Skip to main content
Erschienen in: Journal of Nuclear Cardiology 4/2011

01.08.2011 | Original Article

Influence of CT-based attenuation correction in assessment of left and right ventricular functions with count-based gated blood-pool SPECT

verfasst von: Louis Sibille, MD, Fayçal Ben Bouallegue, PhD, Aurélie Bourdon, MD, Denis Mariano-Goulart, PhD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 4/2011

Einloggen, um Zugang zu erhalten

Abstract

Objective

Influence of CT-based attenuation correction (CT-AC) in assessment of left and right ventricular functions with count-based gated blood-pool SPECT (GBPS) was evaluated in a mixed population.

Methods

Thirty-two patients (81% male; mean age 56 ± 12) referred for various symptoms or heart diseases were prospectively included. Data from 32 GBPS acquisitions were reconstructed using an iterative algorithm with (IRAC) and without (IRNC) CT-AC and analyzed using previously described segmentation software based on the watershed algorithm. LV and RV EF and volumes were assessed with and without CT-AC and compared.

Results

EF and volumes were correlated (P < .001 for all parameters with r = 0.97 for LV and RV EF; r = 0.96 for LV EDV; r = 0.98 for LV ESV; r = 0.96 for RV EDV and ESV). The mean values using IRAC and IRNC were different for all parameters with lower EF (respectively, 49% ± 19% vs 51 %± 18%; P = .002 for LV EF and 50% ± 14% vs 54%±15%; P < .001 for RV EF) and higher volumes (respectively, 142 ± 41 mL vs 133 ± 40 mL; P < .001 and 79 ± 45 mL vs 71 ± 42 mL; P < .001 for LV EDV and ESV; 91 ± 32 mL vs 86 ± 31 mL; P = .003 and 48 ± 28 mL vs 43 ± 26 mL; P < .001 for RV EDV and ESV). Limits of agreement were −11% to 6% and −11% to 4% for LV and RV EF. We found wider limits of agreement for LV volumes (−13 to 32 mL for EDV and −10 to 27 mL for ESV) than for RV volumes (−13 to 23 mL for EDV and −9 to 20 mL for ESV). Taking into account all volumes, we found a trend with a significant positive correlation between means and differences in volumes assessed with and without CT-AC.

Conclusion

Assessment of both left and right ventricular functions by count-based GBPS with CT-AC showed higher volumes and lower EF. Differences were slight, especially for the range of normal to subnormal ventricular volumes.
Literatur
1.
Zurück zum Zitat White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987;76:44-51.PubMedCrossRef White HD, Norris RM, Brown MA, Brandt PW, Whitlock RM, Wild CJ. Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction. Circulation 1987;76:44-51.PubMedCrossRef
2.
Zurück zum Zitat Sharir T, Germano G, Kavanagh PB, Lai S, Cohen I, Lewin HC, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999;100:1035-42.PubMed Sharir T, Germano G, Kavanagh PB, Lai S, Cohen I, Lewin HC, et al. Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography. Circulation 1999;100:1035-42.PubMed
3.
Zurück zum Zitat Wang TJ, Evans JC, Benjamin EJ, Levy D, LeRoy EC, Vasan RS. Natural history of asymptomatic left ventricular systolic dysfunction in the community. Circulation 2003;108:977-82.PubMedCrossRef Wang TJ, Evans JC, Benjamin EJ, Levy D, LeRoy EC, Vasan RS. Natural history of asymptomatic left ventricular systolic dysfunction in the community. Circulation 2003;108:977-82.PubMedCrossRef
4.
Zurück zum Zitat Ghio S, Gavazzi A, Campana C, Inserra C, Klersy C, Sebastiani R, et al. Independent and additive prognostic value of right ventricular systolic function and pulmonary artery pressure in patients with chronic heart failure. J Am Coll Cardiol 2001;37:183-8.PubMedCrossRef Ghio S, Gavazzi A, Campana C, Inserra C, Klersy C, Sebastiani R, et al. Independent and additive prognostic value of right ventricular systolic function and pulmonary artery pressure in patients with chronic heart failure. J Am Coll Cardiol 2001;37:183-8.PubMedCrossRef
5.
Zurück zum Zitat Mariano-Goulart D, Collet H, Kotzki PO, Zanca M, Rossi M. Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds:application to the determination of right and left ejection fractions. Eur J Nucl Med 1998;25:1300-7.PubMedCrossRef Mariano-Goulart D, Collet H, Kotzki PO, Zanca M, Rossi M. Semi-automatic segmentation of gated blood pool emission tomographic images by watersheds:application to the determination of right and left ejection fractions. Eur J Nucl Med 1998;25:1300-7.PubMedCrossRef
6.
Zurück zum Zitat Daou D, Harel F, Helal BO, Fourme T, Colin P, Lebtahi R, et al. Electrocardiographically gated blood-pool SPECT and left ventricular function: Comparative value of 3 methods for ejection fraction and volume estimation. J Nucl Med 2001;42:1043-9.PubMed Daou D, Harel F, Helal BO, Fourme T, Colin P, Lebtahi R, et al. Electrocardiographically gated blood-pool SPECT and left ventricular function: Comparative value of 3 methods for ejection fraction and volume estimation. J Nucl Med 2001;42:1043-9.PubMed
7.
Zurück zum Zitat Mariano-Goulart D, Piot C, Boudousq V, Raczka F, Comte F, Eberle MC, et al. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: A preliminary study. Eur J Nucl Med 2001;28:506-13.PubMedCrossRef Mariano-Goulart D, Piot C, Boudousq V, Raczka F, Comte F, Eberle MC, et al. Routine measurements of left and right ventricular output by gated blood pool emission tomography in comparison with thermodilution measurements: A preliminary study. Eur J Nucl Med 2001;28:506-13.PubMedCrossRef
8.
Zurück zum Zitat Sibille L, Bouallegue FB, Bourdon A, Micheau A, Vernhet-Kovacsik H, Mariano-Goulart D. Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation. Nucl Med Commun 2011;32:121-8.PubMedCrossRef Sibille L, Bouallegue FB, Bourdon A, Micheau A, Vernhet-Kovacsik H, Mariano-Goulart D. Comparative values of gated blood-pool SPECT and CMR for ejection fraction and volume estimation. Nucl Med Commun 2011;32:121-8.PubMedCrossRef
9.
Zurück zum Zitat Mariano-Goulart D, Dechaux L, Rouzet F, Barbotte E, Caderas de Kerleau C, Rossi M, et al. Diagnosis of diffuse and localized arrhythmogenic right ventricular dysplasia by gated blood-pool SPECT. J Nucl Med 2007;48:1416-23.PubMedCrossRef Mariano-Goulart D, Dechaux L, Rouzet F, Barbotte E, Caderas de Kerleau C, Rossi M, et al. Diagnosis of diffuse and localized arrhythmogenic right ventricular dysplasia by gated blood-pool SPECT. J Nucl Med 2007;48:1416-23.PubMedCrossRef
10.
Zurück zum Zitat Caderas de Kerleau C, Ahronovitz E, Rossi M, Mariano-Goulart D. Automatic ventricular wall motion analysis by gated blood-pool emission tomography using deformations of an ideal time-activity curve. IEEE Trans Med Imaging 2004;23:485-91.PubMedCrossRef Caderas de Kerleau C, Ahronovitz E, Rossi M, Mariano-Goulart D. Automatic ventricular wall motion analysis by gated blood-pool emission tomography using deformations of an ideal time-activity curve. IEEE Trans Med Imaging 2004;23:485-91.PubMedCrossRef
11.
Zurück zum Zitat Nichols KJ, Van Tosh A, Wang Y, Palestro CJ, Reichek N. Validation of gated blood-pool SPECT regional left ventricular function measurements. J Nucl Med 2009;50:53-60.PubMedCrossRef Nichols KJ, Van Tosh A, Wang Y, Palestro CJ, Reichek N. Validation of gated blood-pool SPECT regional left ventricular function measurements. J Nucl Med 2009;50:53-60.PubMedCrossRef
12.
Zurück zum Zitat Nichols KJ, Van Tosh A, De Bondt P, Bergmann SR, Palestro CJ, Reichek N. Normal limits of gated blood pool SPECT count-based regional cardiac function parameters. Int J Cardiovasc Imaging 2008;24:717-25.PubMedCrossRef Nichols KJ, Van Tosh A, De Bondt P, Bergmann SR, Palestro CJ, Reichek N. Normal limits of gated blood pool SPECT count-based regional cardiac function parameters. Int J Cardiovasc Imaging 2008;24:717-25.PubMedCrossRef
13.
Zurück zum Zitat Pretorius PH, Xia W, King MA, Tsui BM, Pan TS, Villegas BJ. Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom. J Nucl Med 1997;38:1528-35.PubMed Pretorius PH, Xia W, King MA, Tsui BM, Pan TS, Villegas BJ. Evaluation of right and left ventricular volume and ejection fraction using a mathematical cardiac torso phantom. J Nucl Med 1997;38:1528-35.PubMed
14.
Zurück zum Zitat Seierstad T, Bogsrud T, Skretting A. Effects of photon attenuation on the determination of cardiac volumes from reconstructed counts in gated blood pool SPET. Eur J Nucl Med Mol Imaging 2004;31:399-402.PubMedCrossRef Seierstad T, Bogsrud T, Skretting A. Effects of photon attenuation on the determination of cardiac volumes from reconstructed counts in gated blood pool SPET. Eur J Nucl Med Mol Imaging 2004;31:399-402.PubMedCrossRef
15.
Zurück zum Zitat Bateman TM, Cullom SJ. Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. Semin Nucl Med 2005;35:37-51.PubMedCrossRef Bateman TM, Cullom SJ. Attenuation correction single-photon emission computed tomography myocardial perfusion imaging. Semin Nucl Med 2005;35:37-51.PubMedCrossRef
16.
Zurück zum Zitat Zaidi H, Hasegawa B. Determination of the attenuation map in emission tomography. J Nucl Med 2003;44:291-315.PubMed Zaidi H, Hasegawa B. Determination of the attenuation map in emission tomography. J Nucl Med 2003;44:291-315.PubMed
17.
18.
Zurück zum Zitat Lang TF, Hasegawa BH, Liew SC, Brown JK, Blankespoor SC, Reilly SM, et al. Description of a prototype emission-transmission computed tomography imaging system. J Nucl Med 1992;33:1881-7.PubMed Lang TF, Hasegawa BH, Liew SC, Brown JK, Blankespoor SC, Reilly SM, et al. Description of a prototype emission-transmission computed tomography imaging system. J Nucl Med 1992;33:1881-7.PubMed
19.
Zurück zum Zitat Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, et al. Gamma camera-mounted anatomical X-ray tomography: Technology, system characteristics and first images. Eur J Nucl Med 2000;27:619-27.PubMedCrossRef Bocher M, Balan A, Krausz Y, Shrem Y, Lonn A, Wilk M, et al. Gamma camera-mounted anatomical X-ray tomography: Technology, system characteristics and first images. Eur J Nucl Med 2000;27:619-27.PubMedCrossRef
20.
Zurück zum Zitat Patton JA, Delbeke D, Sandler MP. Image fusion using an integrated, dual-head coincidence camera with X-ray tube-based attenuation maps. J Nucl Med 2000;41:1364-8.PubMed Patton JA, Delbeke D, Sandler MP. Image fusion using an integrated, dual-head coincidence camera with X-ray tube-based attenuation maps. J Nucl Med 2000;41:1364-8.PubMed
21.
Zurück zum Zitat Slart RH, Tio RA, Zeebregts CJ, Willemsen AT, Dierckx RA, De Sutter J. Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes. Ann Nucl Med 2008;22:171-6.PubMedCrossRef Slart RH, Tio RA, Zeebregts CJ, Willemsen AT, Dierckx RA, De Sutter J. Attenuation corrected gated SPECT for the assessment of left ventricular ejection fraction and volumes. Ann Nucl Med 2008;22:171-6.PubMedCrossRef
22.
Zurück zum Zitat Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. Myocardial perfusion and function: Single photon emission computed tomography. J Nucl Cardiol 2007;14:e39-60.PubMedCrossRef Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. Myocardial perfusion and function: Single photon emission computed tomography. J Nucl Cardiol 2007;14:e39-60.PubMedCrossRef
23.
Zurück zum Zitat Hesse B, Lindhardt TB, Acampa W, Anagnostopoulos C, Ballinger J, Bax JJ, et al. EANM/ESC guidelines for radionuclide imaging of cardiac function. Eur J Nucl Med Mol Imaging 2008;35:851-85.PubMedCrossRef Hesse B, Lindhardt TB, Acampa W, Anagnostopoulos C, Ballinger J, Bax JJ, et al. EANM/ESC guidelines for radionuclide imaging of cardiac function. Eur J Nucl Med Mol Imaging 2008;35:851-85.PubMedCrossRef
24.
Zurück zum Zitat Hamann M, Aldridge M, Dickson J, Endozo R, Lozhkin K, Hutton BF. Evaluation of a low-dose/slow-rotating SPECT-CT system. Phys Med Biol 2008;53:2495-508.PubMedCrossRef Hamann M, Aldridge M, Dickson J, Endozo R, Lozhkin K, Hutton BF. Evaluation of a low-dose/slow-rotating SPECT-CT system. Phys Med Biol 2008;53:2495-508.PubMedCrossRef
25.
Zurück zum Zitat Tonge CM, Ellul G, Pandit M, Lawson RS, Shields RA, Arumugam P, et al. The value of registration correction in the attenuation correction of myocardial SPECT studies using low resolution computed tomography images. Nucl Med Commun 2006;27:843-52.PubMedCrossRef Tonge CM, Ellul G, Pandit M, Lawson RS, Shields RA, Arumugam P, et al. The value of registration correction in the attenuation correction of myocardial SPECT studies using low resolution computed tomography images. Nucl Med Commun 2006;27:843-52.PubMedCrossRef
26.
Zurück zum Zitat Jaszczak RJ, Floyd CE, Coleman RE. Scatter compensation techniques for SPECT. IEEE Trans Nucl Sci 1985;32:786-93.CrossRef Jaszczak RJ, Floyd CE, Coleman RE. Scatter compensation techniques for SPECT. IEEE Trans Nucl Sci 1985;32:786-93.CrossRef
27.
Zurück zum Zitat Mariano-Goulart D, Caderas de Kerleau C, Rossi M. Automatic measurements of local ventricular parameters using Gated Blood-Pool Emission tomography. Médecine nucléaire 2005;29:115-30. Mariano-Goulart D, Caderas de Kerleau C, Rossi M. Automatic measurements of local ventricular parameters using Gated Blood-Pool Emission tomography. Médecine nucléaire 2005;29:115-30.
28.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.PubMedCrossRef Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.PubMedCrossRef
29.
Zurück zum Zitat Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK, et al. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 2005;236:57-64.PubMedCrossRef Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK, et al. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology 2005;236:57-64.PubMedCrossRef
Metadaten
Titel
Influence of CT-based attenuation correction in assessment of left and right ventricular functions with count-based gated blood-pool SPECT
verfasst von
Louis Sibille, MD
Fayçal Ben Bouallegue, PhD
Aurélie Bourdon, MD
Denis Mariano-Goulart, PhD
Publikationsdatum
01.08.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 4/2011
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-011-9407-7

Weitere Artikel der Ausgabe 4/2011

Journal of Nuclear Cardiology 4/2011 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.