Skip to main content
Literatur
1.
Zurück zum Zitat Pesonen E, Silvasti-Lundell M, Niemi TT, Kivisaari R, Hernesniemi J, Mäkinen MT. (2019) The focus of temperature monitoring with zero-heat-flux technology (3M Bair-Hugger)—a clinical study with patients undergoing craniotomy. J Clin Monit Comp 32 Pesonen E, Silvasti-Lundell M, Niemi TT, Kivisaari R, Hernesniemi J, Mäkinen MT. (2019) The focus of temperature monitoring with zero-heat-flux technology (3M Bair-Hugger)—a clinical study with patients undergoing craniotomy. J Clin Monit Comp 32
2.
Zurück zum Zitat Eshraghi Y, Nasr V, Parra-Sanchez I, Van Duren A, Botham M, Santoscoy T, Sessler DI. An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients. Anesth Analg. 2014;119:543–9.CrossRefPubMed Eshraghi Y, Nasr V, Parra-Sanchez I, Van Duren A, Botham M, Santoscoy T, Sessler DI. An evaluation of a zero-heat-flux cutaneous thermometer in cardiac surgical patients. Anesth Analg. 2014;119:543–9.CrossRefPubMed
3.
Zurück zum Zitat Mäkinen MT, Pesonen A, Jousela I, Päivärinta J, Poikajärvi S, Albäck A, Salminen US, Pesonen E. Novel zero-heat-flux deep body temperature measurement in lower extremity vascular and cardiac surgery. J Cardiothorac Vasc Anesth. 2016;30:973–8.CrossRefPubMed Mäkinen MT, Pesonen A, Jousela I, Päivärinta J, Poikajärvi S, Albäck A, Salminen US, Pesonen E. Novel zero-heat-flux deep body temperature measurement in lower extremity vascular and cardiac surgery. J Cardiothorac Vasc Anesth. 2016;30:973–8.CrossRefPubMed
4.
Zurück zum Zitat Iden T, Horn EP, Bein B, Böhm R, Beese J, Höcker J. Intraoperative temperature monitoring with zero heat flux technology (3M SpotOn sensor) in comparison with sublingual and nasopharyngeal temperature: An observational study. Eur J Anaesthesiol. 2015;32:387–91.CrossRefPubMed Iden T, Horn EP, Bein B, Böhm R, Beese J, Höcker J. Intraoperative temperature monitoring with zero heat flux technology (3M SpotOn sensor) in comparison with sublingual and nasopharyngeal temperature: An observational study. Eur J Anaesthesiol. 2015;32:387–91.CrossRefPubMed
5.
Zurück zum Zitat Boisson M, Alaux A, Kerforne T. Mimoz O, Debaene B, Dahyot-Fizelier C, Frasca D. Intra-operative cutaneous temperature monitoring with zero-heat-flux technique (3M SpotOn) in comparison with oesophageal and arterial temperature: a prospective observational study. Eur J Anaesthesiol. 2018;35:825–30.CrossRefPubMed Boisson M, Alaux A, Kerforne T. Mimoz O, Debaene B, Dahyot-Fizelier C, Frasca D. Intra-operative cutaneous temperature monitoring with zero-heat-flux technique (3M SpotOn) in comparison with oesophageal and arterial temperature: a prospective observational study. Eur J Anaesthesiol. 2018;35:825–30.CrossRefPubMed
6.
Zurück zum Zitat Dahyot-Fizelier C, Lamarche S, Kerforne T, Benard T, Giraud B, Bellier R, Carise E, Frasca D, Mimoz O. Accuracy of zero-heat-flux cutaneous temperature in intensive care adults. Crit Care Med. 2017;45:e715–7.CrossRefPubMed Dahyot-Fizelier C, Lamarche S, Kerforne T, Benard T, Giraud B, Bellier R, Carise E, Frasca D, Mimoz O. Accuracy of zero-heat-flux cutaneous temperature in intensive care adults. Crit Care Med. 2017;45:e715–7.CrossRefPubMed
7.
Zurück zum Zitat Schuhmann MU, Suhr DF, v.Gösseln HH, Bräuer A, Jantzen JP, Samii M. Local brain surface temperature compared to temperatures measured at standard extracranial monitoring sites during posterior fossa surgery. J Neurosurg Anesthesiol. 1999;11:90–5.CrossRefPubMed Schuhmann MU, Suhr DF, v.Gösseln HH, Bräuer A, Jantzen JP, Samii M. Local brain surface temperature compared to temperatures measured at standard extracranial monitoring sites during posterior fossa surgery. J Neurosurg Anesthesiol. 1999;11:90–5.CrossRefPubMed
8.
Zurück zum Zitat Soukup J, Rieger A, Holz C, Miko I, Nemeth N, Menzel M. Temperature gradient between brain tissue and arterial blood mirrors the flow-metabolism relationship in uninjured brain: an experimental study. Acta Anaesthesiol Scand. 2007;51:872–9.CrossRefPubMed Soukup J, Rieger A, Holz C, Miko I, Nemeth N, Menzel M. Temperature gradient between brain tissue and arterial blood mirrors the flow-metabolism relationship in uninjured brain: an experimental study. Acta Anaesthesiol Scand. 2007;51:872–9.CrossRefPubMed
9.
Zurück zum Zitat Camboni D, Philipp A, Schebesch KM, Schmid C. Accuracy of core temperature measurement in deep hypothermic circulatory arrest. Interact Cardiovasc Thorac Surg. 2008;7:922–4.CrossRefPubMed Camboni D, Philipp A, Schebesch KM, Schmid C. Accuracy of core temperature measurement in deep hypothermic circulatory arrest. Interact Cardiovasc Thorac Surg. 2008;7:922–4.CrossRefPubMed
10.
Zurück zum Zitat Henker RA, Brown SD, Marion DW. Comparison of brain temperature with bladder and rectal temperatures in adults with severe head injury. Neurosurgery. 1998;42:1071–5.CrossRefPubMed Henker RA, Brown SD, Marion DW. Comparison of brain temperature with bladder and rectal temperatures in adults with severe head injury. Neurosurgery. 1998;42:1071–5.CrossRefPubMed
11.
Zurück zum Zitat Whitby JD, Dunkin LJ. Cerebral,oesophageal and nasopharyngeal temperatures. Br J Anaesth. 1971;43:673–6.CrossRefPubMed Whitby JD, Dunkin LJ. Cerebral,oesophageal and nasopharyngeal temperatures. Br J Anaesth. 1971;43:673–6.CrossRefPubMed
12.
Zurück zum Zitat Rossi S, Zanier ER, Mauri I, Columbo A, Stocchetti N. Brain temperature, body core temperature, and intracranial pressure in acute cerebral damage. J Neurol Neurosurg Psychiatry. 2001;71:448–54.CrossRefPubMedPubMedCentral Rossi S, Zanier ER, Mauri I, Columbo A, Stocchetti N. Brain temperature, body core temperature, and intracranial pressure in acute cerebral damage. J Neurol Neurosurg Psychiatry. 2001;71:448–54.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Rumana CS, Gopinath SP, Uzura M, Valadka AB, Robertson CS. Brain temperature exceeds systemic temperature in head-injured patients. Crit Care Med. 1998;26:562–7.CrossRefPubMed Rumana CS, Gopinath SP, Uzura M, Valadka AB, Robertson CS. Brain temperature exceeds systemic temperature in head-injured patients. Crit Care Med. 1998;26:562–7.CrossRefPubMed
14.
Zurück zum Zitat Weisend MP, Feeney DM. The relationship between traumatic brain injury-induced changes in brain temperature and behavioral and anatomic outcome. J Neurosurg. 1994;80:120–32.CrossRefPubMed Weisend MP, Feeney DM. The relationship between traumatic brain injury-induced changes in brain temperature and behavioral and anatomic outcome. J Neurosurg. 1994;80:120–32.CrossRefPubMed
15.
Zurück zum Zitat Neeraj B. (2009) Hyperthermia and fever control in brain injury. Crit Care Med 37: 250–257.CrossRef Neeraj B. (2009) Hyperthermia and fever control in brain injury. Crit Care Med 37: 250–257.CrossRef
Metadaten
Titel
Temperature monitoring with zero-heat-flux technology in neurosurgical patients
verfasst von
Matthias Menzel
Anselm Bräuer
Publikationsdatum
09.02.2019
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 5/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00274-3

Weitere Artikel der Ausgabe 5/2019

Journal of Clinical Monitoring and Computing 5/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.