Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 4/2018

11.09.2017 | Original Research

K-band Doppler radar for contact-less overnight sleep marker assessment: a pilot validation study

verfasst von: Rakesh Vasireddy, Corinne Roth, Johannes Mathis, Josef Goette, Marcel Jacomet, Andreas Vogt

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2018

Einloggen, um Zugang zu erhalten

Abstract

An estimated 45 million persons in Europe are annually subjected to sleep-wake disorders. State-of-the-art polysomnography provides sophisticated insights into sleep (patho)physiology. A drawback of the method, however, is the obtrusive setting dependent on a clinical-based sleep laboratory with high operational costs. A contact-less prototype was developed to monitor limb movements and vital signs during sleep. A dual channel K-band Doppler radar transceiver captured limb movements and periodic chest wall motion due to respiration and heart activity. A wavelet transform based multi-resolution analysis (MRA) approach isolated limb movements, respiration, and heart rate from the demodulated signal. A test bench setup characterized the prototype simulating near physiological chest wall motions caused by periodic respiration and heartbeats in humans. Single- and multi-tone test bench simulations showed extremely low relative percentage errors of the prototype for respiratory and heart rate within −2 and 1%. The performance of the prototype was validated in overnight comparative studies, involving two healthy volunteers, with polysomnography as the reference. The prototype has successfully classified limb movements, with a sensitivity and specificity of 88.9 and 76.8% respectively, and has achieved accurate respiratory and heart rate measurement performance with overall absolute errors of 1 breath per minute for respiration and 3 beats per minute for heart rate. This pilot study shows that K-band Doppler radar and wavelet transform MRA seem to be valid for overnight sleep marker assessment. The contact-less approach might offer a promising solution for home-based sleep monitoring and assessment.
Literatur
1.
Zurück zum Zitat Gustavsson A, Svensson M, Jacobi F, Allgulander C, Alonso J, Beghi E, Dodel R, Ekman M, Faravelli C, Fratiglioni L, Gannon B, Jones DH, Jennum P, Jordanova A, Jonsson L, Karampampa K, Knapp M, Kobelt G, Kurth T, Lieb R, Linde M, Ljungcrantz C, Maercker A, Melin B, Moscarelli M, Musayev A, Norwood F, Preisig M, Pugliatti M, Rehm J, Salvador-Carulla L, Schlehofer B, Simon R, Steinhausen HC, Stovner LJ, Vallat JM, Van den Bergh P, van Os J, Vos P, Xu W, Wittchen HU, Jonsson B, Olesen J, Group CD. Cost of disorders of the brain in Europe 2010. Eur Neuropsychopharmacol. 2011;21(10):718–79. doi:10.1016/j.euroneuro.2011.08.008.CrossRefPubMed Gustavsson A, Svensson M, Jacobi F, Allgulander C, Alonso J, Beghi E, Dodel R, Ekman M, Faravelli C, Fratiglioni L, Gannon B, Jones DH, Jennum P, Jordanova A, Jonsson L, Karampampa K, Knapp M, Kobelt G, Kurth T, Lieb R, Linde M, Ljungcrantz C, Maercker A, Melin B, Moscarelli M, Musayev A, Norwood F, Preisig M, Pugliatti M, Rehm J, Salvador-Carulla L, Schlehofer B, Simon R, Steinhausen HC, Stovner LJ, Vallat JM, Van den Bergh P, van Os J, Vos P, Xu W, Wittchen HU, Jonsson B, Olesen J, Group CD. Cost of disorders of the brain in Europe 2010. Eur Neuropsychopharmacol. 2011;21(10):718–79. doi:10.​1016/​j.​euroneuro.​2011.​08.​008.CrossRefPubMed
2.
Zurück zum Zitat Ohayon MM. Epidemiology of insomnia: what we know and what we still need to learn. Sleep Med Rev. 2002;6(2):97–111.CrossRefPubMed Ohayon MM. Epidemiology of insomnia: what we know and what we still need to learn. Sleep Med Rev. 2002;6(2):97–111.CrossRefPubMed
5.
Zurück zum Zitat McNicholas WT, Bonsignore MR. Sleep apnoea as an independent risk factor for cardiovascular disease: current evidence, basic mechanisms and research priorities. Eur Respir J. 2006;29:156–78.CrossRef McNicholas WT, Bonsignore MR. Sleep apnoea as an independent risk factor for cardiovascular disease: current evidence, basic mechanisms and research priorities. Eur Respir J. 2006;29:156–78.CrossRef
7.
Zurück zum Zitat Mathis J, Schreier D. Daytime sleepiness and driving behaviour (Tagesschlafrigkeit und Fahrverhalten.). Ther Umsch. 2014;71(11):679–86.CrossRefPubMed Mathis J, Schreier D. Daytime sleepiness and driving behaviour (Tagesschlafrigkeit und Fahrverhalten.). Ther Umsch. 2014;71(11):679–86.CrossRefPubMed
11.
Zurück zum Zitat Berry RB BR, Gamaldo CE, Harding SM, Lloyd RM, Marcus CL, Vaughn BV, The American Academy of Sleep Medicine. (2012) The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, Version 2.3. Berry RB BR, Gamaldo CE, Harding SM, Lloyd RM, Marcus CL, Vaughn BV, The American Academy of Sleep Medicine. (2012) The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, Version 2.3.
12.
Zurück zum Zitat Newell J, Mairesse O, Verbanck P, Neu D. Is a one-night stay in the lab really enough to conclude? First-night effect and night-to-night variability in polysomnographic recordings among different clinical population samples. Psychiatry Res. 2012;200(2–3):795–801. doi:10.1016/j.psychres.2012.07.045.CrossRefPubMed Newell J, Mairesse O, Verbanck P, Neu D. Is a one-night stay in the lab really enough to conclude? First-night effect and night-to-night variability in polysomnographic recordings among different clinical population samples. Psychiatry Res. 2012;200(2–3):795–801. doi:10.​1016/​j.​psychres.​2012.​07.​045.CrossRefPubMed
13.
Zurück zum Zitat Meyer TJ, Eveloff SE, Kline LR, Millman RP. One negative polysomnogram does not exclude obstructive sleep apnea. Chest. 1993;103(3):756–60.CrossRefPubMed Meyer TJ, Eveloff SE, Kline LR, Millman RP. One negative polysomnogram does not exclude obstructive sleep apnea. Chest. 1993;103(3):756–60.CrossRefPubMed
14.
18.
Zurück zum Zitat Cole RJ, Kripke DF, Gruen W, Mullaney DJ, Gillin JC. Automatic sleep/wake identification from wrist activity. Sleep. 1992;15(5):461–9.CrossRefPubMed Cole RJ, Kripke DF, Gruen W, Mullaney DJ, Gillin JC. Automatic sleep/wake identification from wrist activity. Sleep. 1992;15(5):461–9.CrossRefPubMed
19.
Zurück zum Zitat Pollak CP, Tryon WW, Nagaraja H, Dzwonczyk R. How accurately does wrist actigraphy identify the states of sleep and wakefulness? Sleep. 2001;24(8):957–65.CrossRefPubMed Pollak CP, Tryon WW, Nagaraja H, Dzwonczyk R. How accurately does wrist actigraphy identify the states of sleep and wakefulness? Sleep. 2001;24(8):957–65.CrossRefPubMed
20.
Zurück zum Zitat Snyder F, Hobson JA, Morrison DF, Goldfrank F. Changes in respiration, heart rate, and systolic blood pressure in human sleep. J Appl Physiol. 1964;19:417–22.CrossRefPubMed Snyder F, Hobson JA, Morrison DF, Goldfrank F. Changes in respiration, heart rate, and systolic blood pressure in human sleep. J Appl Physiol. 1964;19:417–22.CrossRefPubMed
22.
Zurück zum Zitat Pedro F, Xi L, Mustafa R, Reinder H, Ronald MA, Jérôme R. Sleep stage classification with ECG and respiratory effort. Physiol Meas. 2015;36(10):2027.CrossRef Pedro F, Xi L, Mustafa R, Reinder H, Ronald MA, Jérôme R. Sleep stage classification with ECG and respiratory effort. Physiol Meas. 2015;36(10):2027.CrossRef
23.
Zurück zum Zitat De Chazal P, Sadr N Sleep apnoea classification using heart rate variability, ECG derived respiration and cardiopulmonary coupling parameters. In: 2016 38th Annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 16–20 Aug 2016. pp. 3203–3206. doi:10.1109/EMBC.2016.7591410. De Chazal P, Sadr N Sleep apnoea classification using heart rate variability, ECG derived respiration and cardiopulmonary coupling parameters. In: 2016 38th Annual international conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 16–20 Aug 2016. pp. 3203–3206. doi:10.​1109/​EMBC.​2016.​7591410.
26.
Zurück zum Zitat Wang J, Wang X, Chen L, Huangfu J, Li C, Ran L. Noncontact distance and amplitude-independent vibration measurement based on an extended DACM algorithm. IEEE Trans Instrum Meas. 2014;63(1):145–53. doi:10.1109/TIM.2013.2277530.CrossRef Wang J, Wang X, Chen L, Huangfu J, Li C, Ran L. Noncontact distance and amplitude-independent vibration measurement based on an extended DACM algorithm. IEEE Trans Instrum Meas. 2014;63(1):145–53. doi:10.​1109/​TIM.​2013.​2277530.CrossRef
27.
Zurück zum Zitat Park BK, Boric-Lubecke O, Lubecke VM. Arctangent demodulation with DC offset compensation in quadrature Doppler radar receiver systems. IEEE Trans Microw Theory Tech. 2007;55(5):1073–9. doi:10.1109/TMTT.2007.895653.CrossRef Park BK, Boric-Lubecke O, Lubecke VM. Arctangent demodulation with DC offset compensation in quadrature Doppler radar receiver systems. IEEE Trans Microw Theory Tech. 2007;55(5):1073–9. doi:10.​1109/​TMTT.​2007.​895653.CrossRef
28.
Zurück zum Zitat Lin HD, Lee YS, Chuang BN. Using dual-antenna nanosecond pulse near-field sensing technology for non-contact and continuous blood pressure measurement. In: 2012 Annual International Conference of the IEEE engineering in Medicine and Biology Society, 28 Aug 2012–1 Sept 2012. pp. 219–22. doi:10.1109/EMBC.2012.6345909. Lin HD, Lee YS, Chuang BN. Using dual-antenna nanosecond pulse near-field sensing technology for non-contact and continuous blood pressure measurement. In: 2012 Annual International Conference of the IEEE engineering in Medicine and Biology Society, 28 Aug 2012–1 Sept 2012. pp. 219–22. doi:10.​1109/​EMBC.​2012.​6345909.
29.
Zurück zum Zitat Byung-Kwon P, Yamada S, Boric-Lubecke O, Lubecke V. Single-channel receiver limitations in Doppler radar measurements of periodic motion. In: 2006 IEEE Radio and Wireless Symposium, 17–19 Jan 2006. pp. 99–102. doi:10.1109/RWS.2006.1615104. Byung-Kwon P, Yamada S, Boric-Lubecke O, Lubecke V. Single-channel receiver limitations in Doppler radar measurements of periodic motion. In: 2006 IEEE Radio and Wireless Symposium, 17–19 Jan 2006. pp. 99–102. doi:10.​1109/​RWS.​2006.​1615104.
30.
Zurück zum Zitat Xu W, Gu C, Li C, Sarrafzadeh M. Robust Doppler radar demodulation via compressed sensing. Electron Lett. 2012;48(22):1428–30.CrossRef Xu W, Gu C, Li C, Sarrafzadeh M. Robust Doppler radar demodulation via compressed sensing. Electron Lett. 2012;48(22):1428–30.CrossRef
31.
32.
Zurück zum Zitat Boric-Lubecke O, Lubecke V, Mostafanezhad I. Amplitude modulation issues in Doppler radar heart signal extraction. In: 2011 IEEE topical conference on biomedical wireless technologies, networks, and sensing systems. 2011. doi:10.1109/BIOWIRELESS.2011.5724357. Boric-Lubecke O, Lubecke V, Mostafanezhad I. Amplitude modulation issues in Doppler radar heart signal extraction. In: 2011 IEEE topical conference on biomedical wireless technologies, networks, and sensing systems. 2011. doi:10.​1109/​BIOWIRELESS.​2011.​5724357.
34.
37.
Zurück zum Zitat Fox NA, Heneghan C, Gonzalez M, Shouldice RB, De Chazal P. An evaluation of a non-contact biomotion sensor with actimetry. In: 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi:10.1109/IEMBS.2007.4352877. Fox NA, Heneghan C, Gonzalez M, Shouldice RB, De Chazal P. An evaluation of a non-contact biomotion sensor with actimetry. In: 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. doi:10.​1109/​IEMBS.​2007.​4352877.
38.
Zurück zum Zitat Shouldice RB, Heneghan C, Petres G, Zaffaroni A, Boyle P, McNicholas W. Chazal Pd Real time breathing rate estimation from a non contact biosensor. In: 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 31 Aug 2010–4 Sept 2010. pp. 630–3. doi:10.1109/IEMBS.2010.5627275. Shouldice RB, Heneghan C, Petres G, Zaffaroni A, Boyle P, McNicholas W. Chazal Pd Real time breathing rate estimation from a non contact biosensor. In: 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology, 31 Aug 2010–4 Sept 2010. pp. 630–3. doi:10.​1109/​IEMBS.​2010.​5627275.
39.
Zurück zum Zitat Rahman T, Adams AT, Ravichandran RV, Zhang M, Patel SN, Kientz JA, Choudhury T. (2015) DoppleSleep: a contactless unobtrusive sleep sensing system using short-range Doppler radar. Paper presented at the Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing, Osaka, Japan. Rahman T, Adams AT, Ravichandran RV, Zhang M, Patel SN, Kientz JA, Choudhury T. (2015) DoppleSleep: a contactless unobtrusive sleep sensing system using short-range Doppler radar. Paper presented at the Proceedings of the 2015 ACM International Joint Conference on Pervasive and Ubiquitous Computing, Osaka, Japan.
Metadaten
Titel
K-band Doppler radar for contact-less overnight sleep marker assessment: a pilot validation study
verfasst von
Rakesh Vasireddy
Corinne Roth
Johannes Mathis
Josef Goette
Marcel Jacomet
Andreas Vogt
Publikationsdatum
11.09.2017
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2018
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-017-0060-9

Weitere Artikel der Ausgabe 4/2018

Journal of Clinical Monitoring and Computing 4/2018 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.