Purpose

We evaluated the efficacy of 99mTc-sestamibi SPECT/CT for planning minimally invasive parathyroidectomy (MIP), comparing with dual phase 99mTc-sestamibi scintigraphy, 99mTc-sestamibi SPECT and conventional imaging (US and CT).

Methods

Thirty-one patients (M:F = 10:21, range 35–78 years old) who showed high serum parathyroid hormone (intact PTH) level were included. 99mTc-sestamibi scintigraphy was performed 15 and 150 min after injection of 99mTc-sestamibi (555 MBq), and 99mTc-sestamibi SPECT/CT was obtained just after the delayed scan. Comparison study between imaging modalities was done by patient-based and lesion location-based analysis. The location of the lesion was confirmed by the operative finding. An operation was performed in 24 patients. Seven patients had normal 99mTc-sestamibi SPECT/CT, and followed for more than 6 months after SPECT/CT.

Results

Among 24 patients, parathyroid adenoma was detected in 19 patients and the other 5 had parathyroid hyperplasia (total 35 lesions). 99mTc-sestamibi scintigraphy detected abnormal uptake in 15 patients with 24 lesions. Conventional imaging identified abnormal findings in 17 patients with 27 lesions. SPECT detected abnormal findings in 18 patients with 27 lesions. SPECT/CT identified abnormal findings in 24 patients with 35 lesions. SPECT/CT demonstrated 100 % sensitivity in a patient-based analysis. SPECT/CT exhibited significantly better sensitivity than 99mTc-sestamibi scintigraphy, SPECT and conventional imaging (p < 0.05). All lesion location was correctly identified to perform MIP. The final clinical diagnosis of 7 normal SPECT/CT patients was secondary hyperparathyroidism on 6 months follow-up.

Conclusions

We correctly identified the precise location of parathyroid adenomas or hyperplasia by 99mTc-sestamibi SPECT/CT which was helpful to perform MIP.
Literatur
1.
Zurück zum Zitat Mariani G, Gulec SA, Rubello D, Boni G, Puccini M, Pelizzo MR, et al. Preoperative localization and radioguided parathyroid surgery. J Nucl Med. 2003;44:1443–58.PubMed Mariani G, Gulec SA, Rubello D, Boni G, Puccini M, Pelizzo MR, et al. Preoperative localization and radioguided parathyroid surgery. J Nucl Med. 2003;44:1443–58.PubMed
2.
Zurück zum Zitat Rubello D, Gross MD, Mariani G, AL-N A. Scintigraphic techniques in primary hyperparathyroidism: from pre-operative localisation to intra-operative imaging. Eur J Nucl Med Mol Imaging. 2007;34:926–33.PubMedCrossRef Rubello D, Gross MD, Mariani G, AL-N A. Scintigraphic techniques in primary hyperparathyroidism: from pre-operative localisation to intra-operative imaging. Eur J Nucl Med Mol Imaging. 2007;34:926–33.PubMedCrossRef
3.
Zurück zum Zitat Hetrakul N, Civelek AC, Stagg CA, Udelsman R. In vitro accumulation of technetium-99m-sestamibi in human parathyroid mitochondria. Surgery. 2001;130:1011–8.PubMedCrossRef Hetrakul N, Civelek AC, Stagg CA, Udelsman R. In vitro accumulation of technetium-99m-sestamibi in human parathyroid mitochondria. Surgery. 2001;130:1011–8.PubMedCrossRef
4.
Zurück zum Zitat Ruda JM, Hollenbeak CS, Stack BC Jr. A systematic review of the diagnosis and treatment of primary hyperparathyroidism from 1995 to 2003. Otolaryngol Head Neck Surg. 2005;132:359–72.PubMedCrossRef Ruda JM, Hollenbeak CS, Stack BC Jr. A systematic review of the diagnosis and treatment of primary hyperparathyroidism from 1995 to 2003. Otolaryngol Head Neck Surg. 2005;132:359–72.PubMedCrossRef
5.
Zurück zum Zitat Hopkins CR, Reading CC. Thyroid and parathyroid imaging. Semin Ultrasound CT MR. 1995;16:279–95.PubMedCrossRef Hopkins CR, Reading CC. Thyroid and parathyroid imaging. Semin Ultrasound CT MR. 1995;16:279–95.PubMedCrossRef
6.
Zurück zum Zitat Tziakouri C, Eracleous E, Skannavis S, Pierides A, Symeonides P, Gourtsoyiannis N. Value of ultrasonography, CT and MR imaging in the diagnosis of primary hyperparathyroidism. Acta Radiol. 1996;37:720–6.PubMedCrossRef Tziakouri C, Eracleous E, Skannavis S, Pierides A, Symeonides P, Gourtsoyiannis N. Value of ultrasonography, CT and MR imaging in the diagnosis of primary hyperparathyroidism. Acta Radiol. 1996;37:720–6.PubMedCrossRef
7.
Zurück zum Zitat Levy JM, Kandil E, Yau LC, Cuda JD, Sheth SN, Tufano RP. Can ultrasound be used as the primary screening modality for the localization of parathyroid disease prior to surgery for primary hyperparathyroidism? A review of 440 cases. ORL J Otorhinolaryngol Relat Spec. 2011;73:116–20.PubMedCrossRef Levy JM, Kandil E, Yau LC, Cuda JD, Sheth SN, Tufano RP. Can ultrasound be used as the primary screening modality for the localization of parathyroid disease prior to surgery for primary hyperparathyroidism? A review of 440 cases. ORL J Otorhinolaryngol Relat Spec. 2011;73:116–20.PubMedCrossRef
8.
Zurück zum Zitat Lloyd MN, Lees WR, Milroy EJ. Pre-operative localisation in primary hyperparathyroidism. Clin Radiol. 1990;41:239–43.PubMedCrossRef Lloyd MN, Lees WR, Milroy EJ. Pre-operative localisation in primary hyperparathyroidism. Clin Radiol. 1990;41:239–43.PubMedCrossRef
9.
Zurück zum Zitat Ahuja AT, Wong KT, Ching AS, Fung MK, Lau JY, Yuen EH, et al. Imaging for primary hyperparathyroidism—what beginners should know. Clin Radiol. 2004;59:967–76.PubMedCrossRef Ahuja AT, Wong KT, Ching AS, Fung MK, Lau JY, Yuen EH, et al. Imaging for primary hyperparathyroidism—what beginners should know. Clin Radiol. 2004;59:967–76.PubMedCrossRef
11.
Zurück zum Zitat Sukan A, Reyhan M, Aydin M, Yapar AF, Sert Y, Canpolat T, et al. Preoperative evaluation of hyperparathyroidism: the role of dual-phase parathyroid scintigraphy and ultrasound imaging. Ann Nucl Med. 2008;22:123–31.PubMedCrossRef Sukan A, Reyhan M, Aydin M, Yapar AF, Sert Y, Canpolat T, et al. Preoperative evaluation of hyperparathyroidism: the role of dual-phase parathyroid scintigraphy and ultrasound imaging. Ann Nucl Med. 2008;22:123–31.PubMedCrossRef
12.
Zurück zum Zitat Krausz Y, Bettman L, Guralnik L, Yosilevsky G, Keidar Z, Bar-Shalom R, et al. Technetium-99m-MIBI SPECT/CT in primary hyperparathyroidism. World J Surg. 2006;30:76–83.PubMedCrossRef Krausz Y, Bettman L, Guralnik L, Yosilevsky G, Keidar Z, Bar-Shalom R, et al. Technetium-99m-MIBI SPECT/CT in primary hyperparathyroidism. World J Surg. 2006;30:76–83.PubMedCrossRef
13.
Zurück zum Zitat Neumann DR, Obuchowski NA, Difilippo FP. Preoperative 123I/99mTc-sestamibi subtraction SPECT and SPECT/CT in primary hyperparathyroidism. J Nucl Med. 2008;49:2012–7.PubMedCrossRef Neumann DR, Obuchowski NA, Difilippo FP. Preoperative 123I/99mTc-sestamibi subtraction SPECT and SPECT/CT in primary hyperparathyroidism. J Nucl Med. 2008;49:2012–7.PubMedCrossRef
14.
Zurück zum Zitat Serra A, Bolasco P, Satta L, Nicolosi A, Uccheddu A, Piga M. Role of SPECT/CT in the preoperative assessment of hyperparathyroid patients. Radiol Med. 2006;111:999–1008.PubMedCrossRef Serra A, Bolasco P, Satta L, Nicolosi A, Uccheddu A, Piga M. Role of SPECT/CT in the preoperative assessment of hyperparathyroid patients. Radiol Med. 2006;111:999–1008.PubMedCrossRef
15.
Zurück zum Zitat Kaplan EL, Yashiro T, Salti G. Primary hyperparathyroidism in the, choice of surgical procedures for this disease. Ann Surg. 1990;1992(215):300–17. Kaplan EL, Yashiro T, Salti G. Primary hyperparathyroidism in the, choice of surgical procedures for this disease. Ann Surg. 1990;1992(215):300–17.
16.
Zurück zum Zitat Gupta VK, Yeh KA, Burke GJ, Wei JP. 99m-Technetium sestamibi localized solitary parathyroid adenoma as an indication for limited unilateral surgical exploration. Am J Surg. 1998;176:409–12.PubMedCrossRef Gupta VK, Yeh KA, Burke GJ, Wei JP. 99m-Technetium sestamibi localized solitary parathyroid adenoma as an indication for limited unilateral surgical exploration. Am J Surg. 1998;176:409–12.PubMedCrossRef
17.
Zurück zum Zitat Rubello D, Pelizzo MR, Casara D. Nuclear medicine and minimally invasive surgery of parathyroid adenomas: a fair marriage. Eur J Nucl Med Mol Imaging. 2003;30:189–92.PubMedCrossRef Rubello D, Pelizzo MR, Casara D. Nuclear medicine and minimally invasive surgery of parathyroid adenomas: a fair marriage. Eur J Nucl Med Mol Imaging. 2003;30:189–92.PubMedCrossRef
18.
Zurück zum Zitat Sackett WR, Barraclough B, Reeve TS, Delbridge LW. Worldwide trends in the surgical treatment of primary hyperparathyroidism in the era of minimally invasive parathyroidectomy. Arch Surg. 2002;137:1055–9.PubMedCrossRef Sackett WR, Barraclough B, Reeve TS, Delbridge LW. Worldwide trends in the surgical treatment of primary hyperparathyroidism in the era of minimally invasive parathyroidectomy. Arch Surg. 2002;137:1055–9.PubMedCrossRef
19.
Zurück zum Zitat Carter WB, Carter DL, Cohn HE. Cause and current management of reoperative hyperparathyroidism. Am Surg. 1993;59:120–4.PubMed Carter WB, Carter DL, Cohn HE. Cause and current management of reoperative hyperparathyroidism. Am Surg. 1993;59:120–4.PubMed
20.
Zurück zum Zitat Roach PJ, Schembri GP, Ho Shon IA, Bailey EA, Bailey DL. SPECT/CT imaging using a spiral CT scanner for anatomical localization: impact on diagnostic accuracy and reporter confidence in clinical practice. Nucl Med Commun. 2006;27:977–87.PubMedCrossRef Roach PJ, Schembri GP, Ho Shon IA, Bailey EA, Bailey DL. SPECT/CT imaging using a spiral CT scanner for anatomical localization: impact on diagnostic accuracy and reporter confidence in clinical practice. Nucl Med Commun. 2006;27:977–87.PubMedCrossRef
21.
Zurück zum Zitat Krausz Y, Israel O. Single-photon emission computed tomography/computed tomography in endocrinology. Semin Nucl Med. 2006;36:267–74.PubMedCrossRef Krausz Y, Israel O. Single-photon emission computed tomography/computed tomography in endocrinology. Semin Nucl Med. 2006;36:267–74.PubMedCrossRef
22.
Zurück zum Zitat Buck AK, Nekolla S, Ziegler S, Beer A, Krause BJ, Herrmann K, et al. SPECT/CT. J Nucl Med. 2008;49:1305–19.PubMedCrossRef Buck AK, Nekolla S, Ziegler S, Beer A, Krause BJ, Herrmann K, et al. SPECT/CT. J Nucl Med. 2008;49:1305–19.PubMedCrossRef
23.
Zurück zum Zitat Patel CN, Chowdhury FU, Scarsbrook AF. Hybrid SPECT/CT: the end of “unclear” medicine. Postgrad Med J. 2009;85:606–13.PubMedCrossRef Patel CN, Chowdhury FU, Scarsbrook AF. Hybrid SPECT/CT: the end of “unclear” medicine. Postgrad Med J. 2009;85:606–13.PubMedCrossRef
24.
Zurück zum Zitat Mariani G, Bruselli L, Kuwert T, Kim EE, Flotats A, Israel O, et al. A review on the clinical uses of SPECT/CT. Eur J Nucl Med Mol Imaging. 2010;37:1959–85.PubMedCrossRef Mariani G, Bruselli L, Kuwert T, Kim EE, Flotats A, Israel O, et al. A review on the clinical uses of SPECT/CT. Eur J Nucl Med Mol Imaging. 2010;37:1959–85.PubMedCrossRef
25.
Zurück zum Zitat Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD. SPECT/CT imaging: clinical utility of an emerging technology. Radiographics. 2008;28:1097–113.PubMedCrossRef Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD. SPECT/CT imaging: clinical utility of an emerging technology. Radiographics. 2008;28:1097–113.PubMedCrossRef
26.
Zurück zum Zitat Patel CN, Chowdhury FU, Scarsbrook AF. Clinical utility of hybrid SPECT-CT in endocrine neoplasia. AJR Am J Roentgenol. 2008;190:815–24.PubMedCrossRef Patel CN, Chowdhury FU, Scarsbrook AF. Clinical utility of hybrid SPECT-CT in endocrine neoplasia. AJR Am J Roentgenol. 2008;190:815–24.PubMedCrossRef
27.
Zurück zum Zitat Torregrosa JV, Palomar MR, Pons F, Sabater L, Gilabert R, Llovera J, et al. Has double-phase MIBI scintigraphy usefulness in the diagnosis of hyperparathyroidism? Nephrol Dial Transplant. 1998;13(Suppl 3):37–40.PubMedCrossRef Torregrosa JV, Palomar MR, Pons F, Sabater L, Gilabert R, Llovera J, et al. Has double-phase MIBI scintigraphy usefulness in the diagnosis of hyperparathyroidism? Nephrol Dial Transplant. 1998;13(Suppl 3):37–40.PubMedCrossRef
28.
Zurück zum Zitat Lorberboym M, Minski I, Macadziob S, Nikolov G, Schachter P. Incremental diagnostic value of preoperative 99mTc-MIBI SPECT in patients with a parathyroid adenoma. J Nucl Med. 2003;44:904–8.PubMed Lorberboym M, Minski I, Macadziob S, Nikolov G, Schachter P. Incremental diagnostic value of preoperative 99mTc-MIBI SPECT in patients with a parathyroid adenoma. J Nucl Med. 2003;44:904–8.PubMed
29.
Zurück zum Zitat Rubello D, Massaro A, Cittadin S, Rampin L, Al-Nahhas A, Boni G, et al. Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery. Eur J Nucl Med Mol Imaging. 2006;33:1091–4.PubMedCrossRef Rubello D, Massaro A, Cittadin S, Rampin L, Al-Nahhas A, Boni G, et al. Role of 99mTc-sestamibi SPECT in accurate selection of primary hyperparathyroid patients for minimally invasive radio-guided surgery. Eur J Nucl Med Mol Imaging. 2006;33:1091–4.PubMedCrossRef
30.
Zurück zum Zitat Hindie E, Ugur O, Fuster D, O’Doherty M, Grassetto G, Urena P, et al. 2009 EANM parathyroid guidelines. Eur J Nucl Med Mol Imaging. 2009;36:1201–16.PubMedCrossRef Hindie E, Ugur O, Fuster D, O’Doherty M, Grassetto G, Urena P, et al. 2009 EANM parathyroid guidelines. Eur J Nucl Med Mol Imaging. 2009;36:1201–16.PubMedCrossRef
31.
Zurück zum Zitat Gayed IW, Kim EE, Broussard WF, Evans D, Lee J, Broemeling LD, et al. The value of 99mTc-sestamibi SPECT/CT over conventional SPECT in the evaluation of parathyroid adenomas or hyperplasia. J Nucl Med. 2005;46:248–52.PubMed Gayed IW, Kim EE, Broussard WF, Evans D, Lee J, Broemeling LD, et al. The value of 99mTc-sestamibi SPECT/CT over conventional SPECT in the evaluation of parathyroid adenomas or hyperplasia. J Nucl Med. 2005;46:248–52.PubMed
32.
Zurück zum Zitat Oksuz MO, Dittmann H, Wicke C, Mussig K, Bares R, Pfannenberg C, et al. Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia. Diagn Interv Radiol. 2011;17:297–307.PubMed Oksuz MO, Dittmann H, Wicke C, Mussig K, Bares R, Pfannenberg C, et al. Accuracy of parathyroid imaging: a comparison of planar scintigraphy, SPECT, SPECT-CT, and C-11 methionine PET for the detection of parathyroid adenomas and glandular hyperplasia. Diagn Interv Radiol. 2011;17:297–307.PubMed
33.
Zurück zum Zitat Gulec S, Uğur O. The intellectual and scientific basis of parathyroid surgery. Turk J Med Sci. 2004;34:81–4. Gulec S, Uğur O. The intellectual and scientific basis of parathyroid surgery. Turk J Med Sci. 2004;34:81–4.
34.
Zurück zum Zitat Harris L, Yoo J, Driedger A, Fung K, Franklin J, Gray D, et al. Accuracy of technetium-99m SPECT-CT hybrid images in predicting the precise intraoperative anatomical location of parathyroid adenomas. Head Neck. 2008;30:509–17.PubMedCrossRef Harris L, Yoo J, Driedger A, Fung K, Franklin J, Gray D, et al. Accuracy of technetium-99m SPECT-CT hybrid images in predicting the precise intraoperative anatomical location of parathyroid adenomas. Head Neck. 2008;30:509–17.PubMedCrossRef
35.
Zurück zum Zitat Lavely WC, Goetze S, Friedman KP, Leal JP, Zhang Z, Garret-Mayer E, et al. Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase 99mTc-sestamibi parathyroid scintigraphy. J Nucl Med. 2007;48:1084–9.PubMedCrossRef Lavely WC, Goetze S, Friedman KP, Leal JP, Zhang Z, Garret-Mayer E, et al. Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase 99mTc-sestamibi parathyroid scintigraphy. J Nucl Med. 2007;48:1084–9.PubMedCrossRef
Metadaten
Titel
Efficacy of 99mTc-sestamibi SPECT/CT for minimally invasive parathyroidectomy: comparative study with 99mTc-sestamibi scintigraphy, SPECT, US and CT
verfasst von
Yong-il Kim
Young Ho Jung
Ki Tae Hwang
Ho-Young Lee
Publikationsdatum
01.12.2012
Verlag
Springer Japan
Erschienen in
Annals of Nuclear Medicine / Ausgabe 10/2012
Print ISSN: 0914-7187
Elektronische ISSN: 1864-6433
DOI
https://doi.org/10.1007/s12149-012-0641-0

Weitere Artikel der Ausgabe 10/2012

Annals of Nuclear Medicine 10/2012 Zur Ausgabe