Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 6/2013

01.08.2013 | Original Paper

Shortened acquisition time or reduced-activity dose for gated myocardial perfusion SPECT with new reconstruction algorithm

verfasst von: Xiao-Xin Sun, Yue-Qin Tian, Dao-Yu Wang, Zuo-Xiang He

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 6/2013

Einloggen, um Zugang zu erhalten

Abstract

To confirm that shortened acquisition time or reduced-activity dose in single-photon emission computed tomography (SPECT) myocardial perfusion imaging reconstructed with Astonish software (AS) does not compromise image quality or diagnostic accuracy. One hundred patients referred for SPECT myocardial perfusion imaging were prospectively studied. The patients were randomly selected to receive the full-dose protocol (group A, n = 54) or the half-dose protocol (group B, n = 46). The patients of group A underwent a 2-day stress/rest protocol. After half-time acquisition, they underwent a full-time acquisition for stress and rest SPECT. Group B underwent a 1-day stress/rest protocol. During peak stress, all patients received an intravenous injection of 99mTc-methoxyisobutylisonitrile (MIBI; 5.2 ± 0.6 mCi). After the full-time stress acquisition, the patients underwent a double-time stress acquisition. If the stress image showed a defect, a patient received 99mTc-MIBI (19.5 ± 1.7 mCi) at rest on the same day. The rest SPECT acquisition protocol was the same in both groups. The low count (LC) and high count (HC) were acquired for each patient. AS and filtered back projection (FBP) reconstructed each set of raw data. Image quality of perfusion was assessed on a four-point scale. Perfusion parameters and function parameters were calculated by quantitative perfusion SPECT and quantitative gated SPECT. Mean image quality for LC-AS and HC-AS (3.5 ± 0.5 and 3.7 ± 0.5, respectively) was superior to HC-FBP (3.1 ± 0.4) in group A (for all, p < 0.001). LC-AS and HC-AS (3.5 ± 0.5 and 3.6 ± 0.5, respectively) in group B were superior to HC-FBP (3.1 ± 0.3) (for all, p < 0.001). LC-AS, HC-AS and LC-FBP showed high diagnostic concordance with HC-FBP (kappa value was 0.92, 0.92, and 0.94, respectively; all p < 0.001). Cardiac SPECT studies can be acquired with half of the scan time or reduced radioactivity dose and reconstructed by using the AS algorithm without compromising image quality.
Literatur
1.
Zurück zum Zitat Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1:156–163PubMedCrossRef Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Berman DS (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1:156–163PubMedCrossRef
2.
Zurück zum Zitat Duvall WL, Sweeny JM, Croft LB, Ginsberg E, Guma KA, Henzlova MJ (2012) Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography. J Nucl Cardiol 19:19–27PubMedCrossRef Duvall WL, Sweeny JM, Croft LB, Ginsberg E, Guma KA, Henzlova MJ (2012) Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: comparison to coronary angiography. J Nucl Cardiol 19:19–27PubMedCrossRef
3.
Zurück zum Zitat Gimelli A, Bottai M, Genovesi D, Giorgetti A, Di Martino F, Marzullo P (2012) High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results. Eur J Nucl Med Mol Imaging 39:83–90PubMedCrossRef Gimelli A, Bottai M, Genovesi D, Giorgetti A, Di Martino F, Marzullo P (2012) High diagnostic accuracy of low-dose gated-SPECT with solid-state ultrafast detectors: preliminary clinical results. Eur J Nucl Med Mol Imaging 39:83–90PubMedCrossRef
4.
Zurück zum Zitat Nkoulou R, Pazhenkottil AP, Kuest SM, Ghadri JR, Wolfrum M, Husmann L et al (2011) Semiconductor detectors allow low-dose-low-dose 1-day SPECT myocardial perfusion imaging. J Nucl Med 52:1204–1209PubMedCrossRef Nkoulou R, Pazhenkottil AP, Kuest SM, Ghadri JR, Wolfrum M, Husmann L et al (2011) Semiconductor detectors allow low-dose-low-dose 1-day SPECT myocardial perfusion imaging. J Nucl Med 52:1204–1209PubMedCrossRef
5.
Zurück zum Zitat Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, Adams GL et al (2007) Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol 14:555–565PubMedCrossRef Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, Adams GL et al (2007) Clinical results of a novel wide beam reconstruction method for shortening scan time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol 14:555–565PubMedCrossRef
6.
Zurück zum Zitat DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC (2008) Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” filtered backprojection. J Nucl Cardiol 15:547–563PubMedCrossRef DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC (2008) Ordered subset expectation maximization and wide beam reconstruction “half-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” filtered backprojection. J Nucl Cardiol 15:547–563PubMedCrossRef
7.
Zurück zum Zitat Han PP, Tian YQ, Fang W, Yang MF, Zhang XL, Shen R et al (2011) Impact of myocardial perfusion imaging on in-hospital coronary angiography and revascularization of patients with suspected coronary artery disease. Chin Med J (Engl) 124:1603–1609 Han PP, Tian YQ, Fang W, Yang MF, Zhang XL, Shen R et al (2011) Impact of myocardial perfusion imaging on in-hospital coronary angiography and revascularization of patients with suspected coronary artery disease. Chin Med J (Engl) 124:1603–1609
8.
Zurück zum Zitat Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542PubMedCrossRef Cerqueira MD, Weissman NJ, Dilsizian V, Jacobs AK, Kaul S, Laskey WK et al (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542PubMedCrossRef
9.
Zurück zum Zitat Germano G, Kavanagh PB, Waechter P, Areeda J, Van Kriekinge S, Sharir T et al (2000) A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility. J Nucl Med 41:712–719PubMed Germano G, Kavanagh PB, Waechter P, Areeda J, Van Kriekinge S, Sharir T et al (2000) A new algorithm for the quantitation of myocardial perfusion SPECT. I: technical principles and reproducibility. J Nucl Med 41:712–719PubMed
10.
Zurück zum Zitat Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB et al (2007) Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol 14:e39–e60PubMedCrossRef Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB et al (2007) Myocardial perfusion and function: single photon emission computed tomography. J Nucl Cardiol 14:e39–e60PubMedCrossRef
11.
Zurück zum Zitat Venero CV, Heller GV, Bateman TM, McGhie AI, Ahlberg AW, Katten D et al (2009) A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction. J Nucl Cardiol 16:714–725PubMedCrossRef Venero CV, Heller GV, Bateman TM, McGhie AI, Ahlberg AW, Katten D et al (2009) A multicenter evaluation of a new post-processing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction. J Nucl Cardiol 16:714–725PubMedCrossRef
12.
Zurück zum Zitat Maddahi J, Mendez R, Mahmarian JJ, Thomas G, Babla H, Bai C et al (2009) Prospective multicenter evaluation of rapid, gated SPECT myocardial perfusion upright imaging. J Nucl Cardiol 16:351–357PubMedCrossRef Maddahi J, Mendez R, Mahmarian JJ, Thomas G, Babla H, Bai C et al (2009) Prospective multicenter evaluation of rapid, gated SPECT myocardial perfusion upright imaging. J Nucl Cardiol 16:351–357PubMedCrossRef
13.
Zurück zum Zitat DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y (2009) Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximum. J Nucl Cardiol 16:736–752PubMedCrossRef DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y (2009) Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison to “full-time” ordered subset expectation maximum. J Nucl Cardiol 16:736–752PubMedCrossRef
14.
Zurück zum Zitat DePuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M (2011) A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol 18:273–280PubMedCrossRef DePuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M (2011) A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol 18:273–280PubMedCrossRef
15.
Zurück zum Zitat Basso D, Passmore G, Holman M, Rogers W, Walters L, Zecchin T et al (2009) Semiqualitative visual and quantitative morphometric evaluations of reduced scan time and wide-beam reconstruction in rest-gated stress SPECT myocardial perfusion imaging. J Nucl Med Technol 37:233–239PubMedCrossRef Basso D, Passmore G, Holman M, Rogers W, Walters L, Zecchin T et al (2009) Semiqualitative visual and quantitative morphometric evaluations of reduced scan time and wide-beam reconstruction in rest-gated stress SPECT myocardial perfusion imaging. J Nucl Med Technol 37:233–239PubMedCrossRef
16.
Zurück zum Zitat Berrington de Gonzalez A, Kim KP, Smith-Bindman R, McAreavey D (2010) Myocardial perfusion scans: projected population cancer risks from current levels of use in the United States. Circulation 122:2403–2410PubMedCrossRef Berrington de Gonzalez A, Kim KP, Smith-Bindman R, McAreavey D (2010) Myocardial perfusion scans: projected population cancer risks from current levels of use in the United States. Circulation 122:2403–2410PubMedCrossRef
17.
Zurück zum Zitat Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361:849–857PubMedCrossRef Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med 361:849–857PubMedCrossRef
18.
Zurück zum Zitat Schroeder-Tanka JM, Tiel-van Buul MM, van der Wall EE, Roolker W, Lie KI, van Royen EA (1997) Should imaging at stress always be followed by imaging at rest in Tc-99 m MIBI SPECT? A proposal for a selective referral and imaging strategy. Int J Card Imaging 13:323–329PubMedCrossRef Schroeder-Tanka JM, Tiel-van Buul MM, van der Wall EE, Roolker W, Lie KI, van Royen EA (1997) Should imaging at stress always be followed by imaging at rest in Tc-99 m MIBI SPECT? A proposal for a selective referral and imaging strategy. Int J Card Imaging 13:323–329PubMedCrossRef
Metadaten
Titel
Shortened acquisition time or reduced-activity dose for gated myocardial perfusion SPECT with new reconstruction algorithm
verfasst von
Xiao-Xin Sun
Yue-Qin Tian
Dao-Yu Wang
Zuo-Xiang He
Publikationsdatum
01.08.2013
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 6/2013
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-013-0205-y

Weitere Artikel der Ausgabe 6/2013

The International Journal of Cardiovascular Imaging 6/2013 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.