Skip to main content
Erschienen in: Journal of Nuclear Cardiology 6/2017

01.12.2017 | Original Article

Current status of stress myocardial perfusion imaging pharmaceuticals and radiation exposure in Japan: Results from a nationwide survey

verfasst von: Ryuto Otsuka, MS, Narumi Kubo, MS, Yosuke Miyazaki, MS, Mio Kawahara, MS, Jun Takaesu, MS, Kazuki Fukuchi, MD, PhD

Erschienen in: Journal of Nuclear Cardiology | Ausgabe 6/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Ionizing radiation generated during medical imaging procedures is a matter of concern. However, the current status of radiopharmaceutical use in stress myocardial perfusion imaging (MPI) and the radiation exposure from these radiopharmaceuticals is unknown in Japan.

Methods and Results

A nationwide survey was conducted from June through July 2016. The questionnaires on the radiopharmaceuticals used and their administered doses during stress MPI were sent to 641 nuclear medicine facilities. The responses were collected from 431 facilities and the effective dose (ED) for an adult with standard body weight was calculated. Forty-three percent of the facilities used only 201TlCl, 35% used only 99mTc radiopharmaceuticals, and the remaining 22% used both. The two main reasons for using 201TlCl instead of 99mTc radiopharmaceuticals were “more familiarity with the usage of 201TlCl than 99mTc radiopharmaceuticals” and “apprehension about increasing the burden of physicians performing tracer injection twice.” The mean ED was 14.0 ± 5.5 mSv (range, 3.9 to 25.2 mSv), which was higher than that reported in other countries.

Conclusions

The ED of stress MPI radiopharmaceuticals in Japan is probably higher than the world standard because more than 50% of the facilities still use 201TlCl. We recommend revising the routine stress MPI protocol to reduce the effects of ionizing radiation.
Literatur
1.
Zurück zum Zitat Carpeggiani C, Picano E, Brambilla M, Michelassi C, Knuuti J, Kauffman P, et al. Variability of radiation doses of cardiac diagnostic imaging tests: The RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study). BMC Cardiovasc Disord 2017;17:63.CrossRefPubMedPubMedCentral Carpeggiani C, Picano E, Brambilla M, Michelassi C, Knuuti J, Kauffman P, et al. Variability of radiation doses of cardiac diagnostic imaging tests: The RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study). BMC Cardiovasc Disord 2017;17:63.CrossRefPubMedPubMedCentral
2.
Zurück zum Zitat Lecchi M, Malaspina S, Scabbio C, Gaudieri V, Del Sole A. Myocardial perfusion scintigraphy dosimetry: Optimal use of SPECT and SPECT/CT technologies in stress-first imaging protocol. Clin Transl Imaging 2016;4:491-8.CrossRefPubMedPubMedCentral Lecchi M, Malaspina S, Scabbio C, Gaudieri V, Del Sole A. Myocardial perfusion scintigraphy dosimetry: Optimal use of SPECT and SPECT/CT technologies in stress-first imaging protocol. Clin Transl Imaging 2016;4:491-8.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Becker MD, Butler PF, Bhargavan-Chatfield M, Harkness BA, Metter D, MacFarlane CR, et al. Adult gamma camera myocardial perfusion imaging: Diagnostic reference levels and achievable administered activities derived from ACR accreditation data. J Am Coll Radiol 2016;13:688-95.CrossRefPubMed Becker MD, Butler PF, Bhargavan-Chatfield M, Harkness BA, Metter D, MacFarlane CR, et al. Adult gamma camera myocardial perfusion imaging: Diagnostic reference levels and achievable administered activities derived from ACR accreditation data. J Am Coll Radiol 2016;13:688-95.CrossRefPubMed
4.
Zurück zum Zitat Jerome SD, Tilkemeier PL, Farrell MB, Shaw LJ. Nationwide laboratory adherence to myocardial perfusion imaging radiation dose reduction practices. JACC Cardiovasc Imaging 2015;8:1170-6.CrossRefPubMed Jerome SD, Tilkemeier PL, Farrell MB, Shaw LJ. Nationwide laboratory adherence to myocardial perfusion imaging radiation dose reduction practices. JACC Cardiovasc Imaging 2015;8:1170-6.CrossRefPubMed
5.
Zurück zum Zitat Inubushi M, Higashi T, Kuji I, Sakamoto S, Tashiro M, Momose M. Introduction of nuclear medicine research in Japan. Eur J Nucl Med Mol Imaging 2016;43:2449-52.CrossRefPubMedPubMedCentral Inubushi M, Higashi T, Kuji I, Sakamoto S, Tashiro M, Momose M. Introduction of nuclear medicine research in Japan. Eur J Nucl Med Mol Imaging 2016;43:2449-52.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Okuda K, Nakajima K, Matsuo S, Kondo C, Sarai M, Horiguchi Y, et al. Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system. J Nucl Cardiol 2017; doi:10.1007/s12350-016-0770-2. Okuda K, Nakajima K, Matsuo S, Kondo C, Sarai M, Horiguchi Y, et al. Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system. J Nucl Cardiol 2017; doi:10.​1007/​s12350-016-0770-2.
7.
Zurück zum Zitat Watanabe H, Ishii K, Hosono M, Imabayashi E, Abe K, Inubushi M, et al. Report of a nationwide survey on actual administered radioactivities of radiopharmaceuticals for diagnostic reference levels in Japan. Ann Nucl Med 2016;30:435-44.CrossRefPubMedPubMedCentral Watanabe H, Ishii K, Hosono M, Imabayashi E, Abe K, Inubushi M, et al. Report of a nationwide survey on actual administered radioactivities of radiopharmaceuticals for diagnostic reference levels in Japan. Ann Nucl Med 2016;30:435-44.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Einstein AJ, Pascual TN, Mercuri M, Karthikeyan G, Vitola JV, Mahmarian JJ, et al. Current worldwide nuclear cardiology practices and radiation exposure: Results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). Eur Heart J 2015;36:1689-96.CrossRefPubMedPubMedCentral Einstein AJ, Pascual TN, Mercuri M, Karthikeyan G, Vitola JV, Mahmarian JJ, et al. Current worldwide nuclear cardiology practices and radiation exposure: Results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS). Eur Heart J 2015;36:1689-96.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Mercuri M, Pascual TN, Mahmarian JJ, Shaw LJ, Rehani MM, Paez D, et al. Comparison of radiation doses and best-practice use for myocardial perfusion imaging in US and Non-US laboratories: Findings from the IAEA (International Atomic Energy Agency) nuclear cardiology protocols study. JAMA Intern Med 2016;176:266-9.CrossRefPubMed Mercuri M, Pascual TN, Mahmarian JJ, Shaw LJ, Rehani MM, Paez D, et al. Comparison of radiation doses and best-practice use for myocardial perfusion imaging in US and Non-US laboratories: Findings from the IAEA (International Atomic Energy Agency) nuclear cardiology protocols study. JAMA Intern Med 2016;176:266-9.CrossRefPubMed
10.
Zurück zum Zitat Lindner O, Burchert W, Schäfer W, Hacker M. Myocardial perfusion SPECT 2015 in Germany. Results of the 7th survey. Nuklearmedizin 2017;56:31-8.CrossRefPubMed Lindner O, Burchert W, Schäfer W, Hacker M. Myocardial perfusion SPECT 2015 in Germany. Results of the 7th survey. Nuklearmedizin 2017;56:31-8.CrossRefPubMed
11.
Zurück zum Zitat Lindner O, Pascual TN, Mercuri M, Acampa W, Burchert W, Flotats A, et al. Nuclear cardiology practice and associated radiation doses in Europe: Results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries. Eur J Nucl Med Mol Imaging 2016;43:718-28.CrossRefPubMed Lindner O, Pascual TN, Mercuri M, Acampa W, Burchert W, Flotats A, et al. Nuclear cardiology practice and associated radiation doses in Europe: Results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries. Eur J Nucl Med Mol Imaging 2016;43:718-28.CrossRefPubMed
12.
Zurück zum Zitat Jiang Z, Liu Y, Xin C, Zhou Y, Wang C, Zhao Z, et al. Normal stress-only myocardial single photon emission computed tomography predicts good outcome in patients with coronary artery stenoses between 40 and 70. Nucl Med Commun 2016;37:899-903.CrossRefPubMed Jiang Z, Liu Y, Xin C, Zhou Y, Wang C, Zhao Z, et al. Normal stress-only myocardial single photon emission computed tomography predicts good outcome in patients with coronary artery stenoses between 40 and 70. Nucl Med Commun 2016;37:899-903.CrossRefPubMed
13.
Zurück zum Zitat Palyo RJ, Sinusas AJ, Liu YH. High-sensitivity and high-resolution SPECT/CT systems provide substantial dose reduction without compromising quantitative precision for assessment of myocardial perfusion and function. J Nucl Med 2016;57:893-9.CrossRefPubMed Palyo RJ, Sinusas AJ, Liu YH. High-sensitivity and high-resolution SPECT/CT systems provide substantial dose reduction without compromising quantitative precision for assessment of myocardial perfusion and function. J Nucl Med 2016;57:893-9.CrossRefPubMed
14.
Zurück zum Zitat SNMMI, ASNC, IAC and Nuclear Cardiology Dose. J Nucl Med 2017;58:15N. SNMMI, ASNC, IAC and Nuclear Cardiology Dose. J Nucl Med 2017;58:15N.
Metadaten
Titel
Current status of stress myocardial perfusion imaging pharmaceuticals and radiation exposure in Japan: Results from a nationwide survey
verfasst von
Ryuto Otsuka, MS
Narumi Kubo, MS
Yosuke Miyazaki, MS
Mio Kawahara, MS
Jun Takaesu, MS
Kazuki Fukuchi, MD, PhD
Publikationsdatum
01.12.2017
Verlag
Springer US
Erschienen in
Journal of Nuclear Cardiology / Ausgabe 6/2017
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-017-0867-2

Weitere Artikel der Ausgabe 6/2017

Journal of Nuclear Cardiology 6/2017 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.