28.08.2015 | Original Research

Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation studies?

verfasst von: Huang Li, Lester A. H. Critchley, Jie Zhang

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

The demise of the pulmonary artery catheter as a gold standard in cardiac output measurement has created the need for new standard. Doppler cardiac output can be measured suprasternally (USCOM) and via the oesophagus (CardioQ). Use in tandem they may provide a reliable trend line of cardiac output changes against which new technologies can be assessed. Data from three similar clinical studies was pooled. Simultaneous USCOM and CardioQ readings, 13 (7–27), were performed every 15–30 min intraoperatively. Within individual patient regression analysis was performed. Data was normalized, CardioQ against USCOM, to eliminate the systematic error component following calibration. Bland–Altman and trend, concordance and polar analysis, were performed on the grouped data. Cardiac output was indexed (CI) to BSA. Data from 53 patients, aged 59 (26–81) years, scheduled for major surgery were included. Within-individual mean (SD) CI was 3.4 (0.6) L min−1 m−2. Correlation was good to excellent in 83 % of cases, R2 > 0.80, and reasonable in 96 %, R2 > 0.60. Percentage error was 38 %, and decreased to 14 % with normalization. The estimated 95 % precision for a single Doppler reading was ±10 %. Concordance rate was 96.6 % (confidence intervals 94.7–99.5 %) and above the >92 % threshold for good trending ability. Polar analysis also confirmed good trending ability. The regression line between Doppler methods was offset with a slope of 0.9, thus CardioQ CI readings increased relative to USCOM. Both Doppler methods trended cardiac output reliably. Used in tandem they provide a new standard to assess cardiac output trending.
Literatur
2.
Zurück zum Zitat Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed
3.
Zurück zum Zitat Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed
4.
5.
Zurück zum Zitat Preiss David, Fisher Joseph. A measure of confidence in Bland–Altman Analysis for the interchangeability of two methods of measurement. J Clin Monit Comput. 2008;22:257–9.CrossRefPubMed Preiss David, Fisher Joseph. A measure of confidence in Bland–Altman Analysis for the interchangeability of two methods of measurement. J Clin Monit Comput. 2008;22:257–9.CrossRefPubMed
6.
Zurück zum Zitat Olofsen E, Dahan A, Borsboom G, Drummond G. Improvements in the application and reporting of advanced Bland–Altman methods of comparison. J Clin Monit Comput. 2015;29(1):127–39.CrossRefPubMed Olofsen E, Dahan A, Borsboom G, Drummond G. Improvements in the application and reporting of advanced Bland–Altman methods of comparison. J Clin Monit Comput. 2015;29(1):127–39.CrossRefPubMed
7.
Zurück zum Zitat Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180–92.CrossRefPubMed Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010;111:1180–92.CrossRefPubMed
8.
Zurück zum Zitat Chong SW, Peyton PJ. A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM). Anaesthesia. 2012;67:1266–71.CrossRefPubMed Chong SW, Peyton PJ. A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM). Anaesthesia. 2012;67:1266–71.CrossRefPubMed
9.
Zurück zum Zitat Dark PM, Singer M. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med. 2004;30:2060–6.CrossRefPubMed Dark PM, Singer M. The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults. Intensive Care Med. 2004;30:2060–6.CrossRefPubMed
10.
Zurück zum Zitat Critchley LA, Huang L, Zhang J. Continuous cardiac output monitoring: what do validation studies tell us? Curr Anesthesiol Rep. 2014;4:242–50.CrossRef Critchley LA, Huang L, Zhang J. Continuous cardiac output monitoring: what do validation studies tell us? Curr Anesthesiol Rep. 2014;4:242–50.CrossRef
11.
Zurück zum Zitat Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014;42:631–9.PubMed Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014;42:631–9.PubMed
12.
Zurück zum Zitat Diaper J, Ellenberger C, Villiger Y, Robert J, Inan C, Tschopp JM, Licker M. Comparison of cardiac output as assessed by transesophageal echo-Doppler and transpulmonary thermodilution in patients undergoing thoracic surgery. J Clin Anesth. 2010;22:97–103.CrossRefPubMed Diaper J, Ellenberger C, Villiger Y, Robert J, Inan C, Tschopp JM, Licker M. Comparison of cardiac output as assessed by transesophageal echo-Doppler and transpulmonary thermodilution in patients undergoing thoracic surgery. J Clin Anesth. 2010;22:97–103.CrossRefPubMed
13.
Zurück zum Zitat Coats AJS. Doppler ultrasonic measurement of cardiac output: reproducibility and validation. Eur Heart J. 1990;11(Suppl I):49–61.CrossRefPubMed Coats AJS. Doppler ultrasonic measurement of cardiac output: reproducibility and validation. Eur Heart J. 1990;11(Suppl I):49–61.CrossRefPubMed
14.
Zurück zum Zitat Lewis JF, Kuo LC, Nelson JG, Liamcher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation. 1984;70:425–31.CrossRefPubMed Lewis JF, Kuo LC, Nelson JG, Liamcher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation. 1984;70:425–31.CrossRefPubMed
15.
Zurück zum Zitat Huang L, Critchley LA, Zhang J. Major upper abdominal surgery alters the calibration of BioReactance cardiac output readings, the NICOM, when comparisons are made against suprasternal and esophageal Doppler intraoperatively. Anesth Analg 2015; (in press). Huang L, Critchley LA, Zhang J. Major upper abdominal surgery alters the calibration of BioReactance cardiac output readings, the NICOM, when comparisons are made against suprasternal and esophageal Doppler intraoperatively. Anesth Analg 2015; (in press).
16.
Zurück zum Zitat Critchley LA. Differences between cardio-q and uscom doppler cardiac output readings in high risk surgery patients. Br J Anaesth. 2012;108(Suppl 2):113–114. Critchley LA. Differences between cardio-q and uscom doppler cardiac output readings in high risk surgery patients. Br J Anaesth. 2012;108(Suppl 2):113–114.
17.
Zurück zum Zitat Cattermole G, Leung P, Tang C, Smith B, Graham C, Rainer T. A new method to score the quality of USCOM scans. Hong Kong J Emerg Med. 2009;16:288. Cattermole G, Leung P, Tang C, Smith B, Graham C, Rainer T. A new method to score the quality of USCOM scans. Hong Kong J Emerg Med. 2009;16:288.
18.
Zurück zum Zitat Critchley LA, Huang L. USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy. J Clin Monit Comput. 2014;28:83–93.CrossRefPubMed Critchley LA, Huang L. USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy. J Clin Monit Comput. 2014;28:83–93.CrossRefPubMed
19.
Zurück zum Zitat Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
20.
Zurück zum Zitat Perrino AC Jr, O’Connor T, Luther M. Transtracheal Doppler cardiac output monitoring: comparison to thermodilution during noncardiac surgery. Anesth Analg. 1994;78:1060–6.CrossRefPubMed Perrino AC Jr, O’Connor T, Luther M. Transtracheal Doppler cardiac output monitoring: comparison to thermodilution during noncardiac surgery. Anesth Analg. 1994;78:1060–6.CrossRefPubMed
21.
Zurück zum Zitat Axiak Flammer SM, Critchley LA, Weber A, Pirbodaghi T, Brinks H, Vandenberghe S. Reliability of lithium dilution cardiac output in anaesthetized sheep. Br J Anaesth. 2013;111:833–9.CrossRefPubMed Axiak Flammer SM, Critchley LA, Weber A, Pirbodaghi T, Brinks H, Vandenberghe S. Reliability of lithium dilution cardiac output in anaesthetized sheep. Br J Anaesth. 2013;111:833–9.CrossRefPubMed
22.
Zurück zum Zitat Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth. 2011;25:536–46.CrossRefPubMed Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth. 2011;25:536–46.CrossRefPubMed
23.
Zurück zum Zitat Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA. Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg. 2005;100:748–53.CrossRefPubMed Critchley LA, Peng ZY, Fok BS, Lee A, Phillips RA. Testing the reliability of a new ultrasonic cardiac output monitor, the USCOM, by using aortic flowprobes in anesthetized dogs. Anesth Analg. 2005;100:748–53.CrossRefPubMed
24.
Zurück zum Zitat Phillips RA, Hood SG, Jacobson BM, West MJ, Wan L, May CN. Pulmonary Artery Catheter (PAC) Accuracy and Efficacy compared with flow probe and transcutaneous Doppler (USCOM): an ovine cardiac output validation. Crit Care Res Pract 2012. doi:10.1155/2012/621496.PubMedPubMedCentral Phillips RA, Hood SG, Jacobson BM, West MJ, Wan L, May CN. Pulmonary Artery Catheter (PAC) Accuracy and Efficacy compared with flow probe and transcutaneous Doppler (USCOM): an ovine cardiac output validation. Crit Care Res Pract 2012. doi:10.​1155/​2012/​621496.PubMedPubMedCentral
25.
Zurück zum Zitat Singer M, Clarke J, Bennett ED. Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med. 1989;17(5):447–52 Singer M, Clarke J, Bennett ED. Continuous hemodynamic monitoring by esophageal Doppler. Crit Care Med. 1989;17(5):447–52
26.
Zurück zum Zitat Valtier B, Cholley BP, Belot JP, de la Coussaye JE, Mateo J, Payen DM. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Res Crit Care Med. 1998;158:77–83.CrossRef Valtier B, Cholley BP, Belot JP, de la Coussaye JE, Mateo J, Payen DM. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler. Am J Res Crit Care Med. 1998;158:77–83.CrossRef
27.
Zurück zum Zitat Huang L, Critchley LA. Study to determine the repeatability of supra-sternal Doppler (ultrasound cardiac output monitor) during general anaesthesia: effects of scan quality, flow volume, and increasing age. Br J Anaesth. 2013;111:907–15.CrossRefPubMed Huang L, Critchley LA. Study to determine the repeatability of supra-sternal Doppler (ultrasound cardiac output monitor) during general anaesthesia: effects of scan quality, flow volume, and increasing age. Br J Anaesth. 2013;111:907–15.CrossRefPubMed
28.
Zurück zum Zitat Huang L, Critchley LA, Lok RL, Liu Y. Correlation between supra-sternal Doppler cardiac output (USCOM) measurements and chest radiological features. Anaesthesia. 2013;68:1156–60.CrossRefPubMed Huang L, Critchley LA, Lok RL, Liu Y. Correlation between supra-sternal Doppler cardiac output (USCOM) measurements and chest radiological features. Anaesthesia. 2013;68:1156–60.CrossRefPubMed
29.
Zurück zum Zitat O’Rourke MF, Hashimoto J Mechanical factors in arterial aging: a clinical perspective. J Am Coll Cardiol 2007; 50:1–13. Doppler. Crit Care Med 1989; 17:447–52. O’Rourke MF, Hashimoto J Mechanical factors in arterial aging: a clinical perspective. J Am Coll Cardiol 2007; 50:1–13. Doppler. Crit Care Med 1989; 17:447–52.
30.
Zurück zum Zitat Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820–6.CrossRefPubMed Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820–6.CrossRefPubMed
31.
Zurück zum Zitat Noblett SE, Snowden CP, Shenton BK, Horgan AF. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg. 2006;93:1069–76.CrossRefPubMed Noblett SE, Snowden CP, Shenton BK, Horgan AF. Randomized clinical trial assessing the effect of Doppler-optimized fluid management on outcome after elective colorectal resection. Br J Surg. 2006;93:1069–76.CrossRefPubMed
33.
Zurück zum Zitat Schlöglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014;61:452–79.CrossRefPubMed Schlöglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014;61:452–79.CrossRefPubMed
Metadaten
Titel
Does using two Doppler cardiac output monitors in tandem provide a reliable trend line of changes for validation studies?
verfasst von
Huang Li
Lester A. H. Critchley
Jie Zhang
Publikationsdatum
28.08.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 5/2016
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9753-0

Weitere Artikel der Ausgabe 5/2016

Journal of Clinical Monitoring and Computing 5/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.