Abstract

Purpose

Conventional positron emission tomography can be used only preoperatively to identify lymph node metastases, and hence, these growths are difficult to locate intraoperatively. Previously, an intraoperative laparoscopic coincidence imaging system, with an external fixed detector array and a detector probe that can be moved and inserted into the stomach, was proposed to identify lymph node metastases during stomach cancer surgery. This paper proposes a prototype detector for this system.

Methods

GAGG:Ce (Gd3Al2Ga3O12:Ce) scintillator crystals, one to one coupled with silicon photomultipliers (SiPMs), were used to identify 511 keV photons. An optical tracking system followed the position and orientation of the movable detector. SiPM outputs were read out by time-over-threshold (TOT)-based application-specific integrated circuits, which converted the electrical charges into digital pulses. To identify the arrival time, channel number, and pulse width, which indicate the energy information of each TOT output, a data acquisition system was developed based on a field-programmable gate array.

Results

The spatial resolution of the reconstructed images in lateral direction was better than 7 mm, but that of depth direction was limited, owing to inadequate projections. The prototype successfully reconstructed 44 kBq 18F-fluorodeoxyglucose sources during a 2-min scan.

Conclusion

We developed a prototype detector for an intraoperative laparoscopic coincidence imaging system. The prototype detector was evaluated successfully, and the produced images were similar to those obtained in the simulation results, thereby suggesting that this method offers a new possibility of imaging lymph node metastases intraoperatively.
Literatur
2.
Zurück zum Zitat Okumura Y, Aikou S, Onoyama H, Jinbo K, Yamagata Y, Mori K, Yamashita H, Nomura S, Takahashi M, Koyama K, Momose T, Abe H, Matsusaka K, Ushiku T, Fukayama M, Seto Y (2015) Evaluation of 18F-FDG uptake for detecting lymph node metastasis of gastric cancer: a prospective pilot study for one-to-one comparison of radiation dose and pathological findings. World J Surg Oncol 13:327. https://doi.org/10.1186/s12957-015-0743-yCrossRefPubMedPubMedCentral Okumura Y, Aikou S, Onoyama H, Jinbo K, Yamagata Y, Mori K, Yamashita H, Nomura S, Takahashi M, Koyama K, Momose T, Abe H, Matsusaka K, Ushiku T, Fukayama M, Seto Y (2015) Evaluation of 18F-FDG uptake for detecting lymph node metastasis of gastric cancer: a prospective pilot study for one-to-one comparison of radiation dose and pathological findings. World J Surg Oncol 13:327. https://​doi.​org/​10.​1186/​s12957-015-0743-yCrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Wendler T, Herrmann K, Schnelzer A, Lasser T, Traub J, Kutter O, Ehlerding A, Scheidhauer K, Schuster T, Kiechle M, Schwaiger M, Navab N, Ziegler SI, Buck AK (2010) First demonstration of 3-D lymphatic mapping in breast cancer using freehand SPECT. Eur J Nucl Med Mol Imaging 37:1452–1461. https://doi.org/10.1007/s00259-010-1430-4CrossRefPubMed Wendler T, Herrmann K, Schnelzer A, Lasser T, Traub J, Kutter O, Ehlerding A, Scheidhauer K, Schuster T, Kiechle M, Schwaiger M, Navab N, Ziegler SI, Buck AK (2010) First demonstration of 3-D lymphatic mapping in breast cancer using freehand SPECT. Eur J Nucl Med Mol Imaging 37:1452–1461. https://​doi.​org/​10.​1007/​s00259-010-1430-4CrossRefPubMed
11.
Zurück zum Zitat Aubry N, Auffray E, Mimoun FB, Brillouet N, Bugalho R, Charbon E, Charles O, Cortinovis D, Courday P, Cserkaszky A, Damon C, Doroud K, Fischer J-M, Fornaro G, Fourmigue J-M, Frisch B, Fürst B, Gardiazabal J, Gadow K, Garutti E et al (2013) EndoTOFPET-US: a novel multimodal tool for endoscopy and positron emission tomography. J Instrum 8:C04002. https://doi.org/10.1088/1748-0221/8/04/C04002CrossRef Aubry N, Auffray E, Mimoun FB, Brillouet N, Bugalho R, Charbon E, Charles O, Cortinovis D, Courday P, Cserkaszky A, Damon C, Doroud K, Fischer J-M, Fornaro G, Fourmigue J-M, Frisch B, Fürst B, Gardiazabal J, Gadow K, Garutti E et al (2013) EndoTOFPET-US: a novel multimodal tool for endoscopy and positron emission tomography. J Instrum 8:C04002. https://​doi.​org/​10.​1088/​1748-0221/​8/​04/​C04002CrossRef
13.
Zurück zum Zitat Zhong J, Zhao W, Ren F, Qi S, Wang X, Lv T, Su Z, Yin H, Ren J, Huan Y (2016) Lymph node metastasis in patients with gastric cancer: a multi-modality, morphologic and functional imaging study. Am J Transl Res 8:5601–5609PubMedPubMedCentral Zhong J, Zhao W, Ren F, Qi S, Wang X, Lv T, Su Z, Yin H, Ren J, Huan Y (2016) Lymph node metastasis in patients with gastric cancer: a multi-modality, morphologic and functional imaging study. Am J Transl Res 8:5601–5609PubMedPubMedCentral
14.
Zurück zum Zitat Liyanaarachchi MR, Shimazoe K, Takahashi H, Kobayashi E, Sakuma I (2018) Simulation study on system configuration refinement for the PET–laparoscope system—an intraoperative tool for surgical navigation in gastric cancer surgery. Biomed Phys Eng Express 5:015002. https://doi.org/10.1088/2057-1976/aae902CrossRef Liyanaarachchi MR, Shimazoe K, Takahashi H, Kobayashi E, Sakuma I (2018) Simulation study on system configuration refinement for the PET–laparoscope system—an intraoperative tool for surgical navigation in gastric cancer surgery. Biomed Phys Eng Express 5:015002. https://​doi.​org/​10.​1088/​2057-1976/​aae902CrossRef
17.
Zurück zum Zitat Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. In: SPIE 5367, med imaging 2004 vis image-guided. Proced disp (SanDiego, California, United States) pp 421–32. https://doi.org/10.1117/12.536128 Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. In: SPIE 5367, med imaging 2004 vis image-guided. Proced disp (SanDiego, California, United States) pp 421–32. https://​doi.​org/​10.​1117/​12.​536128
Metadaten
Titel
Development and evaluation of a prototype detector for an intraoperative laparoscopic coincidence imaging system with PET tracers
verfasst von
Madhushanka R. Liyanaarachchi
Kenji Shimazoe
Hiroyuki Takahashi
Keiichi Nakagawa
Etsuko Kobayashi
Ichiro Sakuma
Publikationsdatum
07.11.2020
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 1/2021
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-020-02282-0

Weitere Artikel der Ausgabe 1/2021

International Journal of Computer Assisted Radiology and Surgery 1/2021 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.