Skip to main content
Erschienen in: The Journal of Indian Prosthodontic Society 2/2013

01.06.2013 | Review Article

Titanium in Dentistry: Historical Development, State of the Art and Future Perspectives

verfasst von: Juliana Ribeiro Pala Jorge, Valentim Adelino Barão, Juliana Aparecida Delben, Leonardo Perez Faverani, Thallita Pereira Queiroz, Wirley Gonçalves Assunção

Erschienen in: The Journal of Indian Prosthodontic Society | Ausgabe 2/2013

Einloggen, um Zugang zu erhalten

Abstract

Titanium is a metallic element known by several attractive characteristics, such as biocompatibility, excellent corrosion resistance and high mechanical resistance. It is widely used in Dentistry, with high success rates, providing a favorable biological response when in contact with live tissues. Therefore, the objective of this study was to describe the different uses of titanium in Dentistry, reviewing its historical development and discoursing about its state of art and future perspective of its utilization. A search in the MEDLINE/PubMed database was performed using the terms ‘titanium’, ‘dentistry’ and ‘implants’. The title and abstract of articles were read, and after this first screening 20 articles were selected and their full-texts were downloaded. Additional text books and manual search of reference lists within selected articles were included. Correlated literature showed that titanium is the most used metal in Implantology for manufacturing osseointegrated implants and their systems, with a totally consolidated utilization. Moreover, titanium can be also employed in prosthodontics to obtain frameworks. However, problems related to its machining, casting, welding and ceramic application for dental prosthesis are still limiting its use. In Endodontics, titanium has been used in association to nickel for manufacturing rotatory instruments, providing a higher resistance to deformation. However, although the different possibilities of using titanium in modern Dentistry, its use for prostheses frameworks still needs technological improvements in order to surpass its limitations.
Literatur
1.
Zurück zum Zitat Van Noort R (2002) Casting alloys for metallic restorations. In: Van Noort R (ed) Introduction to dental materials. Mosby, Toranto, pp 221–230 Van Noort R (2002) Casting alloys for metallic restorations. In: Van Noort R (ed) Introduction to dental materials. Mosby, Toranto, pp 221–230
2.
Zurück zum Zitat Gegel HL, Hoch M (1973) Alloy processing. In: Jaffee RI, Burte HM (eds) Metallurgical society of AIME. Titanium science and technology. Plenum Press, New York, pp 923–931 Gegel HL, Hoch M (1973) Alloy processing. In: Jaffee RI, Burte HM (eds) Metallurgical society of AIME. Titanium science and technology. Plenum Press, New York, pp 923–931
3.
Zurück zum Zitat Brown D (1997) All you wanted to know about titanium, but were afraid to ask. Br Dent J 10:393–394CrossRef Brown D (1997) All you wanted to know about titanium, but were afraid to ask. Br Dent J 10:393–394CrossRef
4.
Zurück zum Zitat Maia A (2003) Titânio. Balanço Mineral Brasileiro 1:1–23 Maia A (2003) Titânio. Balanço Mineral Brasileiro 1:1–23
5.
Zurück zum Zitat Freese HL, Volas MG, Wood RJ (2001) Metallurgy and technological properties of titanium and titanium alloys. In: Brunette DM, Tengvall P, Textor M, Thomsen P (eds) Titanium in medicine: material science, surface science, engineering, biological responses and medical applications. Springer-Verlag, Berlin, pp 13–24 Freese HL, Volas MG, Wood RJ (2001) Metallurgy and technological properties of titanium and titanium alloys. In: Brunette DM, Tengvall P, Textor M, Thomsen P (eds) Titanium in medicine: material science, surface science, engineering, biological responses and medical applications. Springer-Verlag, Berlin, pp 13–24
9.
10.
Zurück zum Zitat Ducheyne P, Healy KE (1988) Surface spectroscopy of calcium phosphate ceramic and titanium implants materials. In: Ratner B (ed) Surface characterization of biomaterials. Elsevier, Amsterdam, pp 175–192 Ducheyne P, Healy KE (1988) Surface spectroscopy of calcium phosphate ceramic and titanium implants materials. In: Ratner B (ed) Surface characterization of biomaterials. Elsevier, Amsterdam, pp 175–192
11.
Zurück zum Zitat Adell R, Eriksson B, Lekholm U, Brånemark P-I, Jemt T (1990) A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 5:347–359PubMed Adell R, Eriksson B, Lekholm U, Brånemark P-I, Jemt T (1990) A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implants 5:347–359PubMed
12.
13.
Zurück zum Zitat Kasemo B (1983) Biocompatibility of titanium implants: surface science aspects. J Prosthet Dent 49:832–837PubMedCrossRef Kasemo B (1983) Biocompatibility of titanium implants: surface science aspects. J Prosthet Dent 49:832–837PubMedCrossRef
14.
Zurück zum Zitat Kaus T, Pröbster L, Weber H (1996) Clinical follow-up study of ceramic veneered titanium restorations—three-year results. Int J Prosthodont 9:9–15PubMed Kaus T, Pröbster L, Weber H (1996) Clinical follow-up study of ceramic veneered titanium restorations—three-year results. Int J Prosthodont 9:9–15PubMed
16.
Zurück zum Zitat Brånemark P-I, Breine U, Adell R, Hansson BO, Lindström J, Ohlsson A (1969) Intraosseous anchorage of dental prostheses. I—experimental studies. Scand J Plast Reconstr Surg 3:81–100PubMedCrossRef Brånemark P-I, Breine U, Adell R, Hansson BO, Lindström J, Ohlsson A (1969) Intraosseous anchorage of dental prostheses. I—experimental studies. Scand J Plast Reconstr Surg 3:81–100PubMedCrossRef
17.
Zurück zum Zitat Brånemark P-I, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, Ohman A (1977) Osseointegrated dental implants in the treatment of edentulous jaw. Experience from a 10 years period. Scand J Plast Reconstr Surg Suppl 16:1–132PubMed Brånemark P-I, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, Ohman A (1977) Osseointegrated dental implants in the treatment of edentulous jaw. Experience from a 10 years period. Scand J Plast Reconstr Surg Suppl 16:1–132PubMed
18.
Zurück zum Zitat Brånemark P-I, Adell R, Albrektsson T, Lekholm U, Lindström J, Rockler B (1984) An experimental and clinical study of osseointegrated implants penetrating the nasal cavity and maxillary sinus. J Oral Maxillofac Surg 42:497–505PubMedCrossRef Brånemark P-I, Adell R, Albrektsson T, Lekholm U, Lindström J, Rockler B (1984) An experimental and clinical study of osseointegrated implants penetrating the nasal cavity and maxillary sinus. J Oral Maxillofac Surg 42:497–505PubMedCrossRef
19.
Zurück zum Zitat ADA Council on Scientific Affairs (2003) Titanium applications in dentistry. J Am Dent Assoc 134:347–349 ADA Council on Scientific Affairs (2003) Titanium applications in dentistry. J Am Dent Assoc 134:347–349
20.
Zurück zum Zitat ASTM Standard, F1295 (2005) Standard specification for wrought titanium-6 aluminum-7 niobium alloy for surgical implant applications, ASTM International, West Conshohocken [ASTM International website]. Available at: http://www.astm.org. Accessed 30 March 2010 ASTM Standard, F1295 (2005) Standard specification for wrought titanium-6 aluminum-7 niobium alloy for surgical implant applications, ASTM International, West Conshohocken [ASTM International website]. Available at: http://​www.​astm.​org. Accessed 30 March 2010
21.
Zurück zum Zitat Wang RR, Fenton A (1996) Titanium for prosthodontic applications: a review of the literature. Quintessence Int 27:401–408PubMed Wang RR, Fenton A (1996) Titanium for prosthodontic applications: a review of the literature. Quintessence Int 27:401–408PubMed
22.
24.
Zurück zum Zitat Tschernitschek H, Borchers L, Geurtsen W (2005) Nonalloyed titanium as a bioinert metal—a review. Quintessence Int 36:523–530PubMed Tschernitschek H, Borchers L, Geurtsen W (2005) Nonalloyed titanium as a bioinert metal—a review. Quintessence Int 36:523–530PubMed
25.
Zurück zum Zitat Bessing C, Bergman M (1992) The castability of unalloyed titanium in three different casting machines. Swed Dent J 16:109–113PubMed Bessing C, Bergman M (1992) The castability of unalloyed titanium in three different casting machines. Swed Dent J 16:109–113PubMed
26.
Zurück zum Zitat Zinellis S (2000) Effect of pressure of helium, argon, krypton and xenon on the porosity, microstructure, and mechanical properties of commercially pure titanium castings. J Prosthet Dent 84:575–584. doi:10.1067/mpr.2000.109479 CrossRef Zinellis S (2000) Effect of pressure of helium, argon, krypton and xenon on the porosity, microstructure, and mechanical properties of commercially pure titanium castings. J Prosthet Dent 84:575–584. doi:10.​1067/​mpr.​2000.​109479 CrossRef
27.
Zurück zum Zitat Lautenschlager EP, Monaghan P (1993) Titanium and titanium alloys as dental materials. Int Dent J 43:245–253PubMed Lautenschlager EP, Monaghan P (1993) Titanium and titanium alloys as dental materials. Int Dent J 43:245–253PubMed
28.
Zurück zum Zitat Örtop A, Jemt T (2001) Développement des aramatures en titane pour la prothése implantaire. Implant 7:169–175 Örtop A, Jemt T (2001) Développement des aramatures en titane pour la prothése implantaire. Implant 7:169–175
29.
Zurück zum Zitat Örtop A, Jemt T (1999) Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaws. A 5-year follow-up study. Clin Implant Dent Relat Res 2:84–91CrossRef Örtop A, Jemt T (1999) Clinical experiences of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaws. A 5-year follow-up study. Clin Implant Dent Relat Res 2:84–91CrossRef
30.
Zurück zum Zitat Kucey BK, Fraser DC (2000) The Procera abutment—the fifth generation abutment for dental implants. J Can Dent Assoc 66:445–449PubMed Kucey BK, Fraser DC (2000) The Procera abutment—the fifth generation abutment for dental implants. J Can Dent Assoc 66:445–449PubMed
31.
Zurück zum Zitat Henriksson K, Jemt T (2003) Evaluation of custom-made Procera ceramic abutments for single implant tooth replacement: a prospective 1-year follow-up study. Int J Prosthodont 16:626–630PubMed Henriksson K, Jemt T (2003) Evaluation of custom-made Procera ceramic abutments for single implant tooth replacement: a prospective 1-year follow-up study. Int J Prosthodont 16:626–630PubMed
32.
Zurück zum Zitat Sjögren G, Andersson M, Bergman M (1988) Laser welding of titanium in dentistry. Acta Odontol Scand 46:247–253PubMedCrossRef Sjögren G, Andersson M, Bergman M (1988) Laser welding of titanium in dentistry. Acta Odontol Scand 46:247–253PubMedCrossRef
Metadaten
Titel
Titanium in Dentistry: Historical Development, State of the Art and Future Perspectives
verfasst von
Juliana Ribeiro Pala Jorge
Valentim Adelino Barão
Juliana Aparecida Delben
Leonardo Perez Faverani
Thallita Pereira Queiroz
Wirley Gonçalves Assunção
Publikationsdatum
01.06.2013
Verlag
Springer-Verlag
Erschienen in
The Journal of Indian Prosthodontic Society / Ausgabe 2/2013
Print ISSN: 0972-4052
Elektronische ISSN: 1998-4057
DOI
https://doi.org/10.1007/s13191-012-0190-1

Weitere Artikel der Ausgabe 2/2013

The Journal of Indian Prosthodontic Society 2/2013 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.