Abstract

Validation of a new single breath-hold, three-dimensional, cine balanced steady-state free precession (3D cine bSSFP) cardiac magnetic resonance (CMR) sequence for left ventricular function. CMR examinations were performed on fifteen patients and three healthy volunteers on a clinical 1.5T scanner using a two-dimensional (2D) cine balanced SSFP CMR sequence (2D cine bSSFP) followed by an investigational 3D cine bSSFP pulse sequence acquired within a single breath hold. Left ventricular end diastolic volume (LVEDV), end systolic volume (LVESV), ejection fraction (LVEF), and myocardial mass were independently segmented on a workstation by two experienced radiologists. Blood pool to myocardial contrast was evaluated in consensus using a Likert scale. Bland–Altman analysis was used to compare these quantitative and nominal measurements for the two sequences. The average acquisition time was significantly shorter for the 3D cine bSSFP than for 2D cine bSSFP (0.36 ± 0.03 vs. 8.5 ± 2.3 min) p = 0.0002. Bland–Altman analyses [bias and (limits of agreement)] of the data derived from these two methods revealed that the LVEF 0.9 % (−4.7, 6.4), LVEDV 4.9 ml (−23.0, 32.8), LVESV −0.2 ml (−22.4, 21.9), and myocardial mass −0.4 g (−23.8, 23.0) were not significantly different. There was excellent intraclass correlation for intra-observer variability (0.981, 0.989, 0.997, 0.985) and inter-observer variability (0.903, 0.954, 0.970, 0.842) for LVEF, LVEDV, LVESV, and myocardial mass respectively. 3D cine bSSFP allows for accurate single breath-hold volumetric cine CMR which enables substantial improvements in scanner time efficiency without sacrificing diagnostic accuracy.
Literatur
1.
Zurück zum Zitat Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219(3):828–834CrossRefPubMed Carr JC, Simonetti O, Bundy J, Li D, Pereles S, Finn JP (2001) Cine MR angiography of the heart with segmented true fast imaging with steady-state precession. Radiology 219(3):828–834CrossRefPubMed
2.
Zurück zum Zitat Makowski MR, Wiethoff AJ, Jansen CH, Uribe S, Parish V, Schuster A, Botnar RM, Bell A, Kiesewetter C, Razavi R, Schaeffter T, Greil GF (2012) Single breath-hold assessment of cardiac function using an accelerated 3D single breath hold acquisition technique—comparison of an intravascular and extravascular contrast agent. J Cardiovasc Magn Reson 31(14):53CrossRef Makowski MR, Wiethoff AJ, Jansen CH, Uribe S, Parish V, Schuster A, Botnar RM, Bell A, Kiesewetter C, Razavi R, Schaeffter T, Greil GF (2012) Single breath-hold assessment of cardiac function using an accelerated 3D single breath hold acquisition technique—comparison of an intravascular and extravascular contrast agent. J Cardiovasc Magn Reson 31(14):53CrossRef
3.
Zurück zum Zitat Liu J, Spincemaille P, Codella NC, Nguyen TD, Prince MR, Wang Y (2010) Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med 63(5):1230–1237CrossRefPubMedCentralPubMed Liu J, Spincemaille P, Codella NC, Nguyen TD, Prince MR, Wang Y (2010) Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med 63(5):1230–1237CrossRefPubMedCentralPubMed
4.
Zurück zum Zitat Lai P, Brau AC, Beatty P, Shankaranarayanan A (2009) Highly-accelerated cardiac cine MR imaging using kat ARC. In: ISMRM 2009, Abstract 766 Lai P, Brau AC, Beatty P, Shankaranarayanan A (2009) Highly-accelerated cardiac cine MR imaging using kat ARC. In: ISMRM 2009, Abstract 766
5.
Zurück zum Zitat Lai P, Fung MM, Vasanawala SS, Brau AC (2012) Single breathhold three-dimensional cardiac cine MRI with whole ventricular coverage and retrospective cardiac gating using kat ARC. J Cardiovasc Magn Reson 14(Suppl 1):W69CrossRefPubMedCentral Lai P, Fung MM, Vasanawala SS, Brau AC (2012) Single breathhold three-dimensional cardiac cine MRI with whole ventricular coverage and retrospective cardiac gating using kat ARC. J Cardiovasc Magn Reson 14(Suppl 1):W69CrossRefPubMedCentral
6.
Zurück zum Zitat Kozerke S, Tsao J, Razavi R, Boesiger P (2004) Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med 52(1):19–26CrossRefPubMed Kozerke S, Tsao J, Razavi R, Boesiger P (2004) Accelerating cardiac cine 3D imaging using k-t BLAST. Magn Reson Med 52(1):19–26CrossRefPubMed
7.
Zurück zum Zitat Lai P, Alley MT, Vasanawala SS, Brau AC (2011) Single-breathhold three-dimensional cardiac cine mri with retrospective cardiac gating using high acceleration kat arc (k- and adaptive t-autocalibrating reconstruction for cartesian sampling. In: ISMRM 2011. Abstract 3378 Lai P, Alley MT, Vasanawala SS, Brau AC (2011) Single-breathhold three-dimensional cardiac cine mri with retrospective cardiac gating using high acceleration kat arc (k- and adaptive t-autocalibrating reconstruction for cartesian sampling. In: ISMRM 2011. Abstract 3378
8.
Zurück zum Zitat Lai P, Vasanawala S, Brau AC (2014) Toward robust clinically-practical single-breathhold 3D cardiac cine MRI with high acceleration and rapid online reconstruction. In: ISMRM 2014. Abstract 4379 Lai P, Vasanawala S, Brau AC (2014) Toward robust clinically-practical single-breathhold 3D cardiac cine MRI with high acceleration and rapid online reconstruction. In: ISMRM 2014. Abstract 4379
9.
Zurück zum Zitat Lai P, Vasanawala S, Nozaki A et al (2013) Improving k-t auto-calibrating parallel imaging for 3D cardiac cine MRI using prior-reconstruction static tissue estimation and elimination. In: ISMRM 2013. Abstract 128 Lai P, Vasanawala S, Nozaki A et al (2013) Improving k-t auto-calibrating parallel imaging for 3D cardiac cine MRI using prior-reconstruction static tissue estimation and elimination. In: ISMRM 2013. Abstract 128
10.
Zurück zum Zitat Rochitte CE, Zzevedo CF, Rosario MA, Siqueira MH, Monsao V, Saranathan M, Foo TK, Filho RK, Cerri GG, Ramires JA (2001) Single-breathold four-dimensional assessment of left ventricular morphological and functional parameters by magnetic resonance imaging using the VAST technique. Open Cardiovasc Med J 5:90–98CrossRef Rochitte CE, Zzevedo CF, Rosario MA, Siqueira MH, Monsao V, Saranathan M, Foo TK, Filho RK, Cerri GG, Ramires JA (2001) Single-breathold four-dimensional assessment of left ventricular morphological and functional parameters by magnetic resonance imaging using the VAST technique. Open Cardiovasc Med J 5:90–98CrossRef
11.
12.
Zurück zum Zitat Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26(2):375–385CrossRefPubMed Dietrich O, Raya JG, Reeder SB, Reiser MF, Schoenberg SO (2007) Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters. J Magn Reson Imaging 26(2):375–385CrossRefPubMed
13.
Zurück zum Zitat Wintersperger BJ, Nikolaou K, Dietrich O, Rieber J, Nittka M, Reiser MF, Schoenberg SO (2003) Single breath-hold real-time cine MR imaging improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 13:1931–1936CrossRefPubMed Wintersperger BJ, Nikolaou K, Dietrich O, Rieber J, Nittka M, Reiser MF, Schoenberg SO (2003) Single breath-hold real-time cine MR imaging improved temporal resolution using generalized autocalibrating partially parallel acquisition (GRAPPA) algorithm. Eur Radiol 13:1931–1936CrossRefPubMed
14.
Zurück zum Zitat Huber S, Muthupillai R, Mojibian H, Cheong B, Kouwenhoven M, Flamm SD (2008) Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging. Magn Reson Imaging 26:727–738CrossRefPubMed Huber S, Muthupillai R, Mojibian H, Cheong B, Kouwenhoven M, Flamm SD (2008) Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging. Magn Reson Imaging 26:727–738CrossRefPubMed
15.
Zurück zum Zitat Amano Y, Suzuki Y, van Cauteren M (2008) Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: comparison with two-dimensional cine imaging. Comput Med Imaging Graph 32(1):61–66CrossRefPubMed Amano Y, Suzuki Y, van Cauteren M (2008) Evaluation of global cardiac functional parameters using single-breath-hold three-dimensional cine steady-state free precession MR imaging with two types of speed-up techniques: comparison with two-dimensional cine imaging. Comput Med Imaging Graph 32(1):61–66CrossRefPubMed
16.
Zurück zum Zitat Muthurangu V, Noble N, Boubertakh R et al (2006) Single breath-hold 3D cine imaging of the heart: a non-angulated isotrophic acquisition using SENSE on a 32 channel system. Proceedings of 14th annual meeting. In: ISMRM, Seattle 2006, Abstract 300 Muthurangu V, Noble N, Boubertakh R et al (2006) Single breath-hold 3D cine imaging of the heart: a non-angulated isotrophic acquisition using SENSE on a 32 channel system. Proceedings of 14th annual meeting. In: ISMRM, Seattle 2006, Abstract 300
17.
Zurück zum Zitat Maredia N, Kozerke S, Larghat A, Abidin N, Greenwood JP, Boesiger P, Plein S (2008) Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE. J Cardiovasc Magn Reson 10:27CrossRefPubMedCentralPubMed Maredia N, Kozerke S, Larghat A, Abidin N, Greenwood JP, Boesiger P, Plein S (2008) Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE. J Cardiovasc Magn Reson 10:27CrossRefPubMedCentralPubMed
18.
Zurück zum Zitat Wech T, Pickl W, Tran-Gia J, Ritter C, Beer M, Hahn D, Köstler H (2014) Whole—heart cine MRI in a single breath hold—a compressed sensing accelerated 3D acquisition technique for assessment of cardiac function. Rofo 186(1):37–41PubMed Wech T, Pickl W, Tran-Gia J, Ritter C, Beer M, Hahn D, Köstler H (2014) Whole—heart cine MRI in a single breath hold—a compressed sensing accelerated 3D acquisition technique for assessment of cardiac function. Rofo 186(1):37–41PubMed
19.
Zurück zum Zitat Uribe S, Tangchaoren T, Parish V, Wolf I, Razavi R, Greil G, Schaeffter T (2008) Volumetric cardiac quantification by using 3D dual-phase whole-heart MR imaging. Radiology 248:606–614CrossRefPubMed Uribe S, Tangchaoren T, Parish V, Wolf I, Razavi R, Greil G, Schaeffter T (2008) Volumetric cardiac quantification by using 3D dual-phase whole-heart MR imaging. Radiology 248:606–614CrossRefPubMed
20.
Zurück zum Zitat Srinivasan S, Ennis DB (2013) Variable flip angle balanced steady-state free precession for lower SAR or higher contrast cardiac cine imaging. Magn Reson Med 71(3):1035–1043CrossRef Srinivasan S, Ennis DB (2013) Variable flip angle balanced steady-state free precession for lower SAR or higher contrast cardiac cine imaging. Magn Reson Med 71(3):1035–1043CrossRef
Metadaten
Titel
Single breath hold 3D cardiac cine MRI using kat-ARC: preliminary results at 1.5T
verfasst von
Daniel Jeong
Mark L. Schiebler
Peng Lai
Kang Wang
Karl K. Vigen
Christopher J. François
Publikationsdatum
01.04.2015
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 4/2015
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-015-0615-0

Weitere Artikel der Ausgabe 4/2015

The International Journal of Cardiovascular Imaging 4/2015 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.