Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 2/2012

01.02.2012 | Symposium: Papers Presented at the Annual Meetings of The Hip Society

Stable Fixation of Short-stem Femoral Implants in Patients 70 Years and Older

verfasst von: Ronak M. Patel, MD, Matthew C. Smith, MD, Chase C. Woodward, BA, S. David Stulberg, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 2/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Limitations of conventional uncemented femoral stems persist, including proximal-distal mismatch, nonideal load transfer, loss of bone, and difficulties with minimally invasive surgery. Metaphyseal-engaging short-stem implants have been designed to address these issues in THA. While these devices have been studied in younger patients, it is unclear whether they offer advantages in older patients.

Questions/purposes

We asked whether the stability and bony ingrowth of an off-the-shelf short stem in patients 70 years and older were similar to those achieved in patients younger than 70 years at 2-year followup. Furthermore, we asked whether pain and function scores were affected by age, bone quality, or varus alignment.

Patients and Methods

We retrospectively reviewed 60 patients (65 hips) 70 years and older (mean, 75 years; range, 70–86 years) treated with an uncemented short stem (range, 90–105 mm). We compared radiographic alignment, stability, and bony ingrowth, as well as Harris hip scores and WOMAC pain scores, to a cohort of 89 patients (91 hips) younger than 70 years. Minimum followup was 24 months (mean, 35 months; range, 24–60 months).

Results

Radiographs showed proximal bony ingrowth and stable fixation of all implants. Average Harris hip score at last followup was 88 (range, 70–100) for the 70 years and older cohort and 93 (range, 70–100) for younger than 70 years cohort; no patients reported thigh pain. Postoperative WOMAC scores averaged 6 (range, 0–43) and 5 (range, 0–25), respectively.

Conclusions

Short-stem implants provide solid, dependable fixation in osteoporotic bone at minimum 2-year followup, while meeting some of the limitations in conventional primary THA.

Level of Evidence

Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Baker PN, McMurtry IA, Chuter G, Port A, Anderson J. THA with the ABG I prosthesis at 15 years: excellent survival with minimal osteolysis. Clin Orthop Relat Res. 2010;468:1855–1861.PubMedCrossRef Baker PN, McMurtry IA, Chuter G, Port A, Anderson J. THA with the ABG I prosthesis at 15 years: excellent survival with minimal osteolysis. Clin Orthop Relat Res. 2010;468:1855–1861.PubMedCrossRef
2.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed
3.
Zurück zum Zitat Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB. Cementless double-tapered total hip arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004;19:288–295.PubMedCrossRef Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB. Cementless double-tapered total hip arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004;19:288–295.PubMedCrossRef
4.
Zurück zum Zitat Berend ME, Smith A, Meding JB, Ritter MA, Lynch T, Davis K. Long-term outcome and risk factors of proximal femoral fracture in uncemented and cemented total hip arthroplasty in 2551 hips. J Arthroplasty. 2006;21:53–59.CrossRef Berend ME, Smith A, Meding JB, Ritter MA, Lynch T, Davis K. Long-term outcome and risk factors of proximal femoral fracture in uncemented and cemented total hip arthroplasty in 2551 hips. J Arthroplasty. 2006;21:53–59.CrossRef
6.
Zurück zum Zitat Brown TE, Larson B, Shen F, Moskal JT. Thigh pain after cementless total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg. 2002;10:385–392.PubMed Brown TE, Larson B, Shen F, Moskal JT. Thigh pain after cementless total hip arthroplasty: evaluation and management. J Am Acad Orthop Surg. 2002;10:385–392.PubMed
7.
Zurück zum Zitat Burt CF, Garvin KL, Otterberg ET, Jardon OM. A femoral component inserted without cement in total hip arthroplasty: a study of the Tri-Lock component with an average ten-year duration of follow-up. J Bone Joint Surg Am. 1998;80:952–960.PubMed Burt CF, Garvin KL, Otterberg ET, Jardon OM. A femoral component inserted without cement in total hip arthroplasty: a study of the Tri-Lock component with an average ten-year duration of follow-up. J Bone Joint Surg Am. 1998;80:952–960.PubMed
8.
Zurück zum Zitat Callaghan JJ, Rosenberg AG, Rubash HE. The Adult Hip. 2nd ed. Philadephia, PA: Lippincott Williams & Wilkins; 2007. Callaghan JJ, Rosenberg AG, Rubash HE. The Adult Hip. 2nd ed. Philadephia, PA: Lippincott Williams & Wilkins; 2007.
9.
Zurück zum Zitat Capello WN, D’Antonio JA, Jaffe WL, Geesink RG, Manley MT, Feinberg JR. Hydroxyapatite-coated femoral components: 15-year minimum followup. Clin Orthop Relat Res. 2006;453:75–80.PubMedCrossRef Capello WN, D’Antonio JA, Jaffe WL, Geesink RG, Manley MT, Feinberg JR. Hydroxyapatite-coated femoral components: 15-year minimum followup. Clin Orthop Relat Res. 2006;453:75–80.PubMedCrossRef
10.
Zurück zum Zitat Capello WN, D’Antonio JA, Manley MT, Feinberg JR. Hydroxyapatite in total hip arthroplasty: clinical results and critical issues. Clin Orthop Relat Res. 1998;355:200–211.PubMedCrossRef Capello WN, D’Antonio JA, Manley MT, Feinberg JR. Hydroxyapatite in total hip arthroplasty: clinical results and critical issues. Clin Orthop Relat Res. 1998;355:200–211.PubMedCrossRef
11.
Zurück zum Zitat Cohen B, Rushton N. Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty. J Bone Joint Surg Br. 1995;77:479–483.PubMed Cohen B, Rushton N. Accuracy of DEXA measurement of bone mineral density after total hip arthroplasty. J Bone Joint Surg Br. 1995;77:479–483.PubMed
12.
Zurück zum Zitat Corten K, Bourne RB, Charron KD, Au K, Rorabeck CH. What works best, a cemented or cementless primary total hip arthroplasty? Minimum 17-year followup of a randomized controlled trial. Clin Orthop Relat Res. 2011;469:209–217.PubMedCrossRef Corten K, Bourne RB, Charron KD, Au K, Rorabeck CH. What works best, a cemented or cementless primary total hip arthroplasty? Minimum 17-year followup of a randomized controlled trial. Clin Orthop Relat Res. 2011;469:209–217.PubMedCrossRef
13.
Zurück zum Zitat Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.PubMedCrossRef Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.PubMedCrossRef
14.
Zurück zum Zitat Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants: the femoral side. Clin Orthop Relat Res. 1990;261:63–81.PubMed Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants: the femoral side. Clin Orthop Relat Res. 1990;261:63–81.PubMed
15.
Zurück zum Zitat Engh CA Jr, McAuley JP, Sychterz CJ, Sacco ME, Engh CA Sr. The accuracy and reproducibility of radiographic assessment of stress-shielding: a postmortem analysis. J Bone Joint Surg Am. 2000;82:1414–1420.PubMed Engh CA Jr, McAuley JP, Sychterz CJ, Sacco ME, Engh CA Sr. The accuracy and reproducibility of radiographic assessment of stress-shielding: a postmortem analysis. J Bone Joint Surg Am. 2000;82:1414–1420.PubMed
16.
Zurück zum Zitat Fitzgerald RH Jr, Brindley GW, Kavanagh BF. The uncemented total hip arthroplasty: intraoperative femoral fractures. Clin Orthop Relat Res. 1988;235:61–66.PubMed Fitzgerald RH Jr, Brindley GW, Kavanagh BF. The uncemented total hip arthroplasty: intraoperative femoral fractures. Clin Orthop Relat Res. 1988;235:61–66.PubMed
17.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed
18.
Zurück zum Zitat Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
19.
Zurück zum Zitat Harris WH. Etiology of osteoarthritis of the hip. Clin Orthop Relat Res. 1986;213:20–33.PubMed Harris WH. Etiology of osteoarthritis of the hip. Clin Orthop Relat Res. 1986;213:20–33.PubMed
20.
Zurück zum Zitat Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996;333:217–225.PubMedCrossRef Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996;333:217–225.PubMedCrossRef
21.
Zurück zum Zitat Jasty M, Henshaw RM, O’Connor DO, Harris WH. High assembly strains and femoral fractures produced during insertion of uncemented femoral components: a cadaver study. J Arthroplasty. 1993;8:479–487.PubMedCrossRef Jasty M, Henshaw RM, O’Connor DO, Harris WH. High assembly strains and femoral fractures produced during insertion of uncemented femoral components: a cadaver study. J Arthroplasty. 1993;8:479–487.PubMedCrossRef
22.
Zurück zum Zitat Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement: a standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.PubMed Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement: a standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.PubMed
23.
Zurück zum Zitat Karrholm J. Roentgen stereophotogrammetry: review of orthopedic applications. Acta Orthop Scand. 1989;60:491–503.PubMedCrossRef Karrholm J. Roentgen stereophotogrammetry: review of orthopedic applications. Acta Orthop Scand. 1989;60:491–503.PubMedCrossRef
24.
Zurück zum Zitat Keisu KS, Orozco F, Sharkey PF, Hozack WJ, Rothman RH, McGuigan FX. Primary cementless total hip arthroplasty in octogenarians: two to eleven-year follow-up. J Bone Joint Surg Am. 2001;83:359–363.PubMedCrossRef Keisu KS, Orozco F, Sharkey PF, Hozack WJ, Rothman RH, McGuigan FX. Primary cementless total hip arthroplasty in octogenarians: two to eleven-year follow-up. J Bone Joint Surg Am. 2001;83:359–363.PubMedCrossRef
25.
Zurück zum Zitat Kelly SJ, Robbins CE, Bierbaum BE, Bono JV, Ward DM. Use of a hydroxyapatite-coated stem in patients with Dorr Type C femoral bone. Clin Orthop Relat Res. 2007;465:112–116.PubMed Kelly SJ, Robbins CE, Bierbaum BE, Bono JV, Ward DM. Use of a hydroxyapatite-coated stem in patients with Dorr Type C femoral bone. Clin Orthop Relat Res. 2007;465:112–116.PubMed
26.
Zurück zum Zitat Khalily C, Lester DK. Results of a tapered cementless femoral stem implanted in varus. J Arthroplasty. 2002;17:463–466.PubMedCrossRef Khalily C, Lester DK. Results of a tapered cementless femoral stem implanted in varus. J Arthroplasty. 2002;17:463–466.PubMedCrossRef
27.
Zurück zum Zitat Kirsh G, Roffman M, Kligman M. Hydroxyapatite-coated total hip replacements in patients 65 years of age and over. Bull Hosp Jt Dis. 2001;60:5–9.PubMed Kirsh G, Roffman M, Kligman M. Hydroxyapatite-coated total hip replacements in patients 65 years of age and over. Bull Hosp Jt Dis. 2001;60:5–9.PubMed
28.
Zurück zum Zitat Konstantoulakis C, Anastopoulos G, Papaeliou A, Tsoutsanis A, Asimakopoulos A. Uncemented total hip arthroplasty in the elderly. Int Orthop. 1999;23:334–336.PubMedCrossRef Konstantoulakis C, Anastopoulos G, Papaeliou A, Tsoutsanis A, Asimakopoulos A. Uncemented total hip arthroplasty in the elderly. Int Orthop. 1999;23:334–336.PubMedCrossRef
29.
Zurück zum Zitat Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am. 2005;87:1487–1497.PubMedCrossRef Kurtz S, Mowat F, Ong K, Chan N, Lau E, Halpern M. Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002. J Bone Joint Surg Am. 2005;87:1487–1497.PubMedCrossRef
30.
Zurück zum Zitat Lakstein D, Backstein D, Safir O, Kosashvili Y, Gross AE. Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res. 2010;468:1310–1315.PubMedCrossRef Lakstein D, Backstein D, Safir O, Kosashvili Y, Gross AE. Revision total hip arthroplasty with a porous-coated modular stem: 5 to 10 years follow-up. Clin Orthop Relat Res. 2010;468:1310–1315.PubMedCrossRef
31.
Zurück zum Zitat Le D, Smith K, Tanzer D, Tanzer M. Modular femoral sleeve and stem implant provides long-term total hip survivorship. Clin Orthop Relat Res. 2011;469:508–513.PubMedCrossRef Le D, Smith K, Tanzer D, Tanzer M. Modular femoral sleeve and stem implant provides long-term total hip survivorship. Clin Orthop Relat Res. 2011;469:508–513.PubMedCrossRef
32.
Zurück zum Zitat Meding JB, Galley MR, Ritter MA. High survival of uncemented proximally porous-coated titanium alloy femoral stems in osteoporotic bone. Clin Orthop Relat Res. 2010;468:441–447.PubMedCrossRef Meding JB, Galley MR, Ritter MA. High survival of uncemented proximally porous-coated titanium alloy femoral stems in osteoporotic bone. Clin Orthop Relat Res. 2010;468:441–447.PubMedCrossRef
33.
Zurück zum Zitat Meding JB, Keating EM, Ritter MA, Faris PM, Berend ME. Minimum ten-year follow-up of a straight-stemmed, plasma-sprayed, titanium-alloy, uncemented femoral component in primary total hip arthroplasty. J Bone Joint Surg Am. 2004;86:92–97.PubMed Meding JB, Keating EM, Ritter MA, Faris PM, Berend ME. Minimum ten-year follow-up of a straight-stemmed, plasma-sprayed, titanium-alloy, uncemented femoral component in primary total hip arthroplasty. J Bone Joint Surg Am. 2004;86:92–97.PubMed
34.
Zurück zum Zitat Min BW, Song KS, Bae KC, Cho CH, Kang CH, Kim SY. The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplasty. 2008;23:418–423.PubMedCrossRef Min BW, Song KS, Bae KC, Cho CH, Kang CH, Kim SY. The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplasty. 2008;23:418–423.PubMedCrossRef
35.
Zurück zum Zitat Morrey BF. Short-stemmed uncemented femoral component for primary hip arthroplasty. Clin Orthop Relat Res. 1989;249:169–175.PubMed Morrey BF. Short-stemmed uncemented femoral component for primary hip arthroplasty. Clin Orthop Relat Res. 1989;249:169–175.PubMed
36.
Zurück zum Zitat Morrey BF. Joint Replacement Arthroplasty. New York, NY: Churchill Livingstone; 1991. Morrey BF. Joint Replacement Arthroplasty. New York, NY: Churchill Livingstone; 1991.
37.
Zurück zum Zitat Moyer JA, Metz CM, Callaghan JJ, Hennessy DW, Liu SS. Durability of second-generation extensively porous-coated stems in patients age 50 and younger. Clin Orthop Relat Res. 2010;468:448–453.PubMedCrossRef Moyer JA, Metz CM, Callaghan JJ, Hennessy DW, Liu SS. Durability of second-generation extensively porous-coated stems in patients age 50 and younger. Clin Orthop Relat Res. 2010;468:448–453.PubMedCrossRef
38.
Zurück zum Zitat Muirhead-Allwood SK, Sandiford N, Skinner JA, Hua J, Kabir C, Walker PS. Uncemented custom computer-assisted design and manufacture of hydroxyapatite-coated femoral components: survival at 10 to 17 years. J Bone Joint Surg Br. 2010;92: 1079–1084.PubMedCrossRef Muirhead-Allwood SK, Sandiford N, Skinner JA, Hua J, Kabir C, Walker PS. Uncemented custom computer-assisted design and manufacture of hydroxyapatite-coated femoral components: survival at 10 to 17 years. J Bone Joint Surg Br. 2010;92: 1079–1084.PubMedCrossRef
39.
Zurück zum Zitat Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Joint Surg Am. 1996;78:1214–1225.PubMed Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Joint Surg Am. 1996;78:1214–1225.PubMed
40.
Zurück zum Zitat Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS. The anatomic basis of femoral component design. Clin Orthop Relat Res. 1988;235:148–165.PubMed Noble PC, Alexander JW, Lindahl LJ, Yew DT, Granberry WM, Tullos HS. The anatomic basis of femoral component design. Clin Orthop Relat Res. 1988;235:148–165.PubMed
41.
Zurück zum Zitat Otani T, Whiteside LA. Failure of cementless fixation of the femoral component in total hip arthroplasty. Orthop Clin North Am. 1992;23:335–346.PubMed Otani T, Whiteside LA. Failure of cementless fixation of the femoral component in total hip arthroplasty. Orthop Clin North Am. 1992;23:335–346.PubMed
42.
Zurück zum Zitat Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty. 2004;19:151–156.PubMedCrossRef Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty. 2004;19:151–156.PubMedCrossRef
43.
Zurück zum Zitat Sah AP, Thornhill TS, Leboff MS, Glowacki J. Correlation of plain radiographic indices of the hip with quantitative bone mineral density. Osteoporos Int. 2007;18:1119–1126.PubMedCrossRef Sah AP, Thornhill TS, Leboff MS, Glowacki J. Correlation of plain radiographic indices of the hip with quantitative bone mineral density. Osteoporos Int. 2007;18:1119–1126.PubMedCrossRef
44.
Zurück zum Zitat Santori FS, Santori N. Mid-term results of a custom-made short proximal loading femoral component. J Bone Joint Surg Br. 2010;92:1231–1237.PubMed Santori FS, Santori N. Mid-term results of a custom-made short proximal loading femoral component. J Bone Joint Surg Br. 2010;92:1231–1237.PubMed
45.
Zurück zum Zitat Santori N, Albanese CV, Learmonth ID, Santori FS. Bone preservation with a conservative metaphyseal loading implant. Hip Int. 2006;16(Suppl 3):16–21.PubMed Santori N, Albanese CV, Learmonth ID, Santori FS. Bone preservation with a conservative metaphyseal loading implant. Hip Int. 2006;16(Suppl 3):16–21.PubMed
46.
Zurück zum Zitat Stulberg SD, Dolan M. The short stem: a thinking man’s alternative to surface replacement. Orthopedics. 2008;31:885–886.PubMedCrossRef Stulberg SD, Dolan M. The short stem: a thinking man’s alternative to surface replacement. Orthopedics. 2008;31:885–886.PubMedCrossRef
Metadaten
Titel
Stable Fixation of Short-stem Femoral Implants in Patients 70 Years and Older
verfasst von
Ronak M. Patel, MD
Matthew C. Smith, MD
Chase C. Woodward, BA
S. David Stulberg, MD
Publikationsdatum
01.02.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 2/2012
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-2063-z

Weitere Artikel der Ausgabe 2/2012

Clinical Orthopaedics and Related Research® 2/2012 Zur Ausgabe

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Factors Affecting Modular Acetabular Ceramic Liner Insertion: A Biomechanical Analysis

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Second-generation Modular Acetabular Components Provide Fixation at 10 to 16 Years

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Incidence of Contralateral THA After Index THA for Osteoarthritis

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Low Incidence of Groin Pain and Early Failure with Large Metal Articulation Total Hip Arthroplasty

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.