Excerpt

Please note the correction in Table 5 of the published article. Under the heading “Second Injection” and subhead “Activity (MBq),” the third row of numbers, which currently reads “888-1332,” should read “296-444”. The correct Table 5 is given here.
Table 5
Current SPECT myocardial perfusion imaging protocols: recommended radiopharmaceutical activities and their corresponding radiation effective doses
 
First injection
Second injection
Total
Total dose if
Given at
Activity (mCi)
Activity (MBq)
Dose (mSv)
Given at
Activity (mCi)
Activity (MBq)
Dose (mSv)
Dose (mSv)
Stress only (mSv)
Tc-99m protocols
 Tc-99m one-day stress-first/stress-only
Stress
8–12
296–444
2.0–3.0
(Rest)
24–36
888–1332
7.0–10.5
9.0–13.5
2.0–3.0
 Tc-99m one-day rest/stress
Rest
8–12
296–444
2.3–3.5
Stress
24–36
888–1332
6.1–9.1
8.4–12.6
n/a
 Tc-99m two-day stress/rest
Stress
8–12
296–444
2.0–3.0
(Rest)
8–12
296–444
2.3–3.5
4.3–6.5
2.0–3.0
 Tc-99m two-day stress/rest—large patient
Stress
18–30
666–1110
4.5–7.6
(Rest)
18–30
666–1110
5.2–8.7
9.8–16.3
4.5–7.6
 Tc-99m two-day rest/stress
Rest
8–12
296–444
2.3–3.5
Stress
8–12
296–444
2.0–3.0
4.3–6.5
n/a
 Tc-99m two-day rest/stress large patient
Rest
18–30
666–1110
5.2–8.7
Stress
18–30
666–1110
4.5–7.6
9.8–16.3
n/a
Tl-201 protocols
 Tl-201 stress/redistribution rest
Stress
2.5–3.5
92.5–129.5
10.9–15.3
n/a
n/a
n/a
n/a
10.9–15.3
10.9–15.3
 Tl-201 stress/redistribution rest/reinjection
Stress
2.5–3.5
92.5–129.5
10.9–15.3
Rest
1–2
37–74
4.4–8.8
15.3–24.1
n/a
 Tl-201 rest/redistribution
Rest
2.5–3.5
92.5–129.5
10.9–15.3
n/a
n/a
n/a
n/a
10.9–15.3
n/a
 Dual-isotope Tl-201 rest/Tc-99m stress
Rest
2.5–3.5
92.5–129.5
10.9–15.3
Stress
8–12
296–444
2.0–3.0
13.0–18.3
n/a
 Dual-isotope Tl-201 rest/Tc-99m stress—large patient
Rest
3.0–3.5
111–129.5
13.1–15.3
Stress
18–30
666–1110
4.5–7.6
17.7–22.9
n/a
I-123 protocol
 MIBG
Rest
10
370
4.6
n/a
n/a
n/a
n/a
4.6
n/a
Newer technology reduced-dose protocols
 Tc-99m one-day stress-first/stress-only
Stress
4–6
148–222
1.0–1.5
(Rest)
12–18
444–666
3.5–5.2
4.5–6.7
1.0–1.5
 Tc-99m one-day rest/stress
Rest
4–6
148–222
1.2–1.7
Stress
12–18
444–666
3.0–4.5
4.2–6.3
n/a
 Tc-99m two-day stress/rest
Stress
4–6
148–222
1.0–1.5
(Rest)
4–6
148–222
1.2–1.7
2.2–3.3
1.0–1.5
 Tc-99m two-day stress/rest—large patient
Stress
9–15
333–555
2.3–3.8
(Rest)
9–15
333–555
2.6–4.4
4.9–8.1
2.3–3.8
 Tc-99m two-day rest/stress
Rest
4–6
148–222
1.2–1.7
Stress
4–6
148–222
1.0–1.5
2.2–3.3
n/a
 Tc-99m two-day rest/stress—large patient
Rest
9–15
333–555
2.6–4.4
Stress
9–15
333–555
2.3–3.8
4.9–8.1
n/a
 Tl-201 stress/redistribution rest
Stress
1.3–1.8
48.1–66.6
5.7–7.9
n/a
n/a
n/a
n/a
5.7–7.9
5.7–7.9
 Dual-isotope Tl-201 rest/Tc-99m stress
Rest
1.3–1.8
48.1–66.6
5.7–7.9
Stress
4–6
148–222
1.0–1.5
6.7–9.4
n/a
 Dual-isotope Tl-201 stress/Tc-99m rest
Stress
1.3–1.8
48.1–66.6
5.7–7.9
(Rest)
4–6
148–222
1.2–1.7
6.9–9.6
5.7–7.9
Note that 1 mCi = 37 MBq, e.g., activity of 8 to 12 mCi = 8 × 37 to 12 × 37 MBq = 296 to 444 MBq. Note >3:1 ratio of activity of the second injection to that of the first injection. For example, the range for dose #1 is 8–12 mCi, and the range for dose #2 is 24–36 mCi. (Rest) denotes optional rest injection; it is recommended that stress images be reviewed by a nuclear cardiology physician prior to rest injection, and the rest injection only performed where clinically warranted.* Newer technology reduced-dose protocols have been studied for high-efficiency cameras,** and for image reconstruction with iterative reconstruction, depth-dependent resolution recovery, and noise modeling. Radiation effective dose values listed here are dose to a reference individual. Doses were determined using the most recent published International Commission on Radiological Protection (ICRP) organ dose coefficients, and ICRP Publication 103 tissue weighing factors. Tc-99m doses represent an average for sestamibi and tetrofosmin
* Gibson, Chang, Duvall77-79
** Einstein, Duvall73,74
*** DePuey72
Metadaten
Titel
Erratum to: ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers
verfasst von
Milena J. Henzlova, MD
W. Lane Duvall, MD
Andrew J. Einstein, MD
Mark I. Travin, MD
Hein J. Verberne, MD
Publikationsdatum
01.06.2016
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 3/2016
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-016-0463-x

Weitere Artikel der Ausgabe 3/2016

Journal of Nuclear Cardiology 3/2016 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.