Skip to main content

Advertisement

Log in

Prognostic value of dual-source multidetector computed tomography coronary angiography in patients with stent implantation

  • Original Paper
  • Published:
The International Journal of Cardiovascular Imaging Aims and scope Submit manuscript

Abstract

We aim to evaluate the prognostic value of dual-source 64-slice multidetector computed tomography (MDCT) in patients with coronary stents. The study included 173 patients [mean age 59.9 ± 10.1 years, 76.7 % male] with previous stent implantation who underwent MDCT for evaluation of CAD and stent patency. Coronary imaging was performed via dual-source MDCT scanner. Stented vessel segment was evaluated as patent without neointimal hyperplasia (NIH), nonobstructive NIH (<50 % luminal narrowing), or obstructive NIH (>50 % luminal narrowing). Patients were evaluated for major cardiovascular events (MACEs) to demonstrate association between stent patency and clinical outcome. MACEs that were originating from non-stented segments were excluded. A total of 213 coronary stents were evaluated in our study. During mean of 21.2 ± 13.6 months’ follow-up, 25 patients experienced MACEs [1 (4.0 %) cardiac death, 5 (20.0 %) nonfatal MI, and 19 (76.0 %) unstable angina pectoris requiring hospitalization and target vessel revascularization] associated with stented segment of coronary arteries. One hundred of 105 patients (95.2 %) with a patent stent without NIH detected by MDCT had no cardiac event associated with stented segments during mean 2 years’ follow-up period. These data indicate that patients with a patent stent without NIH as determined by MDCT have a good prognosis as opposed to an increased rate of events among patients with either nonobstructive or obstructive NIH as determined with MDCT, supporting MDCT as a reliable tool to evaluate patients after coronary stenting.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. de Graaf FR, Schuijf JD, van Velzen JE, Boogers MJ, Kroft LJ, de Roos A, Reiber JH, Sieders A, Spano F, Jukema JW, Schalij MJ, van der Wall EE, Bax JJ (2010) Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography to noninvasively assess in-stent restenosis. Invest Radiol 45(6):331–340. doi:10.1097/RLI.0b013e3181dfa312

    PubMed  Google Scholar 

  2. Yorgun H, Hazirolan T, Kaya EB, Gurses KM, Evranos B, Canpolat U, Karcaaltincaba M, Ates AH, Aytemir K, Tokgozoglu L, Kabakci G, Oto A (2010) The prevalence of coronary artery anomalies in patients undergoing multidetector computed tomography for the evaluation of coronary artery disease. Turk Kardiyol Dern Ars 38(5):341–348

    PubMed  Google Scholar 

  3. Otero HJ, Steigner ML, Rybicki FJ (2009) The “post-64” era of coronary CT angiography: understanding new technology from physical principles. Radiol Clin North Am 47(1):79–90. doi:10.1016/j.rcl.2008.11.001

    Article  PubMed  Google Scholar 

  4. Sunman H, Yorgun H, Canpolat U, Hazirolan T, Kaya EB, Ates AH, Dural M, Aytemir K, Tokgozoglu L, Kabakci G, Akata D, Oto A (2011) Association between family history of premature coronary artery disease and coronary atherosclerotic plaques shown by multidetector computed tomography coronary angiography. Int J Cardiol. doi:10.1016/j.ijcard.2011.07.043

    Google Scholar 

  5. Andreini D, Pontone G, Mushtaq S, Pepi M, Bartorelli AL (2010) Multidetector computed tomography coronary angiography for the assessment of coronary in-stent restenosis. Am J Cardiol 105(5):645–655. doi:10.1016/j.amjcard.2009.10.046

    Article  PubMed  Google Scholar 

  6. Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL Jr, Jones DW, Materson BJ, Oparil S, Wright JT Jr, Roccella EJ (2003) Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. Hypertension 42(6):1206–1252. doi:10.1161/01.HYP.0000107251.49515.c2

    Article  PubMed  CAS  Google Scholar 

  7. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, McGoon DC, Murphy ML, Roe BB (1975) A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 51(4 Suppl):5–40

    Article  PubMed  CAS  Google Scholar 

  8. Thygesen K, Alpert JS, White HD (2007) Universal definition of myocardial infarction. Eur Heart J 28(20):2525–2538. doi:10.1093/eurheartj/ehm355

    Article  PubMed  Google Scholar 

  9. Budoff MJ, Achenbach S, Blumenthal RS, Carr JJ, Goldin JG, Greenland P, Guerci AD, Lima JA, Rader DJ, Rubin GD, Shaw LJ, Wiegers SE (2006) Assessment of coronary artery disease by cardiac computed tomography: a scientific statement from the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging Council on Clinical Cardiology. Circulation 114(16):1761–1791. doi:10.1161/CIRCULATIONAHA.106.178458

    Article  PubMed  Google Scholar 

  10. Schuijf JD, Bax JJ, Jukema JW, Lamb HJ, Warda HM, Vliegen HW, de Roos A, van der Wall EE (2004) Feasibility of assessment of coronary stent patency using 16-slice computed tomography. Am J Cardiol 94(4):427–430. doi:10.1016/j.amjcard.2004.04.057

    Article  PubMed  Google Scholar 

  11. Pump H, Mohlenkamp S, Sehnert CA, Schimpf SS, Schmidt A, Erbel R, Gronemeyer DH, Seibel RM (2000) Coronary arterial stent patency: assessment with electron-beam CT. Radiology 214(2):447–452

    PubMed  CAS  Google Scholar 

  12. Andreini D, Pontone G, Bartorelli AL, Mushtaq S, Trabattoni D, Bertella E, Cortinovis S, Annoni A, Formenti A, Ballerini G, Agostoni P, Fiorentini C, Pepi M (2011) High diagnostic accuracy of prospective ECG-gating 64-slice computed tomography coronary angiography for the detection of in-stent restenosis: in-stent restenosis assessment by low-dose MDCT. Eur Radiol 21(7):1430–1438. doi:10.1007/s00330-011-2085-7

    Article  PubMed  Google Scholar 

  13. Oncel D, Oncel G, Karaca M (2007) Coronary stent patency and in-stent restenosis: determination with 64-section multidetector CT coronary angiography–initial experience. Radiology 242(2):403–409. doi:10.1148/radiol.2422060065

    Article  PubMed  Google Scholar 

  14. Vanhoenacker PK, Decramer I, Bladt O, Sarno G, Van Hul E, Wijns W, Dwamena BA (2008) Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance. BMC Med Imaging 8:14. doi:10.1186/1471-2342-8-14

    Article  PubMed  Google Scholar 

  15. Martuscelli E, Romagnoli A, D’Eliseo A, Sperandio M, Di Luozzo M, De Angelis B, Romeo F, Simonetti G (2010) Evaluation of coronary in-stent restenosis by 64-slice computed tomography in patients with optimal heart rate control by systematic administration of beta-blocker drugs. J Cardiovasc Med (Hagerstown) 11(6):431–439. doi:10.2459/JCM.0b013e3283330fcd

    Article  Google Scholar 

  16. Carbone I, Francone M, Algeri E, Granatelli A, Napoli A, Kirchin MA, Catalano C, Passariello R (2008) Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography. Eur Radiol 18(2):234–243. doi:10.1007/s00330-007-0756-1

    Article  PubMed  Google Scholar 

  17. Cademartiri F, Schuijf JD, Pugliese F, Mollet NR, Jukema JW, Maffei E, Kroft LJ, Palumbo A, Ardissino D, Serruys PW, Krestin GP, Van der Wall EE, de Feyter PJ, Bax JJ (2007) Usefulness of 64-slice multislice computed tomography coronary angiography to assess in-stent restenosis. J Am Coll Cardiol 49(22):2204–2210. doi:10.1016/j.jacc.2007.02.045

    Article  PubMed  Google Scholar 

  18. Steigner ML, Mitsouras D, Whitmore AG, Otero HJ, Wang C, Buckley O, Levit NA, Hussain AZ, Cai T, Mather RT, Smedby O, DiCarli MF, Rybicki FJ (2010) Iodinated contrast opacification gradients in normal coronary arteries imaged with prospectively ECG-gated single heart beat 320-detector row computed tomography. Circ Cardiovasc Imaging 3(2):179–186. doi:10.1161/CIRCIMAGING.109.854307

    Article  PubMed  Google Scholar 

  19. Wong DT, Ko BS, Cameron JD, Nerlekar N, Leung MC, Malaiapan Y, Crossett M, Leong DP, Worthley SG, Troupis J, Meredith IT, Seneviratne SK (2013) Transluminal attenuation gradient in coronary computed tomography angiography is a novel noninvasive approach to the identification of functionally significant coronary artery stenosis: a comparison with fractional flow reserve. J Am Coll Cardiol 61(12):1271–1279. doi:10.1016/j.jacc.2012.12.029

    Article  PubMed  Google Scholar 

  20. Ding J, Li M, Sun G, Andreini D, Pontone G, Mushtaq S, Bartorelli AL, Pepi M (2013) Accuracy of New CT Scanner in the Diagnosis of Coronary In-Stent Restenosis. Radiology 267(1):315–316. doi:10.1148/radiol.13122368

    Article  PubMed  Google Scholar 

  21. Grewe PH, Deneke T, Machraoui A, Barmeyer J, Muller KM (2000) Acute and chronic tissue response to coronary stent implantation: pathologic findings in human specimen. J Am Coll Cardiol 35(1):157–163

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgments

The authors would like to acknowledge and thank Mr Hakan Cakir, for their expert statistical advice during the revision phase of the current manuscript.

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hamza Sunman.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sunman, H., Yorgun, H., Canpolat, U. et al. Prognostic value of dual-source multidetector computed tomography coronary angiography in patients with stent implantation. Int J Cardiovasc Imaging 29, 1603–1611 (2013). https://doi.org/10.1007/s10554-013-0236-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10554-013-0236-4

Keywords

Navigation