Abstract

A new artificial chordal reconstruction technique has been developed using several expanded polytetrafluoroethylene (ePTFE) loops. This technique differs from conventional artificial chordal reconstruction in the use of premeasured ePTFE loops. The loop technique involves several steps: (1) assessment of the corresponding papillary muscle; (2) measurement of the required ePTFE loop length; (3) making a loop set of the premeasured length; (4) anchoring the loop set to the papillary muscle; (5) fixing the ePTFE loops to the prolapsing leaflet; (6) adjusting the loop length if necessary; and (7) ring implantation. Favorable early and mid-term results of this loop technique have been reported in patients undergoing mitral valve repair through mini-thoracotomy and via median sternotomy, with 3-year survival and re-operation-free rates of 94.8 and 97.4 %, respectively. The loop technique using ePTFE chordal reconstruction with premeasured loops thus appears to be a safe, reliable, and reproducible technique for mitral valve repair. In addition, it is suitable for both minimally invasive and conventional sternotomy approaches, and represents a useful technique for treating posterior, anterior, and especially bi-leaflet prolapses.
Literatur
1.
Zurück zum Zitat Carpentier A. Cardiac valve surgery: the “French correction”. J Thorac Cardiovasc Surg. 1983;86:323–37.PubMed Carpentier A. Cardiac valve surgery: the “French correction”. J Thorac Cardiovasc Surg. 1983;86:323–37.PubMed
2.
Zurück zum Zitat David T, Bos J, Rakowski H. Mitral valve repair by replacement of chordae tendineae with polytetrafluoroethylene sutures. J Thorac Cardiovasc Surg. 1991;101:495–501.PubMed David T, Bos J, Rakowski H. Mitral valve repair by replacement of chordae tendineae with polytetrafluoroethylene sutures. J Thorac Cardiovasc Surg. 1991;101:495–501.PubMed
3.
Zurück zum Zitat Kobayashi J, Sasako Y, Bando K, Minatoya K, Niwaya K, Kitamura S. Ten-year experience of choral replacement with expanded polytetrafluoroethylene in mitral valve repair. Circulation. 2000;102(suppl III):III30–4.PubMed Kobayashi J, Sasako Y, Bando K, Minatoya K, Niwaya K, Kitamura S. Ten-year experience of choral replacement with expanded polytetrafluoroethylene in mitral valve repair. Circulation. 2000;102(suppl III):III30–4.PubMed
4.
Zurück zum Zitat Salavador L, Mirone S, Bianchini R, Regesta T, Patelli F, Minniti G, et al. A 20-year experience with mitral valve repair with artificial chordae in 608 patients. J Thorac Cardiovasc Surg. 2008;135:1280–7.CrossRef Salavador L, Mirone S, Bianchini R, Regesta T, Patelli F, Minniti G, et al. A 20-year experience with mitral valve repair with artificial chordae in 608 patients. J Thorac Cardiovasc Surg. 2008;135:1280–7.CrossRef
5.
Zurück zum Zitat David TE, Armstrong S, Ivanov J. Chordal replacement with polytetrafluoroethylene sutures for mitral valve repair: a 25-year experience. J Thorac Cardiovasc Surg. 2013;145:1563–9.PubMedCrossRef David TE, Armstrong S, Ivanov J. Chordal replacement with polytetrafluoroethylene sutures for mitral valve repair: a 25-year experience. J Thorac Cardiovasc Surg. 2013;145:1563–9.PubMedCrossRef
6.
Zurück zum Zitat Bortolotti U, Celiento M, Pratali S, Anastoasio G, Pucci A. Recurrent mitral regurgitation due to ruptured artificial chordae: case report and review of the literature. J Heart Val Dis. 2012;21:440–3. Bortolotti U, Celiento M, Pratali S, Anastoasio G, Pucci A. Recurrent mitral regurgitation due to ruptured artificial chordae: case report and review of the literature. J Heart Val Dis. 2012;21:440–3.
7.
Zurück zum Zitat Perier P, Hohenberger W, Lakew F, Batz G, Urbanski P, Zacher M, et al. Toward a new paradigm for the reconstruction of posterior leaflet prolapse: midterm results of the “Respect rather than resect” approach. Ann Thorac Surg. 2008;86:718–25.PubMedCrossRef Perier P, Hohenberger W, Lakew F, Batz G, Urbanski P, Zacher M, et al. Toward a new paradigm for the reconstruction of posterior leaflet prolapse: midterm results of the “Respect rather than resect” approach. Ann Thorac Surg. 2008;86:718–25.PubMedCrossRef
8.
Zurück zum Zitat Patrick Perier. A new paradigm for the repair of posterior leaflet prolapse: respect rather than resect. Oper Tech Thor Cardiovasc Surg. 2005;10:180–93.CrossRef Patrick Perier. A new paradigm for the repair of posterior leaflet prolapse: respect rather than resect. Oper Tech Thor Cardiovasc Surg. 2005;10:180–93.CrossRef
9.
Zurück zum Zitat Lawrie GM, Earle EA, Earle NR. Feasibility and intermediate term outcome of repair of prolapsing anterior mitral leaflets with artificial choral replacement in 152 patients. Ann Thorac Surg. 2006;81:849–56.PubMedCrossRef Lawrie GM, Earle EA, Earle NR. Feasibility and intermediate term outcome of repair of prolapsing anterior mitral leaflets with artificial choral replacement in 152 patients. Ann Thorac Surg. 2006;81:849–56.PubMedCrossRef
10.
Zurück zum Zitat Kasegawa H, Shimokawa T, Shibazaki I, Hayashi H, Koyanagi T, Ida T. Mitral valve repair for anterior leaflet prolapse with expanded polytetrafluoroethylene sutures. Ann Thorac Surg. 2006;81:1625–31.PubMedCrossRef Kasegawa H, Shimokawa T, Shibazaki I, Hayashi H, Koyanagi T, Ida T. Mitral valve repair for anterior leaflet prolapse with expanded polytetrafluoroethylene sutures. Ann Thorac Surg. 2006;81:1625–31.PubMedCrossRef
11.
Zurück zum Zitat Matsui Y, Fukuda Y, Naito Y, Sasaki S, Yasuda K. A new device for ensuring the correct length of artificial chordae in mitral valvuloplasty. Ann Thorac Surg. 2005;79:1064–5.PubMedCrossRef Matsui Y, Fukuda Y, Naito Y, Sasaki S, Yasuda K. A new device for ensuring the correct length of artificial chordae in mitral valvuloplasty. Ann Thorac Surg. 2005;79:1064–5.PubMedCrossRef
12.
Zurück zum Zitat Iida H, Sunagawa T, Doi A, Ishida K, Irabu S. A device for ensuring the neo-chordae replacement in mitral valve repair. Ann Thorac Surg. 2010;90:2071–2.PubMedCrossRef Iida H, Sunagawa T, Doi A, Ishida K, Irabu S. A device for ensuring the neo-chordae replacement in mitral valve repair. Ann Thorac Surg. 2010;90:2071–2.PubMedCrossRef
13.
Zurück zum Zitat Opell UO, Mohr FW. Choradal replacement for both minimally invasive and conventional mitral valve surgery using premeasured gore-tex loops. Ann Thorac Surg. 2000;70:2166–8.CrossRef Opell UO, Mohr FW. Choradal replacement for both minimally invasive and conventional mitral valve surgery using premeasured gore-tex loops. Ann Thorac Surg. 2000;70:2166–8.CrossRef
14.
Zurück zum Zitat Kuntze T, Morger MA, Falk V, Seeburger J, Girdauskas E, Doll N, et al. Early and mid-term results of mitral valve repair using premeasured gore-tex loops (‘loop technique’). Eur J Cardio-thoracic Surg. 2008;33:566–77.CrossRef Kuntze T, Morger MA, Falk V, Seeburger J, Girdauskas E, Doll N, et al. Early and mid-term results of mitral valve repair using premeasured gore-tex loops (‘loop technique’). Eur J Cardio-thoracic Surg. 2008;33:566–77.CrossRef
15.
Zurück zum Zitat Yozu R, Okamoto K, Kudo M, Nonaka H, Adams DH. New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery. J Thorac Cardiovasc Surg. 2012;143:S82–5.PubMedCrossRef Yozu R, Okamoto K, Kudo M, Nonaka H, Adams DH. New innovative instruments facilitate both direct-vision and endoscopic-assisted mini-mitral valve surgery. J Thorac Cardiovasc Surg. 2012;143:S82–5.PubMedCrossRef
16.
Zurück zum Zitat Seeburger J, Borger MA, Falk V, Mohr FW. Gore-tex loop implantation for mitral valve prolapse: the Leipzig loop technique. Oper Tech Thor Cardiovasc Surg. 2008;13:83–90.CrossRef Seeburger J, Borger MA, Falk V, Mohr FW. Gore-tex loop implantation for mitral valve prolapse: the Leipzig loop technique. Oper Tech Thor Cardiovasc Surg. 2008;13:83–90.CrossRef
17.
Zurück zum Zitat Gillinov AM, Banbury MK. Pre-measured artificial choradae for mitral valve repair. Ann Thorac Surg. 2007;84:2127–9.PubMedCrossRef Gillinov AM, Banbury MK. Pre-measured artificial choradae for mitral valve repair. Ann Thorac Surg. 2007;84:2127–9.PubMedCrossRef
19.
Zurück zum Zitat Mandegar MH, Yousefnia MA, Roshanali F. Preoperative determination of artificial chordae length. Ann Thorac Surg. 2007;84:680–2.PubMedCrossRef Mandegar MH, Yousefnia MA, Roshanali F. Preoperative determination of artificial chordae length. Ann Thorac Surg. 2007;84:680–2.PubMedCrossRef
20.
Zurück zum Zitat Calafiore A. Choice of artificial chordae length according to echocardiographic criteria. Ann Thorac Surg. 2006;81:375–7.PubMedCrossRef Calafiore A. Choice of artificial chordae length according to echocardiographic criteria. Ann Thorac Surg. 2006;81:375–7.PubMedCrossRef
21.
Zurück zum Zitat Tam R, Joshi P, Konstantinov IE. A simple method of preparing artificial chordae for mitral valve repair. J Thorac Cadiovasc Surg. 2006;132:1486.CrossRef Tam R, Joshi P, Konstantinov IE. A simple method of preparing artificial chordae for mitral valve repair. J Thorac Cadiovasc Surg. 2006;132:1486.CrossRef
22.
Zurück zum Zitat Shibata T, Inoue K, Ikuta T, Bito Y. A workbench to make artificial choral loops for mitral valve repair. J Thorac Cardiovasc Surg. 2009;138:506–7.PubMedCrossRef Shibata T, Inoue K, Ikuta T, Bito Y. A workbench to make artificial choral loops for mitral valve repair. J Thorac Cardiovasc Surg. 2009;138:506–7.PubMedCrossRef
23.
Zurück zum Zitat Cagli K. A simple method of making artificial chordal loops for mitral valve repair. Ann Thorac Surg. 2010;89:e12–4.PubMedCrossRef Cagli K. A simple method of making artificial chordal loops for mitral valve repair. Ann Thorac Surg. 2010;89:e12–4.PubMedCrossRef
24.
Zurück zum Zitat Dang NC, Stewart AS, Kay J, Mercando ML, Kruger KH, Topkara VK, et al. Simplified placement of multiple artificial mitral valve chords. Heart Surg For. 2005;8:E129–31.CrossRef Dang NC, Stewart AS, Kay J, Mercando ML, Kruger KH, Topkara VK, et al. Simplified placement of multiple artificial mitral valve chords. Heart Surg For. 2005;8:E129–31.CrossRef
25.
Zurück zum Zitat Seeburger J, Kuntze T, Mohf FW. Gore-tex chordo-plasty in degenerative mitral valve repair. Semi Thorac Cardiovasc Surg. 2007;19:111–5.CrossRef Seeburger J, Kuntze T, Mohf FW. Gore-tex chordo-plasty in degenerative mitral valve repair. Semi Thorac Cardiovasc Surg. 2007;19:111–5.CrossRef
26.
Zurück zum Zitat Okamoto K, Yozu R, Kudo M. Loop-in-loop technique in mitral valve repair via mini-thoracotomy. Ann Thorac Surg. 2012;93:1329–30.PubMedCrossRef Okamoto K, Yozu R, Kudo M. Loop-in-loop technique in mitral valve repair via mini-thoracotomy. Ann Thorac Surg. 2012;93:1329–30.PubMedCrossRef
27.
Zurück zum Zitat Duran CMG. Surgical techniques for the repair of anterior mitral leaflet prolapse. J Card Surg. 1999;14:471–81.PubMedCrossRef Duran CMG. Surgical techniques for the repair of anterior mitral leaflet prolapse. J Card Surg. 1999;14:471–81.PubMedCrossRef
28.
Zurück zum Zitat Seeburger J, Falk V, Borger MA, Passage J, Walther T, Doll N, Mohr FW. Chordae replacement versus resection for repair of isolated posterior mitral leaflet prolapse: a egalite. Ann Thorac Surg. 2009;87:1715–20.PubMedCrossRef Seeburger J, Falk V, Borger MA, Passage J, Walther T, Doll N, Mohr FW. Chordae replacement versus resection for repair of isolated posterior mitral leaflet prolapse: a egalite. Ann Thorac Surg. 2009;87:1715–20.PubMedCrossRef
29.
Zurück zum Zitat Lawrie GM, Earle EA, Earle N. Intermediate-term results of a non-resectional dynamic repair technique in 662 patients with mitral valve prolapse and mitral regurgitation. J Thorac Cardiovasc Surg. 2011;141:268–76.CrossRef Lawrie GM, Earle EA, Earle N. Intermediate-term results of a non-resectional dynamic repair technique in 662 patients with mitral valve prolapse and mitral regurgitation. J Thorac Cardiovasc Surg. 2011;141:268–76.CrossRef
30.
Zurück zum Zitat Lawrie GM, Earle EA, Earle NR. Non-resectional repair of the Barlow mitral valve: importance of dynamic annular evaluation. Ann Thorac Surg. 2009;88:1191–6.PubMedCrossRef Lawrie GM, Earle EA, Earle NR. Non-resectional repair of the Barlow mitral valve: importance of dynamic annular evaluation. Ann Thorac Surg. 2009;88:1191–6.PubMedCrossRef
31.
Zurück zum Zitat Lawrie GM. Letter to the editor. J Heart Val Dis. 2012;21:686–7. Lawrie GM. Letter to the editor. J Heart Val Dis. 2012;21:686–7.
32.
Zurück zum Zitat Kudo M, Yozu R, Kokaji K, Kimura N. A simple method of prevention for systolic anterior motion in mitral valve repair by loop technique method. Ann Thorac Surg. 2009;87:324–5.PubMedCrossRef Kudo M, Yozu R, Kokaji K, Kimura N. A simple method of prevention for systolic anterior motion in mitral valve repair by loop technique method. Ann Thorac Surg. 2009;87:324–5.PubMedCrossRef
33.
Zurück zum Zitat Falk V, Seeburger J, Czesla M, Borger MA, Willige J, Kuntze T, et al. How dose the use of polytetrafluoroethylene neo-chordae for posterior mitral valve prolapse (loop technique) compare with leaflet resection? A prospective randamized trial. J Thorac Cardiovasc Surg. 2008;136:1200–6.CrossRef Falk V, Seeburger J, Czesla M, Borger MA, Willige J, Kuntze T, et al. How dose the use of polytetrafluoroethylene neo-chordae for posterior mitral valve prolapse (loop technique) compare with leaflet resection? A prospective randamized trial. J Thorac Cardiovasc Surg. 2008;136:1200–6.CrossRef
34.
Zurück zum Zitat Yamashita MH, Skarsgard PL. Intermediate and early rupture of expanded polytetrafluoroethylene neo-chordae after mitral valve repair. Ann Thorac Surg. 2011;92:341–3.PubMedCrossRef Yamashita MH, Skarsgard PL. Intermediate and early rupture of expanded polytetrafluoroethylene neo-chordae after mitral valve repair. Ann Thorac Surg. 2011;92:341–3.PubMedCrossRef
35.
Zurück zum Zitat Fukunaga S, Tomoeda H, Ueda T, Mori R, Aoyagi S, Kato S. Recurrent mitral regurgitation due to calcified synthetic chordae. Ann Thorac Surg. 2010;89:955–7.PubMedCrossRef Fukunaga S, Tomoeda H, Ueda T, Mori R, Aoyagi S, Kato S. Recurrent mitral regurgitation due to calcified synthetic chordae. Ann Thorac Surg. 2010;89:955–7.PubMedCrossRef
36.
Zurück zum Zitat Farivar RS, Scherman SK, Chon LH. Late rupture of polytetrafluoroethylene neo-chordae after mitral valve repair. J Thorac Cardiovasc Surt. 2009;137:504–6.CrossRef Farivar RS, Scherman SK, Chon LH. Late rupture of polytetrafluoroethylene neo-chordae after mitral valve repair. J Thorac Cardiovasc Surt. 2009;137:504–6.CrossRef
37.
Zurück zum Zitat Minatoya K, Okabayashi H, Shimada I, Ohno N, Nshina T, Yokota T, et al. Pathologic aspects of polytetrafluoroethylene sutures in human heart. Ann Thorac Surg. 1996;61:883–7.PubMedCrossRef Minatoya K, Okabayashi H, Shimada I, Ohno N, Nshina T, Yokota T, et al. Pathologic aspects of polytetrafluoroethylene sutures in human heart. Ann Thorac Surg. 1996;61:883–7.PubMedCrossRef
38.
Zurück zum Zitat Minatoya K, Kobayashi J, Sasako Y, Ueda H, Yutani C, Kitamura S. Long-term pathological changes of expanded polytetrafluoroethylene (ePTFE) suture in the human heart. J Heart Val Dis. 2001;10:239–42. Minatoya K, Kobayashi J, Sasako Y, Ueda H, Yutani C, Kitamura S. Long-term pathological changes of expanded polytetrafluoroethylene (ePTFE) suture in the human heart. J Heart Val Dis. 2001;10:239–42.
39.
Zurück zum Zitat Bortolotti U, Milano AD, Frater RWM. Mitral valve repair with artificial chordae: a review of its history, technical details, long-term results, and pathology. Ann Thorac Surg. 2012;93:684–91.PubMedCrossRef Bortolotti U, Milano AD, Frater RWM. Mitral valve repair with artificial chordae: a review of its history, technical details, long-term results, and pathology. Ann Thorac Surg. 2012;93:684–91.PubMedCrossRef
Metadaten
Titel
Loop technique for mitral valve repair
verfasst von
Toshihiko Shibata
Publikationsdatum
01.02.2014
Verlag
Springer Japan
Erschienen in
General Thoracic and Cardiovascular Surgery / Ausgabe 2/2014
Print ISSN: 1863-6705
Elektronische ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-013-0320-7

Weitere Artikel der Ausgabe 2/2014

General Thoracic and Cardiovascular Surgery 2/2014 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

Karpaltunnelsyndrom BDC Leitlinien Webinare
CME: 2 Punkte

Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

Radiusfraktur BDC Leitlinien Webinare
CME: 2 Punkte

Das Webinar beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

Appendizitis BDC Leitlinien Webinare
CME: 2 Punkte

Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.