PubMed Stopyra JP, Winslow JE, Fitzgerald DM, Bozeman WP. Intracardiac electrocardiographic assessment of precordial TASER shocks in human subjects: a pilot study. J Forensic Leg Med. 2017;52:70–4.PubMed
9.
Zurück zum Zitat Madea M. Leserbrief zum Beitrag Elektrowaffe ADVANCED TASER M26. Rechtsmedizin. 2003;13:114. Madea M. Leserbrief zum Beitrag Elektrowaffe ADVANCED TASER M26. Rechtsmedizin. 2003;13:114.
10.
Zurück zum Zitat Bux R, Andresen D, Rothschild MA. Elektrowaffe ADVANCED TASER M 26. Funktionsweise, Wirksamkeit und Kasuistik. Rechtsmedizin. 2002;12:207–13. Bux R, Andresen D, Rothschild MA. Elektrowaffe ADVANCED TASER M 26. Funktionsweise, Wirksamkeit und Kasuistik. Rechtsmedizin. 2002;12:207–13.
11.
Zurück zum Zitat Kunz SN, Monticelli F, Kaiser C. Death by conducted electrical weapons. Diagnosis by exclusion? Rechtsmedizin. 2012;22:369–73. Kunz SN, Monticelli F, Kaiser C. Death by conducted electrical weapons. Diagnosis by exclusion? Rechtsmedizin. 2012;22:369–73.
12.
Zurück zum Zitat Fieseler S, Zinka B, Peschel O, Kunz SN. Elektrowaffe Taser® – Funktion, Wirkung, kritische Aspekte. Rechtsmedizin. 2011;21:535–40. Fieseler S, Zinka B, Peschel O, Kunz SN. Elektrowaffe Taser® – Funktion, Wirkung, kritische Aspekte. Rechtsmedizin. 2011;21:535–40.
13.
Zurück zum Zitat Kunz SN, Adamec J. Cardiac aspects of conducted electrical weapons (CEW). Rechtsmedizin. 2017;27:79–86. Kunz SN, Adamec J. Cardiac aspects of conducted electrical weapons (CEW). Rechtsmedizin. 2017;27:79–86.
14.
Zurück zum Zitat Kunz SN, Grove C. Risikoeinschätzung von Elektroschockdistanzwaffen – eine Übersichtsarbeit aus gerichtsärztlicher Sicht. SIAK J. 2015;1:94–101. Kunz SN, Grove C. Risikoeinschätzung von Elektroschockdistanzwaffen – eine Übersichtsarbeit aus gerichtsärztlicher Sicht. SIAK J. 2015;1:94–101.
15.
Zurück zum Zitat Kunz SN, Grove C, Monticelli F. Medizinische Aspekte gängiger nicht-letaler Wirkmittel. Wien Med Wochenschr. 2014;164:103–8.PubMed Kunz SN, Grove C, Monticelli F. Medizinische Aspekte gängiger nicht-letaler Wirkmittel. Wien Med Wochenschr. 2014;164:103–8.PubMed
16.
Zurück zum Zitat Kunz SN. Blut, Schweiβ und Tränengas. Ärzte Woche. 2016;36:4–6. Kunz SN. Blut, Schweiβ und Tränengas. Ärzte Woche. 2016;36:4–6.
17.
Zurück zum Zitat Criscione JC, Kroll MW. Incapacitation recovery times from a conductive electrical weapon exposure. Forensic Sci Med Pathol. 2014;10:203–7.PubMed Criscione JC, Kroll MW. Incapacitation recovery times from a conductive electrical weapon exposure. Forensic Sci Med Pathol. 2014;10:203–7.PubMed
18.
Zurück zum Zitat Dawes DM, Ho J, Miner J. The neuroendocrine effects of the TASER X26: a brief report. Forensic Sci Int. 2009;183:14–9.PubMed Dawes DM, Ho J, Miner J. The neuroendocrine effects of the TASER X26: a brief report. Forensic Sci Int. 2009;183:14–9.PubMed
19.
Zurück zum Zitat Dawes DM, Ho JD. Re: Myocardial infarction after TASER exposure. J LA Sate Med Soc 2010; 162: 291–295. J La State Med Soc. 2011;163:64. author reply 66.PubMed Dawes DM, Ho JD. Re: Myocardial infarction after TASER exposure. J LA Sate Med Soc 2010; 162: 291–295. J La State Med Soc. 2011;163:64. author reply 66.PubMed
20.
Zurück zum Zitat Dawes DM, Ho JD, Reardon RF, Miner JR. Echocardiographic evaluation of TASER X26 probe deployment into the chest of human volunteers. Am J Emerg Med. 2010;28:49–55.PubMed Dawes DM, Ho JD, Reardon RF, Miner JR. Echocardiographic evaluation of TASER X26 probe deployment into the chest of human volunteers. Am J Emerg Med. 2010;28:49–55.PubMed
21.
Zurück zum Zitat Dawes DM, Ho JD, Reardon RF, Miner JR. The cardiovascular, respiratory, and metabolic effects of a long duration electronic control device exposure in human volunteers. Forensic Sci Med Pathol. 2010;6:268–74.PubMed Dawes DM, Ho JD, Reardon RF, Miner JR. The cardiovascular, respiratory, and metabolic effects of a long duration electronic control device exposure in human volunteers. Forensic Sci Med Pathol. 2010;6:268–74.PubMed
22.
Zurück zum Zitat Dawes DM, Ho JD, Reardon RF, Strote SR, Nelson RS, Lundin EJ, Orozco BS, Kunz SN, Miner JR. The respiratory, metabolic, and neuroendocrine effects of a new generation electronic control device. Forensic Sci Int. 2011;207:55–60.PubMed Dawes DM, Ho JD, Reardon RF, Strote SR, Nelson RS, Lundin EJ, Orozco BS, Kunz SN, Miner JR. The respiratory, metabolic, and neuroendocrine effects of a new generation electronic control device. Forensic Sci Int. 2011;207:55–60.PubMed
23.
Zurück zum Zitat Dawes DM, Ho JD, Readon RF, Sweeney JD, Miner JR. The physiologic effects of multiple simultaneous electronic control device discharges. West J Emerg Med. 2010;11:49–56.PubMedPubMedCentral Dawes DM, Ho JD, Readon RF, Sweeney JD, Miner JR. The physiologic effects of multiple simultaneous electronic control device discharges. West J Emerg Med. 2010;11:49–56.PubMedPubMedCentral
24.
Zurück zum Zitat Dawes DM, Ho JD, Sweeney JD, Lundin EJ, Kunz SN, Miner JR. The effect of an electronic control device on muscle injury as determined by creatine kinase enzyme. Forensic Sci Med Pathol. 2011;7:3–8.PubMed Dawes DM, Ho JD, Sweeney JD, Lundin EJ, Kunz SN, Miner JR. The effect of an electronic control device on muscle injury as determined by creatine kinase enzyme. Forensic Sci Med Pathol. 2011;7:3–8.PubMed
25.
Zurück zum Zitat Dawes DM, Ho JD, Vincent AS, Nystrom PC, Moore JC, Steinberg LW, Tilton AM, Brave MA, Berris MS, Miner JR. The neurocognitive effects of simulated use-of-force scenarios. Forensic Sci Med Pathol. 2014;10:9–17.PubMed Dawes DM, Ho JD, Vincent AS, Nystrom PC, Moore JC, Steinberg LW, Tilton AM, Brave MA, Berris MS, Miner JR. The neurocognitive effects of simulated use-of-force scenarios. Forensic Sci Med Pathol. 2014;10:9–17.PubMed
26.
Zurück zum Zitat Ho HJ, Dawes DM, Reardon RF, Lapine AL, Dolan BJ, Lundin EJ, Miner JR. Echocardiographic evaluation of a TASER-X-26 application in the ideal human cardiac axis. Acad Emerg Med. 2008;15:838–44.PubMed Ho HJ, Dawes DM, Reardon RF, Lapine AL, Dolan BJ, Lundin EJ, Miner JR. Echocardiographic evaluation of a TASER-X-26 application in the ideal human cardiac axis. Acad Emerg Med. 2008;15:838–44.PubMed
27.
Zurück zum Zitat Ho JD, Dawes DM, Chang RJ, Nelson RS, Miner JR. Physiologic effects of a new-generation conducted electrical weapon on human volunteers. J Emerg Med. 2014;46:428–35.PubMed Ho JD, Dawes DM, Chang RJ, Nelson RS, Miner JR. Physiologic effects of a new-generation conducted electrical weapon on human volunteers. J Emerg Med. 2014;46:428–35.PubMed
29.
Zurück zum Zitat Ho JD, Dawes DM, Reardon RF, Strote SR, Kunz SN, Nelson RS, Lundin EJ, Orozco BS, Miner JR. Human cardiovascular effects of a new generation conducted electrical weapon. Forensic Sci Int. 2011;204:50–7.PubMed Ho JD, Dawes DM, Reardon RF, Strote SR, Kunz SN, Nelson RS, Lundin EJ, Orozco BS, Miner JR. Human cardiovascular effects of a new generation conducted electrical weapon. Forensic Sci Int. 2011;204:50–7.PubMed
30.
Zurück zum Zitat Dawes DM, Ho J, Moore JC, Laudenbach AP, Reardon RF, Miner JR. An evaluation of two conducted electrical weapons using a swine comparative cardiac safety model. Forensic Sci Med Pathol. 2014;10:329–35.PubMed Dawes DM, Ho J, Moore JC, Laudenbach AP, Reardon RF, Miner JR. An evaluation of two conducted electrical weapons using a swine comparative cardiac safety model. Forensic Sci Med Pathol. 2014;10:329–35.PubMed
31.
Zurück zum Zitat Dawes DM, Ho JD, Moore JC, Miner JR. Erratum to: an evaluation of two conducted electrical weapons and two probe designs using a swine comparative cardiac safety model. Forensic Sci Med Pathol. 2013;9:343. Dawes DM, Ho JD, Moore JC, Miner JR. Erratum to: an evaluation of two conducted electrical weapons and two probe designs using a swine comparative cardiac safety model. Forensic Sci Med Pathol. 2013;9:343.
32.
Zurück zum Zitat Jenkins DM Jr, Murray WB, Kennett MJ, Hughes EL, Werner JR. The effect of continuous application of the TASER X26 waveform on Sus scrofa. J Forensic Sci. 2013;58:684–92.PubMed Jenkins DM Jr, Murray WB, Kennett MJ, Hughes EL, Werner JR. The effect of continuous application of the TASER X26 waveform on Sus scrofa. J Forensic Sci. 2013;58:684–92.PubMed
33.
Zurück zum Zitat Khaja A, Govindarajan G, McDaniel W, Flaker G. Cardiac safety of conducted electrical devices in pigs and their effect on pacemaker function. Am J Emerg Med. 2011;29:1089–96.PubMed Khaja A, Govindarajan G, McDaniel W, Flaker G. Cardiac safety of conducted electrical devices in pigs and their effect on pacemaker function. Am J Emerg Med. 2011;29:1089–96.PubMed
34.
Zurück zum Zitat Mc Daniel W, Stratbucker R, Smith R. Surface application of taser stun guns does not cause ventricular fibrillation in canines. Proc Annu Int Conf IEEE Eng Med Biol Soc 2000. 2000. Mc Daniel W, Stratbucker R, Smith R. Surface application of taser stun guns does not cause ventricular fibrillation in canines. Proc Annu Int Conf IEEE Eng Med Biol Soc 2000. 2000.
35.
Zurück zum Zitat Kunz SN, Aronshtam Y, Tränkler HR, Kraus S, Graw M, Peschel O. Cardiac changes due to electronic control devices? A computer-based analysis of electrical effects at the human heart caused by an ECD pulse applied to the body’s exterior. J Forensic Sci. 2014;59:659–64.PubMed Kunz SN, Aronshtam Y, Tränkler HR, Kraus S, Graw M, Peschel O. Cardiac changes due to electronic control devices? A computer-based analysis of electrical effects at the human heart caused by an ECD pulse applied to the body’s exterior. J Forensic Sci. 2014;59:659–64.PubMed
36.
Zurück zum Zitat Kroll MW, Panescu D, Carver M, Kroll RM, Hinz AF. Cardiac effects of varying pulse charge and polarity of TASER conducted electrical weapons. Conf Proc IEEE Eng Med Biol Soc 2009. 2009. pp. 3195–8. Kroll MW, Panescu D, Carver M, Kroll RM, Hinz AF. Cardiac effects of varying pulse charge and polarity of TASER conducted electrical weapons. Conf Proc IEEE Eng Med Biol Soc 2009. 2009. pp. 3195–8.
37.
Zurück zum Zitat Panescu D, Kroll M, Iverson C, Brave M. The sternum as an electrical shield. Conf Proc IEEE Eng Med Biol Soc 2014. 2014. pp. 4464–70. Panescu D, Kroll M, Iverson C, Brave M. The sternum as an electrical shield. Conf Proc IEEE Eng Med Biol Soc 2014. 2014. pp. 4464–70.
38.
Zurück zum Zitat Panescu D, Kroll M, Brave M. Cardiac fibrillation risks with TASER conducted electrical weapons. Conf Proc IEEE Eng Med Biol Soc 2015. 2015. pp. 323–9. Panescu D, Kroll M, Brave M. Cardiac fibrillation risks with TASER conducted electrical weapons. Conf Proc IEEE Eng Med Biol Soc 2015. 2015. pp. 323–9.
39.
Zurück zum Zitat Panescu D, Kroll MW, Stratbucker RA. Theoretical possibility of ventricular fibrillation during use of TASER neuromuscular incapacitation devices. Conf Proc IEEE Eng Med Biol Soc. 2008. 2008. pp. 5671–4. Panescu D, Kroll MW, Stratbucker RA. Theoretical possibility of ventricular fibrillation during use of TASER neuromuscular incapacitation devices. Conf Proc IEEE Eng Med Biol Soc. 2008. 2008. pp. 5671–4.
41.
Zurück zum Zitat Leitgeb N. Cardiac fibrillation risk of taser weapons. Health Phys. 2014;106:652–9.PubMed Leitgeb N. Cardiac fibrillation risk of taser weapons. Health Phys. 2014;106:652–9.PubMed
42.
Zurück zum Zitat Nanthakumar K, Billingsley IM, Masse S, Dorian P, Cameron D, Chauhan VS, Downar E, Sevaptsidis E. Cardiac electrophysiological consequence of neuromuscular incapacitating device discharges. J Am Coll Cardiol. 2006;48:798–804.PubMed Nanthakumar K, Billingsley IM, Masse S, Dorian P, Cameron D, Chauhan VS, Downar E, Sevaptsidis E. Cardiac electrophysiological consequence of neuromuscular incapacitating device discharges. J Am Coll Cardiol. 2006;48:798–804.PubMed
43.
Zurück zum Zitat Valentino DJ, Walter RJ, Dennis AJ, Margeta B, Starr F, Nagy KK, Bokari F, Wiley DE, Joseph KT, Roberts RR. Taser X26 discharge in swine: ventricular rhythm capture is dependent on discharge vector. J Trauma. 2008;65:1478–85.PubMed Valentino DJ, Walter RJ, Dennis AJ, Margeta B, Starr F, Nagy KK, Bokari F, Wiley DE, Joseph KT, Roberts RR. Taser X26 discharge in swine: ventricular rhythm capture is dependent on discharge vector. J Trauma. 2008;65:1478–85.PubMed
44.
Zurück zum Zitat Dennis A, Valentino D, Walter R, Nagy K, Winners J, Bokhari F, Wiley D, Joseph K, Roberts R. Acute effects of TASER X26 discharges in a swine model. J Trauma. 2007;63:581–90.PubMed Dennis A, Valentino D, Walter R, Nagy K, Winners J, Bokhari F, Wiley D, Joseph K, Roberts R. Acute effects of TASER X26 discharges in a swine model. J Trauma. 2007;63:581–90.PubMed
45.
Zurück zum Zitat Nanthakumar K, Massé S, Umapathy K, Dorian P, Sevaptsidis E, Waxman M. Cardiac stimulation with high voltage discharge from stun guns. CMAJ. 2008;178:1451–7.PubMedPubMedCentral Nanthakumar K, Massé S, Umapathy K, Dorian P, Sevaptsidis E, Waxman M. Cardiac stimulation with high voltage discharge from stun guns. CMAJ. 2008;178:1451–7.PubMedPubMedCentral
46.
Zurück zum Zitat Walter RJ, Dennis AJ, Valentino DJ, Margeta B, Nagy KK, Bokhari F, Wiley DE, Joseph KT, Roberts RR. TASER X26 discharge in swine produce potentially fatal ventricular arrhythmias. Acad Emerg Med. 2008;15:66–73.PubMed Walter RJ, Dennis AJ, Valentino DJ, Margeta B, Nagy KK, Bokhari F, Wiley DE, Joseph KT, Roberts RR. TASER X26 discharge in swine produce potentially fatal ventricular arrhythmias. Acad Emerg Med. 2008;15:66–73.PubMed
47.
Zurück zum Zitat Wu JY, Sun H, O’Rourke AP, Huebner SM, Rahko PS, Will JA, Webster JG. Taser blunt probe dart-to-heart distance causing ventricular fibrillation in pigs. IEEE Trans Biomed Eng. 2008;55:2768–71.PubMed Wu JY, Sun H, O’Rourke AP, Huebner SM, Rahko PS, Will JA, Webster JG. Taser blunt probe dart-to-heart distance causing ventricular fibrillation in pigs. IEEE Trans Biomed Eng. 2008;55:2768–71.PubMed
48.
Zurück zum Zitat VanMeenen KM, Lavietes MH, Cherniack NS, Bergen MT, Teichman R, Servatius RJ. Respiratory and cardiovascular response during electronic control device exposure in law enforcement trainees. Front Physiol. 2013;4:78.PubMedPubMedCentral VanMeenen KM, Lavietes MH, Cherniack NS, Bergen MT, Teichman R, Servatius RJ. Respiratory and cardiovascular response during electronic control device exposure in law enforcement trainees. Front Physiol. 2013;4:78.PubMedPubMedCentral
49.
Zurück zum Zitat Vilke GM, Sloane CM, Bouton KD, Kolkhorst FW, Levine SD, Neuman TS, Castillo EM, Chan TC. Physiological effects of a conducted electrical weapon on human subjects. Ann Emerg Med. 2007;50:569–75.PubMed Vilke GM, Sloane CM, Bouton KD, Kolkhorst FW, Levine SD, Neuman TS, Castillo EM, Chan TC. Physiological effects of a conducted electrical weapon on human subjects. Ann Emerg Med. 2007;50:569–75.PubMed
50.
Zurück zum Zitat Vilke GM, Sloane CM, Suffecool A, Kolkhorst FW, Neuman TS, Castillo EM, Chan TC. Physiologic effects of the TASER after exercise. Acad Emerg Med. 2009;16:704–10.PubMed Vilke GM, Sloane CM, Suffecool A, Kolkhorst FW, Neuman TS, Castillo EM, Chan TC. Physiologic effects of the TASER after exercise. Acad Emerg Med. 2009;16:704–10.PubMed
51.
Zurück zum Zitat Ho JD, Dawes DM, Bultman LL, Thacker JL, Skinner LD, Bahr JM, Johnson MA, Miner JR. Respiratory effect of prolonged electrical weapon application on human volunteers. Acad Emerg Med. 2007;14:197–201.PubMed Ho JD, Dawes DM, Bultman LL, Thacker JL, Skinner LD, Bahr JM, Johnson MA, Miner JR. Respiratory effect of prolonged electrical weapon application on human volunteers. Acad Emerg Med. 2007;14:197–201.PubMed
52.
Zurück zum Zitat Ho J, Lapine A, Joing S, Reardon R, Dawes D. Confirmation of respiration during trapezial conducted electrical weapon application. Acad Emerg Med. 2008;15:398.PubMed Ho J, Lapine A, Joing S, Reardon R, Dawes D. Confirmation of respiration during trapezial conducted electrical weapon application. Acad Emerg Med. 2008;15:398.PubMed
53.
Zurück zum Zitat Esquivel AO, Dawe EJ, Sala-Mercado JA, Hammond RL, Bir CA. The physiologic effects of a conducted electrical weapon in swine. Ann Emerg Med. 2007;50:576–83.PubMed Esquivel AO, Dawe EJ, Sala-Mercado JA, Hammond RL, Bir CA. The physiologic effects of a conducted electrical weapon in swine. Ann Emerg Med. 2007;50:576–83.PubMed
54.
Zurück zum Zitat Jauchem JR, Seaman RL, Fines DA. Survival of anesthetized Sus scrofa fter cycling (7 s on/3 s off) exposures to a TASER X26 electronic device for three minutes. Am J Forensic Med Pathol. 2011;32:124–30.PubMed Jauchem JR, Seaman RL, Fines DA. Survival of anesthetized Sus scrofa fter cycling (7 s on/3 s off) exposures to a TASER X26 electronic device for three minutes. Am J Forensic Med Pathol. 2011;32:124–30.PubMed
55.
Zurück zum Zitat Jauchem JR, Sherry CJ, Fines DA, Cook MC. Acidosis, lactate, electrolytes, muscle enzymes, and other factors in the blood of Sus scrofa following repeated TASER exposures. Forensic Sci Int. 2006;161:20–30.PubMed Jauchem JR, Sherry CJ, Fines DA, Cook MC. Acidosis, lactate, electrolytes, muscle enzymes, and other factors in the blood of Sus scrofa following repeated TASER exposures. Forensic Sci Int. 2006;161:20–30.PubMed
56.
Zurück zum Zitat Jauchem JR, Cook MC, Beason CW. Blood factors of Sus scrofa following a series of three TASER electronic control device exposures. Forensic Sci Int. 2008;175:166–70.PubMed Jauchem JR, Cook MC, Beason CW. Blood factors of Sus scrofa following a series of three TASER electronic control device exposures. Forensic Sci Int. 2008;175:166–70.PubMed
57.
Zurück zum Zitat Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegard WG. Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006;13:589–95.PubMed Ho JD, Miner JR, Lakireddy DR, Bultman LL, Heegard WG. Cardiovascular and physiologic effects of conducted electrical weapon discharge in resting adults. Acad Emerg Med. 2006;13:589–95.PubMed
58.
Zurück zum Zitat Ho JD, Dawes DM, Bultmann LL, Moscati RM, Janchar TA, Miner JR. Prolonged TASER use on exhausted humans does not worsen markers of acidosis. Am J Emerg Med. 2009;27:413–8.PubMed Ho JD, Dawes DM, Bultmann LL, Moscati RM, Janchar TA, Miner JR. Prolonged TASER use on exhausted humans does not worsen markers of acidosis. Am J Emerg Med. 2009;27:413–8.PubMed
59.
Zurück zum Zitat Ho JD, Dawes DM, Cole JB, Hottinger JC, Overton KG, Miner JR. Lactate and pH evaluation in exhausted humans with prolonged TASER X26 exposure or continued exertion. Forensic Sci Int. 2009;190:80–6.PubMed Ho JD, Dawes DM, Cole JB, Hottinger JC, Overton KG, Miner JR. Lactate and pH evaluation in exhausted humans with prolonged TASER X26 exposure or continued exertion. Forensic Sci Int. 2009;190:80–6.PubMed
60.
Zurück zum Zitat Ideker RE, Dosdall DJ. Can the direct cardiac effects of the electric pulses generated by the TASER X26 cause immediate or delayed sudden cardiac arrest in normal adults? Am J Forensic Med Pathol. 2007;28:195–201.PubMed Ideker RE, Dosdall DJ. Can the direct cardiac effects of the electric pulses generated by the TASER X26 cause immediate or delayed sudden cardiac arrest in normal adults? Am J Forensic Med Pathol. 2007;28:195–201.PubMed
61.
Zurück zum Zitat Hoffa M, Ludwig C. Einige neue Versuche über Herzbewegungen. Z Ration Med. 1850;9:107–44. Hoffa M, Ludwig C. Einige neue Versuche über Herzbewegungen. Z Ration Med. 1850;9:107–44.
62.
Zurück zum Zitat Kunz SN, Brandtner H, Monticelli F. Electrical current in the human body – effect, fields of application and forensic evidence. Rechtsmedizin. 2012;6:495–505. Kunz SN, Brandtner H, Monticelli F. Electrical current in the human body – effect, fields of application and forensic evidence. Rechtsmedizin. 2012;6:495–505.
63.
Zurück zum Zitat International Electrotechnical Commission. Household and similar electrical appliances—safety—part 2—76: particular requirements for electric fence energizers. 2.1 ed. IEC 60335-2-76. Geneva: IEC; 2012. International Electrotechnical Commission. Household and similar electrical appliances—safety—part 2—76: particular requirements for electric fence energizers. 2.1 ed. IEC 60335-2-76. Geneva: IEC; 2012.
64.
Zurück zum Zitat International Electrotechnical Commission.. Medical electrical equipment—part 1: general requirements for basic safety and essential performance. IEC 60601-1:2005+A1. Geneva: IEC; 2012. International Electrotechnical Commission.. Medical electrical equipment—part 1: general requirements for basic safety and essential performance. IEC 60601-1:2005+A1. Geneva: IEC; 2012.
65.
Zurück zum Zitat International Electrotechnical Commission. Effects of current on human beings and livestock: part 1—general aspects. IEC 60479-1. Geneva: IEC; 2005. International Electrotechnical Commission. Effects of current on human beings and livestock: part 1—general aspects. IEC 60479-1. Geneva: IEC; 2005.
66.
Zurück zum Zitat International Electrotechnical Commission. Effects of current on human beings and livestock: part 2—special aspects. IEC 60479-2. Geneva: IEC; 2007. International Electrotechnical Commission. Effects of current on human beings and livestock: part 2—special aspects. IEC 60479-2. Geneva: IEC; 2007.
67.
Zurück zum Zitat Nimunkar AJ, Webster JG. Safety of pulsed electric devices. Physiol Meas. 2009;30:101–14.PubMed Nimunkar AJ, Webster JG. Safety of pulsed electric devices. Physiol Meas. 2009;30:101–14.PubMed
68.
Zurück zum Zitat Panescu D, Nerheim M, Kroll M. Electrical safety of conducted electrical weapons relative to requirements of relevant electrical standards. Conf Proc IEEE Eng Med Biol Soc 2013. 2013. pp. 5342–7. Panescu D, Nerheim M, Kroll M. Electrical safety of conducted electrical weapons relative to requirements of relevant electrical standards. Conf Proc IEEE Eng Med Biol Soc 2013. 2013. pp. 5342–7.
69.
Zurück zum Zitat Chandrasekera PC, Pippin JJ. The human subject: an integrative animal model for the 21(st) century heart failure research. Am J Transl Res. 2015;7:1636–47.PubMedPubMedCentral Chandrasekera PC, Pippin JJ. The human subject: an integrative animal model for the 21(st) century heart failure research. Am J Transl Res. 2015;7:1636–47.PubMedPubMedCentral
70.
Zurück zum Zitat Langley G. The validity of animal experiments in medical research. RSDA. 2009;1:161–8. Langley G. The validity of animal experiments in medical research. RSDA. 2009;1:161–8.
71.
Zurück zum Zitat Pippin JJ. Taser research in pigs not helpful. J Am Coll Cardiol. 2007;49:731–2.PubMed Pippin JJ. Taser research in pigs not helpful. J Am Coll Cardiol. 2007;49:731–2.PubMed
72.
Zurück zum Zitat Pound P, Ebrahim S, Sandercock P, Bracken MB, Roberts I. Where is the evidence that animal research benefits humans? BMJ. 2004;328:514–7.PubMedPubMedCentral Pound P, Ebrahim S, Sandercock P, Bracken MB, Roberts I. Where is the evidence that animal research benefits humans? BMJ. 2004;328:514–7.PubMedPubMedCentral
73.
Zurück zum Zitat Nickel R, Schummer A, Seiferle E, editors. Kreislaufsystem, Haut und Hautorgane. 4th ed. Lehrbuch der Anatomie der Haustiere, Vol. 3. Stuttgart: Parey; 2004. pp. 53–6. Nickel R, Schummer A, Seiferle E, editors. Kreislaufsystem, Haut und Hautorgane. 4th ed. Lehrbuch der Anatomie der Haustiere, Vol. 3. Stuttgart: Parey; 2004. pp. 53–6.
74.
Zurück zum Zitat Allison JS, Qin H, Dosdall DJ, Huang J, Newton JC, Allred JD, Smith WM, Ideker RE. The transmural activation sequence in porcine and canine left ventricle is markedly different during long-duration ventricular fibrillation. J Cardiovasc Electrophysiol. 2007;18:1306–12.PubMed Allison JS, Qin H, Dosdall DJ, Huang J, Newton JC, Allred JD, Smith WM, Ideker RE. The transmural activation sequence in porcine and canine left ventricle is markedly different during long-duration ventricular fibrillation. J Cardiovasc Electrophysiol. 2007;18:1306–12.PubMed
75.
Zurück zum Zitat Brave MA, Lakkireddy D, Kroll M, Panescu D. Validity of the small swine model for human electrical safety risks. Conf Proc IEEE Eng Med Biol Soc. 2016. 2016. pp. 2343–8. Brave MA, Lakkireddy D, Kroll M, Panescu D. Validity of the small swine model for human electrical safety risks. Conf Proc IEEE Eng Med Biol Soc. 2016. 2016. pp. 2343–8.
76.
Zurück zum Zitat Hamlin RL, Burton RR, Leverett SD, Burns JW. Ventricular activation process in minipigs. J Electrocardiol. 1975;8:113–6.PubMed Hamlin RL, Burton RR, Leverett SD, Burns JW. Ventricular activation process in minipigs. J Electrocardiol. 1975;8:113–6.PubMed
77.
Zurück zum Zitat Howe BB, Fehn PA, Pensinger RR. Comparative anatomical studies of the coronary arteries of canine and porcine hearts. I. Free ventricular walls. Acta Anat (Basel). 1968;71:13–21. Howe BB, Fehn PA, Pensinger RR. Comparative anatomical studies of the coronary arteries of canine and porcine hearts. I. Free ventricular walls. Acta Anat (Basel). 1968;71:13–21.
78.
Zurück zum Zitat Kano M, Toyoshi T, Iwasaki S, Kato M, Shimizu M, Ota T. QT PRODACT: usability of miniature pigs in safety pharmacology studies: assessment for drug-induced QT interval prolongation. J Pharmacol Sci. 2005;99:501–11.PubMed Kano M, Toyoshi T, Iwasaki S, Kato M, Shimizu M, Ota T. QT PRODACT: usability of miniature pigs in safety pharmacology studies: assessment for drug-induced QT interval prolongation. J Pharmacol Sci. 2005;99:501–11.PubMed
79.
Zurück zum Zitat Kroll MW, Calkins H, Luceri RM, Graham MA, Heegaard WG. Sensitive swine and TASER electronic control devices. Acad Emerg Med. 2008;15:695–6.PubMed Kroll MW, Calkins H, Luceri RM, Graham MA, Heegaard WG. Sensitive swine and TASER electronic control devices. Acad Emerg Med. 2008;15:695–6.PubMed
80.
Zurück zum Zitat Schnabel PA, Richter J, Schmiedl A, Bach F, Barthels U, Ramsauer B, Gebhard MM, Bretschneider HJ. Patterns of structural deterioration due to ischemia in Purkinje fibres and different layers of the working myocardium. Thorac Cardiovasc Surg. 1991;39:174–82.PubMed Schnabel PA, Richter J, Schmiedl A, Bach F, Barthels U, Ramsauer B, Gebhard MM, Bretschneider HJ. Patterns of structural deterioration due to ischemia in Purkinje fibres and different layers of the working myocardium. Thorac Cardiovasc Surg. 1991;39:174–82.PubMed
81.
Zurück zum Zitat Lakkireddy D, Wallick D, Verma A, Ryschon K, Kowalewski W, Wazni O, Butany J, Martin D, Tchou PJ. Cardiac effects of electrical stun guns: does position of barbs contact make a difference? Pacing Clin Electrophysiol. 2008;31:398–408.PubMed Lakkireddy D, Wallick D, Verma A, Ryschon K, Kowalewski W, Wazni O, Butany J, Martin D, Tchou PJ. Cardiac effects of electrical stun guns: does position of barbs contact make a difference? Pacing Clin Electrophysiol. 2008;31:398–408.PubMed
82.
Zurück zum Zitat Eastman AL, Metzger JC, Pepe PE, Benitez FL, Decker J, Rinnert KJ, Field CA, Friese RS. Conducted electrical devices: a prospective, population-based study of the medical safety of law enforcement use. J Trauma. 2008;64:1567–72.PubMed Eastman AL, Metzger JC, Pepe PE, Benitez FL, Decker J, Rinnert KJ, Field CA, Friese RS. Conducted electrical devices: a prospective, population-based study of the medical safety of law enforcement use. J Trauma. 2008;64:1567–72.PubMed
83.
Zurück zum Zitat Payne-James JJ, Green P, Johmston A. Trends in less-lethal use of force techniques by police services within England and Wales: 2007–2011. Forensic Sci Med Pathol. 2014;10:50–5.PubMed Payne-James JJ, Green P, Johmston A. Trends in less-lethal use of force techniques by police services within England and Wales: 2007–2011. Forensic Sci Med Pathol. 2014;10:50–5.PubMed
85.
Zurück zum Zitat Bozeman WP. Additional information on taser safety. Ann Emerg Med. 2009;54:758–9.PubMed Bozeman WP. Additional information on taser safety. Ann Emerg Med. 2009;54:758–9.PubMed
86.
Zurück zum Zitat Walcott GP, Kroll MW, Ideker RE. Ventricular fibrillation: are swine a sensitive species? J Interv Card Electrophysiol. 2015;42:83–9.PubMed Walcott GP, Kroll MW, Ideker RE. Ventricular fibrillation: are swine a sensitive species? J Interv Card Electrophysiol. 2015;42:83–9.PubMed
87.
Zurück zum Zitat Kroll MW, Lakkireddy DR, Stone JR, Luceri RM. TASER electronic control devices and cardiac arrests: coincidental or causal? Circulation. 2014;129:93–100. Supplement.PubMed Kroll MW, Lakkireddy DR, Stone JR, Luceri RM. TASER electronic control devices and cardiac arrests: coincidental or causal? Circulation. 2014;129:93–100. Supplement.PubMed
88.
Zurück zum Zitat Brewer J, Kroll M. Field statistic overview. In: Kroll M, Ho J, editors. TASER conducted electrical weapons: physiology, pathology, and law. New York City: Springer-Kluwer; 2009. pp. 283–300. Brewer J, Kroll M. Field statistic overview. In: Kroll M, Ho J, editors. TASER conducted electrical weapons: physiology, pathology, and law. New York City: Springer-Kluwer; 2009. pp. 283–300.
89.
Zurück zum Zitat Ho J, Heegaard WG, Dawes DM, Natarajan S, Reardon RF, Miner JR. Unexpected arrest-related deaths in america: 12 months of open source surveillance. West J Emerg Med. 2009;10:68–73.PubMedPubMedCentral Ho J, Heegaard WG, Dawes DM, Natarajan S, Reardon RF, Miner JR. Unexpected arrest-related deaths in america: 12 months of open source surveillance. West J Emerg Med. 2009;10:68–73.PubMedPubMedCentral
90.
Zurück zum Zitat Rita I. Risikoanalyse TASER-X26-Distanzanwendung, Untersuchung in Bezug auf Stromstärken. Graz: Institut für Health Care Engineering, TU Graz; 2009. Rita I. Risikoanalyse TASER-X26-Distanzanwendung, Untersuchung in Bezug auf Stromstärken. Graz: Institut für Health Care Engineering, TU Graz; 2009.
91.
Zurück zum Zitat Baldwin DE, Nagarakanti R, Hardy SP, Jain N, Borne DM, England AR, Nix ED, Daniels CL, Abide WP Jr, Glancy DI. Myocardial infarction after taser exposure. J La State Med Soc. 2010;162:291–2. 294–5.PubMed Baldwin DE, Nagarakanti R, Hardy SP, Jain N, Borne DM, England AR, Nix ED, Daniels CL, Abide WP Jr, Glancy DI. Myocardial infarction after taser exposure. J La State Med Soc. 2010;162:291–2. 294–5.PubMed
92.
Zurück zum Zitat Kornblum RN, Reddy SK. Effects of the taser in fatalities involving police confrontation. J Forensic Sci. 1991;36:434–8.PubMed Kornblum RN, Reddy SK. Effects of the taser in fatalities involving police confrontation. J Forensic Sci. 1991;36:434–8.PubMed
93.
Zurück zum Zitat Naunheim RS, Treaster M, Aubin C. Ventricular fibrillation in a man shot with a taser. Emerg Med J. 2010;27:645–6.PubMed Naunheim RS, Treaster M, Aubin C. Ventricular fibrillation in a man shot with a taser. Emerg Med J. 2010;27:645–6.PubMed
94.
Zurück zum Zitat Strote J, Range Hutson H. Taser use in restraint-related deaths. Prehosp Emerg Care. 2006;10:447–50.PubMed Strote J, Range Hutson H. Taser use in restraint-related deaths. Prehosp Emerg Care. 2006;10:447–50.PubMed
95.
Zurück zum Zitat Zipes DP. Sudden cardiac arrest and death following application of shocks from a TASER electronic control device. Circulation. 2012;125:2417–22.PubMed Zipes DP. Sudden cardiac arrest and death following application of shocks from a TASER electronic control device. Circulation. 2012;125:2417–22.PubMed
96.
Zurück zum Zitat Haegli LM, Sterns LD, Adam DC, Leather RA. Effect of a taser shot to the chest of a patient with an implantable defibrillator. Heart Rhythm. 2006;3:339–41. Haegli LM, Sterns LD, Adam DC, Leather RA. Effect of a taser shot to the chest of a patient with an implantable defibrillator. Heart Rhythm. 2006;3:339–41.
97.
Zurück zum Zitat Lakkireddy D, Khasnis A, Antenacci J, Ryshcon K, Chung MK, Wallick D, Kowalewski W, Patel D, Micochova H, Kondur A, Vacek J, Martin D, Natale A, Tchou P. Do electrical stun guns (TASER X26) affect the functional integrity of implanted pacemakers and defibrillators? Europace. 2007;9:551–6.PubMed Lakkireddy D, Khasnis A, Antenacci J, Ryshcon K, Chung MK, Wallick D, Kowalewski W, Patel D, Micochova H, Kondur A, Vacek J, Martin D, Natale A, Tchou P. Do electrical stun guns (TASER X26) affect the functional integrity of implanted pacemakers and defibrillators? Europace. 2007;9:551–6.PubMed
98.
Zurück zum Zitat Leitgeb N, Niedermayr F, Neubauer R. Interference of implanted cardiac pacemakers with TASER X26 dart mode application. Biomed Tech (Berl). 2012;2057:201–6. Leitgeb N, Niedermayr F, Neubauer R. Interference of implanted cardiac pacemakers with TASER X26 dart mode application. Biomed Tech (Berl). 2012;2057:201–6.
99.
Zurück zum Zitat Vanga SR, Bommana S, Kroll MW, Swerdlow C, Lakkireddy D. Taser conducted electrical weapons and implanted pacemakers and defibrillators. ConfProc IEEE Eng Med Biol Soc 2009. 2009. pp. 3199–204. Vanga SR, Bommana S, Kroll MW, Swerdlow C, Lakkireddy D. Taser conducted electrical weapons and implanted pacemakers and defibrillators. ConfProc IEEE Eng Med Biol Soc 2009. 2009. pp. 3199–204.
Metadaten
Titel
A comparative brief on conducted electrical weapon safety
verfasst von
PD. Dr. Sebastian N. Kunz
PD. Dr. Jiri Adamec
Publikationsdatum
01.02.2018
Verlag
Springer Vienna
Erschienen in
Wiener Medizinische Wochenschrift / Ausgabe 7-8/2019
Print ISSN: 0043-5341
Elektronische ISSN: 1563-258X
DOI
https://doi.org/10.1007/s10354-018-0616-4

Weitere Artikel der Ausgabe 7-8/2019

Wiener Medizinische Wochenschrift 7-8/2019 Zur Ausgabe