A Comparative Study of Different EEG Reference Choices for Diagnosing Unipolar Depression

verfasst von: Wajid Mumtaz, Aamir Saeed Malik

Erschienen in: Brain Topography | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

The choice of an electroencephalogram (EEG) reference has fundamental importance and could be critical during clinical decision-making because an impure EEG reference could falsify the clinical measurements and subsequent inferences. In this research, the suitability of three EEG references was compared while classifying depressed and healthy brains using a machine-learning (ML)-based validation method. In this research, the EEG data of 30 unipolar depressed subjects and 30 age-matched healthy controls were recorded. The EEG data were analyzed in three different EEG references, the link-ear reference (LE), average reference (AR), and reference electrode standardization technique (REST). The EEG-based functional connectivity (FC) was computed. Also, the graph-based measures, such as the distances between nodes, minimum spanning tree, and maximum flow between the nodes for each channel pair, were calculated. An ML scheme provided a mechanism to compare the performances of the extracted features that involved a general framework such as the feature extraction (graph-based theoretic measures), feature selection, classification, and validation. For comparison purposes, the performance metrics such as the classification accuracies, sensitivities, specificities, and F scores were computed. When comparing the three references, the diagnostic accuracy showed better performances during the REST, while the LE and AR showed less discrimination between the two groups. Based on the results, it can be concluded that the choice of appropriate reference is critical during the clinical scenario. The REST reference is recommended for future applications of EEG-based diagnosis of mental illnesses.
Literatur
Zurück zum Zitat Acharya UR, Sudarshan VK, Adeli H, Santhosh J, Koh JE, Adeli A (2015a) Computer-aided diagnosis of depression using EEG signals. Euro Neurol 73(5–6):329–336CrossRef Acharya UR, Sudarshan VK, Adeli H, Santhosh J, Koh JE, Adeli A (2015a) Computer-aided diagnosis of depression using EEG signals. Euro Neurol 73(5–6):329–336CrossRef
Zurück zum Zitat Acharya UR, Sudarshan VK, Adeli H, Santhosh J, Koh JE, Puthankatti SD, Adeli A (2015b) A novel depression diagnosis index using nonlinear features in EEG signals. Eur Neurol 74(1–2):79–83CrossRefPubMed Acharya UR, Sudarshan VK, Adeli H, Santhosh J, Koh JE, Puthankatti SD, Adeli A (2015b) A novel depression diagnosis index using nonlinear features in EEG signals. Eur Neurol 74(1–2):79–83CrossRefPubMed
Zurück zum Zitat American Psychiatric Association (2013) Diagnostic and statistical manual of mental disorders (DSM-5®): American Psychiatric Association, ArlingtonCrossRef American Psychiatric Association (2013) Diagnostic and statistical manual of mental disorders (DSM-5®): American Psychiatric Association, ArlingtonCrossRef
Zurück zum Zitat Bairy GM, Lih OS, Hagiwara Y, Puthankattil SD, Faust O, Niranjan U, Acharya UR (2017) Automated diagnosis of depression electroencephalograph signals using linear prediction coding and higher order spectra features. J Med Imaging Health Inf 7(8):1857–1862CrossRef Bairy GM, Lih OS, Hagiwara Y, Puthankattil SD, Faust O, Niranjan U, Acharya UR (2017) Automated diagnosis of depression electroencephalograph signals using linear prediction coding and higher order spectra features. J Med Imaging Health Inf 7(8):1857–1862CrossRef
Zurück zum Zitat Berg P, Scherg M (1994) A multiple source approach to the correction of eye artifacts. Electroencephalogr Clin Neurophysiol 90(3):229–241CrossRefPubMed Berg P, Scherg M (1994) A multiple source approach to the correction of eye artifacts. Electroencephalogr Clin Neurophysiol 90(3):229–241CrossRefPubMed
Zurück zum Zitat Boutros NN, Arfken C, Galderisi S, Warrick J, Pratt G, Iacono W (2008) The status of spectral EEG abnormality as a diagnostic test for schizophrenia. Schizophr Res 99(1):225–237CrossRefPubMed Boutros NN, Arfken C, Galderisi S, Warrick J, Pratt G, Iacono W (2008) The status of spectral EEG abnormality as a diagnostic test for schizophrenia. Schizophr Res 99(1):225–237CrossRefPubMed
Zurück zum Zitat Chella F, Pizzella V, Zappasodi F, Marzetti L (2016) Impact of the reference choice on scalp EEG connectivity estimation. J Neural Eng 13(3):036016CrossRefPubMed Chella F, Pizzella V, Zappasodi F, Marzetti L (2016) Impact of the reference choice on scalp EEG connectivity estimation. J Neural Eng 13(3):036016CrossRefPubMed
Zurück zum Zitat Dien J (1998) Issues in the application of the average reference: review, critiques, and recommendations. Behav Res Methods Instrum Comput 30(1):34–43CrossRef Dien J (1998) Issues in the application of the average reference: review, critiques, and recommendations. Behav Res Methods Instrum Comput 30(1):34–43CrossRef
Zurück zum Zitat Dong L, Li F, Liu Q, Wen X, Lai Y, Xu P, Yao D (2017) MATLAB toolboxes for reference electrode standardization technique (REST) of scalp EEG. Front Neurosci 11:601CrossRefPubMedPubMedCentral Dong L, Li F, Liu Q, Wen X, Lai Y, Xu P, Yao D (2017) MATLAB toolboxes for reference electrode standardization technique (REST) of scalp EEG. Front Neurosci 11:601CrossRefPubMedPubMedCentral
Zurück zum Zitat Faust O, Ang PCA, Puthankattil SD, Joseph PK (2014) Depression diagnosis support system based on EEG signal entropies. J Mech Med Biol 14(03):1450035CrossRef Faust O, Ang PCA, Puthankattil SD, Joseph PK (2014) Depression diagnosis support system based on EEG signal entropies. J Mech Med Biol 14(03):1450035CrossRef
Zurück zum Zitat Ferree TC (2006) Spherical splines and average referencing in scalp electroencephalography. Brain Topogr 19(1–2):43–52CrossRefPubMed Ferree TC (2006) Spherical splines and average referencing in scalp electroencephalography. Brain Topogr 19(1–2):43–52CrossRefPubMed
Zurück zum Zitat Fried SJ, Smith DM, Legatt AD (2014) Median nerve somatosensory evoked potential monitoring during carotid endarterectomy: does reference choice matter? J Clin Neurophysiol 31(1):55–57CrossRefPubMed Fried SJ, Smith DM, Legatt AD (2014) Median nerve somatosensory evoked potential monitoring during carotid endarterectomy: does reference choice matter? J Clin Neurophysiol 31(1):55–57CrossRefPubMed
Zurück zum Zitat Hoechstetter K, Berg P, Scherg M (2010). BESA research tutorial 4: distributed source imaging. BESA Res Tutorial, 1–29 Hoechstetter K, Berg P, Scherg M (2010). BESA research tutorial 4: distributed source imaging. BESA Res Tutorial, 1–29
Zurück zum Zitat Hosseinifard B, Moradi MH, Rostami R (2013) Classifying depression patients and normal subjects using machine learning techniques and nonlinear features from EEG signal. Comput Methods Programs Biomed 109(3):339–345CrossRefPubMed Hosseinifard B, Moradi MH, Rostami R (2013) Classifying depression patients and normal subjects using machine learning techniques and nonlinear features from EEG signal. Comput Methods Programs Biomed 109(3):339–345CrossRefPubMed
Zurück zum Zitat Hu S, Lai Y, Valdés-Sosa PA, Brings-Vega ML, Yao D (2017) How do the reference montage and electrodes setup affect the measured scalp EEG potentials? J Neural Eng 15:026013CrossRef Hu S, Lai Y, Valdés-Sosa PA, Brings-Vega ML, Yao D (2017) How do the reference montage and electrodes setup affect the measured scalp EEG potentials? J Neural Eng 15:026013CrossRef
Zurück zum Zitat Jasper HH (1958) The ten twenty electrode system of the international federation. Electroencephalogr Clin Neurophysiol 10:371–375 Jasper HH (1958) The ten twenty electrode system of the international federation. Electroencephalogr Clin Neurophysiol 10:371–375
Zurück zum Zitat Junghöfer M, Elbert T, Tucker DM, Braun C (1999) The polar average reference effect: a bias in estimating the head surface integral in EEG recording. Clin Neurophysiol 110(6):1149–1155CrossRefPubMed Junghöfer M, Elbert T, Tucker DM, Braun C (1999) The polar average reference effect: a bias in estimating the head surface integral in EEG recording. Clin Neurophysiol 110(6):1149–1155CrossRefPubMed
Zurück zum Zitat Jurcak V, Tsuzuki D, Dan I (2007) 10/20, 10/10, and 10/5 systems revisited: their validity as relative head-surface-based positioning systems. Neuroimage 34(4):1600–1611CrossRefPubMed Jurcak V, Tsuzuki D, Dan I (2007) 10/20, 10/10, and 10/5 systems revisited: their validity as relative head-surface-based positioning systems. Neuroimage 34(4):1600–1611CrossRefPubMed
Zurück zum Zitat Knott V, Mahoney C, Kennedy S, Evans K (2001) EEG power, frequency, asymmetry and coherence in male depression. Psychiatry Res 106(2):123–140CrossRefPubMed Knott V, Mahoney C, Kennedy S, Evans K (2001) EEG power, frequency, asymmetry and coherence in male depression. Psychiatry Res 106(2):123–140CrossRefPubMed
Zurück zum Zitat Liao S-C, Wu C-T, Huang H-C, Cheng W-T, Liu Y-H (2017) Major depression detection from EEG signals using kernel eigen-filter-bank common spatial patterns. Sensors 17(6):1385CrossRef Liao S-C, Wu C-T, Huang H-C, Cheng W-T, Liu Y-H (2017) Major depression detection from EEG signals using kernel eigen-filter-bank common spatial patterns. Sensors 17(6):1385CrossRef
Zurück zum Zitat Liu H, Motoda H (2007) Computational methods of feature selection. CRC Press, Boca Raton Liu H, Motoda H (2007) Computational methods of feature selection. CRC Press, Boca Raton
Zurück zum Zitat Liu Q, Balsters JH, Baechinger M, van der Groen O, Wenderoth N, Mantini D (2015) Estimating a neutral reference for electroencephalographic recordings: the importance of using a high-density montage and a realistic head model. J Neural Eng 12(5):056012CrossRefPubMedPubMedCentral Liu Q, Balsters JH, Baechinger M, van der Groen O, Wenderoth N, Mantini D (2015) Estimating a neutral reference for electroencephalographic recordings: the importance of using a high-density montage and a realistic head model. J Neural Eng 12(5):056012CrossRefPubMedPubMedCentral
Zurück zum Zitat Mahmud WMRW., Awang A, Herman I, Mohamed MN (2004) Analysis of the psychometric properties of the Malay version of Beck Depression Inventory II (BDI-II) among postpartum women in Kedah, North West of Peninsular Malaysia. Malays J Med Sci 11(2):19 Mahmud WMRW., Awang A, Herman I, Mohamed MN (2004) Analysis of the psychometric properties of the Malay version of Beck Depression Inventory II (BDI-II) among postpartum women in Kedah, North West of Peninsular Malaysia. Malays J Med Sci 11(2):19
Zurück zum Zitat Mamitsuka H (2006) Selecting features in microarray classification using ROC curves. Pattern Recogn 39(12):2393–2404CrossRef Mamitsuka H (2006) Selecting features in microarray classification using ROC curves. Pattern Recogn 39(12):2393–2404CrossRef
Zurück zum Zitat McLachlan G (2004) Discriminant analysis and statistical pattern recognition, vol 544. Wiley, Hoboken McLachlan G (2004) Discriminant analysis and statistical pattern recognition, vol 544. Wiley, Hoboken
Zurück zum Zitat Mumtaz W, Ali SSA, Yasin MAM, Malik AS (2017a) A machine learning framework involving EEG-based functional connectivity to diagnose major depressive disorder (MDD). Med Biol Eng Comput 56:233–246CrossRefPubMed Mumtaz W, Ali SSA, Yasin MAM, Malik AS (2017a) A machine learning framework involving EEG-based functional connectivity to diagnose major depressive disorder (MDD). Med Biol Eng Comput 56:233–246CrossRefPubMed
Zurück zum Zitat Mumtaz W, Xia L, Ali SSA, Yasin MAM, Hussain M, Malik AS (2017b) Electroencephalogram (EEG)-based computer-aided technique to diagnose major depressive disorder (MDD). Biomed Signal Process Control 31:108–115CrossRef Mumtaz W, Xia L, Ali SSA, Yasin MAM, Hussain M, Malik AS (2017b) Electroencephalogram (EEG)-based computer-aided technique to diagnose major depressive disorder (MDD). Biomed Signal Process Control 31:108–115CrossRef
Zurück zum Zitat Musa R, Fadzil MA, Zain Z (2007) Translation, validation and psychometric properties of Bahasa Malaysia version of the Depression Anxiety and Stress Scales (DASS). ASEAN J Psychiatry 8(2):82–89 Musa R, Fadzil MA, Zain Z (2007) Translation, validation and psychometric properties of Bahasa Malaysia version of the Depression Anxiety and Stress Scales (DASS). ASEAN J Psychiatry 8(2):82–89
Zurück zum Zitat Osselton J (1965) Acquisition of EEG data by bipolar unipolar and average reference methods: a theoretical comparison. Electroencephalogr Clin Neurophysiol 19(5):527–528CrossRefPubMed Osselton J (1965) Acquisition of EEG data by bipolar unipolar and average reference methods: a theoretical comparison. Electroencephalogr Clin Neurophysiol 19(5):527–528CrossRefPubMed
Zurück zum Zitat Puthankattil SD, Joseph PK (2012) Classification of EEG signals in normal and depression conditions by ANN using RWE and signal entropy. J Mech Med Biol 12(04):1240019CrossRef Puthankattil SD, Joseph PK (2012) Classification of EEG signals in normal and depression conditions by ANN using RWE and signal entropy. J Mech Med Biol 12(04):1240019CrossRef
Zurück zum Zitat Qin Y, Xu P, Yao D (2010) A comparative study of different references for EEG default mode network: the use of the infinity reference. Clin Neurophysiol 121(12):1981–1991CrossRefPubMed Qin Y, Xu P, Yao D (2010) A comparative study of different references for EEG default mode network: the use of the infinity reference. Clin Neurophysiol 121(12):1981–1991CrossRefPubMed
Zurück zum Zitat Qin Y, Xin X, Zhu H, Li F, Xiong H, Zhang T, Lai Y (2017) A comparative study on the dynamic EEG center of mass with different references. Front Neurosci 11:509CrossRefPubMedPubMedCentral Qin Y, Xin X, Zhu H, Li F, Xiong H, Zhang T, Lai Y (2017) A comparative study on the dynamic EEG center of mass with different references. Front Neurosci 11:509CrossRefPubMedPubMedCentral
Zurück zum Zitat Stam C, Van Dijk B (2002) Synchronization likelihood: an unbiased measure of generalized synchronization in multivariate data sets. Physica D 163(3):236–251CrossRef Stam C, Van Dijk B (2002) Synchronization likelihood: an unbiased measure of generalized synchronization in multivariate data sets. Physica D 163(3):236–251CrossRef
Zurück zum Zitat Suykens JA, Vandewalle J (1999) Least squares support vector machine classifiers. Neural Process Lett 9(3):293–300CrossRef Suykens JA, Vandewalle J (1999) Least squares support vector machine classifiers. Neural Process Lett 9(3):293–300CrossRef
Zurück zum Zitat Tian Y, Yao D (2013) Why do we need to use a zero reference? Reference influences on the ERPs of audiovisual effects. Psychophysiology 50(12):1282–1290CrossRefPubMed Tian Y, Yao D (2013) Why do we need to use a zero reference? Reference influences on the ERPs of audiovisual effects. Psychophysiology 50(12):1282–1290CrossRefPubMed
Zurück zum Zitat Tiwari AK, Pachori RB, Kanhangad V, Panigrahi BK (2017) Automated diagnosis of epilepsy using key-point-based local binary pattern of EEG signals. IEEE J Biomed Health Inf 21(4):888–896CrossRef Tiwari AK, Pachori RB, Kanhangad V, Panigrahi BK (2017) Automated diagnosis of epilepsy using key-point-based local binary pattern of EEG signals. IEEE J Biomed Health Inf 21(4):888–896CrossRef
Zurück zum Zitat Trujillo LT, Stanfield CT, Vela RD (2017) The effect of electroencephalogram (EEG) reference choice on information-theoretic measures of the complexity and integration of EEG signals. Front Neurosci 11:425CrossRefPubMedPubMedCentral Trujillo LT, Stanfield CT, Vela RD (2017) The effect of electroencephalogram (EEG) reference choice on information-theoretic measures of the complexity and integration of EEG signals. Front Neurosci 11:425CrossRefPubMedPubMedCentral
Zurück zum Zitat Xu P, Xiong XC, Xue Q, Tian Y, Peng Y, Zhang R et al (2014) Recognizing mild cognitive impairment based on network connectivity analysis of resting EEG with zero reference. Physiological measurement 35(7):1279CrossRefPubMed Xu P, Xiong XC, Xue Q, Tian Y, Peng Y, Zhang R et al (2014) Recognizing mild cognitive impairment based on network connectivity analysis of resting EEG with zero reference. Physiological measurement 35(7):1279CrossRefPubMed
Zurück zum Zitat Yang P, Fan C, Wang M, Li L (2017) A comparative study of average, linked mastoid, and REST references for ERP components acquired during fMRI. Front Neurosci 11:247CrossRefPubMedPubMedCentral Yang P, Fan C, Wang M, Li L (2017) A comparative study of average, linked mastoid, and REST references for ERP components acquired during fMRI. Front Neurosci 11:247CrossRefPubMedPubMedCentral
Zurück zum Zitat Yao D (2001) A method to standardize a reference of scalp EEG recordings to a point at infinity. Physiol Meas 22(4):693CrossRefPubMed Yao D (2001) A method to standardize a reference of scalp EEG recordings to a point at infinity. Physiol Meas 22(4):693CrossRefPubMed
Zurück zum Zitat Yao D (2017) Is the surface potential integral of a dipole in a volume conductor always zero? A cloud over the average reference of EEG and ERP. Brain Topogr 30(2):161–171CrossRefPubMedPubMedCentral Yao D (2017) Is the surface potential integral of a dipole in a volume conductor always zero? A cloud over the average reference of EEG and ERP. Brain Topogr 30(2):161–171CrossRefPubMedPubMedCentral
Zurück zum Zitat Yao D, Wang L, Oostenveld R, Nielsen KD, Arendt-Nielsen L, Chen AC (2005) A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference. Physiol Meas 26(3):173CrossRefPubMed Yao D, Wang L, Oostenveld R, Nielsen KD, Arendt-Nielsen L, Chen AC (2005) A comparative study of different references for EEG spectral mapping: the issue of the neutral reference and the use of the infinity reference. Physiol Meas 26(3):173CrossRefPubMed
Metadaten
Titel
A Comparative Study of Different EEG Reference Choices for Diagnosing Unipolar Depression
verfasst von
Wajid Mumtaz
Aamir Saeed Malik
Publikationsdatum
02.06.2018
Verlag
Springer US
Erschienen in
Brain Topography / Ausgabe 5/2018
Print ISSN: 0896-0267
Elektronische ISSN: 1573-6792
DOI
https://doi.org/10.1007/s10548-018-0651-x

Weitere Artikel der Ausgabe 5/2018

Brain Topography 5/2018 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.