Skip to main content

08.03.2018 | Original Article

Assessment of left ventricular ejection fraction with cardiofocal collimators: Comparison between IQ-SPECT, planar equilibrium radionuclide angiography, and cardiac magnetic resonance

verfasst von: Matthieu Pelletier-Galarneau, MD, MSc, Vincent Finnerty, MSc, Stephanie Tan, MD, Sebastien Authier, B Eng, Jean Gregoire, MD, Francois Harel, MD, PhD

Erschienen in: Journal of Nuclear Cardiology

Einloggen, um Zugang zu erhalten

Abstract

Background

IQ-SPECT has been shown to significantly reduce acquisition time and administered dose while preserving image quality in myocardial perfusion imaging. Whether IQ-SPECT provides accurate left ventricular ejection fractions (LVEF) with gated blood pool SPECT (GBPS) remains unknown.

Methods

Sixty patients underwent IQ-SPECT GBPS and planar imaging. Among those patients, 11 underwent both cMRI and GBPS. GBPS LVEF, LVEDV, and LVESV were calculated using 2 validated software; QBS (Cedars-Sinai Medical Center, Los Angeles, USA) and MHI (Montreal Heart Institute, Montreal, Canada). LVEF, LVEDV, and LVESV obtained with the different modalities were compared.

Results

Average planar LVEF was 48 ± 11% (mean ± SD), average LVEDV was 177 ± 59 mL (range 63 to 342 mL), and average LVESV was 96 ± 46 mL (range 16 to 234 mL). GBPS LVEF and their correlation coefficient with planar LVEF were 40 ± 12% (r = 0.70) and 44 ± 12% (r = 0.83) with QBS and MHI, respectively. Correlation coefficient between cMRI and planar LVEF was 0.65 and were 0.69 and 0.52 between cMRI and GBPS using QBS and MHI, respectively.

Conclusions

LVEF calculated with GBPS using IQ-SPECT correlates with planar measurements. Correlation is best using the MHI method and variation is independent of LVEDV.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Wittry MD, Juni JE, Royal HD, Heller GV, Port SC. Procedure guideline for equilibrium radionuclide ventriculography J Nucl Med 1997;38:1658.PubMed Wittry MD, Juni JE, Royal HD, Heller GV, Port SC. Procedure guideline for equilibrium radionuclide ventriculography J Nucl Med 1997;38:1658.PubMed
2.
Zurück zum Zitat Cardinale D, Colombo A, Cipolla CM. Prevention and treatment of cardiomyopathy and heart failure in patients receiving cancer chemotherapy Curr Treat Options Cardiovasc Med 2008;10:486-95.CrossRef Cardinale D, Colombo A, Cipolla CM. Prevention and treatment of cardiomyopathy and heart failure in patients receiving cancer chemotherapy Curr Treat Options Cardiovasc Med 2008;10:486-95.CrossRef
3.
Zurück zum Zitat Wackers FJT. Equilibrium gated radionuclide angiocardiography: Its invention, rise, and decline and … comeback? J Nucl Cardiol 2016;23:362-5.CrossRef Wackers FJT. Equilibrium gated radionuclide angiocardiography: Its invention, rise, and decline and … comeback? J Nucl Cardiol 2016;23:362-5.CrossRef
4.
Zurück zum Zitat Harel F, Finnerty V, Grégoire J, Thibault B, Marcotte F, Marcotte P, et al. Gated blood-pool SPECT versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction. J Nucl Cardiol 2010;17:427-34.CrossRef Harel F, Finnerty V, Grégoire J, Thibault B, Marcotte F, Marcotte P, et al. Gated blood-pool SPECT versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction. J Nucl Cardiol 2010;17:427-34.CrossRef
5.
Zurück zum Zitat Nichols KJ, Van Tosh A, Wang Y, Palestro CJ, Reichek N. Validation of gated blood-pool SPECT regional left ventricular function measurements. J Nucl Med 2009;50:53-60.CrossRef Nichols KJ, Van Tosh A, Wang Y, Palestro CJ, Reichek N. Validation of gated blood-pool SPECT regional left ventricular function measurements. J Nucl Med 2009;50:53-60.CrossRef
6.
Zurück zum Zitat Xie B-Q, Tian Y-Q, Zhang J, Zhao SH, Yang MF, Guo F, et al. Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy: Comparison with cardiac MRI. J Nucl Med 2012;53:584-91.CrossRef Xie B-Q, Tian Y-Q, Zhang J, Zhao SH, Yang MF, Guo F, et al. Evaluation of left and right ventricular ejection fraction and volumes from gated blood-pool SPECT in patients with dilated cardiomyopathy: Comparison with cardiac MRI. J Nucl Med 2012;53:584-91.CrossRef
7.
Zurück zum Zitat Faber TL, Stokely EM, Templeton GH, Akers MS, Parkey RW, Corbett JR. Quantification of three-dimensional left ventricular segmental wall motion and volumes from gated tomographic radionuclide ventriculograms. J Nucl Med 1989;30:638-49.PubMed Faber TL, Stokely EM, Templeton GH, Akers MS, Parkey RW, Corbett JR. Quantification of three-dimensional left ventricular segmental wall motion and volumes from gated tomographic radionuclide ventriculograms. J Nucl Med 1989;30:638-49.PubMed
8.
Zurück zum Zitat Everaert H, Vanhove C, Hamill JJ, Franken PR. Cardiofocal collimators for gated single-photon emission tomographic myocardial perfusion imaging. Eur J Nucl Med 1998;25:3-7.CrossRef Everaert H, Vanhove C, Hamill JJ, Franken PR. Cardiofocal collimators for gated single-photon emission tomographic myocardial perfusion imaging. Eur J Nucl Med 1998;25:3-7.CrossRef
9.
Zurück zum Zitat Hawman PC, Haines EJ. The cardiofocal collimator: A variable-focus collimator for cardiac SPECT. Phys Med Biol 1994;39:439-50.CrossRef Hawman PC, Haines EJ. The cardiofocal collimator: A variable-focus collimator for cardiac SPECT. Phys Med Biol 1994;39:439-50.CrossRef
10.
Zurück zum Zitat DePuey EG. Advances in SPECT camera software and hardware: Currently available and new on the horizon. J Nucl Cardiol 2012;19:551-81.CrossRef DePuey EG. Advances in SPECT camera software and hardware: Currently available and new on the horizon. J Nucl Cardiol 2012;19:551-81.CrossRef
11.
Zurück zum Zitat Hippeläinen E, Mäkelä T, Kaasalainen T, Kaleva E. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: Comparison between IQ-SPECT and LEHR. EJNMMI Phys 2017;4:20.CrossRef Hippeläinen E, Mäkelä T, Kaasalainen T, Kaleva E. Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: Comparison between IQ-SPECT and LEHR. EJNMMI Phys 2017;4:20.CrossRef
12.
Zurück zum Zitat Yoneyama H, Shibutani T, Konishi T, Mizutani A, Hashimoto R, Onoguchi M, et al. Validation of left ventricular ejection fraction with the IQ SPECT system in small-heart patients. J Nucl Med Technol 2017;45:201-7.CrossRef Yoneyama H, Shibutani T, Konishi T, Mizutani A, Hashimoto R, Onoguchi M, et al. Validation of left ventricular ejection fraction with the IQ SPECT system in small-heart patients. J Nucl Med Technol 2017;45:201-7.CrossRef
14.
Zurück zum Zitat Caobelli F, Kaiser SR, Thackeray JT, Bengel FM, Chieregato M, Soffientini A, et al. IQ SPECT allows a significant reduction in administered dose and acquisition time for myocardial perfusion imaging: Evidence from a phantom study. J Nucl Med 2014;55:2064-70.CrossRef Caobelli F, Kaiser SR, Thackeray JT, Bengel FM, Chieregato M, Soffientini A, et al. IQ SPECT allows a significant reduction in administered dose and acquisition time for myocardial perfusion imaging: Evidence from a phantom study. J Nucl Med 2014;55:2064-70.CrossRef
15.
Zurück zum Zitat Caobelli F, Thackeray JT, Soffientini A, Bengel FM, Pizzocaro C, Guerra UP. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT. Eur J Nucl Med Mol Imaging 2015;42:1920-8.CrossRef Caobelli F, Thackeray JT, Soffientini A, Bengel FM, Pizzocaro C, Guerra UP. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT. Eur J Nucl Med Mol Imaging 2015;42:1920-8.CrossRef
16.
Zurück zum Zitat Caobelli F, Pizzocaro C, Paghera B, Guerra UP. Evaluation of patients with coronary artery disease IQ-SPECT protocol in myocardial perfusion imaging: Preliminary results. Nukl Nucl Med 2013;52:178-85.CrossRef Caobelli F, Pizzocaro C, Paghera B, Guerra UP. Evaluation of patients with coronary artery disease IQ-SPECT protocol in myocardial perfusion imaging: Preliminary results. Nukl Nucl Med 2013;52:178-85.CrossRef
17.
Zurück zum Zitat Lyon MC, Foster C, Ding X, Dorbala S, Spence D, Bhattacharya M, et al. Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation. J Nucl Cardiol 2016;23:657-67.CrossRef Lyon MC, Foster C, Ding X, Dorbala S, Spence D, Bhattacharya M, et al. Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation. J Nucl Cardiol 2016;23:657-67.CrossRef
18.
Zurück zum Zitat Pirich C, Keinrath P, Barth G, Rendl G, Rettenbacher L, Rodrigues M. Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging. Q J Nucl Med Mol Imaging 2014;61:102-7.PubMed Pirich C, Keinrath P, Barth G, Rendl G, Rettenbacher L, Rodrigues M. Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging. Q J Nucl Med Mol Imaging 2014;61:102-7.PubMed
19.
Zurück zum Zitat Matsuo S, Nakajima K, Onoguchi M, Wakabayash H, Okuda K, Kinuya S. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects. Ann Nucl Med 2015;29:452-9.CrossRef Matsuo S, Nakajima K, Onoguchi M, Wakabayash H, Okuda K, Kinuya S. Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects. Ann Nucl Med 2015;29:452-9.CrossRef
20.
Zurück zum Zitat Erwin WD, Jessop AC, Mar MV, Macapinlac HA, Mawlawi OR. Qualitative and quantitative comparison of gated blood pool single photon emission computed tomography using low-energy high-resolution and SMARTZOOM collimation. Nucl Med Commun 2017;38:35-43.CrossRef Erwin WD, Jessop AC, Mar MV, Macapinlac HA, Mawlawi OR. Qualitative and quantitative comparison of gated blood pool single photon emission computed tomography using low-energy high-resolution and SMARTZOOM collimation. Nucl Med Commun 2017;38:35-43.CrossRef
21.
Zurück zum Zitat Nakajima K, Okuda K, Momose M, Matsuo S, Kondo C, Sarai M, et al. IQ SPECT technology and its clinical applications using multicenter normal databases. Ann Nucl Med 2017;31:649-59.CrossRef Nakajima K, Okuda K, Momose M, Matsuo S, Kondo C, Sarai M, et al. IQ SPECT technology and its clinical applications using multicenter normal databases. Ann Nucl Med 2017;31:649-59.CrossRef
22.
Zurück zum Zitat Gremillet E, Agostini D. How to use cardiac IQ SPECT routinely? An overview of tips and tricks from practical experience to the literature. Eur J Nucl Med Mol Imaging 2016;43:707-10.CrossRef Gremillet E, Agostini D. How to use cardiac IQ SPECT routinely? An overview of tips and tricks from practical experience to the literature. Eur J Nucl Med Mol Imaging 2016;43:707-10.CrossRef
23.
Zurück zum Zitat Harel F, Finnerty V, Ngo Q, Grégoire J, Khairy P, Thibault B. SPECT versus planar gated blood pool imaging for left ventricular evaluation. J Nucl Cardiol 2007;14:544-9.CrossRef Harel F, Finnerty V, Ngo Q, Grégoire J, Khairy P, Thibault B. SPECT versus planar gated blood pool imaging for left ventricular evaluation. J Nucl Cardiol 2007;14:544-9.CrossRef
24.
Zurück zum Zitat Harel F, Finnerty V, Grégoire J, Thibault B, Khairy P. Comparison of left ventricular contraction homogeneity index using SPECT gated blood pool imaging and planar phase analysis. J Nucl Cardiol 2008;15:80-5.CrossRef Harel F, Finnerty V, Grégoire J, Thibault B, Khairy P. Comparison of left ventricular contraction homogeneity index using SPECT gated blood pool imaging and planar phase analysis. J Nucl Cardiol 2008;15:80-5.CrossRef
25.
Zurück zum Zitat Schulz-Menger J, Bluemke DA, Bremerich J, Flamm S, Fogel MA, Friedrich MG, et al. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing. J Cardiovasc Magn Reson 2013;15:35.CrossRef Schulz-Menger J, Bluemke DA, Bremerich J, Flamm S, Fogel MA, Friedrich MG, et al. Standardized image interpretation and post processing in cardiovascular magnetic resonance: Society for Cardiovascular Magnetic Resonance (SCMR) Board of Trustees Task Force on Standardized Post Processing. J Cardiovasc Magn Reson 2013;15:35.CrossRef
26.
Zurück zum Zitat Chen Y-C, Ko C-L, Yen R-F, Lo M-F, Huang Y-H, Hsu P-Y, et al. Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography. J Nucl Cardiol 2016;23:348-61.CrossRef Chen Y-C, Ko C-L, Yen R-F, Lo M-F, Huang Y-H, Hsu P-Y, et al. Comparison of biventricular ejection fractions using cadmium-zinc-telluride SPECT and planar equilibrium radionuclide angiography. J Nucl Cardiol 2016;23:348-61.CrossRef
Metadaten
Titel
Assessment of left ventricular ejection fraction with cardiofocal collimators: Comparison between IQ-SPECT, planar equilibrium radionuclide angiography, and cardiac magnetic resonance
verfasst von
Matthieu Pelletier-Galarneau, MD, MSc
Vincent Finnerty, MSc
Stephanie Tan, MD
Sebastien Authier, B Eng
Jean Gregoire, MD
Francois Harel, MD, PhD
Publikationsdatum
08.03.2018
Verlag
Springer International Publishing
Erschienen in
Journal of Nuclear Cardiology
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-018-1251-6

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.