Abstract

The lack of reliable imaging tools in detecting prostate cancer makes a random biopsy still the standard of care to detect prostate cancer. To reduce the number of cores during a biopsy and therefore the risk of biopsy-related complications, an imaging tool which provides reliable guided biopsies is required. Transrectal real-time elastography has shown to have the ability to visualize prostate cancer foci to some extent. In addition to the conventional B-mode image of transrectal ultrasound, it adds information about the stiffness of the prostate tissue. This review highlights the most important studies on elastography to follow the improvements in techniques and to outline the ability to detect prostate cancer and guide biopsies.
Literatur
1.
Zurück zum Zitat Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X. Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging. 1991;13(2):111–34.PubMed Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X. Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging. 1991;13(2):111–34.PubMed
3.•
Zurück zum Zitat Walz J, Marcy M, Pianna JT, Brunelle S, Gravis G, Salem N, et al. Identification of the prostate cancer index lesion by real-time elastography: considerations for focal therapy of prostate cancer. World J Urol. 2011;29(5):589–94. doi:10.1007/s00345-011-0688-x.PubMedCrossRef Walz J, Marcy M, Pianna JT, Brunelle S, Gravis G, Salem N, et al. Identification of the prostate cancer index lesion by real-time elastography: considerations for focal therapy of prostate cancer. World J Urol. 2011;29(5):589–94. doi:10.​1007/​s00345-011-0688-x.PubMedCrossRef
4.••
Zurück zum Zitat Salomon G, Kollerman J, Thederan I, Chun FK, Budaus L, Schlomm T, et al. Evaluation of prostate cancer detection with ultrasound real-time elastography: a comparison with step section pathological analysis after radical prostatectomy. Eur Urol. 2008;54(6):1354–62. doi:10.1016/j.eururo.2008.02.035.PubMedCrossRef Salomon G, Kollerman J, Thederan I, Chun FK, Budaus L, Schlomm T, et al. Evaluation of prostate cancer detection with ultrasound real-time elastography: a comparison with step section pathological analysis after radical prostatectomy. Eur Urol. 2008;54(6):1354–62. doi:10.​1016/​j.​eururo.​2008.​02.​035.PubMedCrossRef
6.
7.
Zurück zum Zitat Tsutsumi M, Miyagawa T, Matsumura T, Endo T, Kandori S, Shimokama T, et al. Real-time balloon inflation elastography for prostate cancer detection and initial evaluation of clinicopathologic analysis. AJR Am J Roentgenol. 2010;194(6):W471–6. doi:10.2214/AJR.09.3301.PubMedCrossRef Tsutsumi M, Miyagawa T, Matsumura T, Endo T, Kandori S, Shimokama T, et al. Real-time balloon inflation elastography for prostate cancer detection and initial evaluation of clinicopathologic analysis. AJR Am J Roentgenol. 2010;194(6):W471–6. doi:10.​2214/​AJR.​09.​3301.PubMedCrossRef
8.••
Zurück zum Zitat Brock M, Eggert T, Palisaar RJ, Roghmann F, Braun K, Loppenberg B, et al. Multiparametric ultrasound of the prostate: adding contrast enhanced ultrasound to real-time elastography to detect histopathologically confirmed cancer. J Urol. 2013;189(1):93–8. doi:10.1016/j.juro.2012.08.183.PubMedCrossRef Brock M, Eggert T, Palisaar RJ, Roghmann F, Braun K, Loppenberg B, et al. Multiparametric ultrasound of the prostate: adding contrast enhanced ultrasound to real-time elastography to detect histopathologically confirmed cancer. J Urol. 2013;189(1):93–8. doi:10.​1016/​j.​juro.​2012.​08.​183.PubMedCrossRef
9.
Zurück zum Zitat Junker D, Schafer G, Aigner F, Schullian P, Pallwein-Prettner L, Bektic J, et al. Potentials and limitations of real-time elastography for prostate cancer detection: a whole-mount step section analysis. Sci World J. 2012;2012:193213. doi:10.1100/2012/193213.CrossRef Junker D, Schafer G, Aigner F, Schullian P, Pallwein-Prettner L, Bektic J, et al. Potentials and limitations of real-time elastography for prostate cancer detection: a whole-mount step section analysis. Sci World J. 2012;2012:193213. doi:10.​1100/​2012/​193213.CrossRef
10.
Zurück zum Zitat Rausch S, Alt W, Arps H, Alt B, Kalble T. The utility of transrectal sonoelastography in preoperative prostate cancer assessment. Med Ultrason. 2012;14(3):182–6.PubMedCrossRef Rausch S, Alt W, Arps H, Alt B, Kalble T. The utility of transrectal sonoelastography in preoperative prostate cancer assessment. Med Ultrason. 2012;14(3):182–6.PubMedCrossRef
11.
Zurück zum Zitat Zhu Y, Chen Y, Qi T, Jiang J, Qi J, Yu Y, et al. Prostate cancer detection with real-time elastography using a bi-plane transducer: comparison with step-section radical prostatectomy pathology. World J Urol. 2012. doi:10.1007/s00345-012-0922-1. Zhu Y, Chen Y, Qi T, Jiang J, Qi J, Yu Y, et al. Prostate cancer detection with real-time elastography using a bi-plane transducer: comparison with step-section radical prostatectomy pathology. World J Urol. 2012. doi:10.​1007/​s00345-012-0922-1.
12.
Zurück zum Zitat Tsutsumi M, Miyagawa T, Matsumura T, Kawazoe N, Ishikawa S, Shimokama T, et al. The impact of real-time tissue elasticity imaging (elastography) on the detection of prostate cancer: clinicopathological analysis. Int J Clin Oncol. 2007;12(4):250–5. doi:10.1007/s10147-007-0669-7.PubMedCrossRef Tsutsumi M, Miyagawa T, Matsumura T, Kawazoe N, Ishikawa S, Shimokama T, et al. The impact of real-time tissue elasticity imaging (elastography) on the detection of prostate cancer: clinicopathological analysis. Int J Clin Oncol. 2007;12(4):250–5. doi:10.​1007/​s10147-007-0669-7.PubMedCrossRef
13.
Zurück zum Zitat Zhang Y, Tang J, Li YM, Fei X, He EH, Li QY, et al. The contribution of strain patterns in characterization of prostate peripheral zone lesions at transrectal ultrasonography. Acta Radiol. 2012;53(1):119–26. doi:10.1258/ar.2011.110504.PubMedCrossRef Zhang Y, Tang J, Li YM, Fei X, He EH, Li QY, et al. The contribution of strain patterns in characterization of prostate peripheral zone lesions at transrectal ultrasonography. Acta Radiol. 2012;53(1):119–26. doi:10.​1258/​ar.​2011.​110504.PubMedCrossRef
14.
Zurück zum Zitat Draisma G, Etzioni R, Tsodikov A, Mariotto A, Wever E, Gulati R, et al. Lead time and overdiagnosis in prostate-specific antigen screening: importance of methods and context. J Natl Cancer Inst. 2009;101(6):374–83. doi:10.1093/jnci/djp001.PubMedCrossRef Draisma G, Etzioni R, Tsodikov A, Mariotto A, Wever E, Gulati R, et al. Lead time and overdiagnosis in prostate-specific antigen screening: importance of methods and context. J Natl Cancer Inst. 2009;101(6):374–83. doi:10.​1093/​jnci/​djp001.PubMedCrossRef
17.
Zurück zum Zitat Miyagawa T, Tsutsumi M, Matsumura T, Kawazoe N, Ishikawa S, Shimokama T, et al. Real-time elastography for the diagnosis of prostate cancer: evaluation of elastographic moving images. Jpn J Clin Oncol. 2009;39(6):394–8. doi:10.1093/jjco/hyp026.PubMedCrossRef Miyagawa T, Tsutsumi M, Matsumura T, Kawazoe N, Ishikawa S, Shimokama T, et al. Real-time elastography for the diagnosis of prostate cancer: evaluation of elastographic moving images. Jpn J Clin Oncol. 2009;39(6):394–8. doi:10.​1093/​jjco/​hyp026.PubMedCrossRef
18.
Zurück zum Zitat Giurgiu CR, Manea C, Crisan N, Bungardean C, Coman I, Dudea SM. Real-time sonoelastography in the diagnosis of prostate cancer. Med Ultrason. 2011;13(1):5–9.PubMed Giurgiu CR, Manea C, Crisan N, Bungardean C, Coman I, Dudea SM. Real-time sonoelastography in the diagnosis of prostate cancer. Med Ultrason. 2011;13(1):5–9.PubMed
20.
Zurück zum Zitat Eggert T, Khaled W, Wenske S, Ermert H, Noldus J. Impact of elastography in clinical diagnosis of prostate cancer. A comparison of cancer detection between B-mode sonography and elastography-guided 10-core biopsies. Urologe A. 2008;47(9):1212–7.PubMedCrossRef Eggert T, Khaled W, Wenske S, Ermert H, Noldus J. Impact of elastography in clinical diagnosis of prostate cancer. A comparison of cancer detection between B-mode sonography and elastography-guided 10-core biopsies. Urologe A. 2008;47(9):1212–7.PubMedCrossRef
21.•
Zurück zum Zitat Aigner F, Pallwein L, Junker D, Schafer G, Mikuz G, Pedross F, et al. Value of real-time elastography targeted biopsy for prostate cancer detection in men with prostate-specific antigen 1.25 ng/ml or greater and 4.00 ng/ml or less. J Urol. 2010;184(3):913–7.PubMedCrossRef Aigner F, Pallwein L, Junker D, Schafer G, Mikuz G, Pedross F, et al. Value of real-time elastography targeted biopsy for prostate cancer detection in men with prostate-specific antigen 1.25 ng/ml or greater and 4.00 ng/ml or less. J Urol. 2010;184(3):913–7.PubMedCrossRef
22.••
Zurück zum Zitat Aigner F, Pallwein L, Schocke M, Lebovici A, Junker D, Schafer G, et al. Comparison of real-time sonoelastography with T2-weighted endorectal magnetic resonance imaging for prostate cancer detection. J Ultrasound Med. 2011;30(5):643–9.PubMed Aigner F, Pallwein L, Schocke M, Lebovici A, Junker D, Schafer G, et al. Comparison of real-time sonoelastography with T2-weighted endorectal magnetic resonance imaging for prostate cancer detection. J Ultrasound Med. 2011;30(5):643–9.PubMed
23.
Zurück zum Zitat Aigner F, Schafer G, Steiner E, Jaschke W, Horninger W, Herrmann TR, et al. Value of enhanced transrectal ultrasound targeted biopsy for prostate cancer diagnosis: a retrospective data analysis. World J Urol. 2012;30(3):341–6. doi:10.1007/s00345-011-0809-6.PubMedCrossRef Aigner F, Schafer G, Steiner E, Jaschke W, Horninger W, Herrmann TR, et al. Value of enhanced transrectal ultrasound targeted biopsy for prostate cancer diagnosis: a retrospective data analysis. World J Urol. 2012;30(3):341–6. doi:10.​1007/​s00345-011-0809-6.PubMedCrossRef
24.•
Zurück zum Zitat Ganzer R, Brandtner A, Wieland WF, Fritsche HM. Prospective blinded comparison of real-time sonoelastography targeted versus randomised biopsy of the prostate in the primary and re-biopsy setting. World J Urol. 2012;30(2):219–23. doi:10.1007/s00345-011-0679-y.PubMedCrossRef Ganzer R, Brandtner A, Wieland WF, Fritsche HM. Prospective blinded comparison of real-time sonoelastography targeted versus randomised biopsy of the prostate in the primary and re-biopsy setting. World J Urol. 2012;30(2):219–23. doi:10.​1007/​s00345-011-0679-y.PubMedCrossRef
26.
Zurück zum Zitat Taverna G, Magnoni P, Giusti G, Seveso M, Benetti A, Hurle R, et al. Impact of real-time elastography versus systematic prostate biopsy method on cancer detection rate in men with a serum prostate-specific antigen between 2.5 and 10 ng/mL. ISRN. Oncol. 2013;2013:584672. Taverna G, Magnoni P, Giusti G, Seveso M, Benetti A, Hurle R, et al. Impact of real-time elastography versus systematic prostate biopsy method on cancer detection rate in men with a serum prostate-specific antigen between 2.5 and 10 ng/mL. ISRN. Oncol. 2013;2013:584672.
29.
Zurück zum Zitat Pallwein L, Mitterberger M, Struve P, Horninger W, Aigner F, Bartsch G, et al. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection. Eur Radiol. 2007;17(9):2278–85. doi:10.1007/s00330-007-0606-1.PubMedCrossRef Pallwein L, Mitterberger M, Struve P, Horninger W, Aigner F, Bartsch G, et al. Comparison of sonoelastography guided biopsy with systematic biopsy: impact on prostate cancer detection. Eur Radiol. 2007;17(9):2278–85. doi:10.​1007/​s00330-007-0606-1.PubMedCrossRef
30.
Zurück zum Zitat Salomon G, Drews N, Autier P, Beckmann A, Heinzer H, Hansen J, et al. Incremental detection rate of prostate cancer by HI-real time elastography targeted biopsies in combination to a conventional 10 core biopsy in 1024 consecutive men. BJU Int. 2013. doi:10.1111/bju.12517. Salomon G, Drews N, Autier P, Beckmann A, Heinzer H, Hansen J, et al. Incremental detection rate of prostate cancer by HI-real time elastography targeted biopsies in combination to a conventional 10 core biopsy in 1024 consecutive men. BJU Int. 2013. doi:10.​1111/​bju.​12517.
32.••
Zurück zum Zitat Salomon GBL. 799 Subjective risk assessment for the diagnosis of prostate cancer using real-time elastography (RTE) prior to biopsy and assessment of real-time elastography for prostate cancer detection by comparing RTE-based and grey scale ultrasound biopsies. Eur Urol Suppl. 2012;11(1):e799. doi:10.1016/S1569-9056(12)60796-9.CrossRef Salomon GBL. 799 Subjective risk assessment for the diagnosis of prostate cancer using real-time elastography (RTE) prior to biopsy and assessment of real-time elastography for prostate cancer detection by comparing RTE-based and grey scale ultrasound biopsies. Eur Urol Suppl. 2012;11(1):e799. doi:10.​1016/​S1569-9056(12)60796-9.CrossRef
33.••
Zurück zum Zitat Pelzer AE, Heinzelbecker J, Weiss C, Fruhbauer D, Weidner AM, Kirchner M, et al. Real-time sonoelastography compared to magnetic resonance imaging using four different modalities at 3.0 T in the detection of prostate cancer: strength and weaknesses. Eur J Radiol. 2013;82(5):814–21.PubMedCrossRef Pelzer AE, Heinzelbecker J, Weiss C, Fruhbauer D, Weidner AM, Kirchner M, et al. Real-time sonoelastography compared to magnetic resonance imaging using four different modalities at 3.0 T in the detection of prostate cancer: strength and weaknesses. Eur J Radiol. 2013;82(5):814–21.PubMedCrossRef
34.
Zurück zum Zitat Moore CM, Kasivisvanathan V, Eggener S, Emberton M, Futterer JJ, Gill IS, et al. Standards of reporting for MRI-targeted biopsy studies (START) of the prostate: recommendations from an International Working Group. Eur Urol. 2013;64(4):544–52. doi:10.1016/j.eururo.2013.03.030.PubMedCrossRef Moore CM, Kasivisvanathan V, Eggener S, Emberton M, Futterer JJ, Gill IS, et al. Standards of reporting for MRI-targeted biopsy studies (START) of the prostate: recommendations from an International Working Group. Eur Urol. 2013;64(4):544–52. doi:10.​1016/​j.​eururo.​2013.​03.​030.PubMedCrossRef
Metadaten
Titel
Real-Time Elastography for the Detection of Prostate Cancer
verfasst von
Georg Salomon
Jonas Schiffmann
Publikationsdatum
01.03.2014
Verlag
Springer US
Erschienen in
Current Urology Reports / Ausgabe 3/2014
Print ISSN: 1527-2737
Elektronische ISSN: 1534-6285
DOI
https://doi.org/10.1007/s11934-013-0392-z

Weitere Artikel der Ausgabe 3/2014

Current Urology Reports 3/2014 Zur Ausgabe

Female Urology (K Kobashi, Section Editor)

Fecal Incontinence: The Role of the Urologist

New Imaging Techniques (A Atala and A Rastinehad, Section Editors)

Role of Multiparametric Magnetic Resonance Imaging in the Diagnosis of Prostate Cancer

New Imaging Techniques (A Atala and A Rastinehad, Section Editors)

The Role of Imaging in the Active Surveillance of Small Renal Masses

New Imaging Techniques (A Atala and A Rastinehad, Section Editors)

Lymphotropic Nanoparticle-enhanced MRI in Prostate Cancer: Value and Therapeutic Potential

Update Urologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.