Skip to main content
Erschienen in: HAND 1/2014

01.03.2014

Computed tomography for suspected scaphoid fractures: comparison of reformations in the plane of the wrist versus the long axis of the scaphoid

verfasst von: Wouter H. Mallee, Job N. Doornberg, David Ring, Mario Maas, Maaike Muhl, C. Niek van Dijk, J. Carel Goslings

Erschienen in: HAND | Ausgabe 1/2014

Einloggen, um Zugang zu erhalten

Abstract

Background

Definitive diagnosis of occult scaphoid fractures remains difficult. We tested the null hypothesis that, for diagnosis of true fractures among suspected scaphoid fractures, computed tomography (CT) reformations along the long axis of the scaphoid have the same accuracy as reformations made relative to the anatomical planes of the wrist.

Methods

In a prospective trial, 34 patients with a suspected scaphoid fracture underwent CT scanning within 10 days after trauma. CT reformations along the long axis of the scaphoid (CT-scaphoid) and along planes relative to the wrist (CT-wrist) were made. We used radiographs obtained 6 weeks after injury as the reference standard for a true fracture. A blinded panel including two surgeons and one radiologist came to a consensus diagnosis for each reformation plane.

Results

The reference standard showed six fractures of the scaphoid (prevalence, 18 %). Using CT-wrist, a scaphoid fracture was diagnosed in five patients (15 %), with three false positive, four false negative and two true positive diagnoses. Using CT-scaphoid, a scaphoid fracture was diagnosed in five patients (15 %), with one false positive, two false negative and four true positive results. Sensitivity, specificity and accuracy were 33, 89 and 79 % for CT-wrist and 67, 96 and 91 % for CT-scaphoid, respectively. This resulted in positive predictive values of 36 % for CT-wrist and 76 % for CT-scaphoid. Negative predictive values were 87 % for CT-wrist and 94 % for CT-scaphoid. No significant differences were found with the number of patients available.

Conclusions

For diagnosis of true fractures among suspected scaphoid fractures, the diagnostic performance characteristics of CT scans reformatted along the long axis of the scaphoid were better than CT scans in the planes of the wrist, but the differences were not significant.
Literatur
1.
Zurück zum Zitat Adey L, Souer JS, Lozano-Calderon S, Palmer W, Lee SG, Ring D. Computed tomography of suspected scaphoid fractures. J Hand Surg Am. 2007;32:61–6.PubMedCrossRef Adey L, Souer JS, Lozano-Calderon S, Palmer W, Lee SG, Ring D. Computed tomography of suspected scaphoid fractures. J Hand Surg Am. 2007;32:61–6.PubMedCrossRef
3.
Zurück zum Zitat Bain GI, Bennett JD, Richards RS, Slethaug GP, Roth JH. Longitudinal computed tomography of the scaphoid: a new technique. Skeletal Radiol. 1995;24:271–3.PubMedCrossRef Bain GI, Bennett JD, Richards RS, Slethaug GP, Roth JH. Longitudinal computed tomography of the scaphoid: a new technique. Skeletal Radiol. 1995;24:271–3.PubMedCrossRef
4.
Zurück zum Zitat Buijze GA, Mallee WH, Beeres FJ, Hanson TE, Johnson WO, Ring D. Diagnostic performance tests for suspected scaphoid fractures differ with conventional and latent class analysis. Clin Orthop Relat Res. 2011;469:3400–7.PubMedCrossRef Buijze GA, Mallee WH, Beeres FJ, Hanson TE, Johnson WO, Ring D. Diagnostic performance tests for suspected scaphoid fractures differ with conventional and latent class analysis. Clin Orthop Relat Res. 2011;469:3400–7.PubMedCrossRef
5.
Zurück zum Zitat Chen SC. The scaphoid compression test. J Hand Surg (Br). 1989;14:323–5.CrossRef Chen SC. The scaphoid compression test. J Hand Surg (Br). 1989;14:323–5.CrossRef
6.
Zurück zum Zitat Jenkins PJ, Slade K, Huntley JS, Robinson CM. A comparative analysis of the accuracy, diagnostic uncertainty and cost of imaging modalities in suspected scaphoid fractures. Injury. 2008;39:768–74.PubMedCrossRef Jenkins PJ, Slade K, Huntley JS, Robinson CM. A comparative analysis of the accuracy, diagnostic uncertainty and cost of imaging modalities in suspected scaphoid fractures. Injury. 2008;39:768–74.PubMedCrossRef
7.
Zurück zum Zitat Kocher MS, Zurakowski D. Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons. J Bone Joint Surg Am. 2004;86-A:607–20.PubMed Kocher MS, Zurakowski D. Clinical epidemiology and biostatistics: a primer for orthopaedic surgeons. J Bone Joint Surg Am. 2004;86-A:607–20.PubMed
8.
Zurück zum Zitat Lozano-Calderon S, Blazar P, Zurakowski D, Lee SG, Ring D. Diagnosis of scaphoid fracture displacement with radiography and computed tomography. J Bone Joint Surg Am. 2006;88:2695–703.PubMedCrossRef Lozano-Calderon S, Blazar P, Zurakowski D, Lee SG, Ring D. Diagnosis of scaphoid fracture displacement with radiography and computed tomography. J Bone Joint Surg Am. 2006;88:2695–703.PubMedCrossRef
9.
Zurück zum Zitat Mallee W, Doornberg JN, Ring D, van Dijk CN, Maas M, Goslings JC. Comparison of CT and MRI for diagnosis of suspected scaphoid fractures. J Bone Joint Surg Am. 2011;93:20–8.PubMedCrossRef Mallee W, Doornberg JN, Ring D, van Dijk CN, Maas M, Goslings JC. Comparison of CT and MRI for diagnosis of suspected scaphoid fractures. J Bone Joint Surg Am. 2011;93:20–8.PubMedCrossRef
10.
Zurück zum Zitat Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C, et al. Occult scaphoid fractures: comparison of multidetector CT and MR imaging—initial experience. Radiology. 2006;240:169–76.PubMedCrossRef Memarsadeghi M, Breitenseher MJ, Schaefer-Prokop C, et al. Occult scaphoid fractures: comparison of multidetector CT and MR imaging—initial experience. Radiology. 2006;240:169–76.PubMedCrossRef
11.
Zurück zum Zitat Miettinen OS. The matched pairs design in the case of all-or-none responses. Biometrics. 1968;24:339–52.PubMedCrossRef Miettinen OS. The matched pairs design in the case of all-or-none responses. Biometrics. 1968;24:339–52.PubMedCrossRef
12.
Zurück zum Zitat Munk B, Frokjaer J, Larsen CF, et al. Diagnosis of scaphoid fractures. A prospective multicenter study of 1,052 patients with 160 fractures. Acta Orthop Scand. 1995;66:359–60.PubMedCrossRef Munk B, Frokjaer J, Larsen CF, et al. Diagnosis of scaphoid fractures. A prospective multicenter study of 1,052 patients with 160 fractures. Acta Orthop Scand. 1995;66:359–60.PubMedCrossRef
13.
Zurück zum Zitat Ring D, Jupiter JB, Herndon JH. Acute fractures of the scaphoid. J Am Acad Orthop Surg. 2000;8:225–31.PubMed Ring D, Jupiter JB, Herndon JH. Acute fractures of the scaphoid. J Am Acad Orthop Surg. 2000;8:225–31.PubMed
14.
Zurück zum Zitat Ring D, Lozano-Calderon S. Imaging for suspected scaphoid fracture. J Hand Surg Am. 2008;33:954–7.PubMedCrossRef Ring D, Lozano-Calderon S. Imaging for suspected scaphoid fracture. J Hand Surg Am. 2008;33:954–7.PubMedCrossRef
15.
Zurück zum Zitat Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg Am. 1988;13:182–7.PubMedCrossRef Sanders WE. Evaluation of the humpback scaphoid by computed tomography in the longitudinal axial plane of the scaphoid. J Hand Surg Am. 1988;13:182–7.PubMedCrossRef
16.
Zurück zum Zitat Stewart NR, Gilula LA. CT of the wrist: a tailored approach. Radiology. 1992;183:13–20.PubMed Stewart NR, Gilula LA. CT of the wrist: a tailored approach. Radiology. 1992;183:13–20.PubMed
17.
Zurück zum Zitat Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003;3:25.PubMedCentralPubMedCrossRef Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol. 2003;3:25.PubMedCentralPubMedCrossRef
Metadaten
Titel
Computed tomography for suspected scaphoid fractures: comparison of reformations in the plane of the wrist versus the long axis of the scaphoid
verfasst von
Wouter H. Mallee
Job N. Doornberg
David Ring
Mario Maas
Maaike Muhl
C. Niek van Dijk
J. Carel Goslings
Publikationsdatum
01.03.2014
Verlag
Springer US
Erschienen in
HAND / Ausgabe 1/2014
Print ISSN: 1558-9447
Elektronische ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-013-9556-z

Weitere Artikel der Ausgabe 1/2014

HAND 1/2014 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.