Abstract

It has often been assumed rotational kinematics are improved with mobile-bearing TKA designs as the terms mobile-bearing and rotating platform imply. We tested this assumption by assessing the in vivo axial rotation magnitudes and patterns of 527 knees implanted with 12 different mobile-bearing TKA designs. Implants were grouped and compared by type—posterior stabilized (PS), posterior cruciate retaining (PCR), and posterior cruciate sacrificing (PCS)—and by specific design. We hypothesized all three mobile-bearing types (PS, PCR, and PCS) would achieve greater than 10° average axial rotation and we would find no differences in axial rotation between types. Only 14% of PS knees, 3% of PCS knees, and 17% of PCR knees attained greater than 10° axial rotation when measured from 0° to 90°. The percentage of PCS knees with greater than 10° axial rotation was less compared with the other two groups. Axial rotation averaged 4.3°, 2.5°, and 3.8° for the PS, PCS, and PCR knees, respectively. Incidences of reverse rotation were observed in 17% of PS knees, 32% of PCS knees, and 28% of PCR knees. Compared with the PCS group, the PS group achieved greater average axial rotation and had a lower percentage of knees displaying incidences of reverse rotation. The data refuted the hypotheses.
Literatur
1.
Zurück zum Zitat Asano T, Akagi M, Tanaka K, Tamura J, Nakamura T. In vivo three-dimensional knee kinematics using a biplanar image-matching technique. Clin Orthop Relat Res. 2001;388:157–166.PubMedCrossRef Asano T, Akagi M, Tanaka K, Tamura J, Nakamura T. In vivo three-dimensional knee kinematics using a biplanar image-matching technique. Clin Orthop Relat Res. 2001;388:157–166.PubMedCrossRef
2.
Zurück zum Zitat Banks SA, Hodge WA. Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res. 2004;426:187–193.PubMedCrossRef Banks SA, Hodge WA. Implant design affects knee arthroplasty kinematics during stair-stepping. Clin Orthop Relat Res. 2004;426:187–193.PubMedCrossRef
3.
Zurück zum Zitat Delport HP, Banks SA, De Schepper J, Bellemans J. A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br. 2006;88:1016–1021.PubMedCrossRef Delport HP, Banks SA, De Schepper J, Bellemans J. A kinematic comparison of fixed- and mobile-bearing knee replacements. J Bone Joint Surg Br. 2006;88:1016–1021.PubMedCrossRef
4.
Zurück zum Zitat Dennis DA, Komistek RD, Hoff WA, Gabriel SM. In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res. 1996;331:107–117.PubMedCrossRef Dennis DA, Komistek RD, Hoff WA, Gabriel SM. In vivo knee kinematics derived using an inverse perspective technique. Clin Orthop Relat Res. 1996;331:107–117.PubMedCrossRef
5.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR. In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res. 2003;410:114–130.PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR. In vivo fluoroscopic analysis of fixed-bearing total knee replacements. Clin Orthop Relat Res. 2003;410:114–130.PubMedCrossRef
6.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB. Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res. 2003;416:37–57.PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR, Haas BD, Stiehl JB. Multicenter determination of in vivo kinematics after total knee arthroplasty. Clin Orthop Relat Res. 2003;416:37–57.PubMedCrossRef
7.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A. Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate? Clin Orthop Relat Res. 2005;440:88–95.PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A. Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate? Clin Orthop Relat Res. 2005;440:88–95.PubMedCrossRef
8.
Zurück zum Zitat Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A. A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res. 2004;428:180–189.PubMedCrossRef Dennis DA, Komistek RD, Mahfouz MR, Walker SA, Tucker A. A multicenter analysis of axial femorotibial rotation after total knee arthroplasty. Clin Orthop Relat Res. 2004;428:180–189.PubMedCrossRef
9.
Zurück zum Zitat Dennis DA, Mahfouz MR, Komistek RD, Hoff W. In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech. 2005;38:241–253.PubMedCrossRef Dennis DA, Mahfouz MR, Komistek RD, Hoff W. In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics. J Biomech. 2005;38:241–253.PubMedCrossRef
10.
Zurück zum Zitat D’Lima DD, Trice M, Urquhart AG, Colwell CW Jr. Comparison between the kinematics of fixed and rotating bearing knee prostheses. Clin Orthop Relat Res. 2000;380:151–157.PubMedCrossRef D’Lima DD, Trice M, Urquhart AG, Colwell CW Jr. Comparison between the kinematics of fixed and rotating bearing knee prostheses. Clin Orthop Relat Res. 2000;380:151–157.PubMedCrossRef
11.
Zurück zum Zitat Elias JJ, Kumagai M, Mitchell I, Mizuno Y, Mattessich SM, Webb JD, Chao EY. In vitro kinematic patterns are similar for a fixed platform and a mobile-bearing prosthesis. J Arthroplasty. 2002;17:467–474.PubMedCrossRef Elias JJ, Kumagai M, Mitchell I, Mizuno Y, Mattessich SM, Webb JD, Chao EY. In vitro kinematic patterns are similar for a fixed platform and a mobile-bearing prosthesis. J Arthroplasty. 2002;17:467–474.PubMedCrossRef
12.
Zurück zum Zitat Komistek RD, Dennis DA, Mahfouz M. In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res. 2003;410:69–81.PubMedCrossRef Komistek RD, Dennis DA, Mahfouz M. In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res. 2003;410:69–81.PubMedCrossRef
13.
Zurück zum Zitat Mahfouz MR, Hoff WA, Komistek RD, Dennis DA. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging. 2003;22:1561–1574.PubMedCrossRef Mahfouz MR, Hoff WA, Komistek RD, Dennis DA. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging. 2003;22:1561–1574.PubMedCrossRef
14.
Zurück zum Zitat Mahfouz MR, Komistek RD, Dennis DA, Hoff WA. In vivo assessment of the kinematics in normal and anterior cruciate ligament-deficient knees. J Bone Joint Surg Am. 2004;86(Suppl 2):56–61.PubMed Mahfouz MR, Komistek RD, Dennis DA, Hoff WA. In vivo assessment of the kinematics in normal and anterior cruciate ligament-deficient knees. J Bone Joint Surg Am. 2004;86(Suppl 2):56–61.PubMed
15.
Zurück zum Zitat Most E, Li G, Schule S, Sultan P, Park SE, Zayontz S, Rubash HE. The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop Relat Res. 2003;416:197–207.PubMedCrossRef Most E, Li G, Schule S, Sultan P, Park SE, Zayontz S, Rubash HE. The kinematics of fixed- and mobile-bearing total knee arthroplasty. Clin Orthop Relat Res. 2003;416:197–207.PubMedCrossRef
16.
Zurück zum Zitat Nilsson KG, Karrholm J, Gadegaard P. Abnormal kinematics of the artificial knee. Roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS knees. Acta Orthop Scand. 1991;62:440–446.PubMedCrossRef Nilsson KG, Karrholm J, Gadegaard P. Abnormal kinematics of the artificial knee. Roentgen stereophotogrammetric analysis of 10 Miller-Galante and five New Jersey LCS knees. Acta Orthop Scand. 1991;62:440–446.PubMedCrossRef
17.
Zurück zum Zitat Oakeshott R, Stiehl JB, Komistek RA, Anderson DT, Haas BD. Kinematic analysis of a posterior cruciate retaining mobile-bearing total knee arthroplasty. J Arthroplasty. 2003;18:1029–1037.PubMedCrossRef Oakeshott R, Stiehl JB, Komistek RA, Anderson DT, Haas BD. Kinematic analysis of a posterior cruciate retaining mobile-bearing total knee arthroplasty. J Arthroplasty. 2003;18:1029–1037.PubMedCrossRef
18.
Zurück zum Zitat Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M. In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res. 2004;418:184–190.PubMedCrossRef Ranawat CS, Komistek RD, Rodriguez JA, Dennis DA, Anderle M. In vivo kinematics for fixed and mobile-bearing posterior stabilized knee prostheses. Clin Orthop Relat Res. 2004;418:184–190.PubMedCrossRef
19.
Zurück zum Zitat Russo A, Montagna L, Bragonzoni L, Visani A, Marcacci M. Changes in knee motion over the first 3 years with a mobile-bearing prosthesis. Knee. 2006;13:301–306.PubMedCrossRef Russo A, Montagna L, Bragonzoni L, Visani A, Marcacci M. Changes in knee motion over the first 3 years with a mobile-bearing prosthesis. Knee. 2006;13:301–306.PubMedCrossRef
20.
Zurück zum Zitat Saari T, Uvehammer J, Carlsson LV, Herberts P, Regner L, Karrholm J. Kinematics of three variations of the Freeman-Samuelson total knee prosthesis. Clin Orthop Relat Res. 2003;410:235–247.PubMedCrossRef Saari T, Uvehammer J, Carlsson LV, Herberts P, Regner L, Karrholm J. Kinematics of three variations of the Freeman-Samuelson total knee prosthesis. Clin Orthop Relat Res. 2003;410:235–247.PubMedCrossRef
21.
Zurück zum Zitat Stiehl JB, Dennis DA, Komistek RD, Keblish PA. In vivo kinematic analysis of a mobile-bearing total knee prosthesis. Clin Orthop Relat Res. 1997;345:60–66.PubMedCrossRef Stiehl JB, Dennis DA, Komistek RD, Keblish PA. In vivo kinematic analysis of a mobile-bearing total knee prosthesis. Clin Orthop Relat Res. 1997;345:60–66.PubMedCrossRef
22.
Zurück zum Zitat Sugita T, Sato K, Komistek RD, Mahfouz MR, Maeda I, Sano T. In vivo determination of knee kinematics for Japanese subjects having either a low contact stress rotating platform or an anteroposterior glide total knee arthroplasty. J Arthroplasty. 2005;20:154–161.PubMedCrossRef Sugita T, Sato K, Komistek RD, Mahfouz MR, Maeda I, Sano T. In vivo determination of knee kinematics for Japanese subjects having either a low contact stress rotating platform or an anteroposterior glide total knee arthroplasty. J Arthroplasty. 2005;20:154–161.PubMedCrossRef
23.
Zurück zum Zitat Wasielewski RC, Galat DD, Komistek RD. An intraoperative pressure-measuring device used in total knee arthroplasties and its kinematic correlations. Clin Orthop Relat Res. 2004;427:171–178.PubMedCrossRef Wasielewski RC, Galat DD, Komistek RD. An intraoperative pressure-measuring device used in total knee arthroplasties and its kinematic correlations. Clin Orthop Relat Res. 2004;427:171–178.PubMedCrossRef
24.
Zurück zum Zitat Watanabe T, Yamazaki T, Sugamoto K, Tomita T, Hashimoto H, Maeda D, Tamura S, Ochi T, Yoshikawa H. In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion. J Orthop Res. 2004;22:1044–1049.PubMedCrossRef Watanabe T, Yamazaki T, Sugamoto K, Tomita T, Hashimoto H, Maeda D, Tamura S, Ochi T, Yoshikawa H. In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion. J Orthop Res. 2004;22:1044–1049.PubMedCrossRef
Metadaten
Titel
Lack of Axial Rotation in Mobile-bearing Knee Designs
verfasst von
Ray C. Wasielewski, MD, MS
Richard D. Komistek, PhD
Sumesh M. Zingde, MS
Kate C. Sheridan, BS
Mohamed R. Mahfouz, PhD
Publikationsdatum
01.11.2008
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 11/2008
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0354-9

Weitere Artikel der Ausgabe 11/2008

Clinical Orthopaedics and Related Research® 11/2008 Zur Ausgabe

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Diagnosis of Infected Total Knee: Findings of a Multicenter Database

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Computer Navigation-assisted versus Minimally Invasive TKA

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Polyethylene Wear Is Influenced by Manufacturing Technique in Modular TKA

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Less Invasive TKA

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Men versus Women

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.