Quantitative assessment of a second-generation cryoballoon ablation catheter with new cooling technology—a perspective on potential implications on outcome

verfasst von: Sven Knecht, Michael Kühne, Stefan Osswald, Christian Sticherling

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to assess the differences in cooling behavior between the first-generation cryoballoon (CB-1G) and the second-generation cryoballoon (CB-2G) quantitatively to understand the freezing capabilities and to benefit from the improved efficacy of the CB-2G in patients with atrial fibrillation.

Methods

We analyzed quantitatively the ice formation of the CB-1G and CB-2G catheters in vitro in a 37 °C warm water bath during freezing for 60, 120, 180, 240, and 300 s, respectively.

Results

The mean-covered surface area and the relative coverage of the ice spots on the CB-2G were significantly different from the spots on the CB-1G for the 28-mm CBs but not for the 23-mm CBs. Whereas for the CB-1G, the ice formation was discontiguous with four isolated ice spots; the CB-2G showed a contiguous ice cap covering the entire distal part including the pole of the balloon. No homogeneous cooling behavior could be observed at the equatorial level with both catheters. Temporal differences on the ice formation could be observed for the 28-mm CB-2G but not for the 23-mm CB-2G.

Conclusion

The new-generation CB-2G showed more powerful and homogeneous cooling behavior, especially for the 28-mm CB. Whether this translates into higher long-term success rates is currently unknown. The impact of the more effective cooling and the longer dissolving duration of the ice cap of the new-generation CB-2G on procedural safety needs to be investigated.
Literatur
1.
Zurück zum Zitat Knecht, S., Kühne, M., Altmann, D., Ammann, P., Schaer, B., Osswald, S., & Sticherling, C. (2013). Anatomical predictors for acute and mid-term success of cryoballoon ablation of atrial fibrillation using the 28mm balloon. Journal of Cardiovascular Electrophysiology, 24, 132–138.PubMedCrossRef Knecht, S., Kühne, M., Altmann, D., Ammann, P., Schaer, B., Osswald, S., & Sticherling, C. (2013). Anatomical predictors for acute and mid-term success of cryoballoon ablation of atrial fibrillation using the 28mm balloon. Journal of Cardiovascular Electrophysiology, 24, 132–138.PubMedCrossRef
3.
Zurück zum Zitat Andrade, J. G., Dubuc, M., Guerra, P. G., Landry, E., Coulombe, N., Leduc, H., Rivard, L., Macle, L., Thibault, B., Talajic, M., Roy, D., & Khairy, P. (2013). Pulmonary vein isolation using a second-generation cryoballoon catheter: a randomized comparison of ablation duration and method of deflation. Journal of Cardiovascular Electrophysiology, 24, 692–698.PubMedCrossRef Andrade, J. G., Dubuc, M., Guerra, P. G., Landry, E., Coulombe, N., Leduc, H., Rivard, L., Macle, L., Thibault, B., Talajic, M., Roy, D., & Khairy, P. (2013). Pulmonary vein isolation using a second-generation cryoballoon catheter: a randomized comparison of ablation duration and method of deflation. Journal of Cardiovascular Electrophysiology, 24, 692–698.PubMedCrossRef
4.
Zurück zum Zitat Coulombe, N., Paulin, J., & Su, W. (2013). Improved in vivo performance of second-generation cryoballoon for pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 24, 919–925.PubMedCrossRef Coulombe, N., Paulin, J., & Su, W. (2013). Improved in vivo performance of second-generation cryoballoon for pulmonary vein isolation. Journal of Cardiovascular Electrophysiology, 24, 919–925.PubMedCrossRef
5.
Zurück zum Zitat Fürnkranz, A., Bordignon, S., Schmidt, B., Gunawardene, M., Schulte-Hahn, B., Urban, V., Bode, F., Nowak, B., & Chun, J. K. R. (2013). Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. Journal of Cardiovascular Electrophysiology, 24, 492–497.PubMedCrossRef Fürnkranz, A., Bordignon, S., Schmidt, B., Gunawardene, M., Schulte-Hahn, B., Urban, V., Bode, F., Nowak, B., & Chun, J. K. R. (2013). Improved procedural efficacy of pulmonary vein isolation using the novel second-generation cryoballoon. Journal of Cardiovascular Electrophysiology, 24, 492–497.PubMedCrossRef
6.
Zurück zum Zitat Hussain, S. K., & Ferguson, J. D. (2013). Cool enough-halving pulmonary vein isolation time with the cryoballoon catheter. Journal of Cardiovascular Electrophysiology, 24, 699–700.PubMedCrossRef Hussain, S. K., & Ferguson, J. D. (2013). Cool enough-halving pulmonary vein isolation time with the cryoballoon catheter. Journal of Cardiovascular Electrophysiology, 24, 699–700.PubMedCrossRef
7.
Zurück zum Zitat Andrade, J. G., Dubuc, M., Guerra, P. G., Macle, L., Mondésert, B., Rivard, L., Roy, D., Talajic, M., Thibault, B., & Khairy, P. (2012). The biophysics and biomechanics of cryoballoon ablation. Pacing and Clinical Electrophysiology, 35, 1162–1168.PubMedCrossRef Andrade, J. G., Dubuc, M., Guerra, P. G., Macle, L., Mondésert, B., Rivard, L., Roy, D., Talajic, M., Thibault, B., & Khairy, P. (2012). The biophysics and biomechanics of cryoballoon ablation. Pacing and Clinical Electrophysiology, 35, 1162–1168.PubMedCrossRef
9.
Zurück zum Zitat Kühne, M., Knecht, S., Altmann, D., Kawel, N., Ammann, P., Schaer, B., Osswald, S., & Sticherling, C. (2013). Phrenic nerve palsy during ablation of atrial fibrillation using a 28-mm cryoballoon catheter: predictors and prevention. Journal of Interventional Cardiac Electrophysiology, 36, 47–54.PubMedCrossRef Kühne, M., Knecht, S., Altmann, D., Kawel, N., Ammann, P., Schaer, B., Osswald, S., & Sticherling, C. (2013). Phrenic nerve palsy during ablation of atrial fibrillation using a 28-mm cryoballoon catheter: predictors and prevention. Journal of Interventional Cardiac Electrophysiology, 36, 47–54.PubMedCrossRef
Metadaten
Titel
Quantitative assessment of a second-generation cryoballoon ablation catheter with new cooling technology—a perspective on potential implications on outcome
verfasst von
Sven Knecht
Michael Kühne
Stefan Osswald
Christian Sticherling
Publikationsdatum
01.06.2014
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 1/2014
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-014-9883-1

Weitere Artikel der Ausgabe 1/2014

Journal of Interventional Cardiac Electrophysiology 1/2014 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.