Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 1/2011

01.01.2011 | Symposium: Papers Presented at the Annual Meetings of the Knee Society

Wear Damage in Mobile-bearing TKA is as Severe as That in Fixed-bearing TKA

verfasst von: Natalie H. Kelly, BS, Rose H. Fu, BS, Timothy M. Wright, PhD, Douglas E. Padgett, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

Background

Mobile-bearing TKAs reportedly have no clinical superiority over fixed-bearing TKAs, but a potential benefit is improved polyethylene wear behavior.

Questions/purposes

We asked whether extent of damage and wear patterns would be less severe on retrieved mobile-bearing TKAs than on fixed-bearing TKAs and if correlations with patient demographics could explain differences in extent or locations of damage.

Methods

We performed damage grading and mapping of 48 mobile-bearing TKAs retrieved due to osteolysis/loosening, infection, stiffness, instability or malpositioning. Visual grading used stereomicroscopy to identify damage, and a grade was assigned based on extent and severity. Each damage mode was then mapped onto a photograph of the implant surface, and the area affected was calculated.

Results

Marked wear damage occurred on both surfaces, with burnishing, scratching, and pitting the dominant modes. Damage occurred over a large portion of both surfaces, exceeding the available articular borders in nearly 30% of implants. Wear of mobile-bearing surfaces included marked third-body debris. Damage on tibiofemoral and mobile-bearing surfaces was not correlated with patient BMI or component alignment. Damage on mobile-bearing surfaces was positively correlated with length of implantation and was greater in implants removed for osteolysis or instability than in those removed for stiffness or infection.

Conclusions

Each bearing surface in mobile-bearing implants was damaged to an extent similar to that in fixed-bearing implants, making the combined damage score higher than that for fixed-bearing implants. Mobile-bearing TKAs did not improve wear damage, providing another argument against the superiority of these implants over fixed-bearing implants.
Literatur
1.
Zurück zum Zitat Atwood SA, Currier JH, Mayor MB, Collier JP, Van Citters DW, Kennedy FE. Clinical wear measurement on low contact stress rotating platform knee bearings. J Arthroplasty. 2008;23:431–440.CrossRefPubMed Atwood SA, Currier JH, Mayor MB, Collier JP, Van Citters DW, Kennedy FE. Clinical wear measurement on low contact stress rotating platform knee bearings. J Arthroplasty. 2008;23:431–440.CrossRefPubMed
2.
Zurück zum Zitat Buechel FF, Pappas MJ. The New Jersey Low-Contact-Stress Knee Replacement System: biomechanical rationale and review of the first 123 cemented cases. Arch Orthop Trauma Surg. 1986;105:197–204.CrossRefPubMed Buechel FF, Pappas MJ. The New Jersey Low-Contact-Stress Knee Replacement System: biomechanical rationale and review of the first 123 cemented cases. Arch Orthop Trauma Surg. 1986;105:197–204.CrossRefPubMed
3.
Zurück zum Zitat Chouteau J, Lerat JL, Testa R, Moyen B, Fessy MH, Banks SA. Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty. Orthop Traumatol Surg Res. 2009;95:254–259.CrossRefPubMed Chouteau J, Lerat JL, Testa R, Moyen B, Fessy MH, Banks SA. Mobile-bearing insert translational and rotational kinematics in a PCL-retaining total knee arthroplasty. Orthop Traumatol Surg Res. 2009;95:254–259.CrossRefPubMed
4.
Zurück zum Zitat Cottrell JM, Townsend E, Lipman J, Sculco TP, Wright TM. Bearing surface design changes affect contact patterns in total knee arthroplasty. Clin Orthop Relat Res. 2007;464:127–131.PubMed Cottrell JM, Townsend E, Lipman J, Sculco TP, Wright TM. Bearing surface design changes affect contact patterns in total knee arthroplasty. Clin Orthop Relat Res. 2007;464:127–131.PubMed
5.
Zurück zum Zitat Engh GA, Zimmerman RL, Parks NL, Engh CA. Analysis of wear in retrieved mobile and fixed bearing knee inserts. J Arthroplasty. 2009;24(Suppl):28–32.CrossRefPubMed Engh GA, Zimmerman RL, Parks NL, Engh CA. Analysis of wear in retrieved mobile and fixed bearing knee inserts. J Arthroplasty. 2009;24(Suppl):28–32.CrossRefPubMed
6.
Zurück zum Zitat Fehring TK, Murphy JA, Hayes TD, Roberts DW, Pomeroy DL, Griffin WL. Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements. Clin Orthop Relat Res. 2004;428:40–50. Fehring TK, Murphy JA, Hayes TD, Roberts DW, Pomeroy DL, Griffin WL. Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements. Clin Orthop Relat Res. 2004;428:40–50.
7.
Zurück zum Zitat Garcia RM, Kraay MJ, Messerschmitt PJ, Goldberg VM, Rimnac CM. Analysis of retrieved ultra-high-molecular-weight polyethylene tibial components from rotating-platform total knee arthroplasty. J Arthroplasty. 2009;24:131–138.CrossRefPubMed Garcia RM, Kraay MJ, Messerschmitt PJ, Goldberg VM, Rimnac CM. Analysis of retrieved ultra-high-molecular-weight polyethylene tibial components from rotating-platform total knee arthroplasty. J Arthroplasty. 2009;24:131–138.CrossRefPubMed
8.
Zurück zum Zitat Gioe TJ, Glynn J, Sembrano J, Suthers K, Santos ER, Singh J. Mobile and fixed-bearing (all-polyethylene tibial component) total knee arthroplasty designs: a prospective randomized trial. J Bone Joint Surg Am. 2009;91:2104–2112.CrossRefPubMed Gioe TJ, Glynn J, Sembrano J, Suthers K, Santos ER, Singh J. Mobile and fixed-bearing (all-polyethylene tibial component) total knee arthroplasty designs: a prospective randomized trial. J Bone Joint Surg Am. 2009;91:2104–2112.CrossRefPubMed
9.
Zurück zum Zitat Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res. 1983;17:829–842.CrossRefPubMed Hood RW, Wright TM, Burstein AH. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. J Biomed Mater Res. 1983;17:829–842.CrossRefPubMed
10.
Zurück zum Zitat Kop AM, Swarts E. Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee. Acta Orthop. 2007;78:364–370.CrossRefPubMed Kop AM, Swarts E. Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior-Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee. Acta Orthop. 2007;78:364–370.CrossRefPubMed
11.
Zurück zum Zitat Lu YC, Huang CH, Chang TK, Ho FY, Cheng CK, Huang CH. Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses. J Bone Joint Surg Br. 2010;92:500–507.CrossRefPubMed Lu YC, Huang CH, Chang TK, Ho FY, Cheng CK, Huang CH. Wear-pattern analysis in retrieved tibial inserts of mobile-bearing and fixed-bearing total knee prostheses. J Bone Joint Surg Br. 2010;92:500–507.CrossRefPubMed
12.
Zurück zum Zitat Pagnano MW, Trousdale RT, Stuart MJ, Hanssen AD, Jacofsky DJ. Rotating platform knees did not improve patellar tracking: a prospective, randomized study of 240 primary total knee arthroplasties. Clin Orthop Relat Res. 2004;428:221–227.CrossRefPubMed Pagnano MW, Trousdale RT, Stuart MJ, Hanssen AD, Jacofsky DJ. Rotating platform knees did not improve patellar tracking: a prospective, randomized study of 240 primary total knee arthroplasties. Clin Orthop Relat Res. 2004;428:221–227.CrossRefPubMed
13.
Zurück zum Zitat Rawlinson JJ, Furman BD, Li S, Wright TM, Bartel DL. Retrieval, experimental, and computational assessment of the performance of total knee replacements. J Orthop Res. 2006;24:1384–1394.CrossRefPubMed Rawlinson JJ, Furman BD, Li S, Wright TM, Bartel DL. Retrieval, experimental, and computational assessment of the performance of total knee replacements. J Orthop Res. 2006;24:1384–1394.CrossRefPubMed
14.
Zurück zum Zitat Rohrbach M, Luem M, Ochsner PE. Patient and surgery related factors associated with fatigue type polyethylene wear on 49 PCA and DURACON retrievals at autopsy and revision. J Orthop Surg Res. 2008;3:8–17.CrossRefPubMed Rohrbach M, Luem M, Ochsner PE. Patient and surgery related factors associated with fatigue type polyethylene wear on 49 PCA and DURACON retrievals at autopsy and revision. J Orthop Surg Res. 2008;3:8–17.CrossRefPubMed
15.
Zurück zum Zitat Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7–13.CrossRefPubMed Sharkey PF, Hozack WJ, Rothman RH, Shastri S, Jacoby SM. Insall Award paper. Why are total knee arthroplasties failing today? Clin Orthop Relat Res. 2002;404:7–13.CrossRefPubMed
16.
Zurück zum Zitat Smith TO, Ejtehadi F, Nichols R, Davies L, Donell ST, Hing CB. Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2010;18:325–340.CrossRefPubMed Smith TO, Ejtehadi F, Nichols R, Davies L, Donell ST, Hing CB. Clinical and radiological outcomes of fixed- versus mobile-bearing total knee replacement: a meta-analysis. Knee Surg Sports Traumatol Arthrosc. 2010;18:325–340.CrossRefPubMed
17.
Zurück zum Zitat Wasielewski RC, Komistek RD, Zingde SM, Sheridan KC, Mahfouz MR. Lack of axial rotation in mobile-bearing knee designs. Clin Orthop Relat Res. 2008;466:2662–2668.CrossRefPubMed Wasielewski RC, Komistek RD, Zingde SM, Sheridan KC, Mahfouz MR. Lack of axial rotation in mobile-bearing knee designs. Clin Orthop Relat Res. 2008;466:2662–2668.CrossRefPubMed
18.
Zurück zum Zitat Wright TM. Knee biomechanics and implant design. In: Callaghan J, Rosenberg A, Rubash H, Simonian P, Wickiewicz T, eds. The Adult Knee. Baltimore, MD: Lippincott Williams & Wilkins; 2003:145–162. Wright TM. Knee biomechanics and implant design. In: Callaghan J, Rosenberg A, Rubash H, Simonian P, Wickiewicz T, eds. The Adult Knee. Baltimore, MD: Lippincott Williams & Wilkins; 2003:145–162.
19.
Zurück zum Zitat Wright TM, Rimnac CM, Faris PM, Bansal M. Analysis of surface damage in retrieved carbon fiber-reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements. J Bone Joint Surg Am. 1988;70:1312–1319.PubMed Wright TM, Rimnac CM, Faris PM, Bansal M. Analysis of surface damage in retrieved carbon fiber-reinforced and plain polyethylene tibial components from posterior stabilized total knee replacements. J Bone Joint Surg Am. 1988;70:1312–1319.PubMed
20.
Zurück zum Zitat Wright TM, Rimnac CM, Stulberg D, Mintz L, Tsao AK, Klein RW, McCrae C. Wear of polyethylene in total joint replacements: observations from retrieved PCA knee implants. Clin Orthop Relat Res. 1992;276:126–134.PubMed Wright TM, Rimnac CM, Stulberg D, Mintz L, Tsao AK, Klein RW, McCrae C. Wear of polyethylene in total joint replacements: observations from retrieved PCA knee implants. Clin Orthop Relat Res. 1992;276:126–134.PubMed
Metadaten
Titel
Wear Damage in Mobile-bearing TKA is as Severe as That in Fixed-bearing TKA
verfasst von
Natalie H. Kelly, BS
Rose H. Fu, BS
Timothy M. Wright, PhD
Douglas E. Padgett, MD
Publikationsdatum
01.01.2011
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 1/2011
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1557-4

Weitere Artikel der Ausgabe 1/2011

Clinical Orthopaedics and Related Research® 1/2011 Zur Ausgabe

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Hospital Economics of Primary Total Knee Arthroplasty at a Teaching Hospital

Symposium: Papers Presented at the Annual Meetings of the Knee Society

In Vitro Quantification of Wear in Tibial Inserts Using Microcomputed Tomography

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.