Skip to main content
Erschienen in: Journal of Medical Systems 2/2014

01.02.2014 | Research Article

Multiresolution Image Registration in Digital X-Ray Angiography with Intensity Variation Modeling

verfasst von: Mansour Nejati, Hossein Pourghassem

Erschienen in: Journal of Medical Systems | Ausgabe 2/2014

Einloggen, um Zugang zu erhalten

Abstract

Digital subtraction angiography (DSA) is a widely used technique for visualization of vessel anatomy in diagnosis and treatment. However, due to unavoidable patient motions, both externally and internally, the subtracted angiography images often suffer from motion artifacts that adversely affect the quality of the medical diagnosis. To cope with this problem and improve the quality of DSA images, registration algorithms are often employed before subtraction. In this paper, a novel elastic registration algorithm for registration of digital X-ray angiography images, particularly for the coronary location, is proposed. This algorithm includes a multiresolution search strategy in which a global transformation is calculated iteratively based on local search in coarse and fine sub-image blocks. The local searches are accomplished in a differential multiscale framework which allows us to capture both large and small scale transformations. The local registration transformation also explicitly accounts for local variations in the image intensities which incorporated into our model as a change of local contrast and brightness. These local transformations are then smoothly interpolated using thin-plate spline interpolation function to obtain the global model. Experimental results with several clinical datasets demonstrate the effectiveness of our algorithm in motion artifact reduction.
Literatur
2.
Zurück zum Zitat Meijering, E. H. W., Zuiderveld, K. J., and Viergever, M. A., Image registration for digital subtraction angiography. Int. J. Comput. Vis. 31(2/3):227–246, 1999.CrossRef Meijering, E. H. W., Zuiderveld, K. J., and Viergever, M. A., Image registration for digital subtraction angiography. Int. J. Comput. Vis. 31(2/3):227–246, 1999.CrossRef
3.
Zurück zum Zitat Zitova, B., and Flusser, J., Image registration methods: A survey. Image Vis. Comput. 21(11):977–1000, 2003.CrossRef Zitova, B., and Flusser, J., Image registration methods: A survey. Image Vis. Comput. 21(11):977–1000, 2003.CrossRef
4.
Zurück zum Zitat Brown, L. G., A survey of image registration techniques. ACM Comput. Surv. 24(4):325–276, 1992.CrossRef Brown, L. G., A survey of image registration techniques. ACM Comput. Surv. 24(4):325–276, 1992.CrossRef
5.
Zurück zum Zitat Elsen, V. D., Pol, P. A., and Viergever, E.-J. D., Medical image matching: A review with classification. IEEE Eng. Med. Biol. Magazine 12(1):26–39, 1993.CrossRef Elsen, V. D., Pol, P. A., and Viergever, E.-J. D., Medical image matching: A review with classification. IEEE Eng. Med. Biol. Magazine 12(1):26–39, 1993.CrossRef
6.
Zurück zum Zitat Maintz, J. B. A., and Viergever, M. A., A survey of medical image registration. Med. Image Anal. 2(1):1–36, 1998.CrossRef Maintz, J. B. A., and Viergever, M. A., A survey of medical image registration. Med. Image Anal. 2(1):1–36, 1998.CrossRef
7.
Zurück zum Zitat Hajnal, J. V., Hill, D. L. G., and Hawkes, D. J., Medical image registration. CRS Press, Baton Rouge, Florida, 2001.CrossRef Hajnal, J. V., Hill, D. L. G., and Hawkes, D. J., Medical image registration. CRS Press, Baton Rouge, Florida, 2001.CrossRef
8.
Zurück zum Zitat Cox, G. S., De Jager, G. “Automatic registration of temporal image pairs for digital subtraction angiography,” In: Loew M. H. (ed.), Proceedings of the SPIE, Medical imaging: image processing, vol. 2167, pp. 188–199, Bellingham, WA, 1994. Cox, G. S., De Jager, G. “Automatic registration of temporal image pairs for digital subtraction angiography,” In: Loew M. H. (ed.), Proceedings of the SPIE, Medical imaging: image processing, vol. 2167, pp. 188–199, Bellingham, WA, 1994.
9.
Zurück zum Zitat Nejati, M., Sadri, S., and Amirfattahi, R., “Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline”, BioMed Research International, pp. 1–12, vol. 2013. Nejati, M., Sadri, S., and Amirfattahi, R., “Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline”, BioMed Research International, pp. 1–12, vol. 2013.
10.
Zurück zum Zitat Buzug, T. M., Weese, J., Fassnacht, C., and Lorenz, C., Using an entropy similarity measure to enhance the quality of DSA images with an algorithm based on template matching. In: Höhne, K.-H., and Kikinis, R. (Eds.), VBC’96, Lecture Notes in Computer Science, vol. 1131. Springer, Berlin, pp. 235–240, 1996. Buzug, T. M., Weese, J., Fassnacht, C., and Lorenz, C., Using an entropy similarity measure to enhance the quality of DSA images with an algorithm based on template matching. In: Höhne, K.-H., and Kikinis, R. (Eds.), VBC’96, Lecture Notes in Computer Science, vol. 1131. Springer, Berlin, pp. 235–240, 1996.
11.
Zurück zum Zitat Buzug, T. M., Weese, J., Lorenz, C., and Beil, W., Histogram-based image registration for digital subtraction angiography. In: Del Bimbo, A. (Ed.), ICIAP’97, Lecture Notes in Computer Science, vol. 1311. Springer, Berlin, pp. 380–387, 1997. Buzug, T. M., Weese, J., Lorenz, C., and Beil, W., Histogram-based image registration for digital subtraction angiography. In: Del Bimbo, A. (Ed.), ICIAP’97, Lecture Notes in Computer Science, vol. 1311. Springer, Berlin, pp. 380–387, 1997.
12.
Zurück zum Zitat Buzug, T. M., and Weese, J., Image registration for DSA quality enhancement. Comput. Med. Imaging Graph. 22(2):103–113, 1998.CrossRef Buzug, T. M., and Weese, J., Image registration for DSA quality enhancement. Comput. Med. Imaging Graph. 22(2):103–113, 1998.CrossRef
13.
Zurück zum Zitat Cao, Z., Liu, X., Peng, B., Moon, Y.-S. “DSA image registration based on multiscale Gabor filters and mutual information”. In: Proceedings of the IEEE ICIA’05, Hong Kong and Macau, China, pp. 105–110, 2005. Cao, Z., Liu, X., Peng, B., Moon, Y.-S. “DSA image registration based on multiscale Gabor filters and mutual information”. In: Proceedings of the IEEE ICIA’05, Hong Kong and Macau, China, pp. 105–110, 2005.
14.
Zurück zum Zitat Taleb, N., and Jetto, L., Image registration for applications in digital subtraction angiography. Control. Eng. Pract. 6(2):227–238, 1998.CrossRef Taleb, N., and Jetto, L., Image registration for applications in digital subtraction angiography. Control. Eng. Pract. 6(2):227–238, 1998.CrossRef
15.
Zurück zum Zitat Bentoutou, Y., Taleb, N., Chikr El Mezouar, M., Taleb, M., and Jetto, L., An invariant approach for image registration in digital subtraction angiography. Pattern Recogn. 35(12):2853–2865, 2002.CrossRefMATH Bentoutou, Y., Taleb, N., Chikr El Mezouar, M., Taleb, M., and Jetto, L., An invariant approach for image registration in digital subtraction angiography. Pattern Recogn. 35(12):2853–2865, 2002.CrossRefMATH
16.
Zurück zum Zitat Bentoutou, Y., and Taleb, N., Automatic extraction of control points for digital subtraction angiography image enhancement. IEEE Trans. Nucl. Sci. 52(1):238–246, 2005.CrossRef Bentoutou, Y., and Taleb, N., Automatic extraction of control points for digital subtraction angiography image enhancement. IEEE Trans. Nucl. Sci. 52(1):238–246, 2005.CrossRef
17.
Zurück zum Zitat Bentoutou, Y., and Taleb, N., A 3-D space-time motion detection for an invariant image registration approach in digital subtraction angiography. Comput. Vis. Image Underst. 97(1):30–50, 2005.CrossRef Bentoutou, Y., and Taleb, N., A 3-D space-time motion detection for an invariant image registration approach in digital subtraction angiography. Comput. Vis. Image Underst. 97(1):30–50, 2005.CrossRef
18.
Zurück zum Zitat Meijering, E. H. W., Niessen, W. J., and Viergever, M. A., Retrospective motion correction in digital subtraction angiography: a review. IEEE Trans. Med. Imaging 18(1):2–21, 1999.CrossRef Meijering, E. H. W., Niessen, W. J., and Viergever, M. A., Retrospective motion correction in digital subtraction angiography: a review. IEEE Trans. Med. Imaging 18(1):2–21, 1999.CrossRef
19.
Zurück zum Zitat Ping, L., Hong, N., Ye, S. “An efficient method for image registration in DSA,” In: Proceedings of the ISISE’08, Shanghai, China, vol. 2, pp. 551–554, 2008. Ping, L., Hong, N., Ye, S. “An efficient method for image registration in DSA,” In: Proceedings of the ISISE’08, Shanghai, China, vol. 2, pp. 551–554, 2008.
20.
Zurück zum Zitat Nejati, M., Amirfattahi, R., Sadri, S.“A fast image registration algorithm for digital subtraction angiography”, In: Proceedings of 17th Iranian Conference of Biomedical Engineering (ICBME2010), Isfahan, Iran, pp. 1–4, November 2010. Nejati, M., Amirfattahi, R., Sadri, S.“A fast image registration algorithm for digital subtraction angiography”, In: Proceedings of 17th Iranian Conference of Biomedical Engineering (ICBME2010), Isfahan, Iran, pp. 1–4, November 2010.
21.
Zurück zum Zitat Chu, Y., Bai, N., Ji, Z., Chen, S., Mou, X. “Registration for DSA image using triangle grid and spatial transformation based on stretching”, In: Proceedings of the 8th International Conference on Signal Processing, Beijing, China, 16–20 Nov. 2006. Chu, Y., Bai, N., Ji, Z., Chen, S., Mou, X. “Registration for DSA image using triangle grid and spatial transformation based on stretching”, In: Proceedings of the 8th International Conference on Signal Processing, Beijing, China, 16–20 Nov. 2006.
22.
Zurück zum Zitat Wang, J., Zhang, J. Q. “An iterative refinement DSA image registration algorithm using structural image quality measure”, In: Proceedings of the 5th IIH-MSP, Kyoto, Japan, pp. 973–976, 2009. Wang, J., Zhang, J. Q. “An iterative refinement DSA image registration algorithm using structural image quality measure”, In: Proceedings of the 5th IIH-MSP, Kyoto, Japan, pp. 973–976, 2009.
23.
Zurück zum Zitat Yang, J., Wang, Y., Tang, S., Zhou, S., Liu, Y., and Chen, W., Multiresolution elastic registration of X-ray angiography images using thin-plate spline. IEEE Trans. Nucl. Sci. 54(1):152–166, 2007.CrossRef Yang, J., Wang, Y., Tang, S., Zhou, S., Liu, Y., and Chen, W., Multiresolution elastic registration of X-ray angiography images using thin-plate spline. IEEE Trans. Nucl. Sci. 54(1):152–166, 2007.CrossRef
24.
Zurück zum Zitat Nejati, M., Pourghassem, H. “Multiresolution search strategy for elastic registration of x-ray angiography images”, In Proceedings of International Conference on Intelligent Computation and Bio-Medical Instrumentation (ICBMI 2011), pp. 216–219, Wuhan, China, 14–17 Dec. 2011. Nejati, M., Pourghassem, H. “Multiresolution search strategy for elastic registration of x-ray angiography images”, In Proceedings of International Conference on Intelligent Computation and Bio-Medical Instrumentation (ICBMI 2011), pp. 216–219, Wuhan, China, 14–17 Dec. 2011.
25.
Zurück zum Zitat Periaswamy, S., and Farid, H., Elastic registration in the Presence of Intensity Variations. IEEE Trans. Med. Imaging 22(7):865–874, 2003.CrossRef Periaswamy, S., and Farid, H., Elastic registration in the Presence of Intensity Variations. IEEE Trans. Med. Imaging 22(7):865–874, 2003.CrossRef
26.
Zurück zum Zitat Bookstein, F. L., Principal warps: thin-plate splines and the decomposition of deformations. IEEE Transact. Pattern Anal. Mach. Intell. 11(6):567–585, 1989.CrossRefMATH Bookstein, F. L., Principal warps: thin-plate splines and the decomposition of deformations. IEEE Transact. Pattern Anal. Mach. Intell. 11(6):567–585, 1989.CrossRefMATH
27.
Zurück zum Zitat Farid, H., Simoncelli, E. P.“Optimally rotation-equivariant directional derivative kernels”, In Proceedings of International Conference on Computer Analysis of Images and Patterns, pp. 207–214, Berlin, Germany, Sept. 1997. Farid, H., Simoncelli, E. P.“Optimally rotation-equivariant directional derivative kernels”, In Proceedings of International Conference on Computer Analysis of Images and Patterns, pp. 207–214, Berlin, Germany, Sept. 1997.
28.
Zurück zum Zitat Powell, M. J. D., An efficient method for finding the minimum of a function of several variables without calculating derivatives. Comput. J. 7(2):155–162, 1964.CrossRefMATHMathSciNet Powell, M. J. D., An efficient method for finding the minimum of a function of several variables without calculating derivatives. Comput. J. 7(2):155–162, 1964.CrossRefMATHMathSciNet
Metadaten
Titel
Multiresolution Image Registration in Digital X-Ray Angiography with Intensity Variation Modeling
verfasst von
Mansour Nejati
Hossein Pourghassem
Publikationsdatum
01.02.2014
Verlag
Springer US
Erschienen in
Journal of Medical Systems / Ausgabe 2/2014
Print ISSN: 0148-5598
Elektronische ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-014-0010-8

Weitere Artikel der Ausgabe 2/2014

Journal of Medical Systems 2/2014 Zur Ausgabe