Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma

verfasst von: Kyoko Ishida, Naoya Moroto, Kazuhiro Murata, Tetsuya Yamamoto

Erschienen in: Japanese Journal of Ophthalmology | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To evaluate the effect of filtering surgery using the EX-PRESS device on intraocular pressure (IOP), flare count, anterior chamber (AC) depth, and the corneal endothelium in primary open-angle glaucoma (POAG), including normal-tension glaucoma (NTG).

Patients and methods

The study comprised 63 consecutive patients with POAG or NTG. They underwent complete ophthalmologic examinations, including measurement of visual acuity (VA), IOP, flare count, AC depth, and cell density of the corneal endothelium (CE). Two outcomes were used for surgical success: outcome 1 was defined as a ≥20% reduction in the IOP from the preoperative value, with an IOP ≥ 5 mmHg but ≤18 mmHg, and outcome 2 was defined as a ≥20% reduction in the IOP, with an IOP ≥ 5 mmHg but ≤15 mmHg.

Results

The IOP significantly decreased from 17.7 preoperatively to 12.4 mmHg postoperatively (P < 0.0001). The success rates for outcome 1 at 24 months were 81.3 and 46.7% for POAG and NTG, respectively (P = 0.0065); the corresponding success rates for outcome 2 were 79.4 and 46.7% (P = 0.0120). The flare count significantly increased on postoperative day 1 (P = 0.0002) but recovered to insignificant levels by day 3 (P = 0.0686). A transient decrease in AC depth was observed by 4 weeks after surgery (P = 0.0017). The CE changed from 2529 preoperatively to 2428/mm2 at 24 months (P = 0.0089).

Conclusion

The advantage of filtering surgery using the EX-PRESS device includes reduced inflammation, and the disadvantages include loss of the CE and reduced effectiveness of NTG.
Literatur
1.
Zurück zum Zitat Shaarawy T, Goldberg I, Fechtner R. EX-PRESS glaucoma filtration device: review of clinical experience and comparison with trabeculectomy. Surv Ophthalmol. 2015;60:327–45.CrossRefPubMed Shaarawy T, Goldberg I, Fechtner R. EX-PRESS glaucoma filtration device: review of clinical experience and comparison with trabeculectomy. Surv Ophthalmol. 2015;60:327–45.CrossRefPubMed
2.
Zurück zum Zitat Coleman AL. Advances in glaucoma treatment and management: surgery. Invest Ophthalmol Vis Sci. 2012;53:2491–4.CrossRef Coleman AL. Advances in glaucoma treatment and management: surgery. Invest Ophthalmol Vis Sci. 2012;53:2491–4.CrossRef
3.
Zurück zum Zitat Mariotti C, Dahan E, Nicolai M, Levitz L, Bouee S. Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device. Eye. 2014;28:1–8.CrossRefPubMed Mariotti C, Dahan E, Nicolai M, Levitz L, Bouee S. Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device. Eye. 2014;28:1–8.CrossRefPubMed
4.
Zurück zum Zitat Wang W, Zhou M, Huang W, Zhang X. Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis. PLoS One. 2013;8:1–6.CrossRef Wang W, Zhou M, Huang W, Zhang X. Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis. PLoS One. 2013;8:1–6.CrossRef
5.
Zurück zum Zitat Garg SJ, Kanitkar K, Weichel E, Fischer D. Trauma-induced extrusion of an Ex-PRESS glaucoma shunt presenting as an intraocular foreign body. Arch Ophthalmol. 2015;123:1270–2.CrossRef Garg SJ, Kanitkar K, Weichel E, Fischer D. Trauma-induced extrusion of an Ex-PRESS glaucoma shunt presenting as an intraocular foreign body. Arch Ophthalmol. 2015;123:1270–2.CrossRef
7.
Zurück zum Zitat Stewart RM, Diamond JG, Ashmore ED, Ayyala RS. Complications following ex-press glaucoma shunt implantation. Am J Ophthalmol. 2005;140:340–1.CrossRefPubMed Stewart RM, Diamond JG, Ashmore ED, Ayyala RS. Complications following ex-press glaucoma shunt implantation. Am J Ophthalmol. 2005;140:340–1.CrossRefPubMed
8.
Zurück zum Zitat Wamsley S, Moster MR, Rai S, Alvim HS, Fontanarosa J. Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study. Am J Ophthalmol. 2004;138:1049–51.CrossRefPubMed Wamsley S, Moster MR, Rai S, Alvim HS, Fontanarosa J. Results of the use of the Ex-PRESS miniature glaucoma implant in technically challenging, advanced glaucoma cases: a clinical pilot study. Am J Ophthalmol. 2004;138:1049–51.CrossRefPubMed
9.
Zurück zum Zitat Dahan E, Carmichael TR. Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma. 2005;14:98–102.CrossRefPubMed Dahan E, Carmichael TR. Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma. 2005;14:98–102.CrossRefPubMed
10.
Zurück zum Zitat Salim S. Ex-PRESS glaucoma filtration device-surgical technique and outcomes. Int Ophthalmol Clin. 2011;51:83–94.CrossRefPubMed Salim S. Ex-PRESS glaucoma filtration device-surgical technique and outcomes. Int Ophthalmol Clin. 2011;51:83–94.CrossRefPubMed
11.
Zurück zum Zitat Francis BA, Singh K, Lin SC, Hodapp E, Jamoel HD, Samples JR, et al. Novel glaucoma procedures: a report by the American academy of ophthalmology. Ophthalmology. 2011;118:1466–80.PubMed Francis BA, Singh K, Lin SC, Hodapp E, Jamoel HD, Samples JR, et al. Novel glaucoma procedures: a report by the American academy of ophthalmology. Ophthalmology. 2011;118:1466–80.PubMed
12.
Zurück zum Zitat Netland PA, Sarkisian SR Jr, Moster MR, Ahmed II, Condon G, Salim S, et al. Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study). Am J Ophthalmol. 2014;157:433–40.CrossRefPubMed Netland PA, Sarkisian SR Jr, Moster MR, Ahmed II, Condon G, Salim S, et al. Randomized, prospective, comparative trial of EX-PRESS glaucoma filtration device versus trabeculectomy (XVT study). Am J Ophthalmol. 2014;157:433–40.CrossRefPubMed
13.
Zurück zum Zitat de Jong L, Lafuma A, Aguadé AS, Berdeaux G. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol. 2011;5:527–33.PubMedPubMedCentral de Jong L, Lafuma A, Aguadé AS, Berdeaux G. Five-year extension of a clinical trial comparing the EX-PRESS glaucoma filtration device and trabeculectomy in primary open-angle glaucoma. Clin Ophthalmol. 2011;5:527–33.PubMedPubMedCentral
14.
Zurück zum Zitat Kanner EM, Netland PA, Sarkisian SR Jr, Du H. Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery. J Glaucoma. 2009;18:488–91.CrossRefPubMed Kanner EM, Netland PA, Sarkisian SR Jr, Du H. Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery. J Glaucoma. 2009;18:488–91.CrossRefPubMed
15.
Zurück zum Zitat Maris PJ Jr, Ishida K, Netland PA. Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap. J Glaucoma. 2007;16:14–9.CrossRefPubMed Maris PJ Jr, Ishida K, Netland PA. Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap. J Glaucoma. 2007;16:14–9.CrossRefPubMed
16.
Zurück zum Zitat Lankaranian D, Razeghinejad MR, Prasad A, Fakhraie G, Freitas DJ, Ichhpujani P, et al. Intermediate-term results of the Ex-PRESS miniature glaucoma implant under a scleral flap in previously operated eyes. Clin Exp Ophthalmol. 2011;39:421–8.CrossRefPubMed Lankaranian D, Razeghinejad MR, Prasad A, Fakhraie G, Freitas DJ, Ichhpujani P, et al. Intermediate-term results of the Ex-PRESS miniature glaucoma implant under a scleral flap in previously operated eyes. Clin Exp Ophthalmol. 2011;39:421–8.CrossRefPubMed
17.
Zurück zum Zitat Bissig A, Feusier M, Mermoud A, Roy S. Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma. Int Ophthalmol. 2010;30:661–8.CrossRefPubMed Bissig A, Feusier M, Mermoud A, Roy S. Deep sclerectomy with the Ex-PRESS X-200 implant for the surgical treatment of glaucoma. Int Ophthalmol. 2010;30:661–8.CrossRefPubMed
18.
Zurück zum Zitat Dahan E, Ben Simon GJ, Lafuma A. Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised study. Eye. 2012;26:703–10.CrossRefPubMedPubMedCentral Dahan E, Ben Simon GJ, Lafuma A. Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised study. Eye. 2012;26:703–10.CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat De Feo F, Bagnis A, Bricola G, Scotto R, Traverso CE. Efficacy and safety of a steel drainage device implanted under a scleral flap. Can J Ophthalmol. 2009;44:457–62.CrossRefPubMed De Feo F, Bagnis A, Bricola G, Scotto R, Traverso CE. Efficacy and safety of a steel drainage device implanted under a scleral flap. Can J Ophthalmol. 2009;44:457–62.CrossRefPubMed
20.
Zurück zum Zitat Hendrick AM, Kahook MY. Ex-PRESS mini glaucoma shunt: surgical technique and review of clinical experience. Expert Rev Med Device. 2008;5:673–7.CrossRef Hendrick AM, Kahook MY. Ex-PRESS mini glaucoma shunt: surgical technique and review of clinical experience. Expert Rev Med Device. 2008;5:673–7.CrossRef
21.
Zurück zum Zitat Moisseiev E, Zunz E, Tzur R, Kurtz S, Shemesh G. Standard trabeculectomy and Ex-PRESS miniature glaucoma shunt: a comparative study and literature review. J Glaucoma. 2015;24:410–6.CrossRefPubMedPubMedCentral Moisseiev E, Zunz E, Tzur R, Kurtz S, Shemesh G. Standard trabeculectomy and Ex-PRESS miniature glaucoma shunt: a comparative study and literature review. J Glaucoma. 2015;24:410–6.CrossRefPubMedPubMedCentral
22.
Zurück zum Zitat Beltran-Agullo L, Trope GE, Jin Y, Wagschal LD, Jinapriya D, Buys YM. Comparison of visual recovery following Ex-PRESS versus trabeculectomy: results of a prospective randomized controlled trial. J Glaucoma. 2015;24:181–6.CrossRefPubMed Beltran-Agullo L, Trope GE, Jin Y, Wagschal LD, Jinapriya D, Buys YM. Comparison of visual recovery following Ex-PRESS versus trabeculectomy: results of a prospective randomized controlled trial. J Glaucoma. 2015;24:181–6.CrossRefPubMed
23.
Zurück zum Zitat Good TJ, Kahook MY. Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy. Am J Ophthalmol. 2011;151:507–13.CrossRefPubMed Good TJ, Kahook MY. Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy. Am J Ophthalmol. 2011;151:507–13.CrossRefPubMed
24.
Zurück zum Zitat Kato N, Takahashi G, Kumegawa K, Kabata Y, Tsuneoka H. Indications and postoperative treatment for Ex-PRESS® insertion in Japanese patients with glaucoma: comparison with standard trabeculectomy. Clin Ophthalmol. 2015;18:1491–8.CrossRef Kato N, Takahashi G, Kumegawa K, Kabata Y, Tsuneoka H. Indications and postoperative treatment for Ex-PRESS® insertion in Japanese patients with glaucoma: comparison with standard trabeculectomy. Clin Ophthalmol. 2015;18:1491–8.CrossRef
25.
Zurück zum Zitat Mendoza-Mendieta ME, López-Venegas AP, Valdés-Casas G. Comparison between the EX-PRESS P-50 implant and trabeculectomy in patients with open-angle glaucoma. Clin Ophthalmol. 2016;10:269–76.CrossRefPubMedPubMedCentral Mendoza-Mendieta ME, López-Venegas AP, Valdés-Casas G. Comparison between the EX-PRESS P-50 implant and trabeculectomy in patients with open-angle glaucoma. Clin Ophthalmol. 2016;10:269–76.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Sugiyama T, Shibata M, Kojima S, Ueki M, Ikeda T. The first report on intermediate-term outcome of Ex-PRESS glaucoma filtration device implanted under scleral flap in Japanese patients. Clin Ophthalmol. 2011;5:1063–6.CrossRefPubMedPubMedCentral Sugiyama T, Shibata M, Kojima S, Ueki M, Ikeda T. The first report on intermediate-term outcome of Ex-PRESS glaucoma filtration device implanted under scleral flap in Japanese patients. Clin Ophthalmol. 2011;5:1063–6.CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Wagschal LD, Trope GE, Jinapriya D, Jin YP, Buys YM. Prospective randomized study comparing Ex-PRESS to trabeculectomy: 1-year results. J Glaucoma. 2015;24:624–9.CrossRefPubMed Wagschal LD, Trope GE, Jinapriya D, Jin YP, Buys YM. Prospective randomized study comparing Ex-PRESS to trabeculectomy: 1-year results. J Glaucoma. 2015;24:624–9.CrossRefPubMed
28.
Zurück zum Zitat Jongsareejit B, Tomidokoro A, Mimura T, Tomita G, Shirato S, Araie M. Efficacy and complications after trabeculectomy with mitomycin C in normal-tension glaucoma. Jpn J Ophthalmol. 2005;49:223–7.CrossRefPubMed Jongsareejit B, Tomidokoro A, Mimura T, Tomita G, Shirato S, Araie M. Efficacy and complications after trabeculectomy with mitomycin C in normal-tension glaucoma. Jpn J Ophthalmol. 2005;49:223–7.CrossRefPubMed
29.
Zurück zum Zitat Iverson SM, Schultz SK, Shi W, Feuer WJ, Greenfield DS. Effectiveness of single-digit IOP targets on decreasing global and localized visual field progression after filtration surgery in eyes with progressive normal-tension glaucoma. J Glaucoma. 2016;25:408–14 (published online ahead of print February 25, 2015).CrossRefPubMed Iverson SM, Schultz SK, Shi W, Feuer WJ, Greenfield DS. Effectiveness of single-digit IOP targets on decreasing global and localized visual field progression after filtration surgery in eyes with progressive normal-tension glaucoma. J Glaucoma. 2016;25:408–14 (published online ahead of print February 25, 2015).CrossRefPubMed
30.
Zurück zum Zitat Aoyama A, Ishida K, Sawada A, Yamamoto T. Target intraocular pressure for stability of visual field loss progression in normal-tension glaucoma. Jpn J Ophthalmol. 2010;54:117–23.CrossRefPubMed Aoyama A, Ishida K, Sawada A, Yamamoto T. Target intraocular pressure for stability of visual field loss progression in normal-tension glaucoma. Jpn J Ophthalmol. 2010;54:117–23.CrossRefPubMed
31.
Zurück zum Zitat Shigeeda T, Tomidokoro A, Araie M, Koseki N, Yamamoto S. Long-term follow-up of visual field progression after trabeculectomy in progressive normal-tension glaucoma. Ophthalmology. 2012;109:766–70.CrossRef Shigeeda T, Tomidokoro A, Araie M, Koseki N, Yamamoto S. Long-term follow-up of visual field progression after trabeculectomy in progressive normal-tension glaucoma. Ophthalmology. 2012;109:766–70.CrossRef
32.
Zurück zum Zitat Schultz SK, Iverson SM, Shi W, Greenfield DS. Safety and efficacy of achieving single-digit intraocular pressure targets with filtration surgery in eyes with progressive normal-tension glaucoma. J Glaucoma. 2016;25:217–22 (published online ahead of print September 26, 2014).CrossRefPubMedPubMedCentral Schultz SK, Iverson SM, Shi W, Greenfield DS. Safety and efficacy of achieving single-digit intraocular pressure targets with filtration surgery in eyes with progressive normal-tension glaucoma. J Glaucoma. 2016;25:217–22 (published online ahead of print September 26, 2014).CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Chiou AG, Mermoud A, Jewelewicz DA. Post-operative inflammation following deep sclerectomy with collagen implant versus standard trabeculectomy. Graefes Arch Clin Exp Ophthalmol. 1998;236:593–6.CrossRefPubMed Chiou AG, Mermoud A, Jewelewicz DA. Post-operative inflammation following deep sclerectomy with collagen implant versus standard trabeculectomy. Graefes Arch Clin Exp Ophthalmol. 1998;236:593–6.CrossRefPubMed
34.
Zurück zum Zitat Inatani M, Ogata-Iwao M, Takihara Y, Iwao K, Inoue T, Kasaoka N, et al. A prospective study of postoperative aqueous flare in trabeculectomy alone versus phacotrabeculectomy [in Japanese]. Nippon Ganka Gakkai Zasshi. 2012;116:856–61.PubMed Inatani M, Ogata-Iwao M, Takihara Y, Iwao K, Inoue T, Kasaoka N, et al. A prospective study of postoperative aqueous flare in trabeculectomy alone versus phacotrabeculectomy [in Japanese]. Nippon Ganka Gakkai Zasshi. 2012;116:856–61.PubMed
35.
Zurück zum Zitat Ustundag C, Diestelhorst M. Effect of mitomycin C on aqueous humor flow, flare and intraocular pressure in eyes with glaucoma 2 years after trabeculectomy. Graefes Arch Clin Exp Ophthalmol. 1998;236:734–8.CrossRefPubMed Ustundag C, Diestelhorst M. Effect of mitomycin C on aqueous humor flow, flare and intraocular pressure in eyes with glaucoma 2 years after trabeculectomy. Graefes Arch Clin Exp Ophthalmol. 1998;236:734–8.CrossRefPubMed
36.
Zurück zum Zitat Siriwardena D, Kotecha A, Minassian D, Dart JK, Khaw PT. Anterior chamber flare after trabeculectomy and after phacoemulsification. Br J Ophthalmol. 2000;84:1056–7.CrossRefPubMedPubMedCentral Siriwardena D, Kotecha A, Minassian D, Dart JK, Khaw PT. Anterior chamber flare after trabeculectomy and after phacoemulsification. Br J Ophthalmol. 2000;84:1056–7.CrossRefPubMedPubMedCentral
37.
Zurück zum Zitat O’Brart DP, Rowlands E, Islam N, Noury AM. A randomised, prospective study comparing trabeculectomy augmented with antimetabolites with a viscocanalostomy technique for the management of open angle glaucoma uncontrolled by medical therapy. Br J Ophthalmol. 2002;86:748–54.CrossRefPubMedPubMedCentral O’Brart DP, Rowlands E, Islam N, Noury AM. A randomised, prospective study comparing trabeculectomy augmented with antimetabolites with a viscocanalostomy technique for the management of open angle glaucoma uncontrolled by medical therapy. Br J Ophthalmol. 2002;86:748–54.CrossRefPubMedPubMedCentral
38.
Zurück zum Zitat Inoue T, Kawaji T, Inatani M, Kameda T, Yoshimura N, Tanihara H. Simultaneous increases in multiple proinflammatory cytokines in the aqueous humor in pseudophakic glaucomatous eyes. J Cataract Refract Surg. 2012;38:1389–97.CrossRefPubMed Inoue T, Kawaji T, Inatani M, Kameda T, Yoshimura N, Tanihara H. Simultaneous increases in multiple proinflammatory cytokines in the aqueous humor in pseudophakic glaucomatous eyes. J Cataract Refract Surg. 2012;38:1389–97.CrossRefPubMed
39.
Zurück zum Zitat Ooi KG, Galatowicz G, Towler HM, Lightman SL, Calder VL. Multiplex cytokine detection versus ELISA for aqueous humor: IL-5, IL-10, and IFNgamma profiles in uveitis. Invest Ophthalmol Vis Sci. 2006;47:272–7.CrossRefPubMed Ooi KG, Galatowicz G, Towler HM, Lightman SL, Calder VL. Multiplex cytokine detection versus ELISA for aqueous humor: IL-5, IL-10, and IFNgamma profiles in uveitis. Invest Ophthalmol Vis Sci. 2006;47:272–7.CrossRefPubMed
40.
Zurück zum Zitat Sharma RK, Rogojina AT, Chalam KV. Multiplex immunoassay analysis of biomarkers in clinically accessible quantities of human aqueous humor. Mol Vis. 2009;15:60–9.PubMedPubMedCentral Sharma RK, Rogojina AT, Chalam KV. Multiplex immunoassay analysis of biomarkers in clinically accessible quantities of human aqueous humor. Mol Vis. 2009;15:60–9.PubMedPubMedCentral
41.
Zurück zum Zitat Kawai M, Inoue T, Inatani M, Tsuboi N, Shobayashi K, Matsukawa A, et al. Elevated levels of monocyte chemoattractant protein-1 in the aqueous humor after phacoemulsification. Invest Ophthalmol Vis Sci. 2012;53:7951–60.CrossRefPubMed Kawai M, Inoue T, Inatani M, Tsuboi N, Shobayashi K, Matsukawa A, et al. Elevated levels of monocyte chemoattractant protein-1 in the aqueous humor after phacoemulsification. Invest Ophthalmol Vis Sci. 2012;53:7951–60.CrossRefPubMed
42.
Zurück zum Zitat Kruger A, Schauersberger J, Findl O, Petternel V, Svolba G, Amon M. Postoperative inflammation after clear corneal and sclerocorneal incisions. J Cataract Refract Surg. 1998;24:524–8.CrossRefPubMed Kruger A, Schauersberger J, Findl O, Petternel V, Svolba G, Amon M. Postoperative inflammation after clear corneal and sclerocorneal incisions. J Cataract Refract Surg. 1998;24:524–8.CrossRefPubMed
43.
Zurück zum Zitat Laing AE, Seibold LK, SooHoo JR, Kahook MY. Evaluation of bleb characteristics after implantation of the EX-PRESS™ glaucoma filtration device. Mol Vis. 2012;18:10–3.PubMedPubMedCentral Laing AE, Seibold LK, SooHoo JR, Kahook MY. Evaluation of bleb characteristics after implantation of the EX-PRESS™ glaucoma filtration device. Mol Vis. 2012;18:10–3.PubMedPubMedCentral
44.
Zurück zum Zitat De Feo F, Jacobson S, Nyska A, Pagani P, Traverso CE. Histological biocompatibility of a stainless steel miniature glaucoma drainage device in humans: a case report. Toxicol Pathol. 2009;37:512–6.CrossRefPubMed De Feo F, Jacobson S, Nyska A, Pagani P, Traverso CE. Histological biocompatibility of a stainless steel miniature glaucoma drainage device in humans: a case report. Toxicol Pathol. 2009;37:512–6.CrossRefPubMed
45.
Zurück zum Zitat Hammel N, Lusky M, Kaiserman I, Robinson A, Bahar I. Changes in anterior segment parameters after insertion of Ex-PRESS miniature glaucoma implant. J Glaucoma. 2012;22:565–8.CrossRef Hammel N, Lusky M, Kaiserman I, Robinson A, Bahar I. Changes in anterior segment parameters after insertion of Ex-PRESS miniature glaucoma implant. J Glaucoma. 2012;22:565–8.CrossRef
46.
Zurück zum Zitat Bourne WM, Nelson LR, Hodge DO. Central corneal endothelial cell changes over a ten-year period. Invest Ophthalmol Vis Sci. 1997;38:779–82.PubMed Bourne WM, Nelson LR, Hodge DO. Central corneal endothelial cell changes over a ten-year period. Invest Ophthalmol Vis Sci. 1997;38:779–82.PubMed
47.
Zurück zum Zitat Casini G, Loiudice P, Pellegrini M, Aframeli AT, Martinelli P, Passani A, et al. Trabeculectomy versus EX-PRESS shunt versus Ahmed Valve implant: short-term effects on corneal endothelial cells. Am J Ophthalmol. 2015;160:1185–90.CrossRefPubMed Casini G, Loiudice P, Pellegrini M, Aframeli AT, Martinelli P, Passani A, et al. Trabeculectomy versus EX-PRESS shunt versus Ahmed Valve implant: short-term effects on corneal endothelial cells. Am J Ophthalmol. 2015;160:1185–90.CrossRefPubMed
48.
Zurück zum Zitat Konopińska J, Deniziak M, Saeed E, Bartczak A, Zalewska R, Mariak Z, et al. Prospective randomized study comparing combined phaco-ExPress and phacotrabeculectomy in open angle glaucoma treatment: 12-month follow-up. J Ophthalmol. 2015 (Epub Jun 7). Konopińska J, Deniziak M, Saeed E, Bartczak A, Zalewska R, Mariak Z, et al. Prospective randomized study comparing combined phaco-ExPress and phacotrabeculectomy in open angle glaucoma treatment: 12-month follow-up. J Ophthalmol. 2015 (Epub Jun 7).
49.
Zurück zum Zitat Tojo N, Hayashi A, Miyakoshi A. Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device. Clin Ophthalmol. 2015;17:499–502. Tojo N, Hayashi A, Miyakoshi A. Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device. Clin Ophthalmol. 2015;17:499–502.
50.
Zurück zum Zitat Arnavielle S, Lafontaine PO, Bidot S, Creuzot-Garcher C, D’Athis P, Bron AM. Corneal endothelial cell changes after trabeculectomy and deep sclerectomy. J Glaucoma. 2007;16:324–8.CrossRefPubMed Arnavielle S, Lafontaine PO, Bidot S, Creuzot-Garcher C, D’Athis P, Bron AM. Corneal endothelial cell changes after trabeculectomy and deep sclerectomy. J Glaucoma. 2007;16:324–8.CrossRefPubMed
51.
Zurück zum Zitat Soro-Martínez MI, Villegas-Pérez MP, Sobrado-Calvo P, Ruiz-Gómez JM, Miralles de Imperial, Mora-Figueroa J. Corneal endothelial cell loss after trabeculectomy or after phacoemulsification, IOL implantation and trabeculectomy in 1 or 2 steps. Graefes Arch Clin Exp Ophthalmol. 2010;248:249–56.CrossRefPubMed Soro-Martínez MI, Villegas-Pérez MP, Sobrado-Calvo P, Ruiz-Gómez JM, Miralles de Imperial, Mora-Figueroa J. Corneal endothelial cell loss after trabeculectomy or after phacoemulsification, IOL implantation and trabeculectomy in 1 or 2 steps. Graefes Arch Clin Exp Ophthalmol. 2010;248:249–56.CrossRefPubMed
52.
Zurück zum Zitat Storr-Paulsen T, Norregaard JC, Ahmed S, Storr-Paulsen A. Corneal endothelial cell loss after mitomycin C-augmented trabeculectomy. J Glaucoma. 2008;17:654–7.CrossRefPubMed Storr-Paulsen T, Norregaard JC, Ahmed S, Storr-Paulsen A. Corneal endothelial cell loss after mitomycin C-augmented trabeculectomy. J Glaucoma. 2008;17:654–7.CrossRefPubMed
53.
Zurück zum Zitat Macdonald JM, Geroski DH, Edelhauser HF. Effect of inflammation on the corneal endothelial pump and barrier. Curr Eye Res. 1987;6:1125–32.CrossRefPubMed Macdonald JM, Geroski DH, Edelhauser HF. Effect of inflammation on the corneal endothelial pump and barrier. Curr Eye Res. 1987;6:1125–32.CrossRefPubMed
Metadaten
Titel
Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma
verfasst von
Kyoko Ishida
Naoya Moroto
Kazuhiro Murata
Tetsuya Yamamoto
Publikationsdatum
03.04.2017
Verlag
Springer Japan
Erschienen in
Japanese Journal of Ophthalmology / Ausgabe 4/2017
Print ISSN: 0021-5155
Elektronische ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-017-0512-2

Weitere Artikel der Ausgabe 4/2017

Japanese Journal of Ophthalmology 4/2017 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.