Skip to main content

01.11.2012 | Original Article

In Vivo Analysis of the Morphologic Characteristics of Synthetic Mesh to Resist MRSA Adherence

Erschienen in: Journal of Gastrointestinal Surgery | Ausgabe 11/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Synthetic mesh has significantly reduced recurrence rates for ventral hernia repair; however, prosthetic mesh infections remain a significant complication. We hypothesized that unique mesh constructs might alter the ability of various synthetic meshes to clear bacterial contamination. To evaluate this, we studied commercially available synthetic meshes ability to clear a bacterial contamination with methicillin resistant Staphylococcus aureus infection.

Methods

Two hundred and eighty-three rats underwent hernia repair with one of nine synthetic materials. Control animals were closed, and the remainder was inoculated with either 104 or 106 methicillin-resistant S. aureus (MRSA). Animals were survived for 30 days without systemic antibiotics. At necropsy, the mesh was harvested and quantitative cultures and bacterial clearance assessed.

Results

All clean repairs remained sterile. Rates of bacterial clearance for 104 repairs revealed that unprotected monofilament materials cleared significantly more bacteria than composite meshes and multifilament meshes (p = <0.01 and p = 0.01, respectively). At higher levels of bacterial contamination (106), all materials had a reduction in bacterial clearance, although monofilament materials had higher bacterial clearance compared to composite meshes (p = 0.03).

Conclusions

Monofilament unprotected polypropylene and polyester mesh can clear a large percentage of MRSA contaminants. Multifilament, composite anti-adhesive barrier meshes, and laminar antimicrobial impregnated mesh are not able to clear bacterial contamination with MRSA. Unique properties of synthetic material should be considered when evaluating a prosthetic for high-risk incisional hernia repair.
Literatur
1.
Zurück zum Zitat Luijendijk, R.W., et al., A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med, 2000. 343(6): p. 392–8.PubMedCrossRef Luijendijk, R.W., et al., A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med, 2000. 343(6): p. 392–8.PubMedCrossRef
2.
Zurück zum Zitat Engelsman, A.F., et al., In vivo evaluation of bacterial infection involving morphologically different surgical meshes. Ann Surg, 2010. 251(1): p. 133–7.PubMedCrossRef Engelsman, A.F., et al., In vivo evaluation of bacterial infection involving morphologically different surgical meshes. Ann Surg, 2010. 251(1): p. 133–7.PubMedCrossRef
3.
Zurück zum Zitat Engelsman, A.F., et al., The phenomenon of infection with abdominal wall reconstruction. Biomaterials, 2007. 28(14): p. 2314–27.PubMedCrossRef Engelsman, A.F., et al., The phenomenon of infection with abdominal wall reconstruction. Biomaterials, 2007. 28(14): p. 2314–27.PubMedCrossRef
4.
Zurück zum Zitat Burger, J.W., et al., Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg, 2004. 240(4): p. 578–83; discussion 583–5.PubMed Burger, J.W., et al., Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg, 2004. 240(4): p. 578–83; discussion 583–5.PubMed
5.
Zurück zum Zitat Hesselink, V.J., et al., An evaluation of risk factors in incisional hernia recurrence. Surg Gynecol Obstet, 1993. 176(3): p. 228–34.PubMed Hesselink, V.J., et al., An evaluation of risk factors in incisional hernia recurrence. Surg Gynecol Obstet, 1993. 176(3): p. 228–34.PubMed
6.
Zurück zum Zitat Engelsman, A.F., et al., Morphological aspects of surgical meshes as a risk factor for bacterial colonization. Br J Surg, 2008. 95(8): p. 1051–9.PubMedCrossRef Engelsman, A.F., et al., Morphological aspects of surgical meshes as a risk factor for bacterial colonization. Br J Surg, 2008. 95(8): p. 1051–9.PubMedCrossRef
7.
Zurück zum Zitat Halaweish, I., et al., Novel in vitro model for assessing susceptibility of synthetic hernia repair meshes to Staphylococcus aureus infection using green fluorescent protein-labeled bacteria and modern imaging techniques. Surg Infect (Larchmt), 2010. 11(5): p. 449–54.CrossRef Halaweish, I., et al., Novel in vitro model for assessing susceptibility of synthetic hernia repair meshes to Staphylococcus aureus infection using green fluorescent protein-labeled bacteria and modern imaging techniques. Surg Infect (Larchmt), 2010. 11(5): p. 449–54.CrossRef
8.
Zurück zum Zitat Klinge, U., et al., Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res, 2002. 63(2): p. 129–36.PubMedCrossRef Klinge, U., et al., Functional and morphological evaluation of a low-weight, monofilament polypropylene mesh for hernia repair. J Biomed Mater Res, 2002. 63(2): p. 129–36.PubMedCrossRef
9.
Zurück zum Zitat An, Y.H. and R.J. Friedman, Concise review of mechanisms of bacterial adhesion to biomaterial surfaces. J Biomed Mater Res, 1998. 43(3): p. 338–48.PubMedCrossRef An, Y.H. and R.J. Friedman, Concise review of mechanisms of bacterial adhesion to biomaterial surfaces. J Biomed Mater Res, 1998. 43(3): p. 338–48.PubMedCrossRef
10.
Zurück zum Zitat Davidson, C.A. and C.R. Lowe, Optimisation of polymeric surface pre-treatment to prevent bacterial biofilm formation for use in microfluidics. J Mol Recognit, 2004. 17(3): p. 180–5.PubMedCrossRef Davidson, C.A. and C.R. Lowe, Optimisation of polymeric surface pre-treatment to prevent bacterial biofilm formation for use in microfluidics. J Mol Recognit, 2004. 17(3): p. 180–5.PubMedCrossRef
11.
Zurück zum Zitat Gottenbos, B., H.C. van der Mei, and H.J. Busscher, Initial adhesion and surface growth of Staphylococcus epidermidis and Pseudomonas aeruginosa on biomedical polymers. J Biomed Mater Res, 2000. 50(2): p. 208–14.PubMedCrossRef Gottenbos, B., H.C. van der Mei, and H.J. Busscher, Initial adhesion and surface growth of Staphylococcus epidermidis and Pseudomonas aeruginosa on biomedical polymers. J Biomed Mater Res, 2000. 50(2): p. 208–14.PubMedCrossRef
12.
Zurück zum Zitat Harrell, A.G., et al., In vitro infectability of prosthetic mesh by methicillin-resistant Staphylococcus aureus. Hernia, 2006. 10(2): p. 120–4.PubMedCrossRef Harrell, A.G., et al., In vitro infectability of prosthetic mesh by methicillin-resistant Staphylococcus aureus. Hernia, 2006. 10(2): p. 120–4.PubMedCrossRef
13.
Zurück zum Zitat Carbonell, A.M., et al., Susceptibility of prosthetic biomaterials to infection. Surg Endosc, 2005. 19(12): p. 1670.PubMedCrossRef Carbonell, A.M., et al., Susceptibility of prosthetic biomaterials to infection. Surg Endosc, 2005. 19(12): p. 1670.PubMedCrossRef
Metadaten
Titel
In Vivo Analysis of the Morphologic Characteristics of Synthetic Mesh to Resist MRSA Adherence
Publikationsdatum
01.11.2012
Erschienen in
Journal of Gastrointestinal Surgery / Ausgabe 11/2012
Print ISSN: 1091-255X
Elektronische ISSN: 1873-4626
DOI
https://doi.org/10.1007/s11605-012-1992-5

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.