Skip to main content
Erschienen in: La radiologia medica 6/2015

01.06.2015 | MEDICAL PHYSICS

Cumulative radiation dose and radiation risk from medical imaging in patients subjected to endovascular aortic aneurysm repair

verfasst von: Marco Brambilla, Paolo Cerini, Domenico Lizio, Luca Vigna, Alessandro Carriero, Rita Fossaceca

Erschienen in: La radiologia medica | Ausgabe 6/2015

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study was undertaken to quantify the cumulative effective dose (CED) of radiation and the dose to relevant organs in endovascular aortic repair (EVAR) patients, to assess radiation risks and to evaluate the clinical usefulness of multi-detector computed tomography (MDCT) follow-up.

Materials and methods

The radiation exposures were obtained from 71 consecutive EVAR patients with a follow-up duration ≥1 year. Dose calculations were performed on an individual basis and expressed as effective doses and organ doses. Radiation risk was expressed as risk of exposure-induced death (%), using the biological effects of ionising radiation model. Two radiologists independently assessed the images for abdominal aortic aneurysm expansion without endoleaks, thrombotic occlusion, endoleaks and device migration. They first reviewed arterial imaging alone and subsequently added non-contrast and delayed phases to determine the overall performance.

Results

The median total CED and annual CED were 224 and 104 mSv per patient-year. The median cumulative organ doses were 191, 205, 230, 269 and 271 mSv for lung, bone marrow, liver, colon and stomach, respectively. The average risk of exposure-induced death was 0.8 % (i.e., odds 1 in 130). All the findings related to EVAR outcome and leading to a change in patient management were visible during the arterial phase of the MDCT angiography. Omission of the unenhanced scan and the venous phase of the MDCT angiography would have led to a significant reduction of about 60 % of the associated MDCT radiation exposure in a single patient.

Conclusions

EVAR patients received high radiation doses and the excess cancer risk attributable to radiation exposure is not negligible. The unenhanced scan and the venous phase of the MDCT angiography could have been omitted without compromising the utility of the examination and with a significant reduction of doses and associated risks.
Literatur
1.
Zurück zum Zitat EVAR trial participants (2005) Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised trial. Lancet 365:2179–2186CrossRef EVAR trial participants (2005) Endovascular aneurysm repair versus open repair in patients with abdominal aortic aneurysm (EVAR trial 1): randomised trial. Lancet 365:2179–2186CrossRef
2.
Zurück zum Zitat EVAR trial participants (2005) Endovascular aneurysm repair and outcome in patients unfit for open repair of abdominal aortic aneurysm (EVAR trial 2): randomised controlled trial. Lancet 365:2187–2192CrossRef EVAR trial participants (2005) Endovascular aneurysm repair and outcome in patients unfit for open repair of abdominal aortic aneurysm (EVAR trial 2): randomised controlled trial. Lancet 365:2187–2192CrossRef
3.
Zurück zum Zitat Varu VN, Greenberg JI, Lee JT (2013) Improved efficiency and safety for EVAR with utilization of a hybrid room. Eur J Vasc Endovasc Surg 46:675–679CrossRefPubMed Varu VN, Greenberg JI, Lee JT (2013) Improved efficiency and safety for EVAR with utilization of a hybrid room. Eur J Vasc Endovasc Surg 46:675–679CrossRefPubMed
4.
Zurück zum Zitat Kalef-Ezra JA, Karavasilis S, Kouvelos G et al (2011) Endovascular abdominal aortic aneurysm repair: methods of radiological risk reduction. J Cardiovasc Surg 52:769–778 Kalef-Ezra JA, Karavasilis S, Kouvelos G et al (2011) Endovascular abdominal aortic aneurysm repair: methods of radiological risk reduction. J Cardiovasc Surg 52:769–778
5.
Zurück zum Zitat Maurel B, Sobocinski J, Perini P et al (2012) Evaluation of radiation during EVAR performed on a mobile C-arm. Eur J Vasc Endovasc Surg 43:16–21CrossRefPubMed Maurel B, Sobocinski J, Perini P et al (2012) Evaluation of radiation during EVAR performed on a mobile C-arm. Eur J Vasc Endovasc Surg 43:16–21CrossRefPubMed
6.
Zurück zum Zitat Fossaceca R, Brambilla M, Guzzardi G et al (2012) The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair. Eur Radiol 22:2424–2431CrossRefPubMed Fossaceca R, Brambilla M, Guzzardi G et al (2012) The impact of radiological equipment on patient radiation exposure during endovascular aortic aneurysm repair. Eur Radiol 22:2424–2431CrossRefPubMed
7.
Zurück zum Zitat Buth J, Laheij RJF: On behalf of the EUROSTAR collaborators (2000) Early complications and endoleaks after endovascular abdominal aortic aneurysm repair report of a multicenter study. J Vasc Surg 31:134–146 Buth J, Laheij RJF: On behalf of the EUROSTAR collaborators (2000) Early complications and endoleaks after endovascular abdominal aortic aneurysm repair report of a multicenter study. J Vasc Surg 31:134–146
8.
Zurück zum Zitat Verhoeven EL, Oikonomou K, Ventin FC et al (2011) Is it time to eliminate CT after EVAR as routine follow-up? J Cardiovasc Surg 52:193–198 Verhoeven EL, Oikonomou K, Ventin FC et al (2011) Is it time to eliminate CT after EVAR as routine follow-up? J Cardiovasc Surg 52:193–198
9.
Zurück zum Zitat Dias NV, Riva L, Ivancev K et al (2009) Is there a benefit from frequent CT follow-up after EVAR? Eur J Vasc Endovasc Surg 37:425–430CrossRefPubMed Dias NV, Riva L, Ivancev K et al (2009) Is there a benefit from frequent CT follow-up after EVAR? Eur J Vasc Endovasc Surg 37:425–430CrossRefPubMed
10.
Zurück zum Zitat Manning BJ, O’Neill SM, Haider SN et al (2009) Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography. J Vasc Surg 49:60–65CrossRefPubMed Manning BJ, O’Neill SM, Haider SN et al (2009) Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography. J Vasc Surg 49:60–65CrossRefPubMed
11.
Zurück zum Zitat Ten Bosch JA, Rouwet EV, Peters CT et al (2010) Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair. J Vasc Interv Radiol 21:638–643CrossRefPubMed Ten Bosch JA, Rouwet EV, Peters CT et al (2010) Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair. J Vasc Interv Radiol 21:638–643CrossRefPubMed
12.
Zurück zum Zitat Iezzi R, Cotroneo AR, Giammarino A et al (2011) Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair. Eur J Radiol 79:21–28CrossRefPubMed Iezzi R, Cotroneo AR, Giammarino A et al (2011) Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair. Eur J Radiol 79:21–28CrossRefPubMed
13.
Zurück zum Zitat Bley TA, Chase PJ, Reeder SB et al (2009) Endovascular abdominal aortic aneurysm repair: nonenhanced volumetric CT for follow-up. Radiology 253:253–262CrossRefPubMed Bley TA, Chase PJ, Reeder SB et al (2009) Endovascular abdominal aortic aneurysm repair: nonenhanced volumetric CT for follow-up. Radiology 253:253–262CrossRefPubMed
14.
Zurück zum Zitat Weerakkody RA, Walsh SR, Cousins C et al (2008) Radiation exposure during endovascular aneurysm repair. Br J Surg 95:699–702CrossRefPubMed Weerakkody RA, Walsh SR, Cousins C et al (2008) Radiation exposure during endovascular aneurysm repair. Br J Surg 95:699–702CrossRefPubMed
15.
Zurück zum Zitat Kalef-Ezra JA, Karavasilis S, Ziogas D et al (2009) Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair. J Vasc Surg 49:283–287CrossRefPubMed Kalef-Ezra JA, Karavasilis S, Ziogas D et al (2009) Radiation burden of patients undergoing endovascular abdominal aortic aneurysm repair. J Vasc Surg 49:283–287CrossRefPubMed
16.
Zurück zum Zitat Jones C, Badger SA, Boyd CS et al (2010) The impact of radiation dose exposure during endovascular aneurysm repair on patient safety. J Vasc Surg 52:298–302CrossRefPubMed Jones C, Badger SA, Boyd CS et al (2010) The impact of radiation dose exposure during endovascular aneurysm repair on patient safety. J Vasc Surg 52:298–302CrossRefPubMed
17.
Zurück zum Zitat Mettler FA, Huda W, Yoshizumi TT et al (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–263CrossRefPubMed Mettler FA, Huda W, Yoshizumi TT et al (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–263CrossRefPubMed
18.
Zurück zum Zitat Jones DG, Wall BF (1985) Organ doses from medical X-ray examinations calculated using Monte Carlo techniques. National Radiological Protection Board, Chilton Jones DG, Wall BF (1985) Organ doses from medical X-ray examinations calculated using Monte Carlo techniques. National Radiological Protection Board, Chilton
20.
Zurück zum Zitat The 2007 recommendations of the International Commission on Radiological Protection: ICRP publication 103. Ann ICRP 37(2–4):1–332 The 2007 recommendations of the International Commission on Radiological Protection: ICRP publication 103. Ann ICRP 37(2–4):1–332
21.
Zurück zum Zitat Rampado O, Marchisio F, Izzo A et al (2009) Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom. Eur Radiol 72:181–187CrossRef Rampado O, Marchisio F, Izzo A et al (2009) Effective dose and image quality evaluations of an automatic CT tube current modulation system with an anthropomorphic phantom. Eur Radiol 72:181–187CrossRef
22.
Zurück zum Zitat Smith-Bindman R, Lipson J, Marcus R et al (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169:2078–2086CrossRefPubMed Smith-Bindman R, Lipson J, Marcus R et al (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169:2078–2086CrossRefPubMed
23.
Zurück zum Zitat Fazel R, Krumholtz HM, Wang Y et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Eng J Med 361:849–857CrossRef Fazel R, Krumholtz HM, Wang Y et al (2009) Exposure to low-dose ionizing radiation from medical imaging procedures. N Eng J Med 361:849–857CrossRef
24.
Zurück zum Zitat Committee to assess health risks from exposure to low levels of ionizing radiation (2006) Health risks from exposure to low levels of ionizing radiation. BEIR VII: Phase 2. National Academies Press, Washington DC Committee to assess health risks from exposure to low levels of ionizing radiation (2006) Health risks from exposure to low levels of ionizing radiation. BEIR VII: Phase 2. National Academies Press, Washington DC
26.
Zurück zum Zitat Brambilla M, De Mauri A, Leva L et al (2013) Cumulative radiation dose from medical imaging in chronic adult patients. Am J Med 126:480–486CrossRefPubMed Brambilla M, De Mauri A, Leva L et al (2013) Cumulative radiation dose from medical imaging in chronic adult patients. Am J Med 126:480–486CrossRefPubMed
27.
Zurück zum Zitat The 2007 recommendations of the international commission on radiological protection: ICRP publication 103. Ann ICRP 37(2–4):1–332 The 2007 recommendations of the international commission on radiological protection: ICRP publication 103. Ann ICRP 37(2–4):1–332
28.
Zurück zum Zitat Motaganahalli R, Martin A, Feliciano B et al (2012) Estimating the risk of solid organ malignancy in patients undergoing routine computed tomography scans after endovascular aneurysm repair. J Vasc Surg 56:929–937CrossRefPubMed Motaganahalli R, Martin A, Feliciano B et al (2012) Estimating the risk of solid organ malignancy in patients undergoing routine computed tomography scans after endovascular aneurysm repair. J Vasc Surg 56:929–937CrossRefPubMed
29.
Zurück zum Zitat Hendee WR (2013) Policy statement of the international organization for medical physics. Radiology 267:326–327CrossRefPubMed Hendee WR (2013) Policy statement of the international organization for medical physics. Radiology 267:326–327CrossRefPubMed
30.
Zurück zum Zitat Stavropoulos SW, Charagundla SR (2007) Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology 243:641–655CrossRefPubMed Stavropoulos SW, Charagundla SR (2007) Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology 243:641–655CrossRefPubMed
31.
Zurück zum Zitat Stavropoulos SW, Clark TW, Carpenter JP et al (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 16:663–667CrossRefPubMed Stavropoulos SW, Clark TW, Carpenter JP et al (2005) Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms. J Vasc Interv Radiol 16:663–667CrossRefPubMed
32.
Zurück zum Zitat Teutelink A, Muhs BE, Vincken KL et al (2007) Use of dynamic computed tomography to evaluate pre- and postoperative aortic changes in AAA patients undergoing endovascular aneurysm repair. J Endovasc Ther 14:44–49CrossRefPubMed Teutelink A, Muhs BE, Vincken KL et al (2007) Use of dynamic computed tomography to evaluate pre- and postoperative aortic changes in AAA patients undergoing endovascular aneurysm repair. J Endovasc Ther 14:44–49CrossRefPubMed
33.
Zurück zum Zitat Iezzi R, Santoro M, Dattesi R et al (2012) Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR). Insights Imaging 3:313–321CrossRefPubMedCentralPubMed Iezzi R, Santoro M, Dattesi R et al (2012) Multi-detector CT angiographic imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair (EVAR). Insights Imaging 3:313–321CrossRefPubMedCentralPubMed
34.
Zurück zum Zitat Stolzmann P, Frauenfelder T, Pfammatter T et al (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691CrossRefPubMed Stolzmann P, Frauenfelder T, Pfammatter T et al (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691CrossRefPubMed
35.
Zurück zum Zitat Bobadilla JL, Suwanabol PA, Reeder SB et al (2013) Clinical implications of non-contrast-enhanced computed tomography for follow-up after endovascular abdominal aortic aneurysm repair. Ann Vasc Surg 27:1042–1048CrossRefPubMed Bobadilla JL, Suwanabol PA, Reeder SB et al (2013) Clinical implications of non-contrast-enhanced computed tomography for follow-up after endovascular abdominal aortic aneurysm repair. Ann Vasc Surg 27:1042–1048CrossRefPubMed
36.
Zurück zum Zitat Iezzi R, Cotroneo AR, Filippone A et al (2008) Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks. J Comput Assist Tomogr 32:609–615CrossRefPubMed Iezzi R, Cotroneo AR, Filippone A et al (2008) Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks. J Comput Assist Tomogr 32:609–615CrossRefPubMed
37.
Zurück zum Zitat Iezzi R, Cotroneo AR, Filippone A et al (2006) Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? Radiology 241:915–921CrossRefPubMed Iezzi R, Cotroneo AR, Filippone A et al (2006) Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? Radiology 241:915–921CrossRefPubMed
38.
Zurück zum Zitat Ghetti C, Ortenzia O, Serreli G (2012) CT iterative reconstruction in image space: a phantom study. Phys Med 28:161–165CrossRefPubMed Ghetti C, Ortenzia O, Serreli G (2012) CT iterative reconstruction in image space: a phantom study. Phys Med 28:161–165CrossRefPubMed
39.
Zurück zum Zitat Mirza TA, Karthikesalingam A, Jackson D et al (2010) Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: systematic review and bivariate meta-analysis. Eur J Vasc Endovasc Surg 39:418–428CrossRefPubMed Mirza TA, Karthikesalingam A, Jackson D et al (2010) Duplex ultrasound and contrast-enhanced ultrasound versus computed tomography for the detection of endoleak after EVAR: systematic review and bivariate meta-analysis. Eur J Vasc Endovasc Surg 39:418–428CrossRefPubMed
40.
Zurück zum Zitat Henao EA, Hodge MD, Felkai DD et al (2006) Contrast-enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 43:259–264CrossRefPubMed Henao EA, Hodge MD, Felkai DD et al (2006) Contrast-enhanced Duplex surveillance after endovascular abdominal aortic aneurysm repair: improved efficacy using a continuous infusion technique. J Vasc Surg 43:259–264CrossRefPubMed
41.
Zurück zum Zitat Resta EC, Secchi F, Giardino A et al (2013) Non-contrast MR imaging for detecting endoleak after abdominal endovascular aortic repair. Int J Cardiovasc Imaging 29:229–235CrossRefPubMed Resta EC, Secchi F, Giardino A et al (2013) Non-contrast MR imaging for detecting endoleak after abdominal endovascular aortic repair. Int J Cardiovasc Imaging 29:229–235CrossRefPubMed
Metadaten
Titel
Cumulative radiation dose and radiation risk from medical imaging in patients subjected to endovascular aortic aneurysm repair
verfasst von
Marco Brambilla
Paolo Cerini
Domenico Lizio
Luca Vigna
Alessandro Carriero
Rita Fossaceca
Publikationsdatum
01.06.2015
Verlag
Springer Milan
Erschienen in
La radiologia medica / Ausgabe 6/2015
Print ISSN: 0033-8362
Elektronische ISSN: 1826-6983
DOI
https://doi.org/10.1007/s11547-014-0485-x

Weitere Artikel der Ausgabe 6/2015

La radiologia medica 6/2015 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.