Abstract

Background

Patient-specific cutting blocks have been touted as a more efficient and reliable means of achieving neutral mechanical alignment during TKA with the proposed downstream effect of improved clinical outcomes. However, it is not clear to what degree published studies support these assumptions.

Questions/purposes

We asked: (1) Do patient-specific cutting blocks achieve neutral mechanical alignment more reliably during TKA when compared with conventional methods? (2) Does patient-specific instrumentation (PSI) provide financial benefit through improved surgical efficiency? (3) Does the use of patient-specific cutting blocks translate to improved clinical results after TKA when compared with conventional instrumentation?

Methods

We performed a systematic review in accordance with Cochrane guidelines of controlled studies (prospective and retrospective) in MEDLINE® and EMBASE® with respect to patient-specific cutting blocks and their effect on alignment, cost, operative time, clinical outcome scores, complications, and survivorship. Sixteen studies (Level I–III on the levels of evidence rubric) were identified and used in addressing the first question, 13 (Level I–III) for the second question, and two (Level III) for the third question. Qualitative assessment of the selected Level I studies was performed using the modified Jadad score; Level II and III studies were rated based on the Newcastle-Ottawa scoring system.

Results

The majority of studies did not show an improvement in overall limb alignment when PSI was compared with standard instrumentation. Mixed results were seen across studies with regard to the prevalence of alignment outliers when PSI was compared with conventional cutting blocks with some studies demonstrating no difference, some showing an improvement with PSI, and a single study showing worse results with PSI. The studies demonstrated mixed results regarding the influence of PSI on operative times. Decreased operative times were not uniformly observed, and when noted, they were found to be of minimal clinical or financial significance. PSI did reliably reduce the number of instrument trays required for processing perioperatively. The accuracy of the preoperative plan, generated by the PSI manufacturers, was found lacking, often leading to multiple intraoperative changes, thereby disrupting the flow of the operation and negatively impacting efficiency. Limited data exist with regard to the effect of PSI on postoperative function, improvement in pain, and patient satisfaction. Neither of the two studies we identified provided strong evidence to support an advantage favoring the use of PSI. No identified studies addressed survivorship of components placed with PSI compared with those placed with standard instrumentation.

Conclusions

PSI for TKA has not reliably demonstrated improvement of postoperative limb or component alignment when compared with standard instrumentation. Although decisive evidence exists to support that PSI requires fewer surgical trays, PSI has not clearly been shown to improve overall surgical efficiency or the cost-effectiveness of TKA. Mid- and long-term data regarding PSI’s effect on functional outcomes and component survivorship do not exist and short-term data are scarce. Limited available literature does not clearly support any improvement of postoperative pain, activity, function, or ROM when PSI is compared with traditional instrumentation.
Literatur
1.
Zurück zum Zitat Barke S, Musanhu E, Busch C, Stafford G, Field R. Patient-matched total knee arthroplasty: does it offer any clinical advantages? Acta Orthop Belg. 2013;79:307–311.PubMed Barke S, Musanhu E, Busch C, Stafford G, Field R. Patient-matched total knee arthroplasty: does it offer any clinical advantages? Acta Orthop Belg. 2013;79:307–311.PubMed
2.
Zurück zum Zitat Barrack RL, Ruh EL, Williams BM, Ford AD, Foreman K, Nunley RM. Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br. 2012;94(Suppl A):95–99.PubMedCrossRef Barrack RL, Ruh EL, Williams BM, Ford AD, Foreman K, Nunley RM. Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br. 2012;94(Suppl A):95–99.PubMedCrossRef
3.
Zurück zum Zitat Barrett W, Hoeffel D, Dalury D, Mason JB, Murphy J, Himden S. In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty. J Arthroplasty. 2014;29:343–347.PubMedCrossRef Barrett W, Hoeffel D, Dalury D, Mason JB, Murphy J, Himden S. In-vivo alignment comparing patient specific instrumentation with both conventional and computer assisted surgery (CAS) instrumentation in total knee arthroplasty. J Arthroplasty. 2014;29:343–347.PubMedCrossRef
4.
Zurück zum Zitat Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26–34.PubMedCrossRef Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26–34.PubMedCrossRef
5.
Zurück zum Zitat Boonen B, Schotanus MG, Kort NP. Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthop. 2012;83:387–393.PubMedCentralPubMedCrossRef Boonen B, Schotanus MG, Kort NP. Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthop. 2012;83:387–393.PubMedCentralPubMedCrossRef
6.
Zurück zum Zitat Burnett RS, Barrack RL. Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res. 2013;471:264–276.PubMedCentralPubMedCrossRef Burnett RS, Barrack RL. Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res. 2013;471:264–276.PubMedCentralPubMedCrossRef
7.
Zurück zum Zitat Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C. A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J. 2013;95:354–359.PubMedCrossRef Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C. A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J. 2013;95:354–359.PubMedCrossRef
8.
Zurück zum Zitat Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN, Chin PL. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2014;22:630–635.PubMedCrossRef Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN, Chin PL. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2014;22:630–635.PubMedCrossRef
9.
Zurück zum Zitat Confalonieri N, Manzotti A, Pullen C, Ragone V. Computer-assisted technique versus intramedullary and extramedullary alignment systems in total knee replacement: a radiological comparison. Acta Orthop Belg. 2005;71:703–709.PubMed Confalonieri N, Manzotti A, Pullen C, Ragone V. Computer-assisted technique versus intramedullary and extramedullary alignment systems in total knee replacement: a radiological comparison. Acta Orthop Belg. 2005;71:703–709.PubMed
10.
Zurück zum Zitat Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A. Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc. 2013;21:2194–2199.PubMedCrossRef Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A. Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc. 2013;21:2194–2199.PubMedCrossRef
11.
Zurück zum Zitat Daniilidis K, Tibesku CO. A comparison of conventional and patient-specific instruments in total knee arthroplasty. Int Orthop. 2014;38:503–508.PubMedCrossRef Daniilidis K, Tibesku CO. A comparison of conventional and patient-specific instruments in total knee arthroplasty. Int Orthop. 2014;38:503–508.PubMedCrossRef
12.
Zurück zum Zitat Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24(Suppl):39–43.PubMedCrossRef Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty. 2009;24(Suppl):39–43.PubMedCrossRef
13.
Zurück zum Zitat Hamilton WG, Parks NL, Saxena A. Patient-specific instrumentation does not shorten surgical time: a prospective, randomized trial. J Arthroplasty. 2013;28(Suppl):96–100.PubMedCrossRef Hamilton WG, Parks NL, Saxena A. Patient-specific instrumentation does not shorten surgical time: a prospective, randomized trial. J Arthroplasty. 2013;28(Suppl):96–100.PubMedCrossRef
14.
Zurück zum Zitat Heyse TJ, Tibesku CO. Improved femoral component rotation in TKA using patient-specific instrumentation. Knee. 2014;21:268–271.PubMedCrossRef Heyse TJ, Tibesku CO. Improved femoral component rotation in TKA using patient-specific instrumentation. Knee. 2014;21:268–271.PubMedCrossRef
15.
Zurück zum Zitat Issa K, Rifai A, McGrath MS, Callaghan JJ, Wright C, Malkani AL, Mont MA, McInerney VK. Reliability of templating with patient-specific instrumentation in total knee arthroplasty. J Knee Surg. 2013;26:429–433.PubMedCrossRef Issa K, Rifai A, McGrath MS, Callaghan JJ, Wright C, Malkani AL, Mont MA, McInerney VK. Reliability of templating with patient-specific instrumentation in total knee arthroplasty. J Knee Surg. 2013;26:429–433.PubMedCrossRef
16.
Zurück zum Zitat Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ. Assessing the quality of reports of randomized clinical trials: is blinding necessary. Control Clin Trials. 1996;17:1–12.PubMedCrossRef Jadad AR, Moore RA, Carroll D, Jenkinson C, Reynolds DJ, Gavaghan DJ, McQuay HJ. Assessing the quality of reports of randomized clinical trials: is blinding necessary. Control Clin Trials. 1996;17:1–12.PubMedCrossRef
17.
Zurück zum Zitat Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty. 2007;22:1097–1106.PubMedCrossRef Mason JB, Fehring TK, Estok R, Banel D, Fahrbach K. Meta-analysis of alignment outcomes in computer-assisted total knee arthroplasty surgery. J Arthroplasty. 2007;22:1097–1106.PubMedCrossRef
18.
Zurück zum Zitat Meding JB, Berend ME, Ritter MA, Galley MR, Malinzak RA. Intramedullary vs extramedullary femoral alignment guides: a 15-year follow-up of survivorship. J Arthroplasty. 2011;26:591–595.PubMedCrossRef Meding JB, Berend ME, Ritter MA, Galley MR, Malinzak RA. Intramedullary vs extramedullary femoral alignment guides: a 15-year follow-up of survivorship. J Arthroplasty. 2011;26:591–595.PubMedCrossRef
19.
Zurück zum Zitat Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res. 2012;470:99–107.PubMedCentralPubMedCrossRef Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr. Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res. 2012;470:99–107.PubMedCentralPubMedCrossRef
20.
Zurück zum Zitat Noble JW Jr, Moore CA, Liu N. The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty. 2012;27:153–155.PubMedCrossRef Noble JW Jr, Moore CA, Liu N. The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty. 2012;27:153–155.PubMedCrossRef
21.
Zurück zum Zitat Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL. Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res. 2012;470:889–894.PubMedCentralPubMedCrossRef Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL. Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res. 2012;470:889–894.PubMedCentralPubMedCrossRef
22.
Zurück zum Zitat Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL. Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res. 2012;470:895–902.PubMedCentralPubMedCrossRef Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL. Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res. 2012;470:895–902.PubMedCentralPubMedCrossRef
24.
Zurück zum Zitat Pang CH, Chan WL, Yen CH, Cheng SC, Woo SB, Choi ST, Hui WK, Mak KH. Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study. J Orthop Surg (Hong Kong). 2009;17:170–173. Pang CH, Chan WL, Yen CH, Cheng SC, Woo SB, Choi ST, Hui WK, Mak KH. Comparison of total knee arthroplasty using computer-assisted navigation versus conventional guiding systems: a prospective study. J Orthop Surg (Hong Kong). 2009;17:170–173.
25.
Zurück zum Zitat Parratte S, Blanc G, Boussemart T, Ollivier M, Le Corroller T, Argenson JN. Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation. Knee Surg Sports Traumatol Arthrosc. 2013;21:2213–2219.PubMedCrossRef Parratte S, Blanc G, Boussemart T, Ollivier M, Le Corroller T, Argenson JN. Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation. Knee Surg Sports Traumatol Arthrosc. 2013;21:2213–2219.PubMedCrossRef
26.
Zurück zum Zitat Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143–2149.PubMedCrossRef Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92:2143–2149.PubMedCrossRef
27.
Zurück zum Zitat Pietsch M, Djahani O, Hochegger M, Plattner F, Hofmann S. Patient-specific total knee arthroplasty: the importance of planning by the surgeon. Knee Surg Sports Traumatol Arthrosc. 2013;21:2220–2226.PubMedCrossRef Pietsch M, Djahani O, Hochegger M, Plattner F, Hofmann S. Patient-specific total knee arthroplasty: the importance of planning by the surgeon. Knee Surg Sports Traumatol Arthrosc. 2013;21:2220–2226.PubMedCrossRef
28.
Zurück zum Zitat Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93:1588–1596.PubMedCrossRef Ritter MA, Davis KE, Meding JB, Pierson JL, Berend ME, Malinzak RA. The effect of alignment and BMI on failure of total knee replacement. J Bone Joint Surg Am. 2011;93:1588–1596.PubMedCrossRef
29.
Zurück zum Zitat Scholes C, Sahni V, Lustig S, Parker DA, Coolican MR. Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation. Knee Surg Sports Traumatol Arthrosc. 2014;22:660–665.PubMedCrossRef Scholes C, Sahni V, Lustig S, Parker DA, Coolican MR. Patient-specific instrumentation for total knee arthroplasty does not match the pre-operative plan as assessed by intra-operative computer-assisted navigation. Knee Surg Sports Traumatol Arthrosc. 2014;22:660–665.PubMedCrossRef
30.
Zurück zum Zitat Silva A, Sampaio R, Pinto E. Patient-specific instrumentation improves tibial component rotation in TKA. Knee Surg Sports Traumatol Arthrosc. 2014;22:636–642.PubMedCrossRef Silva A, Sampaio R, Pinto E. Patient-specific instrumentation improves tibial component rotation in TKA. Knee Surg Sports Traumatol Arthrosc. 2014;22:636–642.PubMedCrossRef
31.
Zurück zum Zitat Stronach BM, Pelt CE, Erickson J, Peters CL. Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res. 2013;471:169–174.PubMedCentralPubMedCrossRef Stronach BM, Pelt CE, Erickson J, Peters CL. Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res. 2013;471:169–174.PubMedCentralPubMedCrossRef
32.
Zurück zum Zitat Vundelinckx BJ, Bruckers L, De Mulder K, De Schepper J, Van Esbroeck G. Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty. 2013;28:964–970.PubMedCrossRef Vundelinckx BJ, Bruckers L, De Mulder K, De Schepper J, Van Esbroeck G. Functional and radiographic short-term outcome evaluation of the Visionaire system, a patient-matched instrumentation system for total knee arthroplasty. J Arthroplasty. 2013;28:964–970.PubMedCrossRef
33.
Zurück zum Zitat Yaffe M, Luo M, Goyal N, Chan P, Patel A, Cayo M, Stulberg SD. Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study. Int J Comput Assist Radiol Surg. 2013 Dec 13 [Epub ahead of print]. Yaffe M, Luo M, Goyal N, Chan P, Patel A, Cayo M, Stulberg SD. Clinical, functional, and radiographic outcomes following total knee arthroplasty with patient-specific instrumentation, computer-assisted surgery, and manual instrumentation: a short-term follow-up study. Int J Comput Assist Radiol Surg. 2013 Dec 13 [Epub ahead of print].
Metadaten
Titel
Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved
verfasst von
Adam Sassoon, MD
Denis Nam, MD
Ryan Nunley, MD
Robert Barrack, MD
Publikationsdatum
01.01.2015
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 1/2015
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-014-3804-6

Weitere Artikel der Ausgabe 1/2015

Clinical Orthopaedics and Related Research® 1/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.