Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia

verfasst von: Jeongmin Kim, Jun Hwan Kwon, Eungjin Kim, Sun Kook Yoo, Cheung-soo Shin

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

We aimed to evaluate changes in respiratory pattern after sedation by simultaneously applying a respiratory volume monitor (ExSpiron1Xi, RVM) and infrared thermography (IRT) to patients undergoing spinal anesthesia during endoscopic urologic surgeries. After spinal anesthesia was performed, the patient was placed in a lithotomy position for surgery. Then, we established the baseline of the RVM, and started monitoring the mouth and nose with the infrared camera. SpO2 was continuously measured throughout these processes. Once the baseline was set, 0.05 mg/kg midazolam was administered for sedation. Apnea was defined as cessation of airflow for ≥ 10 s with respiratory rate of < 6 breaths/min; hypopnea was defined as a decrease in oxygen hemoglobin of > 4%, compared to baseline. We measured the time at which apnea was detected by IRT, the time at which hypopnea was detected by RVM, and the time at which hypoxia was detected by SpO2. Twenty patients (age: 68.9 ± 11.2 years, body mass index: 24.2 ± 2.6 kg/min2) completed the study. Before sedation, the baseline correlation coefficient of respiratory rate detection between RVM and IRT was 0.866. After midazolam administration, apnea was detected in all subjects within the first 5 min by IRT; the median time required to detect apnea was 102.5 [interquartile range (IQR) 25–75%: 80–155] s. Hypopnea was detected in all subjects within the first 5 min by RVM: the median time required to detect hypopnea was 142.5 (IQR 115–185.2) s. The median time required for SpO2 to decrease > 4% from baseline was 160 (IQR 125–205) s. Our results suggest that IRT can be useful for rapid detection of respiratory changes in patients undergoing sedation following spinal anesthesia for endoscopic urologic procedures.
Literatur
1.
Zurück zum Zitat Miller RD. Miller’s anesthesia. 8th ed. Philadelphia: Elsevier/Saunders; 2015. Miller RD. Miller’s anesthesia. 8th ed. Philadelphia: Elsevier/Saunders; 2015.
5.
Zurück zum Zitat Bezel R, Russi E, Kronauer H, Mothersill I. Life-threatening apnea after midazolam administration in a patient with obstructive sleep apnea syndrome. Schweiz Med Wochenschr. 1987;117(15):579–83.PubMed Bezel R, Russi E, Kronauer H, Mothersill I. Life-threatening apnea after midazolam administration in a patient with obstructive sleep apnea syndrome. Schweiz Med Wochenschr. 1987;117(15):579–83.PubMed
6.
Zurück zum Zitat Kiriyama S, Gotoda T, Sano H, Oda I, Nishimoto F, Hirashima T, Kusano C, Kuwano H. Safe and effective sedation in endoscopic submucosal dissection for early gastric cancer: a randomized comparison between propofol continuous infusion and intermittent midazolam injection. J Gastroenterol. 2010;45(8):831–7. https://doi.org/10.1007/s00535-010-0222-8.CrossRefPubMed Kiriyama S, Gotoda T, Sano H, Oda I, Nishimoto F, Hirashima T, Kusano C, Kuwano H. Safe and effective sedation in endoscopic submucosal dissection for early gastric cancer: a randomized comparison between propofol continuous infusion and intermittent midazolam injection. J Gastroenterol. 2010;45(8):831–7. https://​doi.​org/​10.​1007/​s00535-010-0222-8.CrossRefPubMed
7.
Zurück zum Zitat Beitz A, Riphaus A, Meining A, Kronshage T, Geist C, Wagenpfeil S, Weber A, Jung A, Bajbouj M, Pox C, Schneider G, Schmid RM, Wehrmann T, von Delius S. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol. 2012;107(8):1205–12. https://doi.org/10.1038/ajg.2012.136.CrossRefPubMed Beitz A, Riphaus A, Meining A, Kronshage T, Geist C, Wagenpfeil S, Weber A, Jung A, Bajbouj M, Pox C, Schneider G, Schmid RM, Wehrmann T, von Delius S. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol. 2012;107(8):1205–12. https://​doi.​org/​10.​1038/​ajg.​2012.​136.CrossRefPubMed
9.
Zurück zum Zitat Qadeer MA, Vargo JJ, Dumot JA, Lopez R, Trolli PA, Stevens T, Parsi MA, Sanaka MR, Zuccaro G. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76. quiz 819–20.CrossRefPubMed Qadeer MA, Vargo JJ, Dumot JA, Lopez R, Trolli PA, Stevens T, Parsi MA, Sanaka MR, Zuccaro G. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76. quiz 819–20.CrossRefPubMed
15.
Zurück zum Zitat Chekmenev SY, Rara H, Farag AA. Non-contact, wavelet-based measurement of vital signs using thermal imaging. In: Proceedings of the The first international conference on graphics, vision, and image processing (GVIP), Cairo, Egypt, 2005. Chekmenev SY, Rara H, Farag AA. Non-contact, wavelet-based measurement of vital signs using thermal imaging. In: Proceedings of the The first international conference on graphics, vision, and image processing (GVIP), Cairo, Egypt, 2005.
16.
Zurück zum Zitat Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless Monitoring of Breathing Function. In: Proceedings of the 26th Annual International Conference of the IEEE EMBS. San Francisco, CA, USA, September 1–5, 2004. Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless Monitoring of Breathing Function. In: Proceedings of the 26th Annual International Conference of the IEEE EMBS. San Francisco, CA, USA, September 1–5, 2004.
18.
Zurück zum Zitat Fei J, Pavlidis I. Virtual Thermistor. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS. Cité Internationale, Lyon, France, August 23–26, 2007. Fei J, Pavlidis I. Virtual Thermistor. In: Proceedings of the 29th Annual International Conference of the IEEE EMBS. Cité Internationale, Lyon, France, August 23–26, 2007.
19.
Zurück zum Zitat Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless monitoring of breathing function 2004. Murthy R, Pavlidis I, Tsiamyrtzis P. Touchless monitoring of breathing function 2004.
23.
Zurück zum Zitat Wareham R, Lasenby J, Cameron P, Iles R. Structured light plethysmography (SLP) compared to spirometry: a pilot study. In: Proceedings of the European Respiratory Society Annual Congress, 2009. Wareham R, Lasenby J, Cameron P, Iles R. Structured light plethysmography (SLP) compared to spirometry: a pilot study. In: Proceedings of the European Respiratory Society Annual Congress, 2009.
24.
Zurück zum Zitat Aoki H, Koshiji K, Nakamura H, Takemura Y, Nakajima M. Study on respiration monitoring method using near-infrared multiple slit-lights projection. In: Proceedings of the Micro-NanoMechatronics and Human Science, 2005 IEEE International Symposium on, 2005. Aoki H, Koshiji K, Nakamura H, Takemura Y, Nakajima M. Study on respiration monitoring method using near-infrared multiple slit-lights projection. In: Proceedings of the Micro-NanoMechatronics and Human Science, 2005 IEEE International Symposium on, 2005.
26.
Zurück zum Zitat Cala S, Kenyon C, Ferrigno G, Carnevali P, Aliverti A, Pedotti A, Macklem P, Rochester D. Chest wall and lung volume estimation by optical reflectance motion analysis. J Appl Physiol. 1996;81(6):2680–9.CrossRefPubMed Cala S, Kenyon C, Ferrigno G, Carnevali P, Aliverti A, Pedotti A, Macklem P, Rochester D. Chest wall and lung volume estimation by optical reflectance motion analysis. J Appl Physiol. 1996;81(6):2680–9.CrossRefPubMed
30.
Zurück zum Zitat Bromage PR. Epidural analgesia. Philadelphia: WB Saunders; 1978. Bromage PR. Epidural analgesia. Philadelphia: WB Saunders; 1978.
31.
Zurück zum Zitat Lucas BD, Kanade T. An iterative image registration technique with an application to stereo vision. 1981. Lucas BD, Kanade T. An iterative image registration technique with an application to stereo vision. 1981.
32.
Zurück zum Zitat Tomasi C, Kanade T. Detection and tracking of point features. 1991. Tomasi C, Kanade T. Detection and tracking of point features. 1991.
33.
Zurück zum Zitat Li H, Lu J, Shi G, Zhang Y. Tracking features in retinal images of adaptive optics confocal scanning laser ophthalmoscope using KLT-SIFT algorithm. Biomed Opt Express. 2010;1(1):31–40.CrossRefPubMedPubMedCentral Li H, Lu J, Shi G, Zhang Y. Tracking features in retinal images of adaptive optics confocal scanning laser ophthalmoscope using KLT-SIFT algorithm. Biomed Opt Express. 2010;1(1):31–40.CrossRefPubMedPubMedCentral
35.
Zurück zum Zitat Al-Najdawi N, Tedmori S, Edirisinghe E, Bez H. An automated real-time people tracking system based on KLT Features Detection. Int Arab J Inf Technol. 2012;9:100–107 Al-Najdawi N, Tedmori S, Edirisinghe E, Bez H. An automated real-time people tracking system based on KLT Features Detection. Int Arab J Inf Technol. 2012;9:100–107
36.
Zurück zum Zitat Lin G, Tsai T. A face tracking method using feature point tracking. In: Proceedings of the 2012 International Conference on Information Security and Intelligent Control, 14–16 Aug. 2012. Lin G, Tsai T. A face tracking method using feature point tracking. In: Proceedings of the 2012 International Conference on Information Security and Intelligent Control, 14–16 Aug. 2012.
37.
Zurück zum Zitat Bourel F, Chibelushi CC, Low AA. Robust facial feature tracking. In: Proceedings of the BMVC, 2000. Bourel F, Chibelushi CC, Low AA. Robust facial feature tracking. In: Proceedings of the BMVC, 2000.
38.
Zurück zum Zitat Adelson EH, Anderson CH, Bergen JR, Burt PJ, Ogden JM. Pyramid methods in image processing. RCA Eng. 1984;29(6):33–41. Adelson EH, Anderson CH, Bergen JR, Burt PJ, Ogden JM. Pyramid methods in image processing. RCA Eng. 1984;29(6):33–41.
39.
Zurück zum Zitat Kalal Z, Mikolajczyk K, Matas J. Forward-backward error: Automatic detection of tracking failures. In: Proceedings of the Pattern recognition (ICPR), 2010 20th international conference on, 2010. Kalal Z, Mikolajczyk K, Matas J. Forward-backward error: Automatic detection of tracking failures. In: Proceedings of the Pattern recognition (ICPR), 2010 20th international conference on, 2010.
41.
Zurück zum Zitat Anonymous. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.CrossRef Anonymous. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.CrossRef
43.
Zurück zum Zitat Dini V, Salvo P, Janowska A, Di Francesco F, Barbini A, Romanelli M. Correlation between wound temperature obtained with an infrared camera and clinical wound bed score in venous leg ulcers. Wounds. 2015;27(10):274–8.PubMed Dini V, Salvo P, Janowska A, Di Francesco F, Barbini A, Romanelli M. Correlation between wound temperature obtained with an infrared camera and clinical wound bed score in venous leg ulcers. Wounds. 2015;27(10):274–8.PubMed
Metadaten
Titel
Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia
verfasst von
Jeongmin Kim
Jun Hwan Kwon
Eungjin Kim
Sun Kook Yoo
Cheung-soo Shin
Publikationsdatum
14.11.2018
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0214-4

Weitere Artikel der Ausgabe 4/2019

Journal of Clinical Monitoring and Computing 4/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.