Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2012

01.09.2012

Patient satisfaction and suggestions for improvement of remote ICD monitoring

verfasst von: Helen Høgh Petersen, Mie Christa Jensen Larsen, Olav Wendelboe Nielsen, Finn Kensing, Jesper Hastrup Svendsen

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2012

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The study aim was to evaluate patient acceptance and content with remote follow-up (FU) of their implantable cardioverter defibrillator (ICD) and to estimate patients’ wish for changes in remote follow-up routines.

Methods

Four hundred seventy-four ICD patients at the device follow-up clinic at Rigshospitalet using CareLink® (Medtronic) remote follow-up, who had made ≥2 transmissions, received a questionnaire.

Results

Three hundred eighty-five patients (81.2%) answered. Mean time with ICD was 56 ± 45 months and mean age was 62 ± 13 years; 80% was male. Diagnosis related to ICD implant was: ischemic heart disease in 56% and dilated cardiomyopathy in 21%. Twenty-six percent had primary prophylactic indication. Mean time on remote FU was 16.4 ± 6.9 months. Mean time spent on in-clinic FU (two-way transport and FU) was 4 h and 36 min ± 7 h and 50 min, excluding 12 patients from Greenland and Faroe Islands. Ninety-five percent of the patients was very content or content with remote FU compared to in-clinic FU; 3% was less content and 2% was not content. For scheduled transmissions, 21% of the patients wished for a faster reply (sms or e-mail) compared to current practice with a letter. Eighty-four percent preferred more detailed information concerning ICD leads, battery status, and ICD therapies. A total of 96 patients (25%) had performed extra unscheduled remote transmissions: 20 due to shock, 20 due to alarm, 35 due to palpitations, and 18 for other or combined reasons.

Conclusion

Ninety-five percent of the patients were content with the remote FU. Only 25% had unscheduled transmissions and most unscheduled transmissions were for appropriate reasons. Eighty-four percent of the patients wished for a more detailed response and 21% wished for a faster reply after routine transmissions.
Literatur
1.
Zurück zum Zitat Moss, A. J., Hall, W. J., Cannom, D. S., et al. (1996). Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. New England Journal of Medicine, 335, 1933–1940.PubMedCrossRef Moss, A. J., Hall, W. J., Cannom, D. S., et al. (1996). Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. New England Journal of Medicine, 335, 1933–1940.PubMedCrossRef
2.
Zurück zum Zitat Moss, A. J., Zareba, W., Hall, W. J., et al. (2002). Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. New England Journal of Medicine, 346, 877–883.PubMedCrossRef Moss, A. J., Zareba, W., Hall, W. J., et al. (2002). Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. New England Journal of Medicine, 346, 877–883.PubMedCrossRef
3.
Zurück zum Zitat Bardy, G. H., Lee, K. L., Mark, D. B., et al. (2005). Amiodarone or an implantable defibrillator for congestive heart failure. New England Journal of Medicine, 352, 225–237.PubMedCrossRef Bardy, G. H., Lee, K. L., Mark, D. B., et al. (2005). Amiodarone or an implantable defibrillator for congestive heart failure. New England Journal of Medicine, 352, 225–237.PubMedCrossRef
4.
Zurück zum Zitat Goldberger, Z., & Lampert, R. (2006). Implantable cardioverter-defibrillators: expanding indications and technologies. Journal of the American Medical Association (JAMA), 295(7), 809–818.CrossRef Goldberger, Z., & Lampert, R. (2006). Implantable cardioverter-defibrillators: expanding indications and technologies. Journal of the American Medical Association (JAMA), 295(7), 809–818.CrossRef
5.
Zurück zum Zitat Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., et al. (2008). HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations. Heart Rhythm, 5(6), 907–925.PubMedCrossRef Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., et al. (2008). HRS/EHRA expert consensus on the monitoring of cardiovascular implantable electronic devices (CIEDs): description of techniques, indications, personnel, frequency and ethical considerations. Heart Rhythm, 5(6), 907–925.PubMedCrossRef
6.
Zurück zum Zitat Brugada, P. (2006). What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up? Clinical Research on Cardiology, 95(Suppl 3), III3–III9.CrossRef Brugada, P. (2006). What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up? Clinical Research on Cardiology, 95(Suppl 3), III3–III9.CrossRef
7.
Zurück zum Zitat Deharo, J. C., & Djiane, P. (2006). Home monitoring: what can we expect in the future? Clinical Research on Cardiology, 95(Suppl 3), III36–III39.CrossRef Deharo, J. C., & Djiane, P. (2006). Home monitoring: what can we expect in the future? Clinical Research on Cardiology, 95(Suppl 3), III36–III39.CrossRef
8.
Zurück zum Zitat Heidbuchel, H., Lioen, P., Foulon, S., Huybrechts, W., Ector, J., Willems, R., et al. (2008). Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator. Europace, 10(3), 351–357.PubMedCrossRef Heidbuchel, H., Lioen, P., Foulon, S., Huybrechts, W., Ector, J., Willems, R., et al. (2008). Potential role of remote monitoring for scheduled and unscheduled evaluations of patients with an implantable defibrillator. Europace, 10(3), 351–357.PubMedCrossRef
9.
Zurück zum Zitat Ricci, R. P., Morichelli, L., & Santini, M. (2008). Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization. Europace, 10(2), 164–170.PubMedCrossRef Ricci, R. P., Morichelli, L., & Santini, M. (2008). Home monitoring remote control of pacemaker and implantable cardioverter defibrillator patients in clinical practice: impact on medical management and health-care resource utilization. Europace, 10(2), 164–170.PubMedCrossRef
10.
Zurück zum Zitat Burri, H., & Senouf, D. (2009). Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators. Europace, 11(6), 701–709.PubMedCrossRef Burri, H., & Senouf, D. (2009). Remote monitoring and follow-up of pacemakers and implantable cardioverter defibrillators. Europace, 11(6), 701–709.PubMedCrossRef
11.
Zurück zum Zitat Raatikainen, M. J., Uusimaa, P., van Ginneken, M. M., Janssen, J. P., & Linnaluoto, M. (2008). Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up. Europace, 10(10), 1145–1151.PubMedCrossRef Raatikainen, M. J., Uusimaa, P., van Ginneken, M. M., Janssen, J. P., & Linnaluoto, M. (2008). Remote monitoring of implantable cardioverter defibrillator patients: a safe, time-saving, and cost-effective means for follow-up. Europace, 10(10), 1145–1151.PubMedCrossRef
12.
Zurück zum Zitat Bikou, O., Licka, M., Kathoefer, S., Katus, H. A., & Bauer, A. (2010). Cost savings and safety of ICD remote control by telephone: a prospective, observational study. Journal of Telemedicine and Telecare, 16(7), 403–408.PubMedCrossRef Bikou, O., Licka, M., Kathoefer, S., Katus, H. A., & Bauer, A. (2010). Cost savings and safety of ICD remote control by telephone: a prospective, observational study. Journal of Telemedicine and Telecare, 16(7), 403–408.PubMedCrossRef
13.
Zurück zum Zitat Lazarus, A. (2007). Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database. Pacing and Clinical Electrophysiology, 30(Suppl 1), S2–S12.PubMed Lazarus, A. (2007). Remote, wireless, ambulatory monitoring of implantable pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy systems: analysis of a worldwide database. Pacing and Clinical Electrophysiology, 30(Suppl 1), S2–S12.PubMed
14.
Zurück zum Zitat Nielsen, J. C., Kottkamp, H., Zabel, M., Aliot, E., Kreutzer, U., Bauer, A., et al. (2008). Automatic home monitoring of implantable cardioverter defibrillators. Europace, 10(6), 729–735.PubMedCrossRef Nielsen, J. C., Kottkamp, H., Zabel, M., Aliot, E., Kreutzer, U., Bauer, A., et al. (2008). Automatic home monitoring of implantable cardioverter defibrillators. Europace, 10(6), 729–735.PubMedCrossRef
15.
Zurück zum Zitat Al-Khatib, S. M., Piccini, J. P., Knight, D., Stewart, M., Clapp-Channing, N., & Sanders, G. D. (2010). Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: results from a randomized pilot clinical trial. Journal of Cardiovascular Electrophysiology, 21(5), 545–550.PubMedCrossRef Al-Khatib, S. M., Piccini, J. P., Knight, D., Stewart, M., Clapp-Channing, N., & Sanders, G. D. (2010). Remote monitoring of implantable cardioverter defibrillators versus quarterly device interrogations in clinic: results from a randomized pilot clinical trial. Journal of Cardiovascular Electrophysiology, 21(5), 545–550.PubMedCrossRef
16.
Zurück zum Zitat Matlock, D. D. (2010). Big Brother is watching you: what do patients think about ICD home monitoring? Circulation, 122(4), 319–321.PubMedCrossRef Matlock, D. D. (2010). Big Brother is watching you: what do patients think about ICD home monitoring? Circulation, 122(4), 319–321.PubMedCrossRef
17.
Zurück zum Zitat Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A., Porfili, A., Laudadio, M. T., et al. (2010). Long-term patient acceptance of and satisfaction with implanted device remote monitoring. Europace, 12, 674–679.PubMedCrossRef Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A., Porfili, A., Laudadio, M. T., et al. (2010). Long-term patient acceptance of and satisfaction with implanted device remote monitoring. Europace, 12, 674–679.PubMedCrossRef
19.
Zurück zum Zitat Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. (2010). Automatic remote monitoring of implantable cardioverter-defibrillator lead and generator performance: the lumos-T safely RedUceS RouTine office device follow-up (TRUST) trial. Circulatory and Arrhythmetic Electrophysiology, 3(5), 428–436.CrossRef Varma, N., Michalski, J., Epstein, A. E., & Schweikert, R. (2010). Automatic remote monitoring of implantable cardioverter-defibrillator lead and generator performance: the lumos-T safely RedUceS RouTine office device follow-up (TRUST) trial. Circulatory and Arrhythmetic Electrophysiology, 3(5), 428–436.CrossRef
20.
Zurück zum Zitat Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., et al. (2010). Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study. Circulation, 122(23), 2359–2367.PubMedCrossRef Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., et al. (2010). Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study. Circulation, 122(23), 2359–2367.PubMedCrossRef
21.
Zurück zum Zitat Spencker, S., Coban, N., Koch, L., Schirdewan, A., & Muller, D. (2009). Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Europace, 11(4), 483–488.PubMedCrossRef Spencker, S., Coban, N., Koch, L., Schirdewan, A., & Muller, D. (2009). Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Europace, 11(4), 483–488.PubMedCrossRef
22.
Zurück zum Zitat Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011). CONNECT investigators. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts. Journal of the American College of Cardiology, 57(10), 1181–1189.PubMedCrossRef Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011). CONNECT investigators. The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) trial: the value of wireless remote monitoring with automatic clinician alerts. Journal of the American College of Cardiology, 57(10), 1181–1189.PubMedCrossRef
23.
Zurück zum Zitat Marzegalli, M., Lunati, M., Landolina, M., Perego, G. B., Ricci, R. P., Guenzati, G., et al. (2008). Remote monitoring of CRT-ICD: the multicenter Italian CareLink evaluation—ease of use, acceptance, and organizational implications. Pacing and Clinical Electrophysiology, 31(10), 1259–1264.PubMedCrossRef Marzegalli, M., Lunati, M., Landolina, M., Perego, G. B., Ricci, R. P., Guenzati, G., et al. (2008). Remote monitoring of CRT-ICD: the multicenter Italian CareLink evaluation—ease of use, acceptance, and organizational implications. Pacing and Clinical Electrophysiology, 31(10), 1259–1264.PubMedCrossRef
Metadaten
Titel
Patient satisfaction and suggestions for improvement of remote ICD monitoring
verfasst von
Helen Høgh Petersen
Mie Christa Jensen Larsen
Olav Wendelboe Nielsen
Finn Kensing
Jesper Hastrup Svendsen
Publikationsdatum
01.09.2012
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2012
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-012-9675-4

Weitere Artikel der Ausgabe 3/2012

Journal of Interventional Cardiac Electrophysiology 3/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.