Skip to main content
Erschienen in: Breast Cancer Research and Treatment 2/2012

01.11.2012 | Clinical Trial

Efficacy of ‘radioguided occult lesion localisation’ (ROLL) versus ‘wire-guided localisation’ (WGL) in breast conserving surgery for non-palpable breast cancer: a randomised controlled multicentre trial

verfasst von: E. L. Postma, H. M. Verkooijen, S. van Esser, M. G. Hobbelink, G. P. van der Schelling, R. Koelemij, A. J. Witkamp, C. Contant, P. J. van Diest, S. M. Willems, I. H. M. Borel Rinkes, M. A. A. J. van den Bosch, W. P. Mali, R. van Hillegersberg, the ROLL study group

Erschienen in: Breast Cancer Research and Treatment | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

For the management of non-palpable breast cancer, accurate pre-operative localisation is essential to achieve complete resection with optimal cosmetic results. Radioguided occult lesions localisation (ROLL) uses the radiotracer, injected intra-tumourally for sentinel lymph node identification to guide surgical excision of the primary tumour. In a multicentre randomised controlled trial, we determined if ROLL is superior to the standard of care (i.e. wire-guided localisation, WGL) for preoperative tumour localisation. Women (>18 years.) with histologically proven non-palpable breast cancer and eligible for breast conserving treatment with sentinel node procedure were randomised to ROLL or WGL. Patients allocated to ROLL received an intra-tumoural dose of 120 Mbq technetium-99 m nanocolloid. The tumour was surgically removed, guided by gamma probe detection. In the WGL group, ultrasound- or mammography-guided insertion of a hooked wire provided surgical guidance for excision of the primary tumour. Primary outcome measures were the proportion of complete tumour excisions (i.e. with negative margins), the proportion of patients requiring re-excision and the volume of tissue removed. Data were analysed according to intention-to-treat principle. This study is registered at ClinincalTrials.gov, number NCT00539474. In total, 314 patients with 316 invasive breast cancers were enrolled. Complete tumour removal with negative margins was achieved in 140/162 (86 %) patients in the ROLL group versus 134/152 (88 %) patients in the WGL group (P = 0.644). Re-excision was required in 19/162 (12 %) patients in the ROLL group versus 15/152 (10 %) (P = 0.587) in the WGL group. Specimen volumes in the ROLL arm were significantly larger than those in the WGL arm (71 vs. 64 cm3, P = 0.017). No significant differences were seen in the duration and difficulty of the radiological and surgical procedures, the success rate of the sentinel node procedure, and cosmetic outcomes. In this first multicentre randomised controlled comparison of ROLL versus WGL in patients with histologically proven breast cancer, ROLL is comparable to WGL in terms of complete tumour excision and re-excision rates. ROLL, however, leads to excision of larger tissue volumes. Therefore, ROLL cannot replace WGL as the standard of care.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Dodd GD, Fry K, Delany W (1965) Pre-operative localization of occult carcinoma of the breast. In: Nealon TF (ed) Management of the Patient with Breast Cancer. WB Saunders, Philadelphia, pp 88–113 Dodd GD, Fry K, Delany W (1965) Pre-operative localization of occult carcinoma of the breast. In: Nealon TF (ed) Management of the Patient with Breast Cancer. WB Saunders, Philadelphia, pp 88–113
4.
Zurück zum Zitat Burkholder HC, Witherspoon LE, Burns RP et al (2007) Breast surgery techniques: preoperative bracketing wire localization by surgeons. Am Surg 73:574–578 discussion 578–9PubMed Burkholder HC, Witherspoon LE, Burns RP et al (2007) Breast surgery techniques: preoperative bracketing wire localization by surgeons. Am Surg 73:574–578 discussion 578–9PubMed
8.
Zurück zum Zitat Helvie MA, Ikeda DM, Adler DD (1991) Localization and needle aspiration of breast lesions: complications in 370 cases. Am J Roentgenol 157:711–714 Helvie MA, Ikeda DM, Adler DD (1991) Localization and needle aspiration of breast lesions: complications in 370 cases. Am J Roentgenol 157:711–714
10.
Zurück zum Zitat Chadwick DR, Shorthouse AJ (1997) Wire-directed localization biopsy of the breast: an audit of results and analysis of factors influencing therapeutic value in the treatment of breast cancer. Eur J Surg Oncol 23:128–133PubMedCrossRef Chadwick DR, Shorthouse AJ (1997) Wire-directed localization biopsy of the breast: an audit of results and analysis of factors influencing therapeutic value in the treatment of breast cancer. Eur J Surg Oncol 23:128–133PubMedCrossRef
12.
Zurück zum Zitat Luini A, Zurrida S, Galimberti V et al (1998) Radioguided surgery of occult breast lesions. Eur J Cancer 34:204–205PubMedCrossRef Luini A, Zurrida S, Galimberti V et al (1998) Radioguided surgery of occult breast lesions. Eur J Cancer 34:204–205PubMedCrossRef
14.
Zurück zum Zitat Lovrics P, Cornacchi S, Vora R et al (2010) Systematic review of radio-guided surgery for nonpalpable breast cancer. Ann Surg Oncol 17:S181 Lovrics P, Cornacchi S, Vora R et al (2010) Systematic review of radio-guided surgery for nonpalpable breast cancer. Ann Surg Oncol 17:S181
15.
Zurück zum Zitat van Esser S, Hobbelink MG, Peeters PH et al (2008) The efficacy of ‘radio guided occult lesion localization’ (ROLL) versus ‘wire-guided localization’ (WGL) in breast conserving surgery for non-palpable breast cancer: a randomized clinical trial–ROLL study. BMC Surg 8:9. doi:10.1186/1471-2482-8-9 PubMedCrossRef van Esser S, Hobbelink MG, Peeters PH et al (2008) The efficacy of ‘radio guided occult lesion localization’ (ROLL) versus ‘wire-guided localization’ (WGL) in breast conserving surgery for non-palpable breast cancer: a randomized clinical trial–ROLL study. BMC Surg 8:9. doi:10.​1186/​1471-2482-8-9 PubMedCrossRef
16.
Zurück zum Zitat Wapnir IL, Wartenberg DE, Greco RS (1996) Three dimensional staging of breast cancer. Breast Cancer Res Treat 41:15–19PubMedCrossRef Wapnir IL, Wartenberg DE, Greco RS (1996) Three dimensional staging of breast cancer. Breast Cancer Res Treat 41:15–19PubMedCrossRef
17.
Zurück zum Zitat Dindo D, Demartines N, Clavien PA (2004) Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 240:205–213PubMedCrossRef Dindo D, Demartines N, Clavien PA (2004) Classification of surgical complications: a new proposal with evaluation in a cohort of 6336 patients and results of a survey. Ann Surg 240:205–213PubMedCrossRef
20.
21.
Zurück zum Zitat Mariscal Martinez A, Sola M, Perez De Tudela A et al (2009) Radioguided localization of nonpalpable breast cancer lesions: randomized comparison with wire localization in patients undergoing conservative surgery and sentinel node biopsy. Am J Roentgenol 193:1001–1009CrossRef Mariscal Martinez A, Sola M, Perez De Tudela A et al (2009) Radioguided localization of nonpalpable breast cancer lesions: randomized comparison with wire localization in patients undergoing conservative surgery and sentinel node biopsy. Am J Roentgenol 193:1001–1009CrossRef
22.
Zurück zum Zitat Medina-Franco H, Abarca-Perez L, Garcia-Alvarez MN et al (2008) Radioguided occult lesion localization (ROLL) versus wire-guided lumpectomy for non-palpable breast lesions: a randomized prospective evaluation. J Surg Oncol 97:108–111. doi:10.1002/jso.20880 PubMedCrossRef Medina-Franco H, Abarca-Perez L, Garcia-Alvarez MN et al (2008) Radioguided occult lesion localization (ROLL) versus wire-guided lumpectomy for non-palpable breast lesions: a randomized prospective evaluation. J Surg Oncol 97:108–111. doi:10.​1002/​jso.​20880 PubMedCrossRef
24.
Zurück zum Zitat Ocal K, Dag A, Turkmenoglu O et al (2011) Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial. Clinics (Sao Paulo) 66:1003–1007CrossRef Ocal K, Dag A, Turkmenoglu O et al (2011) Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial. Clinics (Sao Paulo) 66:1003–1007CrossRef
25.
Zurück zum Zitat Graham RA, Homer MJ, Katz J et al (2002) The pancake phenomenon contributes to the inaccuracy of margin assessment in patients with breast cancer. Am J Surg 184:89–93PubMedCrossRef Graham RA, Homer MJ, Katz J et al (2002) The pancake phenomenon contributes to the inaccuracy of margin assessment in patients with breast cancer. Am J Surg 184:89–93PubMedCrossRef
29.
Zurück zum Zitat Lovrics PJ, Goldsmith CH, Hodgson N et al (2011) A multicentered, randomized, controlled trial comparing radioguided seed localization to standard wire localization for nonpalpable, invasive and in situ breast carcinomas. Ann Surg Oncol 18:3407–3414. doi:10.1245/s10434-011-1699-y PubMedCrossRef Lovrics PJ, Goldsmith CH, Hodgson N et al (2011) A multicentered, randomized, controlled trial comparing radioguided seed localization to standard wire localization for nonpalpable, invasive and in situ breast carcinomas. Ann Surg Oncol 18:3407–3414. doi:10.​1245/​s10434-011-1699-y PubMedCrossRef
Metadaten
Titel
Efficacy of ‘radioguided occult lesion localisation’ (ROLL) versus ‘wire-guided localisation’ (WGL) in breast conserving surgery for non-palpable breast cancer: a randomised controlled multicentre trial
verfasst von
E. L. Postma
H. M. Verkooijen
S. van Esser
M. G. Hobbelink
G. P. van der Schelling
R. Koelemij
A. J. Witkamp
C. Contant
P. J. van Diest
S. M. Willems
I. H. M. Borel Rinkes
M. A. A. J. van den Bosch
W. P. Mali
R. van Hillegersberg
the ROLL study group
Publikationsdatum
01.11.2012
Verlag
Springer US
Erschienen in
Breast Cancer Research and Treatment / Ausgabe 2/2012
Print ISSN: 0167-6806
Elektronische ISSN: 1573-7217
DOI
https://doi.org/10.1007/s10549-012-2225-z

Weitere Artikel der Ausgabe 2/2012

Breast Cancer Research and Treatment 2/2012 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.