Abstract

Purpose

The goal of this study was to determine differences in fracture stability and functional outcome between synthetic bone graft and natural bone graft with internal fixation of tibia plateau metaphyseal defects.

Methods

Hydroxyapatite calcium carbonate synthetic bone graft was utilised in 14 patients (six males and eight females). Allograft/autograft were utilised in the remaining 10 patients (six males and four females). All the 24 patients had clinical, radiological and subjective functional score assessments.

Results

There was no significant statistical difference between the groups for post-operative articular reduction, long-term subsidence, and WOMAC scores. The degree of subsidence was not related to age or fracture severity. Maintenance of knee flexion was found to be better in the allograft/autograft group (p = 0.048) when compared between the groups. Multivariate analysis compared graft type, fracture severity, post-operative reduction, subsidence rate, range of movement and WOMAC score. The only finding was a statistical significant association with the graft type related to the 6-month range of movement figures.

Conclusions

Use of autologous or allogenic bone graft allows better recovery of long-term flexion, possibly due to reduced inflammatory response compared with synthetic bone composites. However, all other parameters, such as maintenance of joint reduction and subjective outcome measures were comparable with the use of hydroxyapatite calcium carbonate bone graft. This study shows that synthetic bone graft may be a suitable alternative in fixation of unstable tibia plateau fractures, avoiding risk of disease transmission with allograft and donor site morbidity associated with autograft.
Literatur
1.
Zurück zum Zitat Barei DP, Nork SE, Mills WJ et al (2004) Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 18(10):649–657PubMedCrossRef Barei DP, Nork SE, Mills WJ et al (2004) Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 18(10):649–657PubMedCrossRef
2.
Zurück zum Zitat Bellamy N, Buchanan WW (1986) A preliminary evaluation of the dimensionality and clinical importance of pain and disability in osteoarthrits of the hip and knee. Clin Rheumatol 5:231–241PubMedCrossRef Bellamy N, Buchanan WW (1986) A preliminary evaluation of the dimensionality and clinical importance of pain and disability in osteoarthrits of the hip and knee. Clin Rheumatol 5:231–241PubMedCrossRef
3.
Zurück zum Zitat Blokker CP, Rorabeck CH, Bourne RB (1984) Tibial plateau fractures. An analysis of the results of treatment in 60 patients. Clin Orthop Relat Res 182:193–199PubMed Blokker CP, Rorabeck CH, Bourne RB (1984) Tibial plateau fractures. An analysis of the results of treatment in 60 patients. Clin Orthop Relat Res 182:193–199PubMed
4.
Zurück zum Zitat Bucholz RW, Carlton A, Holmes R (1989) Interporous hydroxyapatite as bone graft substitute in tibial plateau fractures. Clin Orthop 240:53–62PubMed Bucholz RW, Carlton A, Holmes R (1989) Interporous hydroxyapatite as bone graft substitute in tibial plateau fractures. Clin Orthop 240:53–62PubMed
5.
Zurück zum Zitat Covall DJ, Fowble CD, Foster TE et al (1994) Bicondylar tibial plateau fractures: principles of treatment. Contemp Orthop 28(2):115–122PubMed Covall DJ, Fowble CD, Foster TE et al (1994) Bicondylar tibial plateau fractures: principles of treatment. Contemp Orthop 28(2):115–122PubMed
6.
Zurück zum Zitat Delecrin J, Oka M, Takahashi S et al (1994) Changes in joint fluid after total arthroplasty. A quantitative study on the rabbit knee joint. Clin Orthop Relat Res 307:240–249PubMed Delecrin J, Oka M, Takahashi S et al (1994) Changes in joint fluid after total arthroplasty. A quantitative study on the rabbit knee joint. Clin Orthop Relat Res 307:240–249PubMed
7.
Zurück zum Zitat Fowler BL, Dall BE, Rowe DE (1995) Complications associated with harvesting autogenous iliac bone graft. Am J Orthop (Belle Mead NJ) 24(12):895–903 Fowler BL, Dall BE, Rowe DE (1995) Complications associated with harvesting autogenous iliac bone graft. Am J Orthop (Belle Mead NJ) 24(12):895–903
8.
Zurück zum Zitat Goulet JA, Senunas LE, DeSilva GL et al (1997) Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop 339:76–81PubMedCrossRef Goulet JA, Senunas LE, DeSilva GL et al (1997) Autogenous iliac crest bone graft. Complications and functional assessment. Clin Orthop 339:76–81PubMedCrossRef
9.
Zurück zum Zitat Keating JF, Hajducka CL, Harper J (2003) Minimal internal fixation and calcium-phosphate cement in the treatment of fractures of the tibial plateau. A pilot study. J Bone Joint Surg Br 85(1):68–73PubMedCrossRef Keating JF, Hajducka CL, Harper J (2003) Minimal internal fixation and calcium-phosphate cement in the treatment of fractures of the tibial plateau. A pilot study. J Bone Joint Surg Br 85(1):68–73PubMedCrossRef
10.
Zurück zum Zitat Korovessis P, Repanti M, Koureas G (2002) Does coralline hydroxyapatite conduct fusion in instrumented posterior spine fusion? Stud Health Technol Inform 91:109–113PubMed Korovessis P, Repanti M, Koureas G (2002) Does coralline hydroxyapatite conduct fusion in instrumented posterior spine fusion? Stud Health Technol Inform 91:109–113PubMed
11.
Zurück zum Zitat Lachiewicz PF, Funcik T (1990) Factors influencing the results of open reduction and internal fixation of tibial plateau fractures. Clin Orthop 259:210–215PubMed Lachiewicz PF, Funcik T (1990) Factors influencing the results of open reduction and internal fixation of tibial plateau fractures. Clin Orthop 259:210–215PubMed
12.
Zurück zum Zitat Martin J, Marsh JL, Nepola JV et al (2000) Radiographic fracture assessments: which ones can we reliably make? J Orthop Trauma 14(6):379–385PubMedCrossRef Martin J, Marsh JL, Nepola JV et al (2000) Radiographic fracture assessments: which ones can we reliably make? J Orthop Trauma 14(6):379–385PubMedCrossRef
13.
Zurück zum Zitat Palmer SH, Gibbons CLMH, Athanasou NA (1999) The pathology of bone allograft. J Bone Joint Surg Br 81(2):333–335PubMedCrossRef Palmer SH, Gibbons CLMH, Athanasou NA (1999) The pathology of bone allograft. J Bone Joint Surg Br 81(2):333–335PubMedCrossRef
14.
Zurück zum Zitat Russell TA, Leighton RK, Alpha-BSM Tibial Plateau Fracture Study Group (2008) Comparison of autogenous bone graft and endothermic calcium phosphate cement for defect augmentation in tibial plateau fractures. A multicenter, prospective, randomized study. J Bone Joint Surg Am 90(10):2057–2061PubMedCrossRef Russell TA, Leighton RK, Alpha-BSM Tibial Plateau Fracture Study Group (2008) Comparison of autogenous bone graft and endothermic calcium phosphate cement for defect augmentation in tibial plateau fractures. A multicenter, prospective, randomized study. J Bone Joint Surg Am 90(10):2057–2061PubMedCrossRef
15.
Zurück zum Zitat Schaefer SL, Lu Y, Seeherman H et al (2009) Effect of rhBMP-2 on tibial plateau fractures in a canine model. J Orthop Res 27(4):466–471PubMedCrossRef Schaefer SL, Lu Y, Seeherman H et al (2009) Effect of rhBMP-2 on tibial plateau fractures in a canine model. J Orthop Res 27(4):466–471PubMedCrossRef
16.
Zurück zum Zitat Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture. The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104PubMed Schatzker J, McBroom R, Bruce D (1979) The tibial plateau fracture. The Toronto experience 1968–1975. Clin Orthop Relat Res 138:94–104PubMed
17.
Zurück zum Zitat Silber JS, Anderson DG, Daffner SD et al (2003) Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion. Spine 28:134–139PubMedCrossRef Silber JS, Anderson DG, Daffner SD et al (2003) Donor site morbidity after anterior iliac crest bone harvest for single-level anterior cervical discectomy and fusion. Spine 28:134–139PubMedCrossRef
18.
Zurück zum Zitat Su EP, Westrich GH, Rana AJ et al (2004) Operative treatment of tibial plateau fractures in patients older than 55 years. Clin Orthop Relat Res 421:240–248PubMedCrossRef Su EP, Westrich GH, Rana AJ et al (2004) Operative treatment of tibial plateau fractures in patients older than 55 years. Clin Orthop Relat Res 421:240–248PubMedCrossRef
19.
Zurück zum Zitat Tscherne H, Lobenhoffer P (1993) Tibial plateau fractures. Management and expected results. Clin Orthop Relat Res 292:87–100PubMed Tscherne H, Lobenhoffer P (1993) Tibial plateau fractures. Management and expected results. Clin Orthop Relat Res 292:87–100PubMed
20.
Zurück zum Zitat Younger EM, Chapman MW (1989) Morbidity at bone graft donor sites. J Orthop Trauma 3:192–195PubMedCrossRef Younger EM, Chapman MW (1989) Morbidity at bone graft donor sites. J Orthop Trauma 3:192–195PubMedCrossRef
21.
Zurück zum Zitat Horstmann WG, Verheyen CC, Leemans R (2003) An injectable calcium phosphate cement as a bone-graft substitute in the treatment of displaced lateral tibial plateau fractures. Injury 34:141–144PubMedCrossRef Horstmann WG, Verheyen CC, Leemans R (2003) An injectable calcium phosphate cement as a bone-graft substitute in the treatment of displaced lateral tibial plateau fractures. Injury 34:141–144PubMedCrossRef
22.
Zurück zum Zitat Lim EV, Lavadia WT, Roberts JM (1996) Superior gluteal artery injury during iliac bone grafting for spinal fusion. A case report and literature review. Spine 21(20):2376–2378PubMedCrossRef Lim EV, Lavadia WT, Roberts JM (1996) Superior gluteal artery injury during iliac bone grafting for spinal fusion. A case report and literature review. Spine 21(20):2376–2378PubMedCrossRef
Metadaten
Titel
Fixation of tibial plateau fractures with synthetic bone graft versus natural bone graft: a comparison study
verfasst von
J. C. Y. Ong
M. T. Kennedy
A. Mitra
J. A. Harty
Publikationsdatum
01.06.2012
Verlag
Springer-Verlag
Erschienen in
Irish Journal of Medical Science (1971 -) / Ausgabe 2/2012
Print ISSN: 0021-1265
Elektronische ISSN: 1863-4362
DOI
https://doi.org/10.1007/s11845-011-0797-y

Weitere Artikel der Ausgabe 2/2012

Irish Journal of Medical Science (1971 -) 2/2012 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.