Skip to main content
Erschienen in: Journal of Nuclear Cardiology 6/2017

01.12.2017 | Theme Article

Reducing radiation to patients and improving image quality in a real-world nuclear cardiology laboratory

verfasst von: Stephen A. Bloom, MD, FASNC, Karen Meyers, BS, CNMT, ARRT(N)

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 6/2017

Einloggen, um Zugang zu erhalten

Abstract

In part because of aging equipment and reduced reimbursement for imaging services in the last several years, nuclear cardiologists who remain in private practice face challenges in maintaining high quality and in reducing radiation exposure to patients. We review patient-centered approaches and affordable software solutions employed in our practice combined with supine-prone myocardial perfusion imaging to achieve increased interpretive confidence with reduced radiation exposure to patients.
Literatur
2.
Zurück zum Zitat Bateman TM, Heller GV, McGhie AI, Courter SA, Golub RA, Case JA, et al Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imaging. J Nucl Cardiol 2009;16:726-35. doi:10.1007/s12350-009-9109-6.CrossRefPubMed Bateman TM, Heller GV, McGhie AI, Courter SA, Golub RA, Case JA, et al Multicenter investigation comparing a highly efficient half-time stress-only attenuation correction approach against standard rest-stress Tc-99m SPECT imaging. J Nucl Cardiol 2009;16:726-35. doi:10.​1007/​s12350-009-9109-6.CrossRefPubMed
3.
Zurück zum Zitat Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.CrossRefPubMed Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, et al Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol 2010;17:709-18.CrossRefPubMed
4.
Zurück zum Zitat Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress only versus standard stress/rest myocardial perfusion imaging: Similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed Chang SM, Nabi F, Xu J, Raza U, Mahmarian JJ. Normal stress only versus standard stress/rest myocardial perfusion imaging: Similar patient mortality with reduced radiation exposure. J Am Coll Cardiol 2010;55:221-30.CrossRefPubMed
5.
Zurück zum Zitat Taasan V, Wokhlu A, Taasan MV, Dusaj RS, Mehta A, Kraft S, et al Comparative accuracy of supine-only and combined supine-prone myocardial perfusion imaging in men. J Nucl Cardiol 2016;23:1470-6.CrossRefPubMed Taasan V, Wokhlu A, Taasan MV, Dusaj RS, Mehta A, Kraft S, et al Comparative accuracy of supine-only and combined supine-prone myocardial perfusion imaging in men. J Nucl Cardiol 2016;23:1470-6.CrossRefPubMed
6.
Zurück zum Zitat Cohen MC. Combined supine and prone imaging acquisition in cardiac SPECT: A turn for the better. J Nucl Cardiol 2016;23:1470-6.CrossRef Cohen MC. Combined supine and prone imaging acquisition in cardiac SPECT: A turn for the better. J Nucl Cardiol 2016;23:1470-6.CrossRef
7.
Zurück zum Zitat Henzlova MJ, Duvall WL, Einstein AJ, Travin MI, Verberne HJ. ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J Nucl Cardiol 2016;23:606-39.CrossRefPubMed Henzlova MJ, Duvall WL, Einstein AJ, Travin MI, Verberne HJ. ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J Nucl Cardiol 2016;23:606-39.CrossRefPubMed
8.
Zurück zum Zitat Einstein AJ, Berman DS, Min JK, Hendel RC, Gerber TC, Carr JJ, et al Patient-centered imaging: Shared decision making for cardiac imaging procedures with exposure to ionizing radiation. J Am Coll Cardiol 2014;63:1480-9.CrossRefPubMedPubMedCentral Einstein AJ, Berman DS, Min JK, Hendel RC, Gerber TC, Carr JJ, et al Patient-centered imaging: Shared decision making for cardiac imaging procedures with exposure to ionizing radiation. J Am Coll Cardiol 2014;63:1480-9.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Jha S, Boom W. Patient-centered imaging: Opportunities and challenges. J Am Coll Radiol 2012;9:157-9.CrossRefPubMed Jha S, Boom W. Patient-centered imaging: Opportunities and challenges. J Am Coll Radiol 2012;9:157-9.CrossRefPubMed
10.
11.
Zurück zum Zitat Depuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M. A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol 2011;18:273-80.CrossRefPubMed Depuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M. A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol 2011;18:273-80.CrossRefPubMed
12.
Zurück zum Zitat Hayes SW, Lorenzo AD, Hachamovitch R, Ohar SC, Hsu P, Cohen I, et al Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed Hayes SW, Lorenzo AD, Hachamovitch R, Ohar SC, Hsu P, Cohen I, et al Prognostic implications of combined prone and supine acquisitions in patients with equivocal or abnormal supine myocardial perfusion SPECT. J Nucl Med 2003;44:1633-40.PubMed
13.
Zurück zum Zitat Reyes E, Wiener S, European Council of Nuclear Cardiology. Myocardial perfusion scintigraphy in Europe 2007; a survey of the European Council of Nuclear Cardiology. Eur J Nucl Mol Imaging 2007;2012(39):160-4. Reyes E, Wiener S, European Council of Nuclear Cardiology. Myocardial perfusion scintigraphy in Europe 2007; a survey of the European Council of Nuclear Cardiology. Eur J Nucl Mol Imaging 2007;2012(39):160-4.
Metadaten
Titel
Reducing radiation to patients and improving image quality in a real-world nuclear cardiology laboratory
verfasst von
Stephen A. Bloom, MD, FASNC
Karen Meyers, BS, CNMT, ARRT(N)
Publikationsdatum
01.12.2017
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 6/2017
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-017-0851-x

Weitere Artikel der Ausgabe 6/2017