Skip to main content
Erschienen in: Neurocritical Care 1/2011

01.08.2011 | Original Article

A Clinical Description of Extubation Failure in Patients with Primary Brain Injury

verfasst von: Navaz Karanjia, Diana Nordquist, Robert Stevens, Paul Nyquist

Erschienen in: Neurocritical Care | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

Background

Patients with acute brain injury but normal lung function are often intubated for airway protection, but extubation often fails. Currently, no clinical data exist that describe the events leading to extubation failure in this population. We examined the extubation failure rate, reintubation rate, and clinical characteristics of patients whose reason for intubation was a primary neurological injury. We then identified the clinical characteristics of those patients with primary brain injury who were reintubated.

Methods

We conducted a retrospective review of patients admitted to the neurocritical care unit of a tertiary care hospital from January 2002 to March 2007.

Results

Of 1,265 patients who were intubated because of primary neurological injury of brain, spinal cord, or peripheral nerve, 25 (2%) died before extubation and 767 (61%) were successfully extubated. Tracheostomies were placed in 181 (14%) patients, of which, 77 (6.1%) were completed before a trial of extubation and 104 (8.2%) after extubation failure. A total of 129 (10%) patients were reintubated; 77 (6.1%) were reintubated within 72 h, meeting the definition of extubation failure. The other 52 (4.1%) were intubated after 72 h usually in the setting of pneumonia or decreased mental status. Ninety-nine of the patients reintubated had primary brain injury and resulting encephalopathy. All were successfully reintubated. Most patients intubated as a result of a primary brain injury (981) were successfully extubated. The most common clinical scenario leading to reintubation in these encephalopathic patients was respiratory distress associated with altered mental status [59 patients (59%)]. These patients usually had atelectasis and decreased minute ventilation, independent of fever, pneumonia, aspiration, and increased work of breathing [39 patients (39%)].

Conclusion

The extubation failure rate in our neurocritical care unit is low. In patients with encephalopathy and primary brain injury who were reintubated, respiratory distress caused by altered mental status was the most common cause of reintubation. These patients demonstrated signs disrupted ventilation usually with periods of prolonged hypoventilation. Increased work of breathing from lung injury due to pneumonia or aspiration was not the most common cause of reintubation in this population.
Literatur
1.
Zurück zum Zitat de Lassence A, Alberti C, Azoulay E, et al. Impact of unplanned extubation and reintubation after weaning on nosocomial pneumonia risk in the intensive care unit: a prospective multicenter study. Anesthesiology. 2002;97(1):148–56.PubMedCrossRef de Lassence A, Alberti C, Azoulay E, et al. Impact of unplanned extubation and reintubation after weaning on nosocomial pneumonia risk in the intensive care unit: a prospective multicenter study. Anesthesiology. 2002;97(1):148–56.PubMedCrossRef
2.
Zurück zum Zitat Gowardman JR, Huntington D, Whiting J. The effect of extubation failure on outcome in a multidisciplinary Australian intensive care unit. Crit Care Resusc. 2006;8(4):328–33.PubMed Gowardman JR, Huntington D, Whiting J. The effect of extubation failure on outcome in a multidisciplinary Australian intensive care unit. Crit Care Resusc. 2006;8(4):328–33.PubMed
3.
Zurück zum Zitat Dries DJ, McGonigal MD, Malian MS, et al. Protocol-driven ventilator weaning reduces use of mechanical ventilation, rate of early reintubation, and ventilator-associated pneumonia. J Trauma. 2004;56(5):943–51 (discussion 951–942).PubMedCrossRef Dries DJ, McGonigal MD, Malian MS, et al. Protocol-driven ventilator weaning reduces use of mechanical ventilation, rate of early reintubation, and ventilator-associated pneumonia. J Trauma. 2004;56(5):943–51 (discussion 951–942).PubMedCrossRef
4.
Zurück zum Zitat Epstein SK, Ciubotaru RL, Wong JB. Effect of failed extubation on the outcome of mechanical ventilation. Chest. 1997;112(1):186–92.PubMedCrossRef Epstein SK, Ciubotaru RL, Wong JB. Effect of failed extubation on the outcome of mechanical ventilation. Chest. 1997;112(1):186–92.PubMedCrossRef
5.
Zurück zum Zitat Robertson TE, Sona C, Schallom L, et al. Improved extubation rates and earlier liberation from mechanical ventilation with implementation of a daily spontaneous-breathing trial protocol. J Am Coll Surg. 2008;206(3):489–95.PubMedCrossRef Robertson TE, Sona C, Schallom L, et al. Improved extubation rates and earlier liberation from mechanical ventilation with implementation of a daily spontaneous-breathing trial protocol. J Am Coll Surg. 2008;206(3):489–95.PubMedCrossRef
6.
Zurück zum Zitat Boles JM, Bion J, Connors A, et al. Weaning from mechanical ventilation. Eur Respir J. 2007;29(5):1033–56.PubMedCrossRef Boles JM, Bion J, Connors A, et al. Weaning from mechanical ventilation. Eur Respir J. 2007;29(5):1033–56.PubMedCrossRef
7.
Zurück zum Zitat Manthous CA, Schmidt GA, Hall JB. Liberation from mechanical ventilation: a decade of progress. Chest. 1998;114(3):886–901.PubMedCrossRef Manthous CA, Schmidt GA, Hall JB. Liberation from mechanical ventilation: a decade of progress. Chest. 1998;114(3):886–901.PubMedCrossRef
8.
Zurück zum Zitat Capdevila XJ, Perrigault PF, Perey PJ, et al. Occlusion pressure and its ratio to maximum inspiratory pressure are useful predictors for successful extubation following T-piece weaning trial. Chest. 1995;108(2):482–9.PubMedCrossRef Capdevila XJ, Perrigault PF, Perey PJ, et al. Occlusion pressure and its ratio to maximum inspiratory pressure are useful predictors for successful extubation following T-piece weaning trial. Chest. 1995;108(2):482–9.PubMedCrossRef
9.
Zurück zum Zitat Ferrer M, Valencia M, Nicolas JM, et al. Early noninvasive ventilation averts extubation failure in patients at risk: a randomized trial. Am J Respir Crit Care Med. 2006;173(2):164–70.PubMedCrossRef Ferrer M, Valencia M, Nicolas JM, et al. Early noninvasive ventilation averts extubation failure in patients at risk: a randomized trial. Am J Respir Crit Care Med. 2006;173(2):164–70.PubMedCrossRef
10.
Zurück zum Zitat Lee KH, Hui KP, Chan TB, et al. Rapid shallow breathing (frequency-tidal volume ratio) did not predict extubation outcome. Chest. 1994;105(2):540–3.PubMedCrossRef Lee KH, Hui KP, Chan TB, et al. Rapid shallow breathing (frequency-tidal volume ratio) did not predict extubation outcome. Chest. 1994;105(2):540–3.PubMedCrossRef
11.
Zurück zum Zitat Mokhlesi B, Tulaimat A, Gluckman TJ, et al. Predicting extubation failure after successful completion of a spontaneous breathing trial. Respir Care. 2007;52(12):1710–7.PubMed Mokhlesi B, Tulaimat A, Gluckman TJ, et al. Predicting extubation failure after successful completion of a spontaneous breathing trial. Respir Care. 2007;52(12):1710–7.PubMed
12.
Zurück zum Zitat Frutos-Vivar F, Ferguson ND, Esteban A, et al. Risk factors for extubation failure in patients following a successful spontaneous breathing trial. Chest. 2006;130(6):1664–71.PubMedCrossRef Frutos-Vivar F, Ferguson ND, Esteban A, et al. Risk factors for extubation failure in patients following a successful spontaneous breathing trial. Chest. 2006;130(6):1664–71.PubMedCrossRef
13.
Zurück zum Zitat Namen AM, Ely EW, Tatter SB, et al. Predictors of successful extubation in neurosurgical patients. Am J Respir Crit Care Med. 2001;163(3 Pt 1):658–64.PubMed Namen AM, Ely EW, Tatter SB, et al. Predictors of successful extubation in neurosurgical patients. Am J Respir Crit Care Med. 2001;163(3 Pt 1):658–64.PubMed
14.
Zurück zum Zitat Rady MY, Ryan T. Perioperative predictors of extubation failure and the effect on clinical outcome after cardiac surgery. Crit Care Med. 1999;27(2):340–7.PubMedCrossRef Rady MY, Ryan T. Perioperative predictors of extubation failure and the effect on clinical outcome after cardiac surgery. Crit Care Med. 1999;27(2):340–7.PubMedCrossRef
15.
Zurück zum Zitat Esteban A, Anzueto A, Alia I, et al. How is mechanical ventilation employed in the intensive care unit? An international utilization review. Am J Respir Crit Care Med. 2000;161(5):1450–8.PubMed Esteban A, Anzueto A, Alia I, et al. How is mechanical ventilation employed in the intensive care unit? An international utilization review. Am J Respir Crit Care Med. 2000;161(5):1450–8.PubMed
16.
Zurück zum Zitat Salam A, Tilluckdharry L, Amoateng-Adjepong Y, et al. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334–9.PubMedCrossRef Salam A, Tilluckdharry L, Amoateng-Adjepong Y, et al. Neurologic status, cough, secretions and extubation outcomes. Intensive Care Med. 2004;30(7):1334–9.PubMedCrossRef
17.
Zurück zum Zitat Wijdicks EFM, editor. The clinical practice of critical care neurology. 2nd ed. New York: Oxford University Press; 2003. Wijdicks EFM, editor. The clinical practice of critical care neurology. 2nd ed. New York: Oxford University Press; 2003.
18.
Zurück zum Zitat Layon AJ, Gabrielli A, Friedman WA, editors. Textbook of neurointensive care. 1st ed. Philadelphia: Saunders; 2004. Layon AJ, Gabrielli A, Friedman WA, editors. Textbook of neurointensive care. 1st ed. Philadelphia: Saunders; 2004.
19.
Zurück zum Zitat Suarez JI, editor. Critical care neurology and neurosurgery. Totowa: Humana Press; 2004. Suarez JI, editor. Critical care neurology and neurosurgery. Totowa: Humana Press; 2004.
20.
Zurück zum Zitat Coplin WM, Pierson DJ, Cooley KD, et al. Implications of extubation delay in brain-injured patients meeting standard weaning criteria. Am J Respir Crit Care Med. 2000;161(5):1530–6.PubMed Coplin WM, Pierson DJ, Cooley KD, et al. Implications of extubation delay in brain-injured patients meeting standard weaning criteria. Am J Respir Crit Care Med. 2000;161(5):1530–6.PubMed
21.
Zurück zum Zitat Ely EW, Baker AM, Evans GW, et al. The prognostic significance of passing a daily screen of weaning parameters. Intensive Care Med. 1999;25(6):581–7.PubMedCrossRef Ely EW, Baker AM, Evans GW, et al. The prognostic significance of passing a daily screen of weaning parameters. Intensive Care Med. 1999;25(6):581–7.PubMedCrossRef
22.
Zurück zum Zitat Esteban A, Frutos F, Tobin MJ, et al. A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group. N Engl J Med. 1995;332(6):345–50.PubMedCrossRef Esteban A, Frutos F, Tobin MJ, et al. A comparison of four methods of weaning patients from mechanical ventilation. Spanish Lung Failure Collaborative Group. N Engl J Med. 1995;332(6):345–50.PubMedCrossRef
23.
Zurück zum Zitat DeHaven CB Jr, Hurst JM, Branson RD. Evaluation of two different extubation criteria: attributes contributing to success. Crit Care Med. 1986;14(2):92–4.PubMedCrossRef DeHaven CB Jr, Hurst JM, Branson RD. Evaluation of two different extubation criteria: attributes contributing to success. Crit Care Med. 1986;14(2):92–4.PubMedCrossRef
24.
Zurück zum Zitat Manno EM, Rabinstein AA, Wijdicks EF, et al. A prospective trial of elective extubation in brain injured patients meeting extubation criteria for ventilatory support: a feasibility study. Crit Care. 2008;12(6):R138.PubMedCrossRef Manno EM, Rabinstein AA, Wijdicks EF, et al. A prospective trial of elective extubation in brain injured patients meeting extubation criteria for ventilatory support: a feasibility study. Crit Care. 2008;12(6):R138.PubMedCrossRef
25.
Zurück zum Zitat Miller PR, Johnson JC III, Karchmer T, et al. National nosocomial infection surveillance system: from benchmark to bedside in trauma patients. J Trauma. 2006;60(1):98–103.PubMedCrossRef Miller PR, Johnson JC III, Karchmer T, et al. National nosocomial infection surveillance system: from benchmark to bedside in trauma patients. J Trauma. 2006;60(1):98–103.PubMedCrossRef
26.
Zurück zum Zitat Horan TC, Andrus M, Dudeck MA. CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control. 2008;36:309–32.PubMedCrossRef Horan TC, Andrus M, Dudeck MA. CDC/NHSN surveillance definition of health care-associated infection and criteria for specific types of infections in the acute care setting. Am J Infect Control. 2008;36:309–32.PubMedCrossRef
27.
Zurück zum Zitat Seymour CW, Martinez A, Christie JD, et al. The outcome of extubation failure in a community hospital intensive care unit: a cohort study. Crit Care. 2004;8(5):R322–7.PubMedCrossRef Seymour CW, Martinez A, Christie JD, et al. The outcome of extubation failure in a community hospital intensive care unit: a cohort study. Crit Care. 2004;8(5):R322–7.PubMedCrossRef
28.
Zurück zum Zitat Epstein SK, Ciubotaru RL. Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med. 1998;158(2):489–93.PubMed Epstein SK, Ciubotaru RL. Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med. 1998;158(2):489–93.PubMed
29.
Zurück zum Zitat Epstein SK, Nevins ML, Chung J. Effect of unplanned extubation on outcome of mechanical ventilation. Am J Respir Crit Care Med. 2000;161(6):1912–6.PubMed Epstein SK, Nevins ML, Chung J. Effect of unplanned extubation on outcome of mechanical ventilation. Am J Respir Crit Care Med. 2000;161(6):1912–6.PubMed
Metadaten
Titel
A Clinical Description of Extubation Failure in Patients with Primary Brain Injury
verfasst von
Navaz Karanjia
Diana Nordquist
Robert Stevens
Paul Nyquist
Publikationsdatum
01.08.2011
Verlag
Humana Press Inc
Erschienen in
Neurocritical Care / Ausgabe 1/2011
Print ISSN: 1541-6933
Elektronische ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-011-9528-5

Weitere Artikel der Ausgabe 1/2011

Neurocritical Care 1/2011 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.