Skip to main content
Erschienen in: Clinical Orthopaedics and Related Research® 4/2012

01.04.2012 | Basic Research

Does Total Knee Arthroplasty Change Frontal Plane Knee Biomechanics During Gait?

verfasst von: Karl F. Orishimo, MS, Ian J. Kremenic, MEng, Ajit J. Deshmukh, MD, Stephen J. Nicholas, MD, Jose A. Rodriguez, MD

Erschienen in: Clinical Orthopaedics and Related Research® | Ausgabe 4/2012

Einloggen, um Zugang zu erhalten

Abstract

Background

Dynamic knee varus angle and adduction moments have been reported to be reduced after TKA. However, it is unclear whether this reduction is maintained long term.

Questions/purposes

We therefore asked whether (1) the dynamic knee adduction angle and moment remain reduced 1 year after TKA, (2) if changes in adduction moment are related to static alignment and varus angle during gait 6 months and 1 year after TKA, and (3) if these changes in loading pattern are related to changes in Knee Society scores.

Methods

We performed gait analysis on 15 patients (17 TKAs) before surgery and 6 months and 1 year after TKA. Weightbearing radiographs were used to assess coronal plane knee alignment.

Results

TKA corrected static knee alignment from 2.2° (2.5°) varus to 3.5° (2.7°) valgus at 6 months. Peak varus angle during gait was reduced from 9.7° (6.5°) to 3.6° (5.8°) at 6 months and 5.2° (7.6°) at 1 year. Peak adduction moment was reduced to 85% of the preoperative level at 6 months but increased to 94% of the preoperative level at 1 year. We observed a correlation between the increase in dynamic varus angle and increase in adduction moment from the 6-month to 1-year followups.

Conclusions

TKA improves knee adduction moment at 6 months, but this effect is lost with time (1 year).

Clinical Relevance

Despite restoration of static knee alignment, knee adduction moment remains high presumably predisposing to medial polyethylene wear as noted by retrieval studies.
Literatur
1.
Zurück zum Zitat Ahlback S. Osteoarthrosis of the knee: a radiographic investigation. Acta Radiol Diagn (Stockh). 1968;277(suppl):7–72. Ahlback S. Osteoarthrosis of the knee: a radiographic investigation. Acta Radiol Diagn (Stockh). 1968;277(suppl):7–72.
2.
Zurück zum Zitat Alnahdi AH, Zeni JA, Snyder-Mackler L. Gait after unilateral total knee arthroplasty: frontal plane analysis. J Orthop Res. 2011;29:647–652.PubMedCrossRef Alnahdi AH, Zeni JA, Snyder-Mackler L. Gait after unilateral total knee arthroplasty: frontal plane analysis. J Orthop Res. 2011;29:647–652.PubMedCrossRef
3.
Zurück zum Zitat Andriacchi TP. Dynamics of knee malalignment. Orthop Clin North Am. 1994;25:395–403.PubMed Andriacchi TP. Dynamics of knee malalignment. Orthop Clin North Am. 1994;25:395–403.PubMed
4.
Zurück zum Zitat Andriacchi TP, Stanwyck TS, Galante JO. Knee biomechanics and total knee replacement. J Arthroplasty. 1986;1:211–219.PubMedCrossRef Andriacchi TP, Stanwyck TS, Galante JO. Knee biomechanics and total knee replacement. J Arthroplasty. 1986;1:211–219.PubMedCrossRef
5.
Zurück zum Zitat Baliunas AJ, Hurwitz DE, Ryals AB, Karrar A, Case JP, Block JA, Andriacchi TP. Increased knee joint loads during walking are present in subjects with knee osteoarthritis. Osteoarthritis Cartilage. 2002;10:573–579.PubMedCrossRef Baliunas AJ, Hurwitz DE, Ryals AB, Karrar A, Case JP, Block JA, Andriacchi TP. Increased knee joint loads during walking are present in subjects with knee osteoarthritis. Osteoarthritis Cartilage. 2002;10:573–579.PubMedCrossRef
6.
Zurück zum Zitat Cameron HU. Tibial component wear in total knee replacement. Clin Orthop Relat Res. 1994;309:29–32.PubMed Cameron HU. Tibial component wear in total knee replacement. Clin Orthop Relat Res. 1994;309:29–32.PubMed
7.
Zurück zum Zitat Collier MB, Engh CA Jr, McAuley JP, Engh GA. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg Am. 2007;89:1306–1314.PubMedCrossRef Collier MB, Engh CA Jr, McAuley JP, Engh GA. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg Am. 2007;89:1306–1314.PubMedCrossRef
8.
Zurück zum Zitat Erhart JC, Mündermann A, Elspas B, Giori NJ, Andriacchi TP. A variable-stiffness shoe lowers the knee adduction moment in subjects with symptoms of medial compartment knee osteoarthritis. J Biomech. 2008;41:2720–2725.PubMedCrossRef Erhart JC, Mündermann A, Elspas B, Giori NJ, Andriacchi TP. A variable-stiffness shoe lowers the knee adduction moment in subjects with symptoms of medial compartment knee osteoarthritis. J Biomech. 2008;41:2720–2725.PubMedCrossRef
9.
Zurück zum Zitat Haim A, Rozen N, Dekel S, Halperin N, Wolf A. Control of knee coronal plane moment via modulation of center of pressure: a prospective gait analysis study. J Biomech. 2008;41:3010–3016.PubMedCrossRef Haim A, Rozen N, Dekel S, Halperin N, Wolf A. Control of knee coronal plane moment via modulation of center of pressure: a prospective gait analysis study. J Biomech. 2008;41:3010–3016.PubMedCrossRef
10.
Zurück zum Zitat Hatfield GL, Hubley-Kozey CL, Astephen Wilson JL, Dunbar MJ. The effect of total knee arthroplasty on knee joint kinematics and kinetics during gait. J Arthroplasty. 2011;26:309–318.PubMedCrossRef Hatfield GL, Hubley-Kozey CL, Astephen Wilson JL, Dunbar MJ. The effect of total knee arthroplasty on knee joint kinematics and kinetics during gait. J Arthroplasty. 2011;26:309–318.PubMedCrossRef
11.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989;248:13–14.PubMed Insall JN, Dorr LD, Scott RD, Scott WN. Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res. 1989;248:13–14.PubMed
12.
Zurück zum Zitat Johnson F, Leitl S, Waugh W. The distribution of load across the knee: a comparison of static and dynamic measurements. J Bone Joint Surg Br. 1980;62:346–349.PubMed Johnson F, Leitl S, Waugh W. The distribution of load across the knee: a comparison of static and dynamic measurements. J Bone Joint Surg Br. 1980;62:346–349.PubMed
13.
Zurück zum Zitat Kellgren JH, Lawrence JS. Radiological assessment of osteo-arthrosis. Ann Rheum Dis. 1957;16:494–502PubMedCrossRef Kellgren JH, Lawrence JS. Radiological assessment of osteo-arthrosis. Ann Rheum Dis. 1957;16:494–502PubMedCrossRef
14.
Zurück zum Zitat Mandeville D, Osternig LR, Lantz BA, Mohler CG, Chou LS. The effect of total knee replacement on the knee varus angle and moment during walking and stair ascent. Clin Biomech (Bristol, Avon). 2008;23:1053–1058.CrossRef Mandeville D, Osternig LR, Lantz BA, Mohler CG, Chou LS. The effect of total knee replacement on the knee varus angle and moment during walking and stair ascent. Clin Biomech (Bristol, Avon). 2008;23:1053–1058.CrossRef
15.
Zurück zum Zitat Miyazaki T, Wada M, Kawahara H, Sato M, Baba H, Shimada S. Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritis. Ann Rheum Dis. 2002;61:617–622.PubMedCrossRef Miyazaki T, Wada M, Kawahara H, Sato M, Baba H, Shimada S. Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritis. Ann Rheum Dis. 2002;61:617–622.PubMedCrossRef
16.
Zurück zum Zitat Prodromos CC, Andriacchi TP, Galante JO. A relationship between gait and clinical changes following high tibial osteotomy. J Bone Joint Surg Am. 1985;67:1188–1194.PubMed Prodromos CC, Andriacchi TP, Galante JO. A relationship between gait and clinical changes following high tibial osteotomy. J Bone Joint Surg Am. 1985;67:1188–1194.PubMed
17.
Zurück zum Zitat Robbins SM, Maly MR. The effect of gait speed on the knee adduction moment depends on waveform summary measures. Gait Posture. 2009;30:543–546.PubMedCrossRef Robbins SM, Maly MR. The effect of gait speed on the knee adduction moment depends on waveform summary measures. Gait Posture. 2009;30:543–546.PubMedCrossRef
18.
Zurück zum Zitat Schipplein OD, Andriacchi TP. Interaction between active and passive knee stabilizers during level walking. J Orthop Res. 1991;9:113–119.PubMedCrossRef Schipplein OD, Andriacchi TP. Interaction between active and passive knee stabilizers during level walking. J Orthop Res. 1991;9:113–119.PubMedCrossRef
19.
Zurück zum Zitat Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD. The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA. 2001;286:188–195.PubMedCrossRef Sharma L, Song J, Felson DT, Cahue S, Shamiyeh E, Dunlop DD. The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA. 2001;286:188–195.PubMedCrossRef
20.
Zurück zum Zitat Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR. Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg. 2004;17:203–210.PubMed Specogna AV, Birmingham TB, DaSilva JJ, Milner JS, Kerr J, Hunt MA, Jones IC, Jenkyn TR, Fowler PJ, Giffin JR. Reliability of lower limb frontal plane alignment measurements using plain radiographs and digitized images. J Knee Surg. 2004;17:203–210.PubMed
21.
Zurück zum Zitat Wada M, Maezawa Y, Baba H, Shimada S, Sasaki S, Nose Y. Relationships among bone mineral densities, static alignment and dynamic load in patients with medial compartment knee osteoarthritis. Rheumatology (Oxford). 2001;40:499–505.CrossRef Wada M, Maezawa Y, Baba H, Shimada S, Sasaki S, Nose Y. Relationships among bone mineral densities, static alignment and dynamic load in patients with medial compartment knee osteoarthritis. Rheumatology (Oxford). 2001;40:499–505.CrossRef
22.
Zurück zum Zitat Wang JW, Kuo KN, Andriacchi TP, Galante JO. The influence of walking mechanics and time on the results of proximal tibial osteotomy. J Bone Joint Surg Am. 1990;72:905–909.PubMed Wang JW, Kuo KN, Andriacchi TP, Galante JO. The influence of walking mechanics and time on the results of proximal tibial osteotomy. J Bone Joint Surg Am. 1990;72:905–909.PubMed
23.
Zurück zum Zitat Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;299:31–43.PubMed Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res. 1994;299:31–43.PubMed
Metadaten
Titel
Does Total Knee Arthroplasty Change Frontal Plane Knee Biomechanics During Gait?
verfasst von
Karl F. Orishimo, MS
Ian J. Kremenic, MEng
Ajit J. Deshmukh, MD
Stephen J. Nicholas, MD
Jose A. Rodriguez, MD
Publikationsdatum
01.04.2012
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 4/2012
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-2196-0

Weitere Artikel der Ausgabe 4/2012

Clinical Orthopaedics and Related Research® 4/2012 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.