Abstract

The clinical electro-oculogram (EOG) is an electrophysiological test of function of the outer retina and retinal pigment epithelium (RPE) in which changes in electrical potential across the RPE are recorded during successive periods of dark and light adaptation. This document presents the 2010 EOG Standard from the International Society for Clinical Electrophysiology of Vision (ISCEV: www.​iscev.​org). This revision has been reorganized and updated, but without changes to the testing protocol from the previous version published in 2006. It describes methods for recording the EOG in clinical applications and gives detailed guidance on technical requirements, practical issues, and reporting of results. It is intended to promote consistent quality of testing and reporting within and between clinical centers.
Literatur
1.
Zurück zum Zitat Marmor MF, Zrenner E, For the International Society of Clinical Electrophysiology of Vision (1993) Standard for clinical electro-oculography. Doc Ophthalmol 85:115–124CrossRefPubMed Marmor MF, Zrenner E, For the International Society of Clinical Electrophysiology of Vision (1993) Standard for clinical electro-oculography. Doc Ophthalmol 85:115–124CrossRefPubMed
2.
Zurück zum Zitat Brown M, Marmor MF, Vaegan, Brigell M, Bach M (2006) ISCEV standard for clinical electro-oculography (EOG) 2006. Doc Ophthalmol 113(3):205–212CrossRefPubMed Brown M, Marmor MF, Vaegan, Brigell M, Bach M (2006) ISCEV standard for clinical electro-oculography (EOG) 2006. Doc Ophthalmol 113(3):205–212CrossRefPubMed
3.
Zurück zum Zitat Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193CrossRefPubMed Brigell M, Bach M, Barber C, Moskowitz A, Robson J (2003) Guidelines for calibration of stimulus and recording parameters used in clinical electrophysiology of vision. Doc Ophthalmol 107:185–193CrossRefPubMed
4.
Zurück zum Zitat Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M, For the International Society for Clinical Electrophysiology of Vision (2009) ISCEV standard for clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M, For the International Society for Clinical Electrophysiology of Vision (2009) ISCEV standard for clinical electroretinography (2008 update). Doc Ophthalmol 118:69–77CrossRefPubMed
5.
Zurück zum Zitat Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M, For the International Society for Clinical Electrophysiology of Vision (2009) ISCEV standard for clinical multifocal electroretinography (2008 update). Doc Ophthalmol 118:225–231CrossRefPubMed Marmor MF, Fulton AB, Holder GE, Miyake Y, Brigell M, Bach M, For the International Society for Clinical Electrophysiology of Vision (2009) ISCEV standard for clinical multifocal electroretinography (2008 update). Doc Ophthalmol 118:225–231CrossRefPubMed
6.
Zurück zum Zitat Holder GE, Brigell MG, Hawlina M, Meigen T, Vaegan, Bach M (2007) ISCEV standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed Holder GE, Brigell MG, Hawlina M, Meigen T, Vaegan, Bach M (2007) ISCEV standard for clinical pattern electroretinography (2007 update). Doc Ophthalmol 114:111–116CrossRefPubMed
7.
Zurück zum Zitat Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 230:111–119CrossRef Odom JV, Bach M, Brigell M, Holder GE, McCulloch DL, Tormene AP, Vaegan (2010) ISCEV standard for clinical visual evoked potentials (2009 update). Doc Ophthalmol 230:111–119CrossRef
8.
Zurück zum Zitat Visual Electrodiagnostics: a guide to procedures. Commissioned by the International society for clinical electrophysiology of vision (ISCEV), to assist practitioners and administrators. www.iscev.org Visual Electrodiagnostics: a guide to procedures. Commissioned by the International society for clinical electrophysiology of vision (ISCEV), to assist practitioners and administrators. www.​iscev.​org
Metadaten
Titel
ISCEV standard for clinical electro-oculography (2010 update)
verfasst von
Michael F. Marmor
Mitchell G. Brigell
Daphne L. McCulloch
Carol A. Westall
Michael Bach
(for the International Society for Clinical Electrophysiology of Vision)
Publikationsdatum
01.02.2011
Verlag
Springer-Verlag
Erschienen in
Documenta Ophthalmologica / Ausgabe 1/2011
Print ISSN: 0012-4486
Elektronische ISSN: 1573-2622
DOI
https://doi.org/10.1007/s10633-011-9259-0

Weitere Artikel der Ausgabe 1/2011

Documenta Ophthalmologica 1/2011 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.