Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 1/2013

01.01.2013

Phrenic nerve palsy during ablation of atrial fibrillation using a 28-mm cryoballoon catheter: predictors and prevention

verfasst von: Michael Kühne, Sven Knecht, David Altmann, Nadine Kawel, Peter Ammann, Beat Schaer, Stefan Osswald, Christian Sticherling

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 1/2013

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purposes of this study were to determine whether predictors of phrenic nerve palsy (PNP) exist and to test whether a standardized ablation protocol may prevent PNP during cryoballoon (CB) ablation using the 28 mm CB.

Methods

Three-dimensional (3D) geometry of the pulmonary veins (PV) and their relationship to the superior vena cava (SVC) was analyzed. Phrenic nerve (PN) stimulation was performed during ablation of the right-sided PVs with a 28-mm CB. The freezing cycle was immediately terminated in case of loss of PN capture.

Results

Sixty-five patients (age, 58 ± 11 years; ejection fraction, 0.59 ± 0.06; left atrial size, 40 ± 5 mm) with paroxysmal atrial fibrillation were included. No persistent PNP was observed. Transient PNP occurred in 4 of 65 patients (6 %). PN function normalized within 24 h in all four patients. A short distance between the right superior PV and the SVC was significantly associated with PNP, but left atrial and 3D PV anatomy were not. Low temperature early during the freezing cycle (<−41 °C at 30 s) predicted PNP with a sensitivity and a specificity of 100 and 98 %, respectively.

Conclusion

The anatomical relationship between the right superior PV and the SVC is a preprocedural predictor for the development of transient PNP, and low temperature early during ablation at the right superior PV is a sensitive warning sign of impending PNP. Despite the use of the 28 mm CB, transient PNP occurred in 6 % of patients undergoing CB ablation.
Literatur
1.
Zurück zum Zitat Haissaguerre, M., Jais, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., et al. (1998). Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. The New England Journal of Medicine, 339, 659–666.PubMedCrossRef Haissaguerre, M., Jais, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., et al. (1998). Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. The New England Journal of Medicine, 339, 659–666.PubMedCrossRef
2.
Zurück zum Zitat Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2010). Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation: Arrhythmia and Electrophysiology, 3, 32–38.CrossRef Cappato, R., Calkins, H., Chen, S. A., Davies, W., Iesaka, Y., Kalman, J., et al. (2010). Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation. Circulation: Arrhythmia and Electrophysiology, 3, 32–38.CrossRef
3.
Zurück zum Zitat Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S. A., et al. (2012). 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm, 9, 632–696.PubMedCrossRef Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S. A., et al. (2012). 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm, 9, 632–696.PubMedCrossRef
4.
Zurück zum Zitat Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., et al. (2007). Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. European Heart Journal, 28, 2231–2237.PubMedCrossRef Van Belle, Y., Janse, P., Rivero-Ayerza, M. J., Thornton, A. S., Jessurun, E. R., Theuns, D., et al. (2007). Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation: feasibility, complications, and short-term outcome. European Heart Journal, 28, 2231–2237.PubMedCrossRef
5.
Zurück zum Zitat Neumann, T., Vogt, J., Schumacher, B., Dorszewski, A., Kuniss, M., Neuser, H., et al. (2008). Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. Journal of the American College of Cardiology, 52, 273–278.PubMedCrossRef Neumann, T., Vogt, J., Schumacher, B., Dorszewski, A., Kuniss, M., Neuser, H., et al. (2008). Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. Journal of the American College of Cardiology, 52, 273–278.PubMedCrossRef
6.
Zurück zum Zitat Chun, K. R., Schmidt, B., Metzner, A., Tilz, R., Zerm, T., Koster, I., et al. (2009). The ‘single big cryoballoon’ technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. European Heart Journal, 30, 699–709.PubMedCrossRef Chun, K. R., Schmidt, B., Metzner, A., Tilz, R., Zerm, T., Koster, I., et al. (2009). The ‘single big cryoballoon’ technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. European Heart Journal, 30, 699–709.PubMedCrossRef
7.
Zurück zum Zitat Kuhne, M., Suter, Y., Altmann, D., Ammann, P., Schaer, B., Osswald, S., et al. (2010). Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: biomarkers of myocardial injury, recurrence rates and pulmonary vein reconnection patterns. Heart Rhythm, 7, 1770–1776. Kuhne, M., Suter, Y., Altmann, D., Ammann, P., Schaer, B., Osswald, S., et al. (2010). Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: biomarkers of myocardial injury, recurrence rates and pulmonary vein reconnection patterns. Heart Rhythm, 7, 1770–1776.
8.
Zurück zum Zitat Packer, D., Irwin, J. M., Champagne, J., Guerra, P., Dubuc, M., Wheelan, K., et al. (2010). Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front STOP-AF pivotal trial. Journal of the American College of Cardiology, 55, E3015–E3016. Packer, D., Irwin, J. M., Champagne, J., Guerra, P., Dubuc, M., Wheelan, K., et al. (2010). Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front STOP-AF pivotal trial. Journal of the American College of Cardiology, 55, E3015–E3016.
9.
Zurück zum Zitat Andrade, J. G., Khairy, P., Guerra, P. G., Deyell, M. W., Rivard, L., Macle, L., et al. (2011). Efficacy and safety of cryoballoon ablation for atrial fibrillation: a systematic review of published studies. Heart Rhythm, 8, 1444–1451.PubMedCrossRef Andrade, J. G., Khairy, P., Guerra, P. G., Deyell, M. W., Rivard, L., Macle, L., et al. (2011). Efficacy and safety of cryoballoon ablation for atrial fibrillation: a systematic review of published studies. Heart Rhythm, 8, 1444–1451.PubMedCrossRef
10.
Zurück zum Zitat Sanchez-Quintana, D., Cabrera, J. A., Climent, V., Farre, J., Weiglein, A., & Ho, S. Y. (2005). How close are the phrenic nerves to cardiac structures? Implications for cardiac interventionalists. Journal of Cardiovascular Electrophysiology, 16, 309–313.PubMedCrossRef Sanchez-Quintana, D., Cabrera, J. A., Climent, V., Farre, J., Weiglein, A., & Ho, S. Y. (2005). How close are the phrenic nerves to cardiac structures? Implications for cardiac interventionalists. Journal of Cardiovascular Electrophysiology, 16, 309–313.PubMedCrossRef
11.
Zurück zum Zitat Van Belle, Y., Knops, P., Janse, P., Rivero-Ayerza, M., Jessurun, E., Szili-Torok, T., et al. (2009). Electro-anatomical mapping of the left atrium before and after cryothermal balloon isolation of the pulmonary veins. Journal of Interventional Cardiac Electrophysiology, 25, 59–65.PubMedCrossRef Van Belle, Y., Knops, P., Janse, P., Rivero-Ayerza, M., Jessurun, E., Szili-Torok, T., et al. (2009). Electro-anatomical mapping of the left atrium before and after cryothermal balloon isolation of the pulmonary veins. Journal of Interventional Cardiac Electrophysiology, 25, 59–65.PubMedCrossRef
12.
Zurück zum Zitat Andrade, J., Dubuc, M., Guerra, P.G., Macle, L., Mondésert, B., Rivard, L., et al. (2012). The biophysics and biomechanics of cryoballoon ablation. Pacing and Clinical Electrophysiology, 35, 1162–1168 Andrade, J., Dubuc, M., Guerra, P.G., Macle, L., Mondésert, B., Rivard, L., et al. (2012). The biophysics and biomechanics of cryoballoon ablation. Pacing and Clinical Electrophysiology, 35, 1162–1168
13.
Zurück zum Zitat Schmidt, B., Chun, K. R., Ouyang, F., Metzner, A., Antz, M., & Kuck, K. H. (2008). Three-dimensional reconstruction of the anatomic course of the right phrenic nerve in humans by pace mapping. Heart Rhythm, 5, 1120–1126.PubMedCrossRef Schmidt, B., Chun, K. R., Ouyang, F., Metzner, A., Antz, M., & Kuck, K. H. (2008). Three-dimensional reconstruction of the anatomic course of the right phrenic nerve in humans by pace mapping. Heart Rhythm, 5, 1120–1126.PubMedCrossRef
14.
Zurück zum Zitat Kojodjojo, P., O’Neill, M. D., Lim, P. B., Malcolm-Lawes, L., Whinnett, Z. I., Salukhe, T. V., et al. (2010). Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart, 96, 1379–1384.PubMedCrossRef Kojodjojo, P., O’Neill, M. D., Lim, P. B., Malcolm-Lawes, L., Whinnett, Z. I., Salukhe, T. V., et al. (2010). Pulmonary venous isolation by antral ablation with a large cryoballoon for treatment of paroxysmal and persistent atrial fibrillation: medium-term outcomes and non-randomised comparison with pulmonary venous isolation by radiofrequency ablation. Heart, 96, 1379–1384.PubMedCrossRef
15.
Zurück zum Zitat Nieto-Tolosa, J., Rodriguez-Sanchez, D., Hurtado-Martinez, J.A., Pinar-Bermudez, E., Penafiel-Verdu, P., Sanchez-Munoz, J.J., et al. (2011). Phrenic nerve identification with cardiac multidetector computed tomography. Revista Española de Cardiología, 64, 942–944 Nieto-Tolosa, J., Rodriguez-Sanchez, D., Hurtado-Martinez, J.A., Pinar-Bermudez, E., Penafiel-Verdu, P., Sanchez-Munoz, J.J., et al. (2011). Phrenic nerve identification with cardiac multidetector computed tomography. Revista Española de Cardiología, 64, 942–944
16.
Zurück zum Zitat Horton, R., Di Biase, L., Reddy, V., Neuzil, P., Mohanty, P., Sanchez, J., et al. (2010). Locating the right phrenic nerve by imaging the right pericardiophrenic artery with computerized tomographic angiography: implications for balloon-based procedures. Heart Rhythm, 7, 937–941.PubMedCrossRef Horton, R., Di Biase, L., Reddy, V., Neuzil, P., Mohanty, P., Sanchez, J., et al. (2010). Locating the right phrenic nerve by imaging the right pericardiophrenic artery with computerized tomographic angiography: implications for balloon-based procedures. Heart Rhythm, 7, 937–941.PubMedCrossRef
17.
Zurück zum Zitat Okumura, Y., Henz, B. D., Bunch, T. J., Dalegrave, C., Johnson, S. B., & Packer, D. L. (2009). Distortion of right superior pulmonary vein anatomy by balloon catheters as a contributor to phrenic nerve injury. Journal of Cardiovascular Electrophysiology, 20, 1151–1157.PubMedCrossRef Okumura, Y., Henz, B. D., Bunch, T. J., Dalegrave, C., Johnson, S. B., & Packer, D. L. (2009). Distortion of right superior pulmonary vein anatomy by balloon catheters as a contributor to phrenic nerve injury. Journal of Cardiovascular Electrophysiology, 20, 1151–1157.PubMedCrossRef
18.
Zurück zum Zitat Kim, D. H., Lu, N., Ghaffari, R., Kim, Y. S., Lee, S. P., Xu, L., et al. (2011). Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy. Nature Materials, 10, 316–323.PubMedCrossRef Kim, D. H., Lu, N., Ghaffari, R., Kim, Y. S., Lee, S. P., Xu, L., et al. (2011). Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy. Nature Materials, 10, 316–323.PubMedCrossRef
19.
Zurück zum Zitat Franceschi, F., Dubuc, M., Guerra, P. G., & Khairy, P. (2011). Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: the first human application. Heart Rhythm, 8, 1068–1071.PubMedCrossRef Franceschi, F., Dubuc, M., Guerra, P. G., & Khairy, P. (2011). Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: the first human application. Heart Rhythm, 8, 1068–1071.PubMedCrossRef
Metadaten
Titel
Phrenic nerve palsy during ablation of atrial fibrillation using a 28-mm cryoballoon catheter: predictors and prevention
verfasst von
Michael Kühne
Sven Knecht
David Altmann
Nadine Kawel
Peter Ammann
Beat Schaer
Stefan Osswald
Christian Sticherling
Publikationsdatum
01.01.2013
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 1/2013
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-012-9740-z

Weitere Artikel der Ausgabe 1/2013

Journal of Interventional Cardiac Electrophysiology 1/2013 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.