Adequacy and Diagnostic Accuracy of Aspiration vs. Capillary Fine Needle Thyroid Biopsies

verfasst von: Gisah Amaral de Carvalho, Gilberto Paz-Filho, Teresa C. Cavalcanti, Hans Graf

Erschienen in: Endocrine Pathology | Ausgabe 4/2009

Einloggen, um Zugang zu erhalten

Abstract

Thyroid nodules can be biopsied by fine needle aspiration (FNA) or fine needle capillary (FNC) biopsies. However, there is controversy on whether one technique is superior to another. In a randomized cytopathologist-blinded cross-sectional study, 260 patients (238 females, age 43.2 ± 12.6) with nodular (82.7%) and diffuse goiter (17.3%) underwent 520 FNAs and 520 FNCs (not guided by ultrasound). Smears were scored for sample adequacy, and diagnosed as malignant, benign, suspicious, or nondiagnostic. Diagnostic accuracy was calculated based on the histological findings of 58 patients submitted to surgery. Intra-technique diagnostic accuracy and sample adequacy was seen in all samples. FNA and FNC provided similar cytological diagnosis, respectively (benign: 75.8% vs. 74.2%, p = 0.600; malignant: 3.8% vs. 3.8%, p = 0.871; suspicious: 10.4% vs. 10.8%, p = 0.913; and nondiagnostic: 10.0% vs. 11.2%, p = 0.598). Adequacy scores were similar by FNA (7.94 ± 2.84) and FNC (7.96 ± 2.81, p = 0.909). The same proportion of adequate or superior samples was seen in both techniques (91.6%). Sensitivity was equal to 85.7% for FNA and 100% for FNC. Similarly, specificity was 100% for both techniques. FNA and FNC provide the similar sample adequacy and diagnostic accuracy. The choice of technique should be based on the operator’s personal preferences and experience.
Literatur
1.
Zurück zum Zitat Soderstrom N. Puncture of goiters for aspiration biopsy. Acta Med Scand. 144:237–44, 1952.PubMed Soderstrom N. Puncture of goiters for aspiration biopsy. Acta Med Scand. 144:237–44, 1952.PubMed
2.
Zurück zum Zitat Santos JE, Leiman G. Nonaspiration fine needle cytology. Application of a new technique to nodular thyroid disease. Acta Cytol. 32:353–6, 1988.PubMed Santos JE, Leiman G. Nonaspiration fine needle cytology. Application of a new technique to nodular thyroid disease. Acta Cytol. 32:353–6, 1988.PubMed
3.
Zurück zum Zitat Rajasekhar A, Sundaram C, Chowdhary T, Charanpal M, Ratnakar KS. Diagnostic utility of fine-needle sampling without aspiration: a prospective study. Diagn Cytopathol. 7:473–6, 1991.CrossRefPubMed Rajasekhar A, Sundaram C, Chowdhary T, Charanpal M, Ratnakar KS. Diagnostic utility of fine-needle sampling without aspiration: a prospective study. Diagn Cytopathol. 7:473–6, 1991.CrossRefPubMed
4.
Zurück zum Zitat Zajdela A, Zillhardt P, Voillemot N. Cytological diagnosis by fine needle sampling without aspiration. Cancer. 59:1201–5, 1987.CrossRefPubMed Zajdela A, Zillhardt P, Voillemot N. Cytological diagnosis by fine needle sampling without aspiration. Cancer. 59:1201–5, 1987.CrossRefPubMed
5.
Zurück zum Zitat Mair S, Dunbar F, Becker PJ, Du Plessis W. Fine needle cytology—is aspiration suction necessary? A study of 100 masses in various sites. Acta Cytol. 33:809–13, 1989.PubMed Mair S, Dunbar F, Becker PJ, Du Plessis W. Fine needle cytology—is aspiration suction necessary? A study of 100 masses in various sites. Acta Cytol. 33:809–13, 1989.PubMed
6.
Zurück zum Zitat Haddadi-Nezhad S, Larijani B, Tavangar SM, Nouraei SM. Comparison of fine-needle-nonaspiration with fine-needle-aspiration technique in the cytologic studies of thyroid nodules. Endocr Pathol. 14:369–73, 2003.CrossRefPubMed Haddadi-Nezhad S, Larijani B, Tavangar SM, Nouraei SM. Comparison of fine-needle-nonaspiration with fine-needle-aspiration technique in the cytologic studies of thyroid nodules. Endocr Pathol. 14:369–73, 2003.CrossRefPubMed
7.
Zurück zum Zitat Degirmenci B, Haktanir A, Albayrak R, et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol. 62:798–803, 2007.CrossRefPubMed Degirmenci B, Haktanir A, Albayrak R, et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol. 62:798–803, 2007.CrossRefPubMed
8.
Zurück zum Zitat Kamal MM, Arjune DG, Kulkarni HR. Comparative study of fine needle aspiration and fine needle capillary sampling of thyroid lesions. Acta Cytol. 46:30–4, 2002.PubMed Kamal MM, Arjune DG, Kulkarni HR. Comparative study of fine needle aspiration and fine needle capillary sampling of thyroid lesions. Acta Cytol. 46:30–4, 2002.PubMed
9.
Zurück zum Zitat Schoedel KE, Tublin ME, Pealer K, Ohori NP. Ultrasound-guided biopsy of the thyroid: a comparison of technique with respect to diagnostic accuracy. Diagn Cytopathol. 36:787–9, 2008.CrossRefPubMed Schoedel KE, Tublin ME, Pealer K, Ohori NP. Ultrasound-guided biopsy of the thyroid: a comparison of technique with respect to diagnostic accuracy. Diagn Cytopathol. 36:787–9, 2008.CrossRefPubMed
10.
Zurück zum Zitat Tublin ME, Martin JA, Rollin LJ, Pealer K, Kurs-Lasky M, Ohori NP. Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter? J Ultrasound Med. 26:1697–701, 2007.PubMed Tublin ME, Martin JA, Rollin LJ, Pealer K, Kurs-Lasky M, Ohori NP. Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter? J Ultrasound Med. 26:1697–701, 2007.PubMed
11.
Zurück zum Zitat Kate MS, Kamal MM, Bobhate SK, Kher AV. Evaluation of fine needle capillary sampling in superficial and deep-seated lesions. An analysis of 670 cases. Acta Cytol. 42:679–84, 1998.PubMed Kate MS, Kamal MM, Bobhate SK, Kher AV. Evaluation of fine needle capillary sampling in superficial and deep-seated lesions. An analysis of 670 cases. Acta Cytol. 42:679–84, 1998.PubMed
12.
Zurück zum Zitat Lundgren CI, Zedenius J, Skoog L. Fine-needle aspiration biopsy of benign thyroid nodules: an evidence-based review. World J Surg. 32:1247–52, 2008.CrossRefPubMed Lundgren CI, Zedenius J, Skoog L. Fine-needle aspiration biopsy of benign thyroid nodules: an evidence-based review. World J Surg. 32:1247–52, 2008.CrossRefPubMed
13.
Zurück zum Zitat Leung AM, Farwell AP. Unsatisfactory consequences from fine-needle aspiration biopsy of thyroid nodules. Thyroid. 18:491–2, 2008.CrossRefPubMed Leung AM, Farwell AP. Unsatisfactory consequences from fine-needle aspiration biopsy of thyroid nodules. Thyroid. 18:491–2, 2008.CrossRefPubMed
Metadaten
Titel
Adequacy and Diagnostic Accuracy of Aspiration vs. Capillary Fine Needle Thyroid Biopsies
verfasst von
Gisah Amaral de Carvalho
Gilberto Paz-Filho
Teresa C. Cavalcanti
Hans Graf
Publikationsdatum
01.12.2009
Verlag
Humana Press Inc
Erschienen in
Endocrine Pathology / Ausgabe 4/2009
Print ISSN: 1046-3976
Elektronische ISSN: 1559-0097
DOI
https://doi.org/10.1007/s12022-009-9092-0

Weitere Artikel der Ausgabe 4/2009

Endocrine Pathology 4/2009 Zur Ausgabe

Neu im Fachgebiet Pathologie