Ambulatory screening tool for sleep apnea: analyzing a single-lead electrocardiogram signal (ECG)

verfasst von: Solveig Magnusdottir, Hugi Hilmisson

Erschienen in: Sleep and Breathing | Ausgabe 2/2018

Einloggen, um Zugang zu erhalten

Abstract

Study objective

The goal was to determine the utility and accuracy of automated analysis of single-lead electrocardiogram (ECG) data using two algorithms, cardiopulmonary coupling (CPC), and cyclic variation of heart rate (CVHR) to identify sleep apnea (SA).

Methods

The CPC-CVHR algorithms were applied to identify SA by analyzing ECG from diagnostic polysomnography (PSG) from 47 subjects. The studies were rescored according to updated AASM scoring rules, both manually by a certified technologist and using an FDA-approved automated scoring software, Somnolyzer (Philips Inc., Monroeville, PA). The CPC+CVHR output of Sleep Quality Index (SQI), Sleep Apnea Indicator (SAI), elevated low frequency coupling broadband (eLFCBB) and elevated low frequency coupling narrow-band (eLFCNB) were compared to the manual and automated scoring of apnea hypopnea index (AHI).

Results

A high degree of agreement was noted between the CPC-CVHR against both the manually rescored AHI and the computerized scored AHI to identify patients with moderate and severe sleep apnea (AHI > 15). The combined CPC+CVHR algorithms, when compared to the manually scored PSG output presents sensitivity 89%, specificity 79%, agreement 85%, PPV (positive predictive value) 0.86 and NPV (negative predictive value) 0.83, and substantial Kappa 0.70. Comparing the output of the automated scoring software to the manual scoring demonstrated sensitivity 93%, specificity 79%, agreement 87%, PPV 0.87, NPV 0.88, and substantial Kappa 0.74.

Conclusion

The CPC+CVHR technology performed as accurately as the automated scoring software to identify patients with moderate to severe SA, demonstrating a clinically powerful tool that can be implemented in various clinical settings to identify patients at risk for SA.

Trial registration

NCT01234077.
Literatur
3.
Zurück zum Zitat Young T, Finn L, Peppard PE et al (2008) Sleep disordered breathing and mortality: eighteen-year follow-up of the Wisconsin sleep cohorts. Sleep 31:1071–1078CrossRefPubMedPubMedCentral Young T, Finn L, Peppard PE et al (2008) Sleep disordered breathing and mortality: eighteen-year follow-up of the Wisconsin sleep cohorts. Sleep 31:1071–1078CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Thomas RJ (2016) Cardiopulmonary coupling sleep spectrograms. In: Kryger MH, Roth T, Dement WC (eds) Principles and practice of sleep medicine, 6rd edn. Elsevier, Inc., Philadelphia, pp 1615–1623 Thomas RJ (2016) Cardiopulmonary coupling sleep spectrograms. In: Kryger MH, Roth T, Dement WC (eds) Principles and practice of sleep medicine, 6rd edn. Elsevier, Inc., Philadelphia, pp 1615–1623
13.
Zurück zum Zitat Guilleminault C, Connolly S, Winkle R, Melvin K, Tilkian A (1984) Cyclical variation of the heart rate in sleep apnea syndrome: mechanisms, and usefulness of 24h electrocardiography as a screening technique. Lancet 1(8369):126–131CrossRefPubMed Guilleminault C, Connolly S, Winkle R, Melvin K, Tilkian A (1984) Cyclical variation of the heart rate in sleep apnea syndrome: mechanisms, and usefulness of 24h electrocardiography as a screening technique. Lancet 1(8369):126–131CrossRefPubMed
15.
Zurück zum Zitat Whitney CW, Gottlieb DJ, Redline S et al (1998) Reliability of scoring respiratory disturbance indices and sleep staging. Sleep 21(7):749–757CrossRefPubMed Whitney CW, Gottlieb DJ, Redline S et al (1998) Reliability of scoring respiratory disturbance indices and sleep staging. Sleep 21(7):749–757CrossRefPubMed
18.
Zurück zum Zitat Julious SA (2005) Sample size of 12 per group rule of thumb for a pilot study. Pharm Stats 4(4):287–291CrossRef Julious SA (2005) Sample size of 12 per group rule of thumb for a pilot study. Pharm Stats 4(4):287–291CrossRef
19.
Zurück zum Zitat Iber C, Ancoli-Israel S, Chesson AL Jr et al (2007) The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, 1st edn. American Academy of Sleep Medicine, Westchester Iber C, Ancoli-Israel S, Chesson AL Jr et al (2007) The AASM manual for the scoring of sleep and associated events: rules, terminology and technical specifications, 1st edn. American Academy of Sleep Medicine, Westchester
21.
Zurück zum Zitat Thomas RJ, Mietus JE, Peng CK, Gilmarin G, Daly RW, Goldberger AL, Gottlie DJ (2007) Differentiation obstructive from central and complex sleep apnea using an automated electrocardiogram-based method. Sleep 30(12):1756–1759CrossRefPubMedPubMedCentral Thomas RJ, Mietus JE, Peng CK, Gilmarin G, Daly RW, Goldberger AL, Gottlie DJ (2007) Differentiation obstructive from central and complex sleep apnea using an automated electrocardiogram-based method. Sleep 30(12):1756–1759CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Lee WH, Hong SN, Kim HJ, Rhee CS, Lee CH, Yoon IY, Kim JW (2016) A Comparison of different success definitions in non-continuous positive airway pressure treatment for obstructive sleep apnea using cardiopulmonary coupling. J Clin Sleep Med 1:35–41. https://doi.org/10.5664/jcsm.5388 CrossRef Lee WH, Hong SN, Kim HJ, Rhee CS, Lee CH, Yoon IY, Kim JW (2016) A Comparison of different success definitions in non-continuous positive airway pressure treatment for obstructive sleep apnea using cardiopulmonary coupling. J Clin Sleep Med 1:35–41. https://​doi.​org/​10.​5664/​jcsm.​5388 CrossRef
29.
Zurück zum Zitat StataCorp (2011) Stata statistical software: release 12. StataCorp LP, College Station StataCorp (2011) Stata statistical software: release 12. StataCorp LP, College Station
34.
Zurück zum Zitat Quadri S, Drake C, Hudgel DV (2009) Improvement of idiopathic central sleep apnea with zolpidem. J Clin Sleep Med 5:122–129PubMedPubMedCentral Quadri S, Drake C, Hudgel DV (2009) Improvement of idiopathic central sleep apnea with zolpidem. J Clin Sleep Med 5:122–129PubMedPubMedCentral
35.
Zurück zum Zitat Hanly PJ, Millar TW, Steljes DG, Baert R, Frais MA, Kryger MH (1989) Respiration and abnormal sleep in patients with congestive heart failure. Chest 96:480–488CrossRefPubMed Hanly PJ, Millar TW, Steljes DG, Baert R, Frais MA, Kryger MH (1989) Respiration and abnormal sleep in patients with congestive heart failure. Chest 96:480–488CrossRefPubMed
36.
Zurück zum Zitat Walker JM, Farney RJ, Rhondeau SM et al (2007) Chronic opioid use is a risk factor for the development of central sleep apnea and ataxic breathing. J Clin Sleep Med: JFCS: Off Publ Am Acad Sleep Med 3:455–461 Walker JM, Farney RJ, Rhondeau SM et al (2007) Chronic opioid use is a risk factor for the development of central sleep apnea and ataxic breathing. J Clin Sleep Med: JFCS: Off Publ Am Acad Sleep Med 3:455–461
37.
Zurück zum Zitat Thomas RJ, Tamisier R, Boucher J et al (2013) Nocturnal hypoxia exposure with simulated altitude for 14 days does not significantly alter working memory or vigilance in humans. Sleep 30:1195–1203CrossRef Thomas RJ, Tamisier R, Boucher J et al (2013) Nocturnal hypoxia exposure with simulated altitude for 14 days does not significantly alter working memory or vigilance in humans. Sleep 30:1195–1203CrossRef
39.
Zurück zum Zitat Alshaer H, Bradley TD (2016) Positional sleep apnea is a cause of inter-night variability in the apnea hypopnea index. Am J Respir Crit Care Med 193: Meeting Abstracts:A2537 Alshaer H, Bradley TD (2016) Positional sleep apnea is a cause of inter-night variability in the apnea hypopnea index. Am J Respir Crit Care Med 193: Meeting Abstracts:A2537
Metadaten
Titel
Ambulatory screening tool for sleep apnea: analyzing a single-lead electrocardiogram signal (ECG)
verfasst von
Solveig Magnusdottir
Hugi Hilmisson
Publikationsdatum
07.09.2017
Verlag
Springer International Publishing
Erschienen in
Sleep and Breathing / Ausgabe 2/2018
Print ISSN: 1520-9512
Elektronische ISSN: 1522-1709
DOI
https://doi.org/10.1007/s11325-017-1566-6

Weitere Artikel der Ausgabe 2/2018

Sleep and Breathing 2/2018 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.